Yasser S. Soliman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yasser S. Soliman has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Atef A. Abdel Fattah
Atomic Energy Authority
11 shared publications - Wafaa B. Beshir
National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority, Cairo 11787, Egypt
6 shared publications A.A. Abdel-Fattah
Radiation Protection and Dosimetry Department, National Center for Radiation Research and Technology, Atomic Energy Authority (AEA), P.O. Box 8029, Nasr City, Cairo, Egypt
4 shared publications- Mahmoud H. Abdelgawad
Physics Department, Faculty of Science, Al-Azhar University, Cairo, Egypt
4 shared publications - A.M.M. Bayomi
National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), PO Box 8029, Nasr City, Cairo, Egypt
3 shared publications - Ahmed Ali Basfar
Mechanical Engineering Department, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia
3 shared publications
Latest Publications
- Open Access
Study of Ag Nanoparticles in a Polyacrylamide Hydrogel Dosimeters by Optical Technique
The dosimetric characteristics of hydrogel dosimeters based on polyacrylamide (PAC) as a capping agent incorporating silver nitrate as a radiation-sensitive material are investigated using UV-Vis spectrophotometry within the dose range 0–100 Gy. Glycerol was used in the hydrogel matrix to promote the dosimetric response and increase the radiation sensitivity. Upon exposing the PAC hydrogel to γ-ray, it exhibits a Surface Plasmon Resonance (SPR) band at 453 nm, and its intensity increases linearly with absorbed doses up to 100 Gy. The results are compared with the silver nitrate gel dosimeter. Glycerol of 15% in the hydrogel matrix enhances the radiation sensitivity by about 30%. PAC hydrogel dosimeter can be considered a near water equivalent material in the 400 keV–20 MeV photon energy range. At doses less than 15 Gy, the PAC hydrogel dosimeter retains higher radiation sensitivity than the gel dosimeter. The total uncertainty (2σ) of the dose estimated using this hydrogel is about 4%. These results may support the validity of using this hydrogel as a dosimeter to verify radiotherapy techniques and dose monitoring during blood irradiation.
Open AccessStudy of Ag Nanoparticles in a Polyacrylamide Hydrogel Dosimeters by Optical Technique
The dosimetric characteristics of hydrogel dosimeters based on polyacrylamide (PAC) as a capping agent incorporating silver nitrate as a radiation-sensitive material are investigated using UV-Vis spectrophotometry within the dose range 0–100 Gy. Glycerol was used in the hydrogel matrix to promote the dosimetric response and increase the radiation sensitivity. Upon exposing the PAC hydrogel to γ-ray, it exhibits a Surface Plasmon Resonance (SPR) band at 453 nm, and its intensity increases linearly with absorbed doses up to 100 Gy. The results are compared with the silver nitrate gel dosimeter. Glycerol of 15% in the hydrogel matrix enhances the radiation sensitivity by about 30%. PAC hydrogel dosimeter can be considered a near water equivalent material in the 400 keV–20 MeV photon energy range. At doses less than 15 Gy, the PAC hydrogel dosimeter retains higher radiation sensitivity than the gel dosimeter. The total uncertainty (2σ) of the dose estimated using this hydrogel is about 4%. These results may support the validity of using this hydrogel as a dosimeter to verify radiotherapy techniques and dose monitoring during blood irradiation.
- 2 June 2021
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 329 (1) , 463-473
Dosimetric investigations on radiation-induced Ag nanoparticles in a gel dosimeter
- 2 June 2021
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 329 (1) , 463-473
Dosimetric investigations on radiation-induced Ag nanoparticles in a gel dosimeter
- 1 March 2020
- Published by Elsevier in Physica Medica
- Vol. 71, 161-167
A comparative dosimetry study of an alanine dosimeter with a PTW PinPoint chamber at ultra-high dose rates of synchrotron radiation
- 1 March 2020
- Published by Elsevier in Physica Medica
- Vol. 71, 161-167
A comparative dosimetry study of an alanine dosimeter with a PTW PinPoint chamber at ultra-high dose rates of synchrotron radiation
- 8 July 2019
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 58 (4) , 501-511
A new EPR dosimeter based on glutamic acid for radiation processing application
L-Glutamic acid (L-GA) pellets (3.8 mm × 4 mm) and powder dosimeters were studied in the dose range of 0.1–150 kGy using the electron paramagnetic resonance (EPR) technique. The EPR spectra of irradiated L-GA pellets showed an EPR signal with eight lines, and the intensity of the signal increased with an increase of absorbed dose. The results obtained in terms of the energy-absorption coefficients suggest a similar performance of the L-GA pellets as compared to alanine pellets. The value of the temperature coefficient for the L-GA pellets during irradiation was around − 0.08%/°C which is lower than that reported for alanine dosimeter, 0.14%/°C. The influence of humidity on the pellet response was found to be negligible; i.e., the increase in response was only about 2% for a relative humidity of up to 94%. The response of L-GA powder reached stability 4 h after irradiation and continued to be stable until 47 days after irradiation. In contrast, the response of the L-GA pellet dosimeter reached stability 22 h after irradiation and continued to be stable until 8 days after irradiation. For routine applications, the L-GA pellet dosimeter should be analyzed during the stable period after irradiation, to minimize the uncertainties in dose assessment. The overall two-sigma uncertainties in absorbed dose estimation were 5.1% and 3.9% for the dose ranges of 0.1–15 kGy and 15–150 kGy, respectively. It is concluded that L-GA pellets represent a promising dosimeter material for quantification of radiation doses in food irradiation, medical sterilization and polymer modification.
