Xu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xu Chen has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Steen Pehrson
Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Inge LehmannsVej 7, Copenhagen, Denmark
9 shared publicationsPeter Karl Jacobsen
Department of Cardiology The Heart Centre Rigshospitalet Copenhagen University Hospital Copenhagen Denmark
8 shared publicationsQi Jin
Department of Cardiology, The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
3 shared publications- Steen Pehrson
Department of Cardiology, University Hospital, Rigshospitalet, Copenhagen, Denmark (S.P.).
3 shared publications - Christian Jons
Department of Cardiology, The Heart Centre, Copenhagen University Hospital—Rigshospitalet , Copenhagen
2 shared publications - Jesper Hastrup Svendsen
Department of Cardiology, Copenhagen University Hospital – Rigshospitalet , Copenhagen
2 shared publications
Latest Publications
- Open Access
- 1 February 2022
- Published by Hindawi Limited in Journal of Interventional Cardiology
- Vol. 2022, 1-7
Comparison of the Anterior Septal Line and Mitral Isthmus Line for Perimitral Atrial Flutter Ablation Using Robotic Magnetic Navigation
Background. Perimitral atrial flutter (PMAFL) is one of the most common macro-reentrant left atrial tachycardias. Mitral isthmus (MI) linear ablation is a common strategy for the treatment of PMAFLs, and anterior septum (AS) linear ablation has emerged as a novel ablation approach. We aimed at assessing the effectiveness of AS linear ablation using robotic magnetic navigation for PMAFL ablation. Methods. In this retrospective study, a total of 36 consecutive patients presented with AFL as the unique arrhythmia or accompanied with atrial fibrillation (AF) who underwent catheter ablation were enrolled. Patients were classified into two groups according to the different ablation strategies, the MI line group (10 patients) and the AS line group (26 patients). Results. The clinical baseline characteristics of patients in the two groups were nearly identical. There were no significant differences in procedure time (148.7 ± 46.1 vs. 123.2 ± 30.1 min, ) or radiofrequency ablation time (25.9 ± 11.4 vs. 23.5 ± 12.6 min) between the two groups. Fluoroscopy time was longer in the MI line group (8.0 ± 4.4 vs. 5.1 ± 2.7 min, ), and the acute success rate was higher in the AS line group versus the MI line group (96.2% vs. 70%, ). The long-term freedom from arrhythmia survival rate was higher in the AS line group (73%) than in the MI line group (40%) after a mean follow-up time of 37.4 months with a 3-month blanking period ( ). Conclusions. AS linear ablation is an effective and safe strategy for PMAFL ablation using robotic magnetic navigation.
- 1 February 2022
- Published by Hindawi Limited in Journal of Interventional Cardiology
- Vol. 2022, 1-7
Open AccessComparison of the Anterior Septal Line and Mitral Isthmus Line for Perimitral Atrial Flutter Ablation Using Robotic Magnetic Navigation
Background. Perimitral atrial flutter (PMAFL) is one of the most common macro-reentrant left atrial tachycardias. Mitral isthmus (MI) linear ablation is a common strategy for the treatment of PMAFLs, and anterior septum (AS) linear ablation has emerged as a novel ablation approach. We aimed at assessing the effectiveness of AS linear ablation using robotic magnetic navigation for PMAFL ablation. Methods. In this retrospective study, a total of 36 consecutive patients presented with AFL as the unique arrhythmia or accompanied with atrial fibrillation (AF) who underwent catheter ablation were enrolled. Patients were classified into two groups according to the different ablation strategies, the MI line group (10 patients) and the AS line group (26 patients). Results. The clinical baseline characteristics of patients in the two groups were nearly identical. There were no significant differences in procedure time (148.7 ± 46.1 vs. 123.2 ± 30.1 min, ) or radiofrequency ablation time (25.9 ± 11.4 vs. 23.5 ± 12.6 min) between the two groups. Fluoroscopy time was longer in the MI line group (8.0 ± 4.4 vs. 5.1 ± 2.7 min, ), and the acute success rate was higher in the AS line group versus the MI line group (96.2% vs. 70%, ). The long-term freedom from arrhythmia survival rate was higher in the AS line group (73%) than in the MI line group (40%) after a mean follow-up time of 37.4 months with a 3-month blanking period ( ). Conclusions. AS linear ablation is an effective and safe strategy for PMAFL ablation using robotic magnetic navigation.
