Limei Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Limei Chen has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Xuzhong Xu
Department of Anesthesiology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, China
7 shared publications - Hongfei Chen
Department of Pain Medicine, The First Affiliated Hospital, Wenzhou Medical University, Zhejiang, China
2 shared publications Le Liu
2 shared publications- Quanguang Wang
Department of Anesthesiology, the First Affiliated Hospital of Wenzhou Medical University, Zhejiang, China
2 shared publications - Thomas John Papadimos
Anesthesiology, Surgery, and Critical Care, The University of Toledo College of Medicine and Life Sciences, Toledo, USA
2 shared publications Xian-Yang Guo
2 shared publications
Latest Publications
- 20 April 2022
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (1) , 55-62
The utility of a multi-orifice epidural catheter when using the “Spray-as-You-Go” technique for topical Airway Anesthesia during Flexible Bronchoscopy, a randomised trial
Background Lidocaine administered through the working channel of a flexible bronchoscope can provide effective local anesthesia but cannot achieve good distribution in the airway. This study was undertaken to determine whether lidocaine delivered via a multi-orifice epidural catheter (three orifices/openings) is superior to conventional method and if a better distribution and decreased the cough reflex can be achieved. Methods The patients (N = 100; 50 in each group) were randomized to receive either topical airway anesthesia by the “spray-as-you-go” technique via conventional application (group C) through the working channel of the bronchoscope or via a triple-orifice epidural catheter (group E). The primary outcome measurement was the cough severity, which was documented using a 4-point scale. Bronchoscopists and nurses assessed the coughing. The visual analogue scale (VAS) score for cough, total consumption of propofol and lidocaine, requirement frequency of propofol and topical anesthesia, PACU retention time, and adverse events were also compared. Results There was a significant difference in the median cough severity scores between the two groups (group C: 3 vs. group E: 2, P = 0.004). The median visual analogue scale (VAS) scores for the cough, were significantly higher in group C than those in group E (bronchoscopist: 3 vs. 2 P = 0.002; nurse: 3 vs. 2, P < 0.001). The incidence of cough was significantly higher in group C in the trachea, left and right bronchi. The highest respiratory rate was higher in group C than in group E (P < 0.01). Eight patients in group C and two patients in group E had an oxygen saturation below 90% during flexible bronchoscopy(FB) (P = 0.046). More patients in group C required extra topical anesthesia than in group E (P < 0.001). The total lidocaine consumption was also higher in group C than that in group E (P < 0.001). Conclusions Endotracheal topical anesthesia via the multi-orifice epidural catheter (three holes/openings) during flexible bronchoscopy using the “spray-as-you-go” technique was appeared to be superior to the conventional method.
- 20 April 2022
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (1) , 55-62
The utility of a multi-orifice epidural catheter when using the “Spray-as-You-Go” technique for topical Airway Anesthesia during Flexible Bronchoscopy, a randomised trial
Background Lidocaine administered through the working channel of a flexible bronchoscope can provide effective local anesthesia but cannot achieve good distribution in the airway. This study was undertaken to determine whether lidocaine delivered via a multi-orifice epidural catheter (three orifices/openings) is superior to conventional method and if a better distribution and decreased the cough reflex can be achieved. Methods The patients (N = 100; 50 in each group) were randomized to receive either topical airway anesthesia by the “spray-as-you-go” technique via conventional application (group C) through the working channel of the bronchoscope or via a triple-orifice epidural catheter (group E). The primary outcome measurement was the cough severity, which was documented using a 4-point scale. Bronchoscopists and nurses assessed the coughing. The visual analogue scale (VAS) score for cough, total consumption of propofol and lidocaine, requirement frequency of propofol and topical anesthesia, PACU retention time, and adverse events were also compared. Results There was a significant difference in the median cough severity scores between the two groups (group C: 3 vs. group E: 2, P = 0.004). The median visual analogue scale (VAS) scores for the cough, were significantly higher in group C than those in group E (bronchoscopist: 3 vs. 2 P = 0.002; nurse: 3 vs. 2, P < 0.001). The incidence of cough was significantly higher in group C in the trachea, left and right bronchi. The highest respiratory rate was higher in group C than in group E (P < 0.01). Eight patients in group C and two patients in group E had an oxygen saturation below 90% during flexible bronchoscopy(FB) (P = 0.046). More patients in group C required extra topical anesthesia than in group E (P < 0.001). The total lidocaine consumption was also higher in group C than that in group E (P < 0.001). Conclusions Endotracheal topical anesthesia via the multi-orifice epidural catheter (three holes/openings) during flexible bronchoscopy using the “spray-as-you-go” technique was appeared to be superior to the conventional method.
