Neveen A. Hosny
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neveen A. Hosny has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Marina Konstantinovna Kuimova
Imperial College London
5 shared publications - David A. Lee
School of Engineering and Materials Science, Queen Mary University of London, London, UK
2 shared publications - Eleanor Stride
Institute of Biomedical Engineering, University of Oxford, Oxford, UK
2 shared publications - Francis David Pope
School of Geography, Earth, and Environmental Sciences, University of Birmingham, Edgbaston, Birmingham, United Kingdom
2 shared publications Graciela Mohamedi
Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX3 7DQ, United Kingdom
2 shared publications- Gunnar Spickermann
M Squared Life Limited, 14 East Bay Lane, The Press Centre, Here East, Queen Elizabeth Park, Stratford , E15 2GW
2 shared publications
Latest Publications
- Open Access
- 18 October 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (5) , 925-943
Intravital Microscopy With an Airy Beam Light Sheet Microscope Improves Temporal Resolution and Reduces Surgical Trauma
Intravital microscopy has emerged as a powerful imaging tool, which allows the visualization and precise understanding of rapid physiological processes at sites of inflammation in vivo, such as vascular permeability and leukocyte migration. Leukocyte interactions with the vascular endothelium can be characterized in the living organism in the murine cremaster muscle. Here, we present a microscopy technique using an Airy Beam Light Sheet microscope that has significant advantages over our previously used confocal microscopy systems. In comparison, the light sheet microscope offers near isotropic optical resolution and faster acquisition speed, while imaging a larger field of view. With less invasive surgery we can significantly reduce side effects such as bleeding, muscle twitching, and surgical inflammation. However, the increased acquisition speed requires exceptional tissue stability to avoid imaging artefacts. Since respiratory motion is transmitted to the tissue under investigation, we have developed a relocation algorithm that removes motion artefacts from our intravital microscopy images. Using these techniques, we are now able to obtain more detailed 3D time-lapse images of the cremaster vascular microcirculation, which allow us to observe the process of leukocyte emigration into the surrounding tissue with increased temporal resolution in comparison to our previous confocal approach.
- 18 October 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (5) , 925-943
Open AccessIntravital Microscopy With an Airy Beam Light Sheet Microscope Improves Temporal Resolution and Reduces Surgical Trauma
Intravital microscopy has emerged as a powerful imaging tool, which allows the visualization and precise understanding of rapid physiological processes at sites of inflammation in vivo, such as vascular permeability and leukocyte migration. Leukocyte interactions with the vascular endothelium can be characterized in the living organism in the murine cremaster muscle. Here, we present a microscopy technique using an Airy Beam Light Sheet microscope that has significant advantages over our previously used confocal microscopy systems. In comparison, the light sheet microscope offers near isotropic optical resolution and faster acquisition speed, while imaging a larger field of view. With less invasive surgery we can significantly reduce side effects such as bleeding, muscle twitching, and surgical inflammation. However, the increased acquisition speed requires exceptional tissue stability to avoid imaging artefacts. Since respiratory motion is transmitted to the tissue under investigation, we have developed a relocation algorithm that removes motion artefacts from our intravital microscopy images. Using these techniques, we are now able to obtain more detailed 3D time-lapse images of the cremaster vascular microcirculation, which allow us to observe the process of leukocyte emigration into the surrounding tissue with increased temporal resolution in comparison to our previous confocal approach.
- Open Access
- 22 June 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (7) , 3927-3935
Planar Airy beam light-sheet for two-photon microscopy
We demonstrate the first planar Airy light-sheet microscope. Fluorescence light-sheet microscopy has become the method of choice to study large biological samples with cellular or sub-cellular resolution. The propagation-invariant Airy beam enables a ten-fold increase in field-of-view with single-photon excitation; however, the characteristic asymmetry of the light-sheet limits its potential for multi-photon excitation. Here we show how a planar light-sheet can be formed from the curved propagation-invariant Airy beam. The resulting symmetric light sheet excites two-photon fluorescence uniformly across an extended field-of-view without the need for deconvolution. We demonstrate the method for rapid two-photon imaging of large volumes of neuronal tissue.
