Robby Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Robby Singh has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Marcel Zughaib
Providence Hospital/Michigan State University, Southfield, MI, USA
5 shared publications A. Buth
Detroit Medical Center/Wayne State University, Detroit, MI, USA
1 shared publicationA. Soubani
Detroit Medical Center/Wayne State University, Detroit, MI, USA
1 shared publicationAbbie Bowen
Providence Hospital/Michigan State University, Southfield, MI, USA
1 shared publicationChristian Machado
Department of Cardiology, Providence Hospital, Michigan State University, Detroit, MI, USA
1 shared publication- David E. Freeman
Department of Large Animal Clinical Sciences University of Florida, College of Veterinary Medicine Gainesville Florida USA
1 shared publication
Latest Publications
- Open Access
Impact of Hydroxychloroquine Treatment of COVID-19 on Cardiac Conduction: The Beat Goes On
Objectives: Our study aimed to investigate the frequency of malignant cardiac arrhythmias in hospitalized patients receiving hydroxychloroquine alone and those receiving a combination of hydroxychloroquine with azithromycin, as well as the quantitative extent of QT prolongation within Tisdale Risk Score (TRS) categories. Background: There have been over 33 million cases of SARS-CoV-2 (COVID-19) resulting in over 600,000 deaths in the United States. As the current COVID-19 pandemic continues, numerous medications have been administered to attempt to treat patients afflicted by the disease. While hydroxychloroquine has been in use for decades for rheumatologic and infectious disease processes, it does have potential cardiotoxicity related to drug-induced QT prolongation. Drug-induced QT prolongation has an increased risk of arrhythmogenicity, potentially progressing into torsades de pointes (TdP) and increased patient mortality. The relationship between QT prolongation and TdP is complex and inexact, but there remains optimism regarding the use of these medications in the treatment of COVID-19 despite limited data on their true efficacy. Methods: We retrospectively identified 75 patients who were admitted with COVID-19 and underwent treatment with hydroxychloroquine for 5 days. The hydroxychloroquine protocol was defined as an initial dose of 400 mg BID for the first day, followed by 400 mg daily for the next 4 days. Baseline demographics, medications, medical histories, lab values, ECG QT intervals, and Tisdale Risk Categories were collected for all patients. Results: Seventy-four (98.7%) patients completed the full course of hydroxychloroquine. There were 41 males (54.7%) and 34 females (45.3%). Average length of stay was 8.9 days (95% CI: 7.5, 10.2). One patient who could not complete the course due to inability to swallow medication tablets. There were no reports of new arrythmias or incidence of torsades de pointes during the study. Seventy-two patients (96%) were taking at least 2 QT prolonging medications. The average corrected QT intervals were as follows: day 1 of admission was 421.62 milliseconds (n = 66, 95% CI: 412.19, 431.05), day 2 was 431.50 ms (n = 30, 95% CI: 416.34, 446.66), day 3 was 433.48 ms (n = 23, 95% CI: 413.34, 453.61), day 4 was 427.59 ms (n = 17, 95% CI: 400.83, 454.35), and day 5 was 444.28 ms (n = 18, 95% CI: 428.43, 460.12). The corrected QT interval prolonged by 22.66 ms from day 1 to day 5 (p = 0.03) in the overall population. Conclusion: There were no patients who experienced arrhythmogenicity or Torsades de Pointes despite a statistically significant increase in QTc intervals after patients received the 5-day course of hydroxychloroquine for treatment of COVID-19.
