Pattrick Calderoni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pattrick Calderoni has a total of 300 co-authors. Here are the top co-authors by number of shared publications:
- Masashi Shimada
Idaho National Laboratory
10 shared publications I. Ricapito
6 shared publicationsA. Ying
University of California, Los Angeles, 44-136 Eng. IV, Box 951597 Los Angeles, CA 90095-159, USA
5 shared publicationsM.A. Abdou
5 shared publicationsA. Aiello
4 shared publicationsM. Abdou
University of California, Los Angeles, CA, USA
4 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Advanced tritium transport modeling and verification, validation, and benchmarking from component level to fuel cycle scale using TMAP8
- 16 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 234
Open AccessAdvanced tritium transport modeling and verification, validation, and benchmarking from component level to fuel cycle scale using TMAP8
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 5511-5517
Neutron Irradiation Experiments to Support Fusion Blanket Development
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 5511-5517
Neutron Irradiation Experiments to Support Fusion Blanket Development
- Open Access
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 15501-15516
Constrained Optimization of Sensor Placement for Nuclear Digital Twins
The deployment of extensive sensor arrays in nuclear reactors is infeasible due to challenging operating conditions and inherent spatial limitations. Strategically placing sensors within defined spatial constraints is essential for the reconstruction of reactor flow fields and the creation of nuclear digital twins. We develop a data-driven technique that incorporates constraints into an optimization framework for sensor placement, with the primary objective of minimizing reconstruction errors under noisy sensor measurements. The proposed greedy algorithm optimizes sensor locations over high-dimensional grids, adhering to user-specified constraints. We demonstrate the efficacy of optimized sensors by exhaustively computing all feasible configurations for a low-dimensional dynamical system. To validate our methodology, we apply the algorithm to the Out-of-Pile Testing and Instrumentation Transient Water Irradiation System (OPTI-TWIST) prototype capsule. This capsule is electrically heated to emulate the neutronic effect of the nuclear fuel. The TWIST prototype that will eventually be inserted in the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory (INL), serves as a practical demonstration. The resulting sensor-based temperature reconstruction within OPTI-TWIST demonstrates minimized error, provides probabilistic bounds for noise-induced uncertainty, and establishes a foundation for communication between the digital twin and the experimental facility.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 15501-15516
Open AccessConstrained Optimization of Sensor Placement for Nuclear Digital Twins
The deployment of extensive sensor arrays in nuclear reactors is infeasible due to challenging operating conditions and inherent spatial limitations. Strategically placing sensors within defined spatial constraints is essential for the reconstruction of reactor flow fields and the creation of nuclear digital twins. We develop a data-driven technique that incorporates constraints into an optimization framework for sensor placement, with the primary objective of minimizing reconstruction errors under noisy sensor measurements. The proposed greedy algorithm optimizes sensor locations over high-dimensional grids, adhering to user-specified constraints. We demonstrate the efficacy of optimized sensors by exhaustively computing all feasible configurations for a low-dimensional dynamical system. To validate our methodology, we apply the algorithm to the Out-of-Pile Testing and Instrumentation Transient Water Irradiation System (OPTI-TWIST) prototype capsule. This capsule is electrically heated to emulate the neutronic effect of the nuclear fuel. The TWIST prototype that will eventually be inserted in the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory (INL), serves as a practical demonstration. The resulting sensor-based temperature reconstruction within OPTI-TWIST demonstrates minimized error, provides probabilistic bounds for noise-induced uncertainty, and establishes a foundation for communication between the digital twin and the experimental facility.