- 22 June 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (7) , 3927-3935
Open AccessPlanar Airy beam light-sheet for two-photon microscopy
We demonstrate the first planar Airy light-sheet microscope. Fluorescence light-sheet microscopy has become the method of choice to study large biological samples with cellular or sub-cellular resolution. The propagation-invariant Airy beam enables a ten-fold increase in field-of-view with single-photon excitation; however, the characteristic asymmetry of the light-sheet limits its potential for multi-photon excitation. Here we show how a planar light-sheet can be formed from the curved propagation-invariant Airy beam. The resulting symmetric light sheet excites two-photon fluorescence uniformly across an extended field-of-view without the need for deconvolution. We demonstrate the method for rapid two-photon imaging of large volumes of neuronal tissue.
- Open Access
- 12 November 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 7 (2) , 1357-1367
Direct imaging of changes in aerosol particle viscosity upon hydration and chemical aging
We report quantitative, real-time, online observations of microscopic viscosity changes in aerosol particles of atmospherically relevant composition, using fluorescence lifetime imaging (FLIM) of viscosity.
- 12 November 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 7 (2) , 1357-1367
Open AccessDirect imaging of changes in aerosol particle viscosity upon hydration and chemical aging
We report quantitative, real-time, online observations of microscopic viscosity changes in aerosol particles of atmospherically relevant composition, using fluorescence lifetime imaging (FLIM) of viscosity.
- 16 February 2015
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 13 (12) , 3792-3802
Thiophene-based dyes for probing membranes
We report the synthesis of four new cationic dipolar push–pull dyes, together with an evaluation of their photophysical and photobiological characteristics pertinent to imaging membranes by fluorescence and second harmonic generation (SHG). All four dyes consist of an N,N-diethylaniline electron-donor conjugated to a pyridinium electron-acceptor via a thiophene bridge, with either vinylene (–CHCH–) or ethynylene (–CC–) linking groups, and with either singly-charged or doubly-charged pyridinium terminals. The absorption and fluorescence behavior of these dyes were compared to a commercially available fluorescent membrane stain, the styryl dye FM4-64. The hyperpolarizabilities of all dyes were compared using hyper-Rayleigh scattering at 800 nm. Cellular uptake, localization, toxicity and phototoxicity were evaluated using tissue cell cultures (HeLa, SK-OV-3 and MDA-231). Replacing the central alkene bridge of FM4-64 with a thiophene does not substantially change the absorption, fluorescence or hyperpolarizability, whereas changing the vinylene-links to ethynylenes shifts the absorption and fluorescence to shorter wavelengths, and reduces the hyperpolarizability by about a factor of two. SHG and fluorescence imaging experiments in live cells showed that the doubly-charged thiophene dyes localize in plasma membranes, and exhibit lower internalization rates compared to FM4-64, resulting in less signal from the cell cytosol. At a typical imaging concentration of 1 μM, the doubly-charged dyes showed no significant light or dark toxicity, whereas the singly-charged dyes are phototoxic even at 0.5 μM. The doubly-charged dyes showed phototoxicity at concentrations greater than 10 μM, although they do not generate singlet oxygen, indicating that the phototoxicity is type I rather than type II. The doubly-charged thiophene dyes are more effective than FM4-64 as SHG dyes for live cells.
- 16 February 2015
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 13 (12) , 3792-3802
Thiophene-based dyes for probing membranes
We report the synthesis of four new cationic dipolar push–pull dyes, together with an evaluation of their photophysical and photobiological characteristics pertinent to imaging membranes by fluorescence and second harmonic generation (SHG). All four dyes consist of an N,N-diethylaniline electron-donor conjugated to a pyridinium electron-acceptor via a thiophene bridge, with either vinylene (–CHCH–) or ethynylene (–CC–) linking groups, and with either singly-charged or doubly-charged pyridinium terminals. The absorption and fluorescence behavior of these dyes were compared to a commercially available fluorescent membrane stain, the styryl dye FM4-64. The hyperpolarizabilities of all dyes were compared using hyper-Rayleigh scattering at 800 nm. Cellular uptake, localization, toxicity and phototoxicity were evaluated using tissue cell cultures (HeLa, SK-OV-3 and MDA-231). Replacing the central alkene bridge of FM4-64 with a thiophene does not substantially change the absorption, fluorescence or hyperpolarizability, whereas changing the vinylene-links to ethynylenes shifts the absorption and fluorescence to shorter wavelengths, and reduces the hyperpolarizability by about a factor of two. SHG and fluorescence imaging experiments in live cells showed that the doubly-charged thiophene dyes localize in plasma membranes, and exhibit lower internalization rates compared to FM4-64, resulting in less signal from the cell cytosol. At a typical imaging concentration of 1 μM, the doubly-charged dyes showed no significant light or dark toxicity, whereas the singly-charged dyes are phototoxic even at 0.5 μM. The doubly-charged dyes showed phototoxicity at concentrations greater than 10 μM, although they do not generate singlet oxygen, indicating that the phototoxicity is type I rather than type II. The doubly-charged thiophene dyes are more effective than FM4-64 as SHG dyes for live cells.