Open AccessImpact of Hydroxychloroquine Treatment of COVID-19 on Cardiac Conduction: The Beat Goes On
Objectives: Our study aimed to investigate the frequency of malignant cardiac arrhythmias in hospitalized patients receiving hydroxychloroquine alone and those receiving a combination of hydroxychloroquine with azithromycin, as well as the quantitative extent of QT prolongation within Tisdale Risk Score (TRS) categories. Background: There have been over 33 million cases of SARS-CoV-2 (COVID-19) resulting in over 600,000 deaths in the United States. As the current COVID-19 pandemic continues, numerous medications have been administered to attempt to treat patients afflicted by the disease. While hydroxychloroquine has been in use for decades for rheumatologic and infectious disease processes, it does have potential cardiotoxicity related to drug-induced QT prolongation. Drug-induced QT prolongation has an increased risk of arrhythmogenicity, potentially progressing into torsades de pointes (TdP) and increased patient mortality. The relationship between QT prolongation and TdP is complex and inexact, but there remains optimism regarding the use of these medications in the treatment of COVID-19 despite limited data on their true efficacy. Methods: We retrospectively identified 75 patients who were admitted with COVID-19 and underwent treatment with hydroxychloroquine for 5 days. The hydroxychloroquine protocol was defined as an initial dose of 400 mg BID for the first day, followed by 400 mg daily for the next 4 days. Baseline demographics, medications, medical histories, lab values, ECG QT intervals, and Tisdale Risk Categories were collected for all patients. Results: Seventy-four (98.7%) patients completed the full course of hydroxychloroquine. There were 41 males (54.7%) and 34 females (45.3%). Average length of stay was 8.9 days (95% CI: 7.5, 10.2). One patient who could not complete the course due to inability to swallow medication tablets. There were no reports of new arrythmias or incidence of torsades de pointes during the study. Seventy-two patients (96%) were taking at least 2 QT prolonging medications. The average corrected QT intervals were as follows: day 1 of admission was 421.62 milliseconds (n = 66, 95% CI: 412.19, 431.05), day 2 was 431.50 ms (n = 30, 95% CI: 416.34, 446.66), day 3 was 433.48 ms (n = 23, 95% CI: 413.34, 453.61), day 4 was 427.59 ms (n = 17, 95% CI: 400.83, 454.35), and day 5 was 444.28 ms (n = 18, 95% CI: 428.43, 460.12). The corrected QT interval prolonged by 22.66 ms from day 1 to day 5 (p = 0.03) in the overall population. Conclusion: There were no patients who experienced arrhythmogenicity or Torsades de Pointes despite a statistically significant increase in QTc intervals after patients received the 5-day course of hydroxychloroquine for treatment of COVID-19.
- Open Access
- 11 February 2020
- Published by Wiley in Case Reports in Cardiology
- Vol. 2020, 1-4
Wedged Sensor in Distress? Lessons Learned from Troubleshooting Dampened Transmitted PA Waveforms of CardioMEMS Device
Introduction. Cardiovascular disease is a leading cause of morbidity and mortality with heart failure constituting a large portion of this spectrum. Heart failure patients have 90-day readmission rates of nearly 41% associated with a high expense. Numerous strategies to reduce readmissions have been attempted with the CardioMEMS pulmonary artery pressure monitoring system as one of the more successful ones. As this device becomes used more frequently, it is important to recognize procedural complications. We present of a rare complication where a patient underwent successful device placement and was subsequently found to have dampened waveforms which were due to device migration. Case Report. A 79-year-old male underwent successful CardioMEMS placement due to recurrent heart failure hospitalizations. 6 months later, the transmitted waveforms appeared dampened, and repeat angiography revealed a device that had migrated. Rather than abandoning the device, it was recalibrated and continued to transmit data and helped manage the patient’s heart failure. Conclusion. CardioMEMS is a cost-effective tool to help reduce heart failure hospitalizations. Device migration is a rare complication and can lead to inaccurate data. However, as seen in this case, the device can be successfully recalibrated and can continue to be utilized to help reduce heart failure admissions.
- 11 February 2020
- Published by Wiley in Case Reports in Cardiology
- Vol. 2020, 1-4
Open AccessWedged Sensor in Distress? Lessons Learned from Troubleshooting Dampened Transmitted PA Waveforms of CardioMEMS Device
Introduction. Cardiovascular disease is a leading cause of morbidity and mortality with heart failure constituting a large portion of this spectrum. Heart failure patients have 90-day readmission rates of nearly 41% associated with a high expense. Numerous strategies to reduce readmissions have been attempted with the CardioMEMS pulmonary artery pressure monitoring system as one of the more successful ones. As this device becomes used more frequently, it is important to recognize procedural complications. We present of a rare complication where a patient underwent successful device placement and was subsequently found to have dampened waveforms which were due to device migration. Case Report. A 79-year-old male underwent successful CardioMEMS placement due to recurrent heart failure hospitalizations. 6 months later, the transmitted waveforms appeared dampened, and repeat angiography revealed a device that had migrated. Rather than abandoning the device, it was recalibrated and continued to transmit data and helped manage the patient’s heart failure. Conclusion. CardioMEMS is a cost-effective tool to help reduce heart failure hospitalizations. Device migration is a rare complication and can lead to inaccurate data. However, as seen in this case, the device can be successfully recalibrated and can continue to be utilized to help reduce heart failure admissions.