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (9) , 2007-2017
A Two-Cycle Automated Approach to Electrical Resistivity Measurement of SiC Monitors for Peak Irradiation Temperature
An experimental system was designed and optimized to acquire real-time electrical resistance of the monitors during annealing. The system was then used to anneal irradiated SiC monitors. The altered resistance of the SiC monitors between the first heating cycle and the mean of the heating and cooling cycles that followed was found to significantly change when the annealing temperature exceeded the peak irradiation temperature. This was validated using nine irradiated SiC monitors annealed over two heating and cooling cycles. Of these SiC monitors, three were annealed for the first time,. The remaining six monitors were already annealed, but four of these were found to contain residual defects that resulted in reasonable estimates of peak irradiation temperatures. Those estimated peak irradiation temperatures were statistically indifferent from the manual isochronal annealing method temperatures. The results demonstrate a preliminary potential for the two-cycle approach to replace or augment the current manual PIE process for extracting SiC monitor peak irradiation temperature.
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (9) , 2007-2017
A Two-Cycle Automated Approach to Electrical Resistivity Measurement of SiC Monitors for Peak Irradiation Temperature
An experimental system was designed and optimized to acquire real-time electrical resistance of the monitors during annealing. The system was then used to anneal irradiated SiC monitors. The altered resistance of the SiC monitors between the first heating cycle and the mean of the heating and cooling cycles that followed was found to significantly change when the annealing temperature exceeded the peak irradiation temperature. This was validated using nine irradiated SiC monitors annealed over two heating and cooling cycles. Of these SiC monitors, three were annealed for the first time,. The remaining six monitors were already annealed, but four of these were found to contain residual defects that resulted in reasonable estimates of peak irradiation temperatures. Those estimated peak irradiation temperatures were statistically indifferent from the manual isochronal annealing method temperatures. The results demonstrate a preliminary potential for the two-cycle approach to replace or augment the current manual PIE process for extracting SiC monitor peak irradiation temperature.
- 26 March 2020
- Published by Office of Scientific and Technical Information (OSTI)
Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry
The U.S. Department of Energy's Office of Scientific and Technical Information
- 26 March 2020
- Published by Office of Scientific and Technical Information (OSTI)
Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 5 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 585-591
Evaluation of Low Dose Silicon Carbide Temperature Monitors
- 5 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (4) , 585-591
Open AccessEvaluation of Low Dose Silicon Carbide Temperature Monitors
- 29 May 2019
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 47 (6) , 611-626
An impedance-based diameter gauge for in-pile fuel deformation measurements
During irradiation, the fuel-cladding interface of a nuclear fuel rod can experience significant mechanical and chemical interaction. In-situ measurement of the radial deformation of the cladding can quantify the extent of this interaction and the state of the cladding. Existing capabilities to perform in-pile diameter measurements are limited by required contact and an intrusive presence of a device near to a specimen. To overcome these limitations, researchers have developed and evaluated an electrical impedance based diameter gauge using a benchtop system. The sensor consists of an electrically conductive concentric ring around the fuel cladding such that the electrical impedance between the ring and cladding is measured. The cladding diameter is determined through a measurement of the electrical impedance between the electrodes with a known ring electrode diameter. Analytic and three-dimensional finite element analyses (FEA) were used to quantify the measurement sensitivity, uncertainty, and off-design conditions. The experimental sensor measured diameters with less than 20 μm of error, and had a measurement resolution of less than1 μm for diameters ranging from 9.5 to 9.6 mm. The uncertainty analysis for the experimental setup estimated an uncertainty of 20 μm, consistent with the experimentally measured results.
- 29 May 2019
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 47 (6) , 611-626
An impedance-based diameter gauge for in-pile fuel deformation measurements
During irradiation, the fuel-cladding interface of a nuclear fuel rod can experience significant mechanical and chemical interaction. In-situ measurement of the radial deformation of the cladding can quantify the extent of this interaction and the state of the cladding. Existing capabilities to perform in-pile diameter measurements are limited by required contact and an intrusive presence of a device near to a specimen. To overcome these limitations, researchers have developed and evaluated an electrical impedance based diameter gauge using a benchtop system. The sensor consists of an electrically conductive concentric ring around the fuel cladding such that the electrical impedance between the ring and cladding is measured. The cladding diameter is determined through a measurement of the electrical impedance between the electrodes with a known ring electrode diameter. Analytic and three-dimensional finite element analyses (FEA) were used to quantify the measurement sensitivity, uncertainty, and off-design conditions. The experimental sensor measured diameters with less than 20 μm of error, and had a measurement resolution of less than1 μm for diameters ranging from 9.5 to 9.6 mm. The uncertainty analysis for the experimental setup estimated an uncertainty of 20 μm, consistent with the experimentally measured results.