- 22 June 2020
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 60 (2) , 349-351
Challenges in catheter ablation of deep myocardial substrate for ventricular tachycardia
- 22 June 2020
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 60 (2) , 349-351
Challenges in catheter ablation of deep myocardial substrate for ventricular tachycardia
- Open Access
- 31 January 2019
- Published by Wiley in Journal of Arrhythmia
- Vol. 35 (2) , 244-251
Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions
Background: Remote magnetic navigation (RMN) is often used in combination with a 3‐dimensional mapping system to perform catheter ablations. This study aim to investigate the feasibility and effectiveness of a novel 3D‐mapping system, EnSite Precision, combined with RMN for catheter ablation of premature ventricular contractions (PVCs), and compared it to the procedures performed by CARTO3 with RMN.Methods: Forty‐three consecutive PVC patients were either ablated with the guidance of EnSite Precision (n = 22) or CARTO (n = 21) navigated by RMN. Procedure‐related details, acute and long‐term success were assessed.Results: Patient characteristics between both the groups were similar (age: 47.1 ± 19.8 vs 47.1 ± 12.7, female: 63.6% vs 57.1%). No significant difference was found in the procedure time (99.5 ± 30.4 vs 92.9 ± 24.8 min, P = 0.436), mapping time (18.6 ± 12.8 vs 15.5 ± 10.2 min, P = 0.390), radiofrequency ablation time (333.4 ± 267.0 vs 469.3 ± 343.1 s, P = 0.154), fluoroscopy time (4.0 ± 1.9 vs 3.8 ± 2.0 min, P = 0.635), and X‐ray dose (1.8 ± 1.4 vs 2.0 ± 1.2 Gycm2, P = 0.649) between the two groups. No significant procedural complication occurred in either group. In addition, there was no significant differences regarding the acute success rate (90.9% vs 90.5%, P = 0.961) and long‐term success rate (86.4% vs 81.0%, P = 0.631) after 16.2 ± 6.2 months of follow‐up between the two groups.Conclusions: RMN combined with EnSite Precision mapping system is effective and safe for catheter ablation of PVCs.
- 31 January 2019
- Published by Wiley in Journal of Arrhythmia
- Vol. 35 (2) , 244-251
Open AccessFeasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions
Background: Remote magnetic navigation (RMN) is often used in combination with a 3‐dimensional mapping system to perform catheter ablations. This study aim to investigate the feasibility and effectiveness of a novel 3D‐mapping system, EnSite Precision, combined with RMN for catheter ablation of premature ventricular contractions (PVCs), and compared it to the procedures performed by CARTO3 with RMN.Methods: Forty‐three consecutive PVC patients were either ablated with the guidance of EnSite Precision (n = 22) or CARTO (n = 21) navigated by RMN. Procedure‐related details, acute and long‐term success were assessed.Results: Patient characteristics between both the groups were similar (age: 47.1 ± 19.8 vs 47.1 ± 12.7, female: 63.6% vs 57.1%). No significant difference was found in the procedure time (99.5 ± 30.4 vs 92.9 ± 24.8 min, P = 0.436), mapping time (18.6 ± 12.8 vs 15.5 ± 10.2 min, P = 0.390), radiofrequency ablation time (333.4 ± 267.0 vs 469.3 ± 343.1 s, P = 0.154), fluoroscopy time (4.0 ± 1.9 vs 3.8 ± 2.0 min, P = 0.635), and X‐ray dose (1.8 ± 1.4 vs 2.0 ± 1.2 Gycm2, P = 0.649) between the two groups. No significant procedural complication occurred in either group. In addition, there was no significant differences regarding the acute success rate (90.9% vs 90.5%, P = 0.961) and long‐term success rate (86.4% vs 81.0%, P = 0.631) after 16.2 ± 6.2 months of follow‐up between the two groups.Conclusions: RMN combined with EnSite Precision mapping system is effective and safe for catheter ablation of PVCs.