- 1 November 2013
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1828 (11) , 2436-2443
Direct investigation of viscosity of an atypical inner membrane of Bacillus spores: A molecular rotor/FLIM study
- 1 November 2013
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1828 (11) , 2436-2443
Direct investigation of viscosity of an atypical inner membrane of Bacillus spores: A molecular rotor/FLIM study
- Open Access
- 9 October 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (10) , e74604
Super-Resolution Imaging Strategies for Cell Biologists Using a Spinning Disk Microscope
In this study we use a spinning disk confocal microscope (SD) to generate super-resolution images of multiple cellular features from any plane in the cell. We obtain super-resolution images by using stochastic intensity fluctuations of biological probes, combining Photoactivation Light-Microscopy (PALM)/Stochastic Optical Reconstruction Microscopy (STORM) methodologies. We compared different image analysis algorithms for processing super-resolution data to identify the most suitable for analysis of particular cell structures. SOFI was chosen for X and Y and was able to achieve a resolution of ca. 80 nm; however higher resolution was possible >30 nm, dependant on the super-resolution image analysis algorithm used. Our method uses low laser power and fluorescent probes which are available either commercially or through the scientific community, and therefore it is gentle enough for biological imaging. Through comparative studies with structured illumination microscopy (SIM) and widefield epifluorescence imaging we identified that our methodology was advantageous for imaging cellular structures which are not immediately at the cell-substrate interface, which include the nuclear architecture and mitochondria. We have shown that it was possible to obtain two coloured images, which highlights the potential this technique has for high-content screening, imaging of multiple epitopes and live cell imaging.
- 9 October 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (10) , e74604
Open AccessSuper-Resolution Imaging Strategies for Cell Biologists Using a Spinning Disk Microscope
In this study we use a spinning disk confocal microscope (SD) to generate super-resolution images of multiple cellular features from any plane in the cell. We obtain super-resolution images by using stochastic intensity fluctuations of biological probes, combining Photoactivation Light-Microscopy (PALM)/Stochastic Optical Reconstruction Microscopy (STORM) methodologies. We compared different image analysis algorithms for processing super-resolution data to identify the most suitable for analysis of particular cell structures. SOFI was chosen for X and Y and was able to achieve a resolution of ca. 80 nm; however higher resolution was possible >30 nm, dependant on the super-resolution image analysis algorithm used. Our method uses low laser power and fluorescent probes which are available either commercially or through the scientific community, and therefore it is gentle enough for biological imaging. Through comparative studies with structured illumination microscopy (SIM) and widefield epifluorescence imaging we identified that our methodology was advantageous for imaging cellular structures which are not immediately at the cell-substrate interface, which include the nuclear architecture and mitochondria. We have shown that it was possible to obtain two coloured images, which highlights the potential this technique has for high-content screening, imaging of multiple epitopes and live cell imaging.
- Open Access
- 20 May 2013
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 110 (23) , 9225-9230
Mapping microbubble viscosity using fluorescence lifetime imaging of molecular rotors
Encapsulated microbubbles are well established as highly effective contrast agents for ultrasound imaging. There remain, however, some significant challenges to fully realize the potential of microbubbles in advanced applications such as perfusion mapping, targeted drug delivery, and gene therapy. A key requirement is accurate characterization of the viscoelastic surface properties of the microbubbles, but methods for independent, nondestructive quantification and mapping of these properties are currently lacking. We present here a strategy for performing these measurements that uses a small fluorophore termed a “molecular rotor” embedded in the microbubble surface, whose fluorescence lifetime is directly related to the viscosity of its surroundings. We apply fluorescence lifetime imaging to show that shell viscosities vary widely across the population of the microbubbles and are influenced by the shell composition and the manufacturing process. We also demonstrate that heterogeneous viscosity distributions exist within individual microbubble shells even with a single surfactant component.
