Gennaro Picardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gennaro Picardi has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
Razvigor Ossikovski
LPICM, CNRS, Ecole Polytechnique, Université Paris Saclay, 91128 Palaiseau, France
11 shared publicationsMarc Chaigneau
LPICM, Ecole Polytechnique, CNRS, 91128 Palaiseau, France
7 shared publicationsRolf Schuster
Institut für Physikalische Chemie, Universität Karlsruhe, Kaiserstr. 12, D-76131 Karlsruhe, Germany
6 shared publicationsGerhard Ertl
Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4–6, D-14195 Berlin, Germany
5 shared publications- Bruno Pettinger
Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, D-14195 Berlin, Germany
4 shared publications - Linwei Yu
Nanjing University
4 shared publications
Latest Publications
- Open Access
- 24 May 2024
- Published by Elsevier in Talanta Open
- Vol. 9
Rapid screening of designer fuel frauds by Raman spectroscopy
- 24 May 2024
- Published by Elsevier in Talanta Open
- Vol. 9
Open AccessRapid screening of designer fuel frauds by Raman spectroscopy
- 12 May 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 124 (22) , 11902-11912
Surface Modification of Au Nanoparticles with Heteroleptic Cu(I) Diimine Complexes
- 12 May 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 124 (22) , 11902-11912
Surface Modification of Au Nanoparticles with Heteroleptic Cu(I) Diimine Complexes
- 1 April 2020
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (5) , 3411-3419
Raman Fingerprints of Graphene Produced by Anodic Electrochemical Exfoliation
Electrochemical exfoliation is one of the most promising methods for scalable production of graphene. However, limited understanding of its Raman spectrum as well as lack of measurement standards for graphene strongly limit its industrial applications. In this work we show a systematic study of the Raman spectrum of electrochemically exfoliated graphene, produced using different electrolytes and different types of solvents in varying amounts. We demonstrate that no information on the thickness can be extracted from the shape of the 2D peak as this type of graphene is defective. Furthermore, the number of defects and the uniformity of the samples strongly depend on the experimental conditions, including post-processing. Under specific conditions, formation of short conductive trans-polyacetylene chains has been observed. Our Raman analysis provides guidance for the community on how to get information on defects coming from electrolyte, temperature and other experimental conditions, by making Raman spectroscopy a powerful metrology tool.
- 1 April 2020
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (5) , 3411-3419
Raman Fingerprints of Graphene Produced by Anodic Electrochemical Exfoliation
Electrochemical exfoliation is one of the most promising methods for scalable production of graphene. However, limited understanding of its Raman spectrum as well as lack of measurement standards for graphene strongly limit its industrial applications. In this work we show a systematic study of the Raman spectrum of electrochemically exfoliated graphene, produced using different electrolytes and different types of solvents in varying amounts. We demonstrate that no information on the thickness can be extracted from the shape of the 2D peak as this type of graphene is defective. Furthermore, the number of defects and the uniformity of the samples strongly depend on the experimental conditions, including post-processing. Under specific conditions, formation of short conductive trans-polyacetylene chains has been observed. Our Raman analysis provides guidance for the community on how to get information on defects coming from electrolyte, temperature and other experimental conditions, by making Raman spectroscopy a powerful metrology tool.
- Open Access
- 30 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 13110
Tissue degeneration in ALS affected spinal cord evaluated by Raman spectroscopy
The Raman spectral features from spinal cord tissue sections of transgenic, ALS model mice and non-transgenic mice were compared using 457 nm excitation line, profiting from the favourable signal intensity obtained in the molecular fingerprint region at this wavelength. Transverse sections from four SOD1G93A mice at 75 days and from two at 90 days after birth were analysed and compared with sections of similarly aged control mice. The spectra acquired within the grey matter of tissue sections from the diseased mice is markedly different from the grey matter signature of healthy mice. In particular, we observe an intensity increase in the spectral windows 450–650 cm−1 and 1050–1200 cm−1, accompanied by an intensity decrease in the lipid contributions at ~1660 cm−1, ~1440 cm−1 and ~1300 cm−1. Axons demyelination, loss of lipid structural order and the proliferation and aggregation of branched proteoglycans are related to the observed spectral modifications. Furthermore, the grey and white matter components of the spinal cord sections could also be spectrally distinguished, based on the relative intensity of characteristic lipid and protein bands. Raman spectra acquired from the white matter regions of the SOD1G93A mice closely resembles those from control mice.