- Open Access
- 1 May 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_2) , ii33-ii39
Catheter ablation of incisional atrial tachycardia using remote magnetic navigation in patients after heart surgery: comparison between acquired and congenital heart disease
The objectives of this study were to assess the acute and long-term outcomes of catheter ablation in incisional atrial tachycardia (IAT) using remote magnetic navigation (RMN) in patients after heart surgery. A total of 46 patients with IAT after heart surgery who underwent catheter ablation using RMN were included. Of these patients, 22 patients had acquired heart disease (AHD) and the remaining 24 patients had various types of congenital heart disease (CHD). In these 46 patients, 57 re-entry circuits were found in 56 procedures. The re-entry circuits were mainly distributed in right atrium (RA). Acute success of first ablation reached in 42 of 46 (91%) patients. Mean procedure duration was 115 ± 39 min, ablation duration was 678 (920.5) s, X-ray time was 4 (4.8) min, and X-ray dose was 3 (6.0) gy cm2. After a mean follow-up of 28 ± 19 months, 39 of 46 (85%) patients were free from IAT. No major complications were observed. There were no significant differences in procedure durations (AHD 113 ± 40 min vs. CHD 119 ± 38 min), ablation durations [AHD 643 (1027) s vs. CHD 712 (929) s], X-ray time [AHD 4 (4.5) min vs. CHD 4 (5.0) min], circuits in RA (AHD 85% vs. CHD 86%), acute success rates (AHD 91% vs. CHD 92%), and long-term success rates (AHD 86% vs. CHD 83%) between the two groups (P > 0.05). Catheter ablation of IAT in patients after heart surgery using RMN is safe and effective. No significant differences related to success rates and procedure characteristics were found between patients with AHD and CHD.
- 1 May 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (suppl_2) , ii33-ii39
Open AccessCatheter ablation of incisional atrial tachycardia using remote magnetic navigation in patients after heart surgery: comparison between acquired and congenital heart disease
The objectives of this study were to assess the acute and long-term outcomes of catheter ablation in incisional atrial tachycardia (IAT) using remote magnetic navigation (RMN) in patients after heart surgery. A total of 46 patients with IAT after heart surgery who underwent catheter ablation using RMN were included. Of these patients, 22 patients had acquired heart disease (AHD) and the remaining 24 patients had various types of congenital heart disease (CHD). In these 46 patients, 57 re-entry circuits were found in 56 procedures. The re-entry circuits were mainly distributed in right atrium (RA). Acute success of first ablation reached in 42 of 46 (91%) patients. Mean procedure duration was 115 ± 39 min, ablation duration was 678 (920.5) s, X-ray time was 4 (4.8) min, and X-ray dose was 3 (6.0) gy cm2. After a mean follow-up of 28 ± 19 months, 39 of 46 (85%) patients were free from IAT. No major complications were observed. There were no significant differences in procedure durations (AHD 113 ± 40 min vs. CHD 119 ± 38 min), ablation durations [AHD 643 (1027) s vs. CHD 712 (929) s], X-ray time [AHD 4 (4.5) min vs. CHD 4 (5.0) min], circuits in RA (AHD 85% vs. CHD 86%), acute success rates (AHD 91% vs. CHD 92%), and long-term success rates (AHD 86% vs. CHD 83%) between the two groups (P > 0.05). Catheter ablation of IAT in patients after heart surgery using RMN is safe and effective. No significant differences related to success rates and procedure characteristics were found between patients with AHD and CHD.
