Arturo Nicola Natali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arturo Nicola Natali has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Emanuele Luigi Carniel
Department of Industrial Engineering University of Padova Padova Italy
55 shared publications - Chiara Giulia Fontanella
Centre for Mechanics of Biological Materials, University of Padova, 35131 Padova, Italy
31 shared publications - Silvia Todros
Department of Industrial Engineering, University of Padova
16 shared publications - Piero Giovanni Pavan
Department of Industrial Engineering, University of Padova, Padua, Italy
14 shared publications Piero G. Pavan
Department of Industrial Engineering, University of Padova, via Venezia 1, 35131, Padua, Italy
11 shared publicationsP.G. Pavan
8 shared publications
Latest Publications
- Open Access
- 13 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6004
Interaction Phenomena between Dental Implants and Bone Tissue in Case of Misfit: A Pilot Study
The biomechanical response of cortical and trabecular bone tissues represents a fundamental aspect for the interpretation of the functional response of dental implants. In the case of misfit, the interaction phenomena occurring within the surgical and the subsequent healing phases must be interpreted primarily in the light of the response of bone tissue. This is influenced by the specific loadings induced, characterized by intensity and variable trends. The pilot study reported, which intentionally refers to a simple case of a two-implants frame, is addressed to define the method to approach the biomechanical investigation of the problem and to attest the necessity to integrate clinical competences with biomechanical analysis for interpreting different aspects of osseointegration. The action induced in cortical and trabecular bone regions depending on the implant frame conformation, the surgical procedure adopted, the varying condition at the bone–implant interface and the evolutionary trend of healing are the principal aspects to be considered to evaluate the osseointegration process. The biomechanical reliability of the specific implant frame is investigated in terms of bone–implant interaction by means of numerical models. This approach can offer valid information and support clinical practice under the fundamental condition that bone biomechanical behavior is properly characterized and represented in the model, in spite of the complex formulation to be adopted.
- 13 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6004
Open AccessInteraction Phenomena between Dental Implants and Bone Tissue in Case of Misfit: A Pilot Study
The biomechanical response of cortical and trabecular bone tissues represents a fundamental aspect for the interpretation of the functional response of dental implants. In the case of misfit, the interaction phenomena occurring within the surgical and the subsequent healing phases must be interpreted primarily in the light of the response of bone tissue. This is influenced by the specific loadings induced, characterized by intensity and variable trends. The pilot study reported, which intentionally refers to a simple case of a two-implants frame, is addressed to define the method to approach the biomechanical investigation of the problem and to attest the necessity to integrate clinical competences with biomechanical analysis for interpreting different aspects of osseointegration. The action induced in cortical and trabecular bone regions depending on the implant frame conformation, the surgical procedure adopted, the varying condition at the bone–implant interface and the evolutionary trend of healing are the principal aspects to be considered to evaluate the osseointegration process. The biomechanical reliability of the specific implant frame is investigated in terms of bone–implant interaction by means of numerical models. This approach can offer valid information and support clinical practice under the fundamental condition that bone biomechanical behavior is properly characterized and represented in the model, in spite of the complex formulation to be adopted.
- 16 January 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (3) , e3308
Biomechanical analysis of the interaction phenomena between artificial urinary sphincter and urethral duct
Male urinary incontinence is a widespread healthcare problem, leading to a miserable quality of life. Artificial urinary sphincter (AUS) is a device inserted mostly around the urethra in adult males, which mimics the urinary sphincter by providing a closure during urinary storage and a subsequent open to permit voiding. The interaction phenomena occurring between AUS cuff and urethral duct represent a fundamental problem in the investigation of AUS reliability and durability. In this work, computational methods are exploited to deeply investigate the mechanics of interaction phenomena occurring between urethral duct and AUS device. Experimental studies are performed on urethral tissues, and structural tests are carried out on the overall urethral duct to obtain a large set of information required for mechanical properties definition. The mechanical behavior of AUS cuff is investigated using mechanical and physicochemical procedures. The cuff conformation is acquired by computed tomography techniques for the definition of the numerical model. Numerical analyses are developed to evaluate the mechanical response of urethral duct in interaction with AUS cuff, considering the lumen occlusion process for maintaining urinary continence. Finally, the investigation of the compressive stress and strain fields within urethral tissues allows the identification of device performance and reliability in correlation with surgical practice.