- 20 May 2013
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 110 (23) , 9225-9230
Open AccessMapping microbubble viscosity using fluorescence lifetime imaging of molecular rotors
Encapsulated microbubbles are well established as highly effective contrast agents for ultrasound imaging. There remain, however, some significant challenges to fully realize the potential of microbubbles in advanced applications such as perfusion mapping, targeted drug delivery, and gene therapy. A key requirement is accurate characterization of the viscoelastic surface properties of the microbubbles, but methods for independent, nondestructive quantification and mapping of these properties are currently lacking. We present here a strategy for performing these measurements that uses a small fluorophore termed a “molecular rotor” embedded in the microbubble surface, whose fluorescence lifetime is directly related to the viscosity of its surroundings. We apply fluorescence lifetime imaging to show that shell viscosities vary widely across the population of the microbubbles and are influenced by the shell composition and the manufacturing process. We also demonstrate that heterogeneous viscosity distributions exist within individual microbubble shells even with a single surfactant component.
- 8 April 2013
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 165, 343-356
Fluorescent lifetime imaging of atmospheric aerosols: a direct probe of aerosol viscosity
The viscosity of atmospheric aerosol particles affects a number of key physical and chemical particle properties, such as composition and reactivity. However, determination of the microscopic viscosity of aerosol particles is a non-trivial task. We report a new method of imaging viscosity in a variety of model aerosol systems, based on a fluorescence lifetime determination of viscosity-sensitive fluorophores termed molecular rotors. We report the viscosity changes associated with the relative humidity dependent hygroscopicity of NaCl and sucrose aerosols, as well as reaction dependent changes in viscosity during ozonolysis of oleic acid aerosols. The Fluorescence Lifetime Imaging Microscopy (FLIM) of molecular rotors shows great promise in understanding important fundamental aerosol properties, which can be both time-dependent and spatially variable through the aerosol particle.
- 8 April 2013
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 165, 343-356
Fluorescent lifetime imaging of atmospheric aerosols: a direct probe of aerosol viscosity
The viscosity of atmospheric aerosol particles affects a number of key physical and chemical particle properties, such as composition and reactivity. However, determination of the microscopic viscosity of aerosol particles is a non-trivial task. We report a new method of imaging viscosity in a variety of model aerosol systems, based on a fluorescence lifetime determination of viscosity-sensitive fluorophores termed molecular rotors. We report the viscosity changes associated with the relative humidity dependent hygroscopicity of NaCl and sucrose aerosols, as well as reaction dependent changes in viscosity during ozonolysis of oleic acid aerosols. The Fluorescence Lifetime Imaging Microscopy (FLIM) of molecular rotors shows great promise in understanding important fundamental aerosol properties, which can be both time-dependent and spatially variable through the aerosol particle.
- 1 January 2013
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 19 (1) , 075017
Investigating the effect of fabrication method on the stability and acoustic response of microbubble agents
Microbubbles stabilized by a surfactant or polymer coating are already in clinical use as ultrasound imaging contrast agents. They have also been widely investigated as vehicles for drug delivery and gene therapy that can be tracked and triggered using ultrasound. Extensive studies have been made of the effects of the coating material and gas core on microbubble characteristics but the influence of the fabrication method has received less attention. The aim of this study was to compare the behavior of microbubbles prepared using different techniques. Phospholipid-coated microbubbles were produced using sonication, electrospraying or in a specially designed microfluidic device. The microbubbles were observed using optical, electron and fluorescence lifetime imaging microscopy (FLIM) to interrogate their surface microstructure and stability over time. Their acoustic response was then determined in a flow chamber by detecting the pressure scattered from individual microbubbles as they passed through the focal region of a transducer (centre frequencies 1, 2.25 and 3.5 MHz; peak negative pressures 50-300kPa). The method of bubble generation was found to significantly affect the bubble surface characteristics, stability and acoustic response. The results demonstrate that the processing method affects not only the bubble size distribution but other characteristics important for biomedical applications.