- 4 January 2021
- Published by American Chemical Society (ACS) in Chemical Research in Toxicology
- Vol. 34 (1) , 103-109
Evaluation of Recombinant CYP3A4 Variants on the Metabolism of Oxycodone In Vitro
Cytochrome P450 3A4 is a highly polymorphic enzyme and metabolizes approximately 40%–60% of therapeutic drugs. Its genetic polymorphism may significantly affect the expression and function of CYP3A4 resulting in alterations of the pharmacokinetics and pharmacodynamics of the CYP3A4-mediated drugs. The purpose of this study was to evaluate the catalytic activities of 30 CYP3A4 nonsynonymous variants and wild type toward oxycodone in vitro. CYP3A4 proteins were incubated with oxycodone for 30 min at 37 °C and the reaction was terminated by cooling to −80 °C immediately. Ultraperformance liquid chromatography tandem mass-spectrometry was used to analyze noroxycodone, and kinetic parameters Km, Vmax, and intrinsic clearance (Vmax/Km) of noroxycodone were also determined. Compared with CYP3A4.1, 24 CYP3A4 variants (CYP3A4.2–.5, -.7–.16, -.18 and -.19, -.23 and -.24, -.28 and -.29, and -.31–.34) exhibited significantly decreased relative clearance values (from 4.82% ± 0.31% to 80.98% ± 5.08%), whereas CYP3A4.6, -.17, -.20, -.21, -.26, and -.30 displayed no detectable enzyme activity. As the first study of these alleles for oxycodone metabolism in vitro, results of this study may provide insight into establishing the genotype-phenotype relationship for oxycodone and serve as a reference for clinical administrators and advance the provision of personalized precision medicine.
- 4 January 2021
- Published by American Chemical Society (ACS) in Chemical Research in Toxicology
- Vol. 34 (1) , 103-109
Evaluation of Recombinant CYP3A4 Variants on the Metabolism of Oxycodone In Vitro
Cytochrome P450 3A4 is a highly polymorphic enzyme and metabolizes approximately 40%–60% of therapeutic drugs. Its genetic polymorphism may significantly affect the expression and function of CYP3A4 resulting in alterations of the pharmacokinetics and pharmacodynamics of the CYP3A4-mediated drugs. The purpose of this study was to evaluate the catalytic activities of 30 CYP3A4 nonsynonymous variants and wild type toward oxycodone in vitro. CYP3A4 proteins were incubated with oxycodone for 30 min at 37 °C and the reaction was terminated by cooling to −80 °C immediately. Ultraperformance liquid chromatography tandem mass-spectrometry was used to analyze noroxycodone, and kinetic parameters Km, Vmax, and intrinsic clearance (Vmax/Km) of noroxycodone were also determined. Compared with CYP3A4.1, 24 CYP3A4 variants (CYP3A4.2–.5, -.7–.16, -.18 and -.19, -.23 and -.24, -.28 and -.29, and -.31–.34) exhibited significantly decreased relative clearance values (from 4.82% ± 0.31% to 80.98% ± 5.08%), whereas CYP3A4.6, -.17, -.20, -.21, -.26, and -.30 displayed no detectable enzyme activity. As the first study of these alleles for oxycodone metabolism in vitro, results of this study may provide insight into establishing the genotype-phenotype relationship for oxycodone and serve as a reference for clinical administrators and advance the provision of personalized precision medicine.