- 1 April 2018
- Vol. 30 (4) , 126-132
Catheter Ablation of Focal Atrial Tachycardia Using Remote Magnetic Navigation
Objectives. The outcomes of catheter ablation in focal atrial tachycardia (AT) using remote magnetic navigation (RMN) are still controversial. The objectives of this study were to assess the acute and long-term outcomes of catheter ablation in focal AT using RMN. Background. A total of 53 patients with focal AT who underwent catheter ablation using RMN were included. Thirty-six patients had structural heart disease, including previous atrial fibrillation ablation and heart surgery (abnormal group), and the remaining 17 patients had no structural heart disease (normal group). Methods. In 53 patients, a total of 56 atrial foci were found. Acute success of the primary ablation was obtained in 52 patients (98%). Mean procedure duration was 109 +/- 35 min, ablation duration was 401 sec (interquartile range [IQR], 332 sec), and fluoroscopy time was 5.0 min [IQR, 3.0 min]. After a mean follow-up of 31 +/- 18 months, 47 patients (89%) were free from focal AT. No major complications were observed. In the abnormal group, age and target atrium volume were higher and the left ventricular ejection fraction was lower when compared to the normal group. However, there were no significant differences in procedure duration (normal group 106 +/- 31 min vs abnormal group 111 +/- 37 min); ablation duration (normal group 457 sec [IQR, 412 sec] vs abnormal group 378 sec [IQR, 217 sec]); fluoroscopy time (normal group 4.2 min [IQR, 3.0 min] vs abnormal group 5.4 min [IQR, 3.3 min]); acute success rate (normal group 100% vs abnormal group 97%); and long-term success rate (normal group 88% vs abnormal group 89%) between the two groups (P>.05). Conclusion. Our study has demonstrated that catheter ablation of focal AT using RMN is safe and effective, with low fluoroscopy exposure.
- 1 April 2018
- Vol. 30 (4) , 126-132
Catheter Ablation of Focal Atrial Tachycardia Using Remote Magnetic Navigation
Objectives. The outcomes of catheter ablation in focal atrial tachycardia (AT) using remote magnetic navigation (RMN) are still controversial. The objectives of this study were to assess the acute and long-term outcomes of catheter ablation in focal AT using RMN. Background. A total of 53 patients with focal AT who underwent catheter ablation using RMN were included. Thirty-six patients had structural heart disease, including previous atrial fibrillation ablation and heart surgery (abnormal group), and the remaining 17 patients had no structural heart disease (normal group). Methods. In 53 patients, a total of 56 atrial foci were found. Acute success of the primary ablation was obtained in 52 patients (98%). Mean procedure duration was 109 +/- 35 min, ablation duration was 401 sec (interquartile range [IQR], 332 sec), and fluoroscopy time was 5.0 min [IQR, 3.0 min]. After a mean follow-up of 31 +/- 18 months, 47 patients (89%) were free from focal AT. No major complications were observed. In the abnormal group, age and target atrium volume were higher and the left ventricular ejection fraction was lower when compared to the normal group. However, there were no significant differences in procedure duration (normal group 106 +/- 31 min vs abnormal group 111 +/- 37 min); ablation duration (normal group 457 sec [IQR, 412 sec] vs abnormal group 378 sec [IQR, 217 sec]); fluoroscopy time (normal group 4.2 min [IQR, 3.0 min] vs abnormal group 5.4 min [IQR, 3.3 min]); acute success rate (normal group 100% vs abnormal group 97%); and long-term success rate (normal group 88% vs abnormal group 89%) between the two groups (P>.05). Conclusion. Our study has demonstrated that catheter ablation of focal AT using RMN is safe and effective, with low fluoroscopy exposure.