- 16 January 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (3) , e3308
Biomechanical analysis of the interaction phenomena between artificial urinary sphincter and urethral duct
Male urinary incontinence is a widespread healthcare problem, leading to a miserable quality of life. Artificial urinary sphincter (AUS) is a device inserted mostly around the urethra in adult males, which mimics the urinary sphincter by providing a closure during urinary storage and a subsequent open to permit voiding. The interaction phenomena occurring between AUS cuff and urethral duct represent a fundamental problem in the investigation of AUS reliability and durability. In this work, computational methods are exploited to deeply investigate the mechanics of interaction phenomena occurring between urethral duct and AUS device. Experimental studies are performed on urethral tissues, and structural tests are carried out on the overall urethral duct to obtain a large set of information required for mechanical properties definition. The mechanical behavior of AUS cuff is investigated using mechanical and physicochemical procedures. The cuff conformation is acquired by computed tomography techniques for the definition of the numerical model. Numerical analyses are developed to evaluate the mechanical response of urethral duct in interaction with AUS cuff, considering the lumen occlusion process for maintaining urinary continence. Finally, the investigation of the compressive stress and strain fields within urethral tissues allows the identification of device performance and reliability in correlation with surgical practice.
- Open Access
- 14 November 2018
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 39 (5) , 764-772
Marker Tracking for Local Strain Measurement in Mechanical Testing of Biomedical Materials
- 14 November 2018
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 39 (5) , 764-772
Open AccessMarker Tracking for Local Strain Measurement in Mechanical Testing of Biomedical Materials
- 1 December 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 65, 75-81
Urethral lumen occlusion by artificial sphincteric device: Evaluation of degraded tissues effects
- 1 December 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 65, 75-81
Urethral lumen occlusion by artificial sphincteric device: Evaluation of degraded tissues effects
- 5 June 2017
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 16 (6) , 1833-1843
From single muscle fiber to whole muscle mechanics: a finite element model of a muscle bundle with fast and slow fibers
Muscles exhibit highly complex, multi-scale architecture with thousands of muscle fibers, each with different properties, interacting with each other and surrounding connective structures. Consequently, the results of single-fiber experiments are scarcely linked to the macroscopic or whole muscle behavior. This is especially true for human muscles where it would be important to understand of how skeletal muscles disorders affect patients’ life. In this work, we developed a mathematical model to study how fast and slow muscle fibers, well characterized in single-fiber experiments, work and generate together force and displacement in muscle bundles. We characterized the parameters of a Hill-type model, using experimental data on fast and slow single human muscle fibers, and comparing experimental data with numerical simulations obtained from finite element (FE) models of single fibers. Then, we developed a FE model of a bundle of 19 fibers, based on an immunohistochemically stained cross section of human diaphragm and including the corresponding properties of each slow or fast fiber. Simulations of isotonic contractions of the bundle model allowed the generation of its apparent force–velocity relationship. Although close to the average of the force–velocity curves of fast and slow fibers, the bundle curve deviates substantially toward the fast fibers at low loads. We believe that the present model and the characterization of the force–velocity curve of a fiber bundle represents the starting point to link the single-fiber properties to those of whole muscle with FE application in phenomenological models of human muscles.
- 5 June 2017
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 16 (6) , 1833-1843
From single muscle fiber to whole muscle mechanics: a finite element model of a muscle bundle with fast and slow fibers
Muscles exhibit highly complex, multi-scale architecture with thousands of muscle fibers, each with different properties, interacting with each other and surrounding connective structures. Consequently, the results of single-fiber experiments are scarcely linked to the macroscopic or whole muscle behavior. This is especially true for human muscles where it would be important to understand of how skeletal muscles disorders affect patients’ life. In this work, we developed a mathematical model to study how fast and slow muscle fibers, well characterized in single-fiber experiments, work and generate together force and displacement in muscle bundles. We characterized the parameters of a Hill-type model, using experimental data on fast and slow single human muscle fibers, and comparing experimental data with numerical simulations obtained from finite element (FE) models of single fibers. Then, we developed a FE model of a bundle of 19 fibers, based on an immunohistochemically stained cross section of human diaphragm and including the corresponding properties of each slow or fast fiber. Simulations of isotonic contractions of the bundle model allowed the generation of its apparent force–velocity relationship. Although close to the average of the force–velocity curves of fast and slow fibers, the bundle curve deviates substantially toward the fast fibers at low loads. We believe that the present model and the characterization of the force–velocity curve of a fiber bundle represents the starting point to link the single-fiber properties to those of whole muscle with FE application in phenomenological models of human muscles.