- Open Access
- 16 July 2020
- Published by Springer Nature in Research Square
The Utility of a Multi-orifice Epidural Catheter when Using the “Spray-as-You-Go” Technique for Topical Airway Anesthesia during Flexible Bronchoscop, a randomised trial
BackgroundLidocaine administered through the working channel of a flexible bronchoscope can provide effective local anesthesia but cannot achieve good distribution in the airway. This study was undertaken to determine whether lidocaine delivered via a multi-orifice epidural catheter (three orifices/openings) is superior to conventional method and if a better distribution and decreased the cough reflex can be achieved.MethodsThe patients (N=100; 50 in each group) were randomized to receive either topical airway anesthesia by the “spray-as-you-go” technique via conventional application (group C) through the working channel of the bronchoscope or via a triple-orifice epidural catheter (group E). The primary outcome measurement was the cough severity, which was documented using a 4-point scale. Bronchoscopists and nurses assessed the coughing.ResultsThere was a significant difference in the median cough severity scores between the two groups (group C: 3 vs group E: 2, P =0.004). The median visual analogue scale (VAS) scores for the cough, were significantly higher in group C than those in group E (bronchoscopist: 3 vs 2 P =0.002; nurse: 3 vs 2, P <0.001). The incidence of cough was significantly higher in group C in the trachea, left and right bronchi. The highest respiratory rate was higher in group C than in group E ( P <0.01). Eight patients in group C and two patients in group E had an oxygen saturation below 90% during flexible bronchoscopy(FB) ( P =0.046). More patients in group C required extra topical anesthesia than in group E ( P <0.001). The total lidocaine consumption was also higher in group C than that in group E ( P <0.001).ConclusionsEndotracheal topical anesthesia via the multi-orifice epidural catheter (three holes/openings) during flexible bronchoscopy using the “spray-as-you-go” technique was appeared to be superior to the conventional method.Trial registrationChinese Clinical Trial Register(Registration number #ChiCTR1800014690;Date of Registration on January 29th,2018)http://www.chictr.org.cn/showproj.aspx?proj=24835
- 16 July 2020
- Published by Springer Nature in Research Square
Open AccessThe Utility of a Multi-orifice Epidural Catheter when Using the “Spray-as-You-Go” Technique for Topical Airway Anesthesia during Flexible Bronchoscop, a randomised trial
BackgroundLidocaine administered through the working channel of a flexible bronchoscope can provide effective local anesthesia but cannot achieve good distribution in the airway. This study was undertaken to determine whether lidocaine delivered via a multi-orifice epidural catheter (three orifices/openings) is superior to conventional method and if a better distribution and decreased the cough reflex can be achieved.MethodsThe patients (N=100; 50 in each group) were randomized to receive either topical airway anesthesia by the “spray-as-you-go” technique via conventional application (group C) through the working channel of the bronchoscope or via a triple-orifice epidural catheter (group E). The primary outcome measurement was the cough severity, which was documented using a 4-point scale. Bronchoscopists and nurses assessed the coughing.ResultsThere was a significant difference in the median cough severity scores between the two groups (group C: 3 vs group E: 2, P =0.004). The median visual analogue scale (VAS) scores for the cough, were significantly higher in group C than those in group E (bronchoscopist: 3 vs 2 P =0.002; nurse: 3 vs 2, P <0.001). The incidence of cough was significantly higher in group C in the trachea, left and right bronchi. The highest respiratory rate was higher in group C than in group E ( P <0.01). Eight patients in group C and two patients in group E had an oxygen saturation below 90% during flexible bronchoscopy(FB) ( P =0.046). More patients in group C required extra topical anesthesia than in group E ( P <0.001). The total lidocaine consumption was also higher in group C than that in group E ( P <0.001).ConclusionsEndotracheal topical anesthesia via the multi-orifice epidural catheter (three holes/openings) during flexible bronchoscopy using the “spray-as-you-go” technique was appeared to be superior to the conventional method.Trial registrationChinese Clinical Trial Register(Registration number #ChiCTR1800014690;Date of Registration on January 29th,2018)http://www.chictr.org.cn/showproj.aspx?proj=24835