- Open Access
- 23 October 2019
- Published by Hindawi Limited in Cardiology Research and Practice
- Vol. 2019, 1-4
Appropriate Use of Transesophageal Echocardiogram for Infective Endocarditis: A Single Center Experience
Background. Transesophageal echocardiogram (TEE) is a valuable tool in healthcare today with its ease of use, ability to visualize important structures not seen on transthoracic echocardiogram (TTE), and the relatively lower cost of TEE, high yield, and no significant radiation exposure. The American Society of Echocardiography (ASE) has developed an appropriate use criteria for use of TTE and TEE, which outline various scenarios where a TEE is indicated as an initial diagnostic testing modality and when it is useful as an adjunctive test in hopes of decreasing inappropriate use. Using these criteria as a guide, we devised a quality assessment study to investigate how well TEEs performed at our institution fit the appropriate use criteria specifically for the diagnostic workup of infective endocarditis. Methods. A retrospective chart review was performed for all TEEs performed in 2017 with the indication of endocarditis. Baseline patient characteristics, presence of bacteremia, and the quality of the TTE preceding the TEE were noted, as well as whether a vegetation, abscess, or perforation was visualized. We also determined if there was a cardiology consultation placed prior to TEE and if the patient had met the definition for endocarditis as defined by the Duke criteria. Finally, we made note of the TEE findings and assessed whether the TEE met appropriate use criteria developed by the American Society of Echocardiography. Results. A total of 50 patients who underwent TEE with the indication of “endocarditis” were identified. 36% of the TTEs prior to the TEE were rated as good quality, 40% as adequate, 4% as fair, 4% as suboptimal, 12% as technically difficult, and 4% were not rated. Vegetations were visualized on 12% of TTEs, 6% of patients had a prosthetic valve, and 6% had a cardiac device. In 20% of the cases, there was no cardiology consultation prior to the TEE and in 20% of the cases, there was no documented bacteremia. 26% of patients met the Duke criteria for endocarditis prior to TEE. Only 36% of TEEs revealed evidence of infection and of the patients with no evidence of infection, only 38% met appropriate use criteria. Overall, only 56% of patients met appropriate use criteria for TEE. Conclusion. Transesophageal echocardiography is a valuable tool in a modern physician’s arsenal for managing a variety of diseases and conditions. However, the procedure is not without associated risks and its ease of use and widespread adoption has led to frequent questionable appropriateness of use of the test. Only 56% of the TEEs performed in our analysis met appropriate use. More awareness and education is needed for the appropriate use criteria for transesophageal echocardiography as outlined by the ASE to help reduce patient exposure to procedure related complications and to decrease medical costs on unnecessary procedures.