- 1 October 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 120 (8) , 1309-1315
Natriuretic Propeptides as Markers of Atrial Fibrillation Burden and Recurrence (from the AMIO-CAT Trial)
- 1 October 2017
- Published by Elsevier in The American Journal of Cardiology
- Vol. 120 (8) , 1309-1315
Natriuretic Propeptides as Markers of Atrial Fibrillation Burden and Recurrence (from the AMIO-CAT Trial)
- 1 September 2017
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 28 (12) , 1387-1392
Initial experience of a novel mapping system combined with remote magnetic navigation in the catheter ablation of atrial fibrillation
Background: There have been advancements of sophisticated mapping systems used for ablation procedures over the last decade. Utilization of these novel mapping systems in combination with remote magnetic navigation (RMN) needs to be established. We investigated the new EnSite Precision mapping system (St. Jude Medical, Inc., St. Paul, MN, USA), which collects magnetic data for checking navigation field stability and is built on an open platform, allowing physicians to choose diagnostic and ablation catheters. We address its compatibility with RMN.Objective: To assess the clinical utility of a novel 3D mapping system (EnSite Precision mapping system) combined with RMN (Niobe ES, Stereotaxis, Inc., St. Louis, MO, USA) for atrial fibrillation (AF) ablation.Methods: In this prospective nonrandomized study, two groups of patients were treated in our center for drug refractory AF. Patients were consecutively enrolled in each group. Group A (n = 35, 14 persistent AF [PsAF]) was treated using the novel 3D mapping system combined with RMN. Group B (n = 38, 16 PsAF) was treated using Carto®3 (Biosense Webster, Inc., Diamond Bar, CA, USA) combined with RMN. In Group A, the left atrium (LA) was mapped with a circular magnetic catheter manually and was then replaced by a RMN ablation catheter. At the end of the procedures in Group A, the circular catheter was used for confirming field stability. In Group B, an ablation catheter was controlled by RMN to perform both LA mapping and ablation. All patients underwent pulmonary vein antrum isolation. Additional complex fractionated atrial electrograms (CFAEs) ablation was performed for PsAF. Procedural, ablation, and fluoroscopy times were recorded and complications were assessed.Results: Electrophysiological end points were achieved in all patients. Using the novel mapping system, LA mapping time was fast (308 ± 60 seconds) with detailed anatomy points (178,831 ± 70,897) collected and magnetic points throughout LA. At the end of the procedures in Group A, the LA model was confirmed to be stable and its location was within the distance threshold (1 mm). Procedure time (117.9 ± 29.6 minutes vs. 119.2 ± 29.7 minutes, P = 0.89), fluoroscopy time (6.1 ± 2.4 minutes vs. 4.8 ± 2.2 minutes, P = 0.07), and ablation time (28.0 ± 12.9 minutes vs. 27.9 ± 15.8 minutes, P = 0.98) were similar in Group A versus Group B, respectively. No complications occurred in either group.Conclusions: LA mapped by the novel system is stable and reliable. Combined with RMN, it could be effectively used for AF ablation without impacting overall procedural times.