- 7 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
Evaluation of a Versatile Experimental Salt Irradiation Loop (VESIL) inside the Advanced Test Reactor
The U.S. Department of Energy's Office of Scientific and Technical Information
- 7 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
Evaluation of a Versatile Experimental Salt Irradiation Loop (VESIL) inside the Advanced Test Reactor
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 January 2018
- Published by Optica Publishing Group
- p. WF56
On-line monitoring of multiplexed femtosecond Fiber Bragg Gratings exposed to high temperature and high neutron fluence
We have monitored on-line the spectral characteristics of two lines of five multiplexed Fiber Bragg Gratings under high temperature and high neutron fluence (up to 670°C and 3×1019 nfast/cm2>1Mev). The gratings have been written using a femtosecond laser and the point-by-point technique onto pure silica core (PSC) single-mode fibers. This paper details the evolution of the Bragg wavelength shifts (BWS) during the irradiation conducted at the MIT Nuclear Research Reactor.
- 1 January 2018
- Published by Optica Publishing Group
- p. WF56
On-line monitoring of multiplexed femtosecond Fiber Bragg Gratings exposed to high temperature and high neutron fluence
We have monitored on-line the spectral characteristics of two lines of five multiplexed Fiber Bragg Gratings under high temperature and high neutron fluence (up to 670°C and 3×1019 nfast/cm2>1Mev). The gratings have been written using a femtosecond laser and the point-by-point technique onto pure silica core (PSC) single-mode fibers. This paper details the evolution of the Bragg wavelength shifts (BWS) during the irradiation conducted at the MIT Nuclear Research Reactor.
- 15 December 2017
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 46 (4) , 349-363
Optimization of heat treatment and calibration procedures for high temperature irradiation resistant thermocouples
A detailed description is provided for the optimization of heat treatment and calibrating procedure for Idaho National Laboratory’s high temperature irradiation resistant thermocouples (HTIR-TC). Also discussed is the implication of the procedures on the overall performance of the HTIR-TC finished product; in particular, for the case of long lead sections that are typical of sensors deployed in nuclear reactors. The effect on the measurement accuracy of fluctuations of the reference temperature and localized heating along the sensor lead is also investigated. A calibration graphical user interface (GUI) and accompanying script is presented for unifying the calibration process. A fifth-order polynomial function was found to be best for fitting HTIR-TC calibration data. The performance of the HTIR-TCs subject to the optimized heat treatment and calibration procedures is shown to be robust and consistent with other TC industry standards. Electromotive force curves versus length of the TC are presented to clarify positioning of TCs in general and how its effect on the calibrated temperatures.
- 15 December 2017
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 46 (4) , 349-363
Optimization of heat treatment and calibration procedures for high temperature irradiation resistant thermocouples
A detailed description is provided for the optimization of heat treatment and calibrating procedure for Idaho National Laboratory’s high temperature irradiation resistant thermocouples (HTIR-TC). Also discussed is the implication of the procedures on the overall performance of the HTIR-TC finished product; in particular, for the case of long lead sections that are typical of sensors deployed in nuclear reactors. The effect on the measurement accuracy of fluctuations of the reference temperature and localized heating along the sensor lead is also investigated. A calibration graphical user interface (GUI) and accompanying script is presented for unifying the calibration process. A fifth-order polynomial function was found to be best for fitting HTIR-TC calibration data. The performance of the HTIR-TCs subject to the optimized heat treatment and calibration procedures is shown to be robust and consistent with other TC industry standards. Electromotive force curves versus length of the TC are presented to clarify positioning of TCs in general and how its effect on the calibrated temperatures.