- 1 January 2013
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 19 (1) , 075017
Investigating the effect of fabrication method on the stability and acoustic response of microbubble agents
Microbubbles stabilized by a surfactant or polymer coating are already in clinical use as ultrasound imaging contrast agents. They have also been widely investigated as vehicles for drug delivery and gene therapy that can be tracked and triggered using ultrasound. Extensive studies have been made of the effects of the coating material and gas core on microbubble characteristics but the influence of the fabrication method has received less attention. The aim of this study was to compare the behavior of microbubbles prepared using different techniques. Phospholipid-coated microbubbles were produced using sonication, electrospraying or in a specially designed microfluidic device. The microbubbles were observed using optical, electron and fluorescence lifetime imaging microscopy (FLIM) to interrogate their surface microstructure and stability over time. Their acoustic response was then determined in a flow chamber by detecting the pressure scattered from individual microbubbles as they passed through the focal region of a transducer (centre frequencies 1, 2.25 and 3.5 MHz; peak negative pressures 50-300kPa). The method of bubble generation was found to significantly affect the bubble surface characteristics, stability and acoustic response. The results demonstrate that the processing method affects not only the bubble size distribution but other characteristics important for biomedical applications.
- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (1) , 0160071-01600712
Single photon counting fluorescence lifetime detection of pericellular oxygen concentrations
Fluorescence lifetime imaging microscopy offers a non-invasive method for quantifying local oxygen concentrations. However, existing methods are either invasive, require custom-made systems, or show limited spatial resolution. Therefore, these methods are unsuitable for investigation of pericellular oxygen concentrations. This study describes an adaptation of commercially available equipment which has been optimized for quantitative extracellular oxygen detection with high lifetime accuracy and spatial resolution while avoiding systematic photon pile-up. The oxygen sensitive fluorescent dye, tris(2,2’-bipyridyl)ruthenium(II) chloride hexahydrate , was excited using a two-photon excitation laser. Lifetime was measured using a Becker & Hickl time-correlated single photon counting, which will be referred to as a TCSPC card. characterization studies quantified the influences of temperature, pH, cellular culture media and oxygen on the fluorescence lifetime measurements. This provided a precisely calibrated and accurate system for quantification of pericellular oxygen concentration based on measured lifetimes. Using this technique, quantification of oxygen concentrations around isolated viable chondrocytes, seeded in three-dimensional agarose gel, revealed a subpopulation of cells that exhibited significant spatial oxygen gradients such that oxygen concentration reduced with increasing proximity to the cell. This technique provides a powerful tool for quantifying spatial oxygen gradients within three-dimensional cellular models.- 1 January 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (1) , 0160071-01600712
Single photon counting fluorescence lifetime detection of pericellular oxygen concentrations
Fluorescence lifetime imaging microscopy offers a non-invasive method for quantifying local oxygen concentrations. However, existing methods are either invasive, require custom-made systems, or show limited spatial resolution. Therefore, these methods are unsuitable for investigation of pericellular oxygen concentrations. This study describes an adaptation of commercially available equipment which has been optimized for quantitative extracellular oxygen detection with high lifetime accuracy and spatial resolution while avoiding systematic photon pile-up. The oxygen sensitive fluorescent dye, tris(2,2’-bipyridyl)ruthenium(II) chloride hexahydrate , was excited using a two-photon excitation laser. Lifetime was measured using a Becker & Hickl time-correlated single photon counting, which will be referred to as a TCSPC card. characterization studies quantified the influences of temperature, pH, cellular culture media and oxygen on the fluorescence lifetime measurements. This provided a precisely calibrated and accurate system for quantification of pericellular oxygen concentration based on measured lifetimes. Using this technique, quantification of oxygen concentrations around isolated viable chondrocytes, seeded in three-dimensional agarose gel, revealed a subpopulation of cells that exhibited significant spatial oxygen gradients such that oxygen concentration reduced with increasing proximity to the cell. This technique provides a powerful tool for quantifying spatial oxygen gradients within three-dimensional cellular models.