- 23 October 2019
- Published by Hindawi Limited in Cardiology Research and Practice
- Vol. 2019, 1-4
Open AccessAppropriate Use of Transesophageal Echocardiogram for Infective Endocarditis: A Single Center Experience
Background. Transesophageal echocardiogram (TEE) is a valuable tool in healthcare today with its ease of use, ability to visualize important structures not seen on transthoracic echocardiogram (TTE), and the relatively lower cost of TEE, high yield, and no significant radiation exposure. The American Society of Echocardiography (ASE) has developed an appropriate use criteria for use of TTE and TEE, which outline various scenarios where a TEE is indicated as an initial diagnostic testing modality and when it is useful as an adjunctive test in hopes of decreasing inappropriate use. Using these criteria as a guide, we devised a quality assessment study to investigate how well TEEs performed at our institution fit the appropriate use criteria specifically for the diagnostic workup of infective endocarditis. Methods. A retrospective chart review was performed for all TEEs performed in 2017 with the indication of endocarditis. Baseline patient characteristics, presence of bacteremia, and the quality of the TTE preceding the TEE were noted, as well as whether a vegetation, abscess, or perforation was visualized. We also determined if there was a cardiology consultation placed prior to TEE and if the patient had met the definition for endocarditis as defined by the Duke criteria. Finally, we made note of the TEE findings and assessed whether the TEE met appropriate use criteria developed by the American Society of Echocardiography. Results. A total of 50 patients who underwent TEE with the indication of “endocarditis” were identified. 36% of the TTEs prior to the TEE were rated as good quality, 40% as adequate, 4% as fair, 4% as suboptimal, 12% as technically difficult, and 4% were not rated. Vegetations were visualized on 12% of TTEs, 6% of patients had a prosthetic valve, and 6% had a cardiac device. In 20% of the cases, there was no cardiology consultation prior to the TEE and in 20% of the cases, there was no documented bacteremia. 26% of patients met the Duke criteria for endocarditis prior to TEE. Only 36% of TEEs revealed evidence of infection and of the patients with no evidence of infection, only 38% met appropriate use criteria. Overall, only 56% of patients met appropriate use criteria for TEE. Conclusion. Transesophageal echocardiography is a valuable tool in a modern physician’s arsenal for managing a variety of diseases and conditions. However, the procedure is not without associated risks and its ease of use and widespread adoption has led to frequent questionable appropriateness of use of the test. Only 56% of the TEEs performed in our analysis met appropriate use. More awareness and education is needed for the appropriate use criteria for transesophageal echocardiography as outlined by the ASE to help reduce patient exposure to procedure related complications and to decrease medical costs on unnecessary procedures.
- 20 April 2019
- Published by International Scientific Information, Inc. in American Journal of Case Reports
- Vol. 20, 557-561
Atrial-Esophageal Fistula After Catheter Ablation: Diagnosing and Managing a Rare Complication of a Common Procedure
BACKGROUND:Atrial fibrillation is considered the most common cardiac arrhythmias in the United States with rate and rhythm control strategies traditionally used for management. If patients are intolerant to class I or class III anti-arrhythmic medica...
- 20 April 2019
- Published by International Scientific Information, Inc. in American Journal of Case Reports
- Vol. 20, 557-561
Atrial-Esophageal Fistula After Catheter Ablation: Diagnosing and Managing a Rare Complication of a Common Procedure
BACKGROUND:Atrial fibrillation is considered the most common cardiac arrhythmias in the United States with rate and rhythm control strategies traditionally used for management. If patients are intolerant to class I or class III anti-arrhythmic medica...
- Open Access
- 15 January 2019
- Published by Wiley in Cardiology Research and Practice
- Vol. 2019, 1-6
Timeout for Contrast: Using Physician Behavior Modification to Reduce Contrast in the Catheterization Laboratory
Background. As the number of procedures using contrast media continues to rise, the ensuing complications place an ever increasing burden on the healthcare system. Contrast-induced nephropathy (CIN) is a common postprocedural complication after cardiac catheterization. Objectives. The purpose of our study was to evaluate the impact of physician behavioral modification on reducing the amount of contrast used during the procedure. Methods. All patients who underwent procedures in the cardiac catheterization laboratory from January 2013 to August 2016 were identified in addition to the total contrast used during the procedure, the type of procedure performed, and the operator performing the procedure. A new addition was made to the preprocedure checklist in September-October 2013 in the form of maximum allowed contrast for the patient. Results. A total of 12,118 cases were identified. Across all procedures, the mean contrast used during the 8 months prior to the intervention was 118 ml per procedure. Mean contrast used per procedure for the first year after the revised timeout was 105 ml, for the second year was 106 ml, and for the third year was 99 ml. Conclusion. A significant reduction in radiocontrast use across all operators and procedures after the introduction of a revised timeout procedure that was seen, which is a change that was sustained over a period of three years. With this straightforward intervention involving physician behavioral modification, patients were exposed to less of the nephrotoxic contrast and were consequently at a lower risk of developing dose-depended CIN and other associated complications.