- Open Access
- 22 April 2020
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2020, 1-7
Tissue Distribution of Hirsutine and Hirsuteine in Mice by Ultrahigh-Performance Liquid Chromatography-Mass Spectrometry
Hirsutine and hirsuteine were two alkaloid monomers extracted from the traditional Chinese medicine Uncaria rhynchophylla, which have pharmacological effects such as antihypertension, anti-infection, and heart protection. An ultrahigh-performance liquid chromatography-mass spectrometry was established for the determination of hirsutine and hirsuteine in tissues (liver, kidney, heart, spleen, brain, and lung), and their absorption, distribution, and metabolism were studied for providing information on its pharmacological mechanism. UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) was used for chromatographic separation. The mobile phase was acetonitrile-0.1% formic acid, with a gradient elution, and the total run time was 4 min. Electrospray was used in the positive ion mode, and the multiple reaction monitoring (MRM) mode was for quantification. The acetonitrile precipitation method was used to remove protein-treated mouse plasma and tissue homogenate samples. In the concentration range of 2–5000 ng/g, hirsutine and hirsuteine in tissues showed good linearity (r > 0.995), and the lower limit of quantification was 2 ng/g. In the plasma and liver tissues, the interday and intraday precision of hirsutine and hirsuteine was less than 15%, the accuracy was between 90.9% and 110.1%, and the average recovery was better than 73.0%. The matrix effect was between 86.2% and 104.7%. The results showed that the precision, accuracy, recovery, and matrix effects meet the requirements for the study on the distribution of hirsutine and hirsuteine. After intraperitoneal administration of 10 mg/kg hirsutine and hirsuteine in mice, the distribution levels were highest in liver and kidney tissues, followed by the spleen and lung. Hirsutine and hirsuteine were low in brain tissue, but had obvious distribution, suggesting that they may pass through the blood-brain barrier.
- 22 April 2020
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2020, 1-7
Open AccessTissue Distribution of Hirsutine and Hirsuteine in Mice by Ultrahigh-Performance Liquid Chromatography-Mass Spectrometry
Hirsutine and hirsuteine were two alkaloid monomers extracted from the traditional Chinese medicine Uncaria rhynchophylla, which have pharmacological effects such as antihypertension, anti-infection, and heart protection. An ultrahigh-performance liquid chromatography-mass spectrometry was established for the determination of hirsutine and hirsuteine in tissues (liver, kidney, heart, spleen, brain, and lung), and their absorption, distribution, and metabolism were studied for providing information on its pharmacological mechanism. UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) was used for chromatographic separation. The mobile phase was acetonitrile-0.1% formic acid, with a gradient elution, and the total run time was 4 min. Electrospray was used in the positive ion mode, and the multiple reaction monitoring (MRM) mode was for quantification. The acetonitrile precipitation method was used to remove protein-treated mouse plasma and tissue homogenate samples. In the concentration range of 2–5000 ng/g, hirsutine and hirsuteine in tissues showed good linearity (r > 0.995), and the lower limit of quantification was 2 ng/g. In the plasma and liver tissues, the interday and intraday precision of hirsutine and hirsuteine was less than 15%, the accuracy was between 90.9% and 110.1%, and the average recovery was better than 73.0%. The matrix effect was between 86.2% and 104.7%. The results showed that the precision, accuracy, recovery, and matrix effects meet the requirements for the study on the distribution of hirsutine and hirsuteine. After intraperitoneal administration of 10 mg/kg hirsutine and hirsuteine in mice, the distribution levels were highest in liver and kidney tissues, followed by the spleen and lung. Hirsutine and hirsuteine were low in brain tissue, but had obvious distribution, suggesting that they may pass through the blood-brain barrier.