- 1 September 2017
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 28 (12) , 1387-1392
Initial experience of a novel mapping system combined with remote magnetic navigation in the catheter ablation of atrial fibrillation
Background: There have been advancements of sophisticated mapping systems used for ablation procedures over the last decade. Utilization of these novel mapping systems in combination with remote magnetic navigation (RMN) needs to be established. We investigated the new EnSite Precision mapping system (St. Jude Medical, Inc., St. Paul, MN, USA), which collects magnetic data for checking navigation field stability and is built on an open platform, allowing physicians to choose diagnostic and ablation catheters. We address its compatibility with RMN.Objective: To assess the clinical utility of a novel 3D mapping system (EnSite Precision mapping system) combined with RMN (Niobe ES, Stereotaxis, Inc., St. Louis, MO, USA) for atrial fibrillation (AF) ablation.Methods: In this prospective nonrandomized study, two groups of patients were treated in our center for drug refractory AF. Patients were consecutively enrolled in each group. Group A (n = 35, 14 persistent AF [PsAF]) was treated using the novel 3D mapping system combined with RMN. Group B (n = 38, 16 PsAF) was treated using Carto®3 (Biosense Webster, Inc., Diamond Bar, CA, USA) combined with RMN. In Group A, the left atrium (LA) was mapped with a circular magnetic catheter manually and was then replaced by a RMN ablation catheter. At the end of the procedures in Group A, the circular catheter was used for confirming field stability. In Group B, an ablation catheter was controlled by RMN to perform both LA mapping and ablation. All patients underwent pulmonary vein antrum isolation. Additional complex fractionated atrial electrograms (CFAEs) ablation was performed for PsAF. Procedural, ablation, and fluoroscopy times were recorded and complications were assessed.Results: Electrophysiological end points were achieved in all patients. Using the novel mapping system, LA mapping time was fast (308 ± 60 seconds) with detailed anatomy points (178,831 ± 70,897) collected and magnetic points throughout LA. At the end of the procedures in Group A, the LA model was confirmed to be stable and its location was within the distance threshold (1 mm). Procedure time (117.9 ± 29.6 minutes vs. 119.2 ± 29.7 minutes, P = 0.89), fluoroscopy time (6.1 ± 2.4 minutes vs. 4.8 ± 2.2 minutes, P = 0.07), and ablation time (28.0 ± 12.9 minutes vs. 27.9 ± 15.8 minutes, P = 0.98) were similar in Group A versus Group B, respectively. No complications occurred in either group.Conclusions: LA mapped by the novel system is stable and reliable. Combined with RMN, it could be effectively used for AF ablation without impacting overall procedural times.
- 17 August 2017
- Published by Wiley in Clinical Cardiology
- Vol. 40 (11) , 1083-1089
Prediction and prognosis of ventricular tachycardia recurrence after catheter ablation with remote magnetic navigation for electrical storm in patients with ischemic cardiomyopathy
Background: Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM).Hypothesis: We hypothesized that VT recurrence can be predicted and be related to the all‐cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM.Methods: A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation.Results: After a mean follow‐up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20‐32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12‐19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00‐1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P < 0.01).Conclusions: Inducibility of any VT at the end of procedure for VT storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all‐cause death.
- 17 August 2017
- Published by Wiley in Clinical Cardiology
- Vol. 40 (11) , 1083-1089
Prediction and prognosis of ventricular tachycardia recurrence after catheter ablation with remote magnetic navigation for electrical storm in patients with ischemic cardiomyopathy
Background: Ventricular tachycardia (VT) recurrence after catheter ablation for electrical storm is commonly seen in patients with ischemic cardiomyopathy (ICM).Hypothesis: We hypothesized that VT recurrence can be predicted and be related to the all‐cause death after VT storm ablation guided by remote magnetic navigation (RMN) in patients with ICM.Methods: A total of 54 ICM patients (87% male; mean age, 65 ± 7.1 years) presenting with VT storm undergoing acute ablation using RMN were enrolled. Acute complete ablation success was defined as noninducibility of any sustained monomorphic VT at the end of the procedure. Early VT recurrence was defined as the occurrence of sustained VT within 1 month after the first ablation.Results: After a mean follow‐up of 17.1 months, 27 patients (50%) had freedom from VT recurrence. Sustained VT recurred in 12 patients (22%) within 1 month following the first ablation. In univariate analysis, VT recurrence was associated with incomplete procedural success (hazard ratio [HR]: 6.25, 95% confidence interval [CI]: 1.20‐32.47, P = 0.029), lack of amiodarone usage before ablation (HR: 4.71, 95% CI: 1.12‐19.7, P = 0.034), and a longer procedural time (HR: 1.023, 95% CI: 1.00‐1.05, P = 0.05). The mortality of patients with early VT recurrence was higher than that of patients without recurrence (P < 0.01).Conclusions: Inducibility of any VT at the end of procedure for VT storm guided by RMN is the strongest predictor of VT recurrence. ICM patients who have early recurrences after VT storm ablation are at high risk of all‐cause death.