- 15 January 2019
- Published by Wiley in Cardiology Research and Practice
- Vol. 2019, 1-6
Open AccessTimeout for Contrast: Using Physician Behavior Modification to Reduce Contrast in the Catheterization Laboratory
Background. As the number of procedures using contrast media continues to rise, the ensuing complications place an ever increasing burden on the healthcare system. Contrast-induced nephropathy (CIN) is a common postprocedural complication after cardiac catheterization. Objectives. The purpose of our study was to evaluate the impact of physician behavioral modification on reducing the amount of contrast used during the procedure. Methods. All patients who underwent procedures in the cardiac catheterization laboratory from January 2013 to August 2016 were identified in addition to the total contrast used during the procedure, the type of procedure performed, and the operator performing the procedure. A new addition was made to the preprocedure checklist in September-October 2013 in the form of maximum allowed contrast for the patient. Results. A total of 12,118 cases were identified. Across all procedures, the mean contrast used during the 8 months prior to the intervention was 118 ml per procedure. Mean contrast used per procedure for the first year after the revised timeout was 105 ml, for the second year was 106 ml, and for the third year was 99 ml. Conclusion. A significant reduction in radiocontrast use across all operators and procedures after the introduction of a revised timeout procedure that was seen, which is a change that was sustained over a period of three years. With this straightforward intervention involving physician behavioral modification, patients were exposed to less of the nephrotoxic contrast and were consequently at a lower risk of developing dose-depended CIN and other associated complications.
- Open Access
- 7 November 2018
- Published by Wiley in Cardiology Research and Practice
- Vol. 2018, 1-5
CardioMEMS in a Busy Cardiology Practice: Less than Optimal Implementation of a Valuable Tool to Reduce Heart Failure Readmissions
Introduction. Congestive heart failure is a leading cause of cardiovascular morbidity and mortality that results in a significant financial burden on healthcare expenditure. Though various strategies have been employed to reduce hospital readmissions, one valuable tool that remains greatly underutilized is the CardioMEMS (Abbott), a remote pulmonary artery pressure-monitoring system, which has been shown to help reduce heart failure rehospitalizations in the CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) trial. Methods. ICD-9/ICD-10 codes for chronic heart failure were used to identify patients who presented with congestive heart failure. Of this group, those eligible for CardioMEMS device placement, as based on the CHAMPION trial definition, were selected. Subsequently, a retrospective review of the electronic medical records was completed. All patients were on ACC/AHA guideline-directed medical therapy and had at least one hospital admission for NYHA class III symptoms. Results. 473 patients met the inclusion criteria, of which, 85 patients were found to be eligible for implantation of CardioMEMS device based on the CHAMPION trial definition. Only 18/85 patients received the device, roughly 21%, and the overall CardioMEMS implantation rate was only 4% (18/473) of the total cohort. Conclusion. Despite the benefits to patients and reducing healthcare expenditure, there has been a poor adaptation of this groundbreaking technology. Our study revealed that 79% of eligible heart failure patients did not receive the device. Therefore, efforts need to be undertaken to improve physician and patient education of the device to complement the current standard of care for congestive heart failure.