- 8 July 2019
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 58 (4) , 501-511
A new EPR dosimeter based on glutamic acid for radiation processing application
L-Glutamic acid (L-GA) pellets (3.8 mm × 4 mm) and powder dosimeters were studied in the dose range of 0.1–150 kGy using the electron paramagnetic resonance (EPR) technique. The EPR spectra of irradiated L-GA pellets showed an EPR signal with eight lines, and the intensity of the signal increased with an increase of absorbed dose. The results obtained in terms of the energy-absorption coefficients suggest a similar performance of the L-GA pellets as compared to alanine pellets. The value of the temperature coefficient for the L-GA pellets during irradiation was around − 0.08%/°C which is lower than that reported for alanine dosimeter, 0.14%/°C. The influence of humidity on the pellet response was found to be negligible; i.e., the increase in response was only about 2% for a relative humidity of up to 94%. The response of L-GA powder reached stability 4 h after irradiation and continued to be stable until 47 days after irradiation. In contrast, the response of the L-GA pellet dosimeter reached stability 22 h after irradiation and continued to be stable until 8 days after irradiation. For routine applications, the L-GA pellet dosimeter should be analyzed during the stable period after irradiation, to minimize the uncertainties in dose assessment. The overall two-sigma uncertainties in absorbed dose estimation were 5.1% and 3.9% for the dose ranges of 0.1–15 kGy and 15–150 kGy, respectively. It is concluded that L-GA pellets represent a promising dosimeter material for quantification of radiation doses in food irradiation, medical sterilization and polymer modification.
- 1 June 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 148, 240-245
Evaluations of N-(Isobutoxymethyl) acrylamide gel dosimeter by NMR technique for radiotherapy and uncertainty in dose measurements
- 1 June 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 148, 240-245
Evaluations of N-(Isobutoxymethyl) acrylamide gel dosimeter by NMR technique for radiotherapy and uncertainty in dose measurements
- 1 January 2019
- Published by Elsevier in Physica Medica
- Vol. 57, 169-176
Pergascript orange-based polymeric solution as a dosimeter for radiotherapy dosimetric validation
- 1 January 2019
- Published by Elsevier in Physica Medica
- Vol. 57, 169-176
Pergascript orange-based polymeric solution as a dosimeter for radiotherapy dosimetric validation
- 21 August 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 141, 80-87
Radiochromic film containing poly(hexa-2,4-diynylene adipate) as a radiation dosimeter
- 21 August 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 141, 80-87
Radiochromic film containing poly(hexa-2,4-diynylene adipate) as a radiation dosimeter
- 28 March 2018
- Published by Springer Nature in Journal of Polymer Research
- Vol. 25 (4) , 106
Synthesis and characterization of conjugated and nanostructured poly(propargyl alcohol) polymers
- 28 March 2018
- Published by Springer Nature in Journal of Polymer Research
- Vol. 25 (4) , 106
Synthesis and characterization of conjugated and nanostructured poly(propargyl alcohol) polymers
- 1 March 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 144, 56-62
A radiation-sensitive monomer of 2,4-hexadiyn-1,6-bis(p-toluene sulphonyl urethane) in PVA as a radiochromic film dosimeter
- 1 March 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 144, 56-62
A radiation-sensitive monomer of 2,4-hexadiyn-1,6-bis(p-toluene sulphonyl urethane) in PVA as a radiochromic film dosimeter
- 1 December 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 141, 66-72
Performance improvement of pentacosa-diynoic acid label dosimeter for radiation processing technology
- 1 December 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 141, 66-72
Performance improvement of pentacosa-diynoic acid label dosimeter for radiation processing technology