- 10 March 2016
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (S1) , S23-S28
Efficacy and Safety of Atrial Fibrillation Ablation Using Remote Magnetic Navigation: Experience from 1,006 Procedures
RMN‐Guided Ablation for AF: Background: The objective of this study was to assess the procedural outcomes of catheter ablation guided by remote magnetic navigation (RMN) in a large cohort of patients with paroxysmal atrial fibrillation (PAF) and persistent AF (PerAF).Methods: A total of 726 patients (547 male, age: 58.5 ± 10.3 years) with symptomatic AF (61% PAF) were analyzed from a prospective ablation registry. Procedural parameters including pulmonary venous (PV) anatomy, left atrial (LA) volume, procedural time, ablation time, fluoroscopy time, total X‐ray dose, and complications were assessed.Results: One thousand and six ablation procedures were analyzed. One‐third of the patients (240/726) were ablated on more than one occasion, resulting in a mean of 1.3 ± 0.6 times for the entire group. When analyzing all procedures, the mean procedural time and ablation time was 134 ± 35 minutes and 2,130 ± 1,025 seconds, respectively. The mean fluoroscopy time was 5.4 ± 3.7 minutes. Compared to PAF patients, procedural time and ablation time were significantly increased in patients with PerAF by 10% (P < 0.001) and 19% (P < 0.001), respectively. However, fluoroscopy time was not increased (5.3 ± 3.5 minutes, PAF vs. 5.6 ± 4.0 minutes, PerAF, P = 0.17). The overall complication rate was 0.6%. One PAF patient experienced cardiac tamponade. AF repeat ablations by RMN significantly reduced the procedural and ablation times when compared with their first ablation times.Conclusions: AF ablation guided by RMN is safe as evidenced by a low complication rate. Fluoroscopy time was relatively short for both PAF and PerAF ablation.
- 10 March 2016
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (S1) , S23-S28
Efficacy and Safety of Atrial Fibrillation Ablation Using Remote Magnetic Navigation: Experience from 1,006 Procedures
RMN‐Guided Ablation for AF: Background: The objective of this study was to assess the procedural outcomes of catheter ablation guided by remote magnetic navigation (RMN) in a large cohort of patients with paroxysmal atrial fibrillation (PAF) and persistent AF (PerAF).Methods: A total of 726 patients (547 male, age: 58.5 ± 10.3 years) with symptomatic AF (61% PAF) were analyzed from a prospective ablation registry. Procedural parameters including pulmonary venous (PV) anatomy, left atrial (LA) volume, procedural time, ablation time, fluoroscopy time, total X‐ray dose, and complications were assessed.Results: One thousand and six ablation procedures were analyzed. One‐third of the patients (240/726) were ablated on more than one occasion, resulting in a mean of 1.3 ± 0.6 times for the entire group. When analyzing all procedures, the mean procedural time and ablation time was 134 ± 35 minutes and 2,130 ± 1,025 seconds, respectively. The mean fluoroscopy time was 5.4 ± 3.7 minutes. Compared to PAF patients, procedural time and ablation time were significantly increased in patients with PerAF by 10% (P < 0.001) and 19% (P < 0.001), respectively. However, fluoroscopy time was not increased (5.3 ± 3.5 minutes, PAF vs. 5.6 ± 4.0 minutes, PerAF, P = 0.17). The overall complication rate was 0.6%. One PAF patient experienced cardiac tamponade. AF repeat ablations by RMN significantly reduced the procedural and ablation times when compared with their first ablation times.Conclusions: AF ablation guided by RMN is safe as evidenced by a low complication rate. Fluoroscopy time was relatively short for both PAF and PerAF ablation.