- 7 November 2018
- Published by Wiley in Cardiology Research and Practice
- Vol. 2018, 1-5
Open AccessCardioMEMS in a Busy Cardiology Practice: Less than Optimal Implementation of a Valuable Tool to Reduce Heart Failure Readmissions
Introduction. Congestive heart failure is a leading cause of cardiovascular morbidity and mortality that results in a significant financial burden on healthcare expenditure. Though various strategies have been employed to reduce hospital readmissions, one valuable tool that remains greatly underutilized is the CardioMEMS (Abbott), a remote pulmonary artery pressure-monitoring system, which has been shown to help reduce heart failure rehospitalizations in the CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) trial. Methods. ICD-9/ICD-10 codes for chronic heart failure were used to identify patients who presented with congestive heart failure. Of this group, those eligible for CardioMEMS device placement, as based on the CHAMPION trial definition, were selected. Subsequently, a retrospective review of the electronic medical records was completed. All patients were on ACC/AHA guideline-directed medical therapy and had at least one hospital admission for NYHA class III symptoms. Results. 473 patients met the inclusion criteria, of which, 85 patients were found to be eligible for implantation of CardioMEMS device based on the CHAMPION trial definition. Only 18/85 patients received the device, roughly 21%, and the overall CardioMEMS implantation rate was only 4% (18/473) of the total cohort. Conclusion. Despite the benefits to patients and reducing healthcare expenditure, there has been a poor adaptation of this groundbreaking technology. Our study revealed that 79% of eligible heart failure patients did not receive the device. Therefore, efforts need to be undertaken to improve physician and patient education of the device to complement the current standard of care for congestive heart failure.
- Open Access
- 1 October 2018
- Published by Wiley in Case Reports in Cardiology
- Vol. 2018, 1-4
Inverted Yoga and Near Syncope: An Unusual Diagnosis of Right Ventricular Myxoma
Primary cardiac tumors are extremely rare and are difficult to diagnose. Although usually benign in nature, myxomas require surgical resection due to their increased risk of embolic and cardiac complications, with the timing of resection dependent on the presentation and size of the tumor. However, if diagnosed early, patients with primary benign cardiac tumors have excellent prognosis following surgery. Therefore, a high index of suspicion and a wide differential diagnosis are very important in detecting rare conditions that can affect otherwise healthy individuals. We present an uncommon case of a right ventricular myxoma that was discovered when the patient was performing inverted yoga and experienced a near syncopal episode. Patient subsequently underwent an echocardiographic evaluation and was found to have a right ventricular myxoma that was excised. Although recurrence is rare, it is important for physicians to remain vigilant and continue careful and consistent follow-up for patients with a history of a cardiac myxoma.
- 1 October 2018
- Published by Wiley in Case Reports in Cardiology
- Vol. 2018, 1-4
Open AccessInverted Yoga and Near Syncope: An Unusual Diagnosis of Right Ventricular Myxoma
Primary cardiac tumors are extremely rare and are difficult to diagnose. Although usually benign in nature, myxomas require surgical resection due to their increased risk of embolic and cardiac complications, with the timing of resection dependent on the presentation and size of the tumor. However, if diagnosed early, patients with primary benign cardiac tumors have excellent prognosis following surgery. Therefore, a high index of suspicion and a wide differential diagnosis are very important in detecting rare conditions that can affect otherwise healthy individuals. We present an uncommon case of a right ventricular myxoma that was discovered when the patient was performing inverted yoga and experienced a near syncopal episode. Patient subsequently underwent an echocardiographic evaluation and was found to have a right ventricular myxoma that was excised. Although recurrence is rare, it is important for physicians to remain vigilant and continue careful and consistent follow-up for patients with a history of a cardiac myxoma.
- Open Access
- 28 May 2018
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 46 (8) , 3195-3199
Impact of CardioMEMS device placement on lifestyle modifications: a “pseudo-placebo” effect beyond the expected?
Introduction: Congestive heart failure is a leading cause of cardiovascular mortality and morbidity in the United States and places a significant economic burden on the health care system. The CHAMPION trial showed significant reductions in heart failure hospitalizations and length of stay as well as improvements in quality of life among patients who underwent implantation of the CardioMEMS device (CardioMEMS Inc., Atlanta, GA, USA). While the benefits of the device have been well demonstrated, we explored the “pseudo-placebo” effect of device placement on patients’ lifestyle modifications. Methods: Thirty patients with the CardioMEMS device were contacted for a follow-up survey that included questions about lifestyle modifications, symptomatic and dietary improvement, increased physical activity, and changes in their cardiac medication regimen. Results: Dyspnea improved in 57% of patients, 70% of patients improved their diet, and 43% increased their physical activity. Only 7% of patients found it difficult to transmit the data. Discussion: The CHAMPION trial showed numerous benefits for patients who underwent CardioMEMS device placement. In our study, we found that device placement also resulted in a “pseudo-placebo” effect with most patients making positive lifestyle modifications.