- 25 March 2017
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 16 (4) , 1439-1446
Urethral lumen occlusion by artificial sphincteric devices: a computational biomechanics approach
The action induced by artificial sphincteric devices to provide urinary continence is related to the problem of evaluating the interaction between the occlusive cuff and the urethral duct. The intensity and distribution of the force induced within the region of application determine a different occlusion process and potential degradation of the urethral tissue, mostly at the borders of the cuff. This problem is generally considered in the light of clinical and surgical operational experience, while a valid cooperation is established with biomechanical competences by means of experimental and numerical investigation. A three-dimensional model of the urethra is proposed aiming at a representation of the phases of the urethral occlusion through artificial sphincters. Different conformations of the cuff are considered, mimicking different loading conditions in terms of force intensity and distribution and consequent deformation caused in soft tissues. The action induced in the healthy urethra is investigated, as basis for an evaluation of the efficacy and reliability of the sphincteric devices. The problem is characterized by coupled nonlinear geometric and material problem and entails a complex constitutive formulation. A heavy computational procedure is developed by means of analyses that operate within an explicit finite element formulation. Results reported outline the overall response of the urethral duct during lumen occlusion, leading to an accurate description of the phenomenon in the different phases.
- 25 March 2017
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 16 (4) , 1439-1446
Urethral lumen occlusion by artificial sphincteric devices: a computational biomechanics approach
The action induced by artificial sphincteric devices to provide urinary continence is related to the problem of evaluating the interaction between the occlusive cuff and the urethral duct. The intensity and distribution of the force induced within the region of application determine a different occlusion process and potential degradation of the urethral tissue, mostly at the borders of the cuff. This problem is generally considered in the light of clinical and surgical operational experience, while a valid cooperation is established with biomechanical competences by means of experimental and numerical investigation. A three-dimensional model of the urethra is proposed aiming at a representation of the phases of the urethral occlusion through artificial sphincters. Different conformations of the cuff are considered, mimicking different loading conditions in terms of force intensity and distribution and consequent deformation caused in soft tissues. The action induced in the healthy urethra is investigated, as basis for an evaluation of the efficacy and reliability of the sphincteric devices. The problem is characterized by coupled nonlinear geometric and material problem and entails a complex constitutive formulation. A heavy computational procedure is developed by means of analyses that operate within an explicit finite element formulation. Results reported outline the overall response of the urethral duct during lumen occlusion, leading to an accurate description of the phenomenon in the different phases.
- 1 March 2017
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 89, 142-150
The study of equivalent material parameters in a hyperelastic model
- 1 March 2017
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 89, 142-150
The study of equivalent material parameters in a hyperelastic model
- 1 March 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 67, 1-9
Investigation of biomechanical response of Hoffa's fat pad and comparative characterization
- 1 March 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 67, 1-9
Investigation of biomechanical response of Hoffa's fat pad and comparative characterization
- 20 February 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40 (2) , 289-295
Numerical model for healthy and injured ankle ligaments
The aim of this work is to provide a computational tool for the investigation of ankle mechanics under different loading conditions. The attention is focused on the biomechanical role of ankle ligaments that are fundamental for joints stability. A finite element model of the human foot is developed starting from Computed Tomography and Magnetic Resonance Imaging, using particular attention to the definition of ankle ligaments. A refined fiber-reinforced visco-hyperelastic constitutive model is assumed to characterize the mechanical response of ligaments. Numerical analyses that interpret anterior drawer and the talar tilt tests reported in literature are performed. The numerical results are in agreement with the range of values obtained by experimental tests confirming the accuracy of the procedure adopted. The increase of the ankle range of motion after some ligaments rupture is also evaluated, leading to the capability of the numerical models to interpret the damage conditions. The developed computational model provides a tool for the investigation of foot and ankle functionality in terms of stress–strain of the tissues and in terms of ankle motion, considering different types of damage to ankle ligaments.
- 20 February 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40 (2) , 289-295
Numerical model for healthy and injured ankle ligaments
The aim of this work is to provide a computational tool for the investigation of ankle mechanics under different loading conditions. The attention is focused on the biomechanical role of ankle ligaments that are fundamental for joints stability. A finite element model of the human foot is developed starting from Computed Tomography and Magnetic Resonance Imaging, using particular attention to the definition of ankle ligaments. A refined fiber-reinforced visco-hyperelastic constitutive model is assumed to characterize the mechanical response of ligaments. Numerical analyses that interpret anterior drawer and the talar tilt tests reported in literature are performed. The numerical results are in agreement with the range of values obtained by experimental tests confirming the accuracy of the procedure adopted. The increase of the ankle range of motion after some ligaments rupture is also evaluated, leading to the capability of the numerical models to interpret the damage conditions. The developed computational model provides a tool for the investigation of foot and ankle functionality in terms of stress–strain of the tissues and in terms of ankle motion, considering different types of damage to ankle ligaments.
- 10 February 2017
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (9) , 1683-1691
Investigation of interaction phenomena between crural fascia and muscles by using a three-dimensional numerical model
- 10 February 2017
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (9) , 1683-1691
Investigation of interaction phenomena between crural fascia and muscles by using a three-dimensional numerical model