- Open Access
- 20 November 2018
- Published by Springer Nature in BMC Anesthesiology
- Vol. 18 (1) , 174
Levosimendan is superior to epinephrine on coronary flow for lipid-base resuscitation of bupivacaine-induced asystole in the isolated rat heart
Successful resuscitation from asystole induced by bupivacaine requires the reestablishment of a sufficient coronary flow (CF) quickly. This study was designed to test whether levosimendan was superior to epinephrine in the reestablishment of crucial coronary flows after bupivacaine-induced asystole. The isolated, perfused, nonrecirculating, Langendorff rat heart preparation was used. Bupivacaine 100 μmol/L was perfused into rat hearts to induce asystole, and then for 3 min thereafter. Three experimental groups were assessed after asystole with infusions as follow: (1) a mixture of 2% lipid emulsion and 40 μmol/L bupivacaine (control group), (2) a mixture of 0.15 μg/mL epinephrine combined with 2% lipid emulsion and 40 μmol/L bupivacaine (epinephrine group), and (3) a mixture of 5 μmol/L levosimendan combined with a 2% lipid emulsion and 40 μmol/L bupivacaine mixture (levosimendan group). Coronary flow (CF), the time to recovery (Trecovery), the number of ventricular arrhythmias, and cardiac function parameters were recorded for 40 min after heartbeat recovery. All hearts in the control, epinephrine and levosimendan groups had heartbeat recovery. The rank order of the mean CF from highest to lowest was the levosimendan group > the epinepgrine group > the control group (P < 0.05). The rank order of Trecovery from shortest to longest was the levosimendan group < the epinephrine group < the control group (P < 0.01). During the recovery phase, isolated rat hearts developed more ventricular arrhythmias in the epinephrine group than in the levosimendan group (P = 0.01). Levosimendan is superior to epinephrine in producing higher CFs and faster recovery when reversing bupivacaine-induced asystole in the isolated rat hearts.
- 20 November 2018
- Published by Springer Nature in BMC Anesthesiology
- Vol. 18 (1) , 174
Open AccessLevosimendan is superior to epinephrine on coronary flow for lipid-base resuscitation of bupivacaine-induced asystole in the isolated rat heart
Successful resuscitation from asystole induced by bupivacaine requires the reestablishment of a sufficient coronary flow (CF) quickly. This study was designed to test whether levosimendan was superior to epinephrine in the reestablishment of crucial coronary flows after bupivacaine-induced asystole. The isolated, perfused, nonrecirculating, Langendorff rat heart preparation was used. Bupivacaine 100 μmol/L was perfused into rat hearts to induce asystole, and then for 3 min thereafter. Three experimental groups were assessed after asystole with infusions as follow: (1) a mixture of 2% lipid emulsion and 40 μmol/L bupivacaine (control group), (2) a mixture of 0.15 μg/mL epinephrine combined with 2% lipid emulsion and 40 μmol/L bupivacaine (epinephrine group), and (3) a mixture of 5 μmol/L levosimendan combined with a 2% lipid emulsion and 40 μmol/L bupivacaine mixture (levosimendan group). Coronary flow (CF), the time to recovery (Trecovery), the number of ventricular arrhythmias, and cardiac function parameters were recorded for 40 min after heartbeat recovery. All hearts in the control, epinephrine and levosimendan groups had heartbeat recovery. The rank order of the mean CF from highest to lowest was the levosimendan group > the epinepgrine group > the control group (P < 0.05). The rank order of Trecovery from shortest to longest was the levosimendan group < the epinephrine group < the control group (P < 0.01). During the recovery phase, isolated rat hearts developed more ventricular arrhythmias in the epinephrine group than in the levosimendan group (P = 0.01). Levosimendan is superior to epinephrine in producing higher CFs and faster recovery when reversing bupivacaine-induced asystole in the isolated rat hearts.