- 28 May 2018
- Published by SAGE Publications in Journal of International Medical Research
- Vol. 46 (8) , 3195-3199
Open AccessImpact of CardioMEMS device placement on lifestyle modifications: a “pseudo-placebo” effect beyond the expected?
Introduction: Congestive heart failure is a leading cause of cardiovascular mortality and morbidity in the United States and places a significant economic burden on the health care system. The CHAMPION trial showed significant reductions in heart failure hospitalizations and length of stay as well as improvements in quality of life among patients who underwent implantation of the CardioMEMS device (CardioMEMS Inc., Atlanta, GA, USA). While the benefits of the device have been well demonstrated, we explored the “pseudo-placebo” effect of device placement on patients’ lifestyle modifications. Methods: Thirty patients with the CardioMEMS device were contacted for a follow-up survey that included questions about lifestyle modifications, symptomatic and dietary improvement, increased physical activity, and changes in their cardiac medication regimen. Results: Dyspnea improved in 57% of patients, 70% of patients improved their diet, and 43% increased their physical activity. Only 7% of patients found it difficult to transmit the data. Discussion: The CHAMPION trial showed numerous benefits for patients who underwent CardioMEMS device placement. In our study, we found that device placement also resulted in a “pseudo-placebo” effect with most patients making positive lifestyle modifications.
- Open Access
- 25 October 2016
- Published by Wiley in Case Reports in Critical Care
- Vol. 2016, 1-6
Ethylene Glycol Poisoning: An Unusual Cause of Altered Mental Status and the Lessons Learned from Management of the Disease in the Acute Setting
Ethylene glycol is found in many household products and is a common toxic ingestion. Acute ingestions present with altered sensorium and an osmolal gap. The true toxicity of ethylene glycol is mediated by its metabolites, which are responsible for the increased anion gap metabolic acidosis, renal tubular damage, and crystalluria seen later in ingestions. Early intervention is key; however, diagnosis is often delayed, especially in elderly patients presenting with altered mental status. There are several laboratory tests which can be exploited for the diagnosis, quantification of ingestion, and monitoring of treatment, including the lactate and osmolal gaps. As methods of direct measurement of ethylene glycol are often not readily available, it is important to have a high degree of suspicion based on these indirect laboratory findings. Mainstay of treatment is bicarbonate, fomepizole or ethanol, and, often, hemodialysis. A validated equation can be used to estimate necessary duration of hemodialysis, and even if direct measurements of ethylene glycol are not available, monitoring for the closure of the anion, lactate, and osmolal gaps can guide treatment. We present the case of an elderly male with altered mental status, acute kidney injury, elevated anion gap metabolic acidosis, and profound lactate and osmolal gaps.
- 25 October 2016
- Published by Wiley in Case Reports in Critical Care
- Vol. 2016, 1-6
Open AccessEthylene Glycol Poisoning: An Unusual Cause of Altered Mental Status and the Lessons Learned from Management of the Disease in the Acute Setting
Ethylene glycol is found in many household products and is a common toxic ingestion. Acute ingestions present with altered sensorium and an osmolal gap. The true toxicity of ethylene glycol is mediated by its metabolites, which are responsible for the increased anion gap metabolic acidosis, renal tubular damage, and crystalluria seen later in ingestions. Early intervention is key; however, diagnosis is often delayed, especially in elderly patients presenting with altered mental status. There are several laboratory tests which can be exploited for the diagnosis, quantification of ingestion, and monitoring of treatment, including the lactate and osmolal gaps. As methods of direct measurement of ethylene glycol are often not readily available, it is important to have a high degree of suspicion based on these indirect laboratory findings. Mainstay of treatment is bicarbonate, fomepizole or ethanol, and, often, hemodialysis. A validated equation can be used to estimate necessary duration of hemodialysis, and even if direct measurements of ethylene glycol are not available, monitoring for the closure of the anion, lactate, and osmolal gaps can guide treatment. We present the case of an elderly male with altered mental status, acute kidney injury, elevated anion gap metabolic acidosis, and profound lactate and osmolal gaps.