- 30 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 13110
Open AccessTissue degeneration in ALS affected spinal cord evaluated by Raman spectroscopy
The Raman spectral features from spinal cord tissue sections of transgenic, ALS model mice and non-transgenic mice were compared using 457 nm excitation line, profiting from the favourable signal intensity obtained in the molecular fingerprint region at this wavelength. Transverse sections from four SOD1G93A mice at 75 days and from two at 90 days after birth were analysed and compared with sections of similarly aged control mice. The spectra acquired within the grey matter of tissue sections from the diseased mice is markedly different from the grey matter signature of healthy mice. In particular, we observe an intensity increase in the spectral windows 450–650 cm−1 and 1050–1200 cm−1, accompanied by an intensity decrease in the lipid contributions at ~1660 cm−1, ~1440 cm−1 and ~1300 cm−1. Axons demyelination, loss of lipid structural order and the proliferation and aggregation of branched proteoglycans are related to the observed spectral modifications. Furthermore, the grey and white matter components of the spinal cord sections could also be spectrally distinguished, based on the relative intensity of characteristic lipid and protein bands. Raman spectra acquired from the white matter regions of the SOD1G93A mice closely resembles those from control mice.
- Retracted
- 1 March 2018
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 513, 205-213
RETRACTED: Polyphosphonate ligands: From synthesis to design of hybrid PEGylated nanoparticles toward phototherapy studies
- 1 March 2018
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 513, 205-213
RetractedRETRACTED: Polyphosphonate ligands: From synthesis to design of hybrid PEGylated nanoparticles toward phototherapy studies
- 16 January 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 121 (4) , 2402-2409
Plasmonic Properties of Aluminum Nanocylinders in the Visible Range
- 16 January 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 121 (4) , 2402-2409
Plasmonic Properties of Aluminum Nanocylinders in the Visible Range
- 8 November 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 120 (45) , 26025-26033
Spectral Shift of the Plasmon Resonance Between the Optical Extinction and Absorption of Gold and Aluminum Nanodisks
- 8 November 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 120 (45) , 26025-26033
Spectral Shift of the Plasmon Resonance Between the Optical Extinction and Absorption of Gold and Aluminum Nanodisks
- 3 August 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 120 (32) , 18209-18219
Molecular Bending at the Nanoscale Evidenced by Tip-Enhanced Raman Spectroscopy in Tunneling Mode on Thiol Self-Assembled Monolayers
- 3 August 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 120 (32) , 18209-18219
Molecular Bending at the Nanoscale Evidenced by Tip-Enhanced Raman Spectroscopy in Tunneling Mode on Thiol Self-Assembled Monolayers
- 29 February 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 108 (9) , 091103
Tensile-strained germanium microdisks with circular Bragg reflectors
We demonstrate the combination of germanium microdisks tensily strained by silicon nitride layers and circular Bragg reflectors. The microdisks with suspended lateral Bragg reflectors form a cavity with quality factors up to 2000 around 2 μm. This represents a key feature to achieve a microlaser with a quasi-direct band gap germanium under a 1.6% biaxial tensile strain. We show that lowering the temperature significantly improves the quality factor of the quasi-radial modes. Linewidth narrowing is observed in a range of weak continuous wave excitation powers. We finally discuss the requirements to achieve lasing with these kind of structures.
- 29 February 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 108 (9) , 091103
Tensile-strained germanium microdisks with circular Bragg reflectors
We demonstrate the combination of germanium microdisks tensily strained by silicon nitride layers and circular Bragg reflectors. The microdisks with suspended lateral Bragg reflectors form a cavity with quality factors up to 2000 around 2 μm. This represents a key feature to achieve a microlaser with a quasi-direct band gap germanium under a 1.6% biaxial tensile strain. We show that lowering the temperature significantly improves the quality factor of the quasi-radial modes. Linewidth narrowing is observed in a range of weak continuous wave excitation powers. We finally discuss the requirements to achieve lasing with these kind of structures.