- Open Access
- 15 September 2017
- Published by Springer Nature in BMC Anesthesiology
- Vol. 17 (1) , 128
Levosimendan combined with epinephrine improves rescue outcomes in a rat model of lipid-based resuscitation from bupivacaine-induced cardiac arrest
The effectiveness of a combination of a lipid emulsion with epinephrine in reversing local anesthetic-induced cardiac arrest has been confirmed. The combination of a lipid emulsion with levosimendan, was shown to be superior to administration of a lipid emulsion alone with regard to successful resuscitation. In this study, we compared the reversal effects of levosimendan, epinephrine, and a combination of the two agents in lipid-based resuscitation in a rat model of bupivacaine-induced cardiac arrest. Fifty-four adult male Sprague-Dawley rats were subjected to bupivacaine (15 mg·kg−1) –induced asystole and were then randomly divided into 3 groups. A lipid emulsion was used as the basic treatment, and administration of drug combinations varied in each group as follows: (1) levosimendan combined with epinephrine (LiEL); (2) epinephrine (LiE); and (3) levosimendan (LiL). The resuscitation outcomes were recorded and included the rate of return of spontaneous circulation (ROSC) and survival at 40 min, time to first heartbeat, time to ROSC, and cumulative dose of epinephrine. We calculated the wet-to-dry ratio of the lung, blood gas values at 40 min and bupivacaine concentration of cardiac tissue and plasma. The rates of ROSC in LiEL and LiE groups were higher than LiL group (P < 0.001; LiEL vs LiL, P = 0.001; LiE vs LiL, P = 0.007). The survival rate in LiEL group was higher than LiE group (P = 0.003; LiEL vs LiE, P = 0.008; LiEL vs LiL, P = 0.001). The time to first heart beat in LiEL group was shorter than LiE, LiL groups. (P < 0.001; LiE vs LiEL, P = 0.001; LiL vs LiEL, P < 0.001). The time to ROSC in LiEL group was shorter than LiE, LiL groups (P < 0.001; LiEL vs LiE, P < 0.001; LiEL vs LiL, P < 0.001). The result was similar for the bupivacaine concentration of cardiac tissue and plasma (cardiac tissue: P = 0.002; plasma: P = 0.011). Furthermore, there were significant differences in the blood-gas values at 40 min, wet-to-dry lung weight ratio, and ratio of damaged alveoli among groups. The LiEL group had the best result for all parameters (P < 0.01, P = 0.008, P < 0.001, respectively). Additionally, significantly less epinephrine was used in the LiEL group (P < 0.001). Levosimendan combined with epinephrine may be superior to either drug alone for lipid-based resuscitation in a rat model of bupivacaine-induced cardiac arrest. The drug combination was associated with a higher survival rate as well as decreased epinephrine consumption and lung damage.
- 15 September 2017
- Published by Springer Nature in BMC Anesthesiology
- Vol. 17 (1) , 128
Open AccessLevosimendan combined with epinephrine improves rescue outcomes in a rat model of lipid-based resuscitation from bupivacaine-induced cardiac arrest
The effectiveness of a combination of a lipid emulsion with epinephrine in reversing local anesthetic-induced cardiac arrest has been confirmed. The combination of a lipid emulsion with levosimendan, was shown to be superior to administration of a lipid emulsion alone with regard to successful resuscitation. In this study, we compared the reversal effects of levosimendan, epinephrine, and a combination of the two agents in lipid-based resuscitation in a rat model of bupivacaine-induced cardiac arrest. Fifty-four adult male Sprague-Dawley rats were subjected to bupivacaine (15 mg·kg−1) –induced asystole and were then randomly divided into 3 groups. A lipid emulsion was used as the basic treatment, and administration of drug combinations varied in each group as follows: (1) levosimendan combined with epinephrine (LiEL); (2) epinephrine (LiE); and (3) levosimendan (LiL). The resuscitation outcomes were recorded and included the rate of return of spontaneous circulation (ROSC) and survival at 40 min, time to first heartbeat, time to ROSC, and cumulative dose of epinephrine. We calculated the wet-to-dry ratio of the lung, blood gas values at 40 min and bupivacaine concentration of cardiac tissue and plasma. The rates of ROSC in LiEL and LiE groups were higher than LiL group (P < 0.001; LiEL vs LiL, P = 0.001; LiE vs LiL, P = 0.007). The survival rate in LiEL group was higher than LiE group (P = 0.003; LiEL vs LiE, P = 0.008; LiEL vs LiL, P = 0.001). The time to first heart beat in LiEL group was shorter than LiE, LiL groups. (P < 0.001; LiE vs LiEL, P = 0.001; LiL vs LiEL, P < 0.001). The time to ROSC in LiEL group was shorter than LiE, LiL groups (P < 0.001; LiEL vs LiE, P < 0.001; LiEL vs LiL, P < 0.001). The result was similar for the bupivacaine concentration of cardiac tissue and plasma (cardiac tissue: P = 0.002; plasma: P = 0.011). Furthermore, there were significant differences in the blood-gas values at 40 min, wet-to-dry lung weight ratio, and ratio of damaged alveoli among groups. The LiEL group had the best result for all parameters (P < 0.01, P = 0.008, P < 0.001, respectively). Additionally, significantly less epinephrine was used in the LiEL group (P < 0.001). Levosimendan combined with epinephrine may be superior to either drug alone for lipid-based resuscitation in a rat model of bupivacaine-induced cardiac arrest. The drug combination was associated with a higher survival rate as well as decreased epinephrine consumption and lung damage.
- Open Access
- 30 July 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 60
Measurement of the efficacy of 2% lipid in reversing bupivacaine- induced asystole in isolated rat hearts
The reversal efficacy of 2% lipid emulsion in cardiac asystole induced by different concentrations of bupivacaine is poorly defined and needs to be determined.
- 30 July 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 60
Open AccessMeasurement of the efficacy of 2% lipid in reversing bupivacaine- induced asystole in isolated rat hearts
The reversal efficacy of 2% lipid emulsion in cardiac asystole induced by different concentrations of bupivacaine is poorly defined and needs to be determined.
- 19 July 2011
- Vol. 91 (27) , 1909-13
[Evaluation of safety and anesthetic effect for ultrasound-guided cervical plexus block].
To observe the influences upon the degree of diaphragmatic excursion during deep cervical plexus block at the third cervical vertebra (C3) and compare the safety and anesthetic effect of modified cervical plexus block by ultrasonic guidance and blocking of cervical plexus at one point. Part I: 30 patients of ASA (American society of anesthesiologists) I-II scheduled for thyroid surgery were selected for bilateral cervical plexus block at C3 and bilateral skin nerve branches via ultrasonic guidance. Diaphragmatic excursion was recorded. Part II: 80 patients of ASAI-II scheduled for thyroid surgery were randomly divided into 2 groups: experimental group (Group U) and control group (Group C). In Group U, modified cervical plexus block was used to fix both sides of C3 and skin nerve branches. The anesthetic mixture with 2% lidocaine and 0.75% ropivacaine was injected. And anesthetic effects and complications were detected. In control group, traditional one-point method for blocking cervical plexus was employed. High-frequency Doppler sonography could clearly visualize important neck structures and precisely guide the injection of mixture to the transverse process of C3. Diaphragmatic excursion decreased significantly at 15 and 30 min post-blocking (P < 0.05). And no paralysis of diaphragmatic muscle occurred. Hoverer 3 cases had partial diaphragmatic paralysis. Both blood pressure and heart rate increased significantly post-blocking in both groups (P < 0.05 or 0.01). In comparison with Group C, the range of blood pressure was notably lower at 10 and 20 min in Group U. And heart rate was notably lower at 5, 10, 20 and 30 min (P < 0.05 or 0.01). Furthermore the onset time of skin nerve branches was significantly shorter in Group U (P < 0.01). And the anesthetic effect score was better than that in Group C (P < 0.01). The incidence of complications, such as hoarseness, was significantly lower in Group U (12 cases in Group C but none in Group U, P < 0.01) and Horner's syndrome (2 cases in Group C). The number of cases requiring hypotensor and heart rate control drug was significantly smaller in Group U than that in Group C (P < 0.01). The improving effect of ultrasound-guided cervical plexus block upon the degree of diaphragmatic movement is within the compensatory range of body. In comparison with the traditional one-point blocking of cervical plexus, the modified cervical plexus block with ultrasonic guidance offers better anesthetic effects, fewer complications and convenient anesthetic localization. Thus it may be clinically applicable.
- 19 July 2011
- Vol. 91 (27) , 1909-13
[Evaluation of safety and anesthetic effect for ultrasound-guided cervical plexus block].
To observe the influences upon the degree of diaphragmatic excursion during deep cervical plexus block at the third cervical vertebra (C3) and compare the safety and anesthetic effect of modified cervical plexus block by ultrasonic guidance and blocking of cervical plexus at one point. Part I: 30 patients of ASA (American society of anesthesiologists) I-II scheduled for thyroid surgery were selected for bilateral cervical plexus block at C3 and bilateral skin nerve branches via ultrasonic guidance. Diaphragmatic excursion was recorded. Part II: 80 patients of ASAI-II scheduled for thyroid surgery were randomly divided into 2 groups: experimental group (Group U) and control group (Group C). In Group U, modified cervical plexus block was used to fix both sides of C3 and skin nerve branches. The anesthetic mixture with 2% lidocaine and 0.75% ropivacaine was injected. And anesthetic effects and complications were detected. In control group, traditional one-point method for blocking cervical plexus was employed. High-frequency Doppler sonography could clearly visualize important neck structures and precisely guide the injection of mixture to the transverse process of C3. Diaphragmatic excursion decreased significantly at 15 and 30 min post-blocking (P < 0.05). And no paralysis of diaphragmatic muscle occurred. Hoverer 3 cases had partial diaphragmatic paralysis. Both blood pressure and heart rate increased significantly post-blocking in both groups (P < 0.05 or 0.01). In comparison with Group C, the range of blood pressure was notably lower at 10 and 20 min in Group U. And heart rate was notably lower at 5, 10, 20 and 30 min (P < 0.05 or 0.01). Furthermore the onset time of skin nerve branches was significantly shorter in Group U (P < 0.01). And the anesthetic effect score was better than that in Group C (P < 0.01). The incidence of complications, such as hoarseness, was significantly lower in Group U (12 cases in Group C but none in Group U, P < 0.01) and Horner's syndrome (2 cases in Group C). The number of cases requiring hypotensor and heart rate control drug was significantly smaller in Group U than that in Group C (P < 0.01). The improving effect of ultrasound-guided cervical plexus block upon the degree of diaphragmatic movement is within the compensatory range of body. In comparison with the traditional one-point blocking of cervical plexus, the modified cervical plexus block with ultrasonic guidance offers better anesthetic effects, fewer complications and convenient anesthetic localization. Thus it may be clinically applicable.
- 7 July 2009
- Vol. 89 (25) , 1787-90
[Effects of lipid emulsion on hemodynamics and pharmacokinetics of mongrel dogs with bupivacaine-induced cardiac depression].
To investigate the effects of Intralipid injection on hemodynamics and pharmacodynamics of mongrel dogs with bupivacaine-induced cardiac depression. Fourteen dogs were randomly divided into Intralipid injection group (the experiment group) and normal saline group (the control group). 0.5% bupivacaine was administrated at a constant rate until the mean arterial pressure (MAP) decreased to 60% of the basic value. Intralipid injection was administered in the experiment group. The hemodynamic parameters were recorded and blood samples were taken from femoral artery at 0, 5, 10, 15, 20, 30, 45, 60, 90, 120, 180, 240 min after stopping bupivacaine infusion for determination of plasma concentration by HPLC. The pharmacokinetic parameters were calculated by Drug and Statistics soft version 2.0. After the treatment of Intralipid injection, MAP, CO, HR increased significantly, compared to those of the control group (P < 0.05). The AUC(o-t) was (192 +/- 34)mg x L(-1) x min(-1) versus (271 +/- 81) mg x L(-1) x min(-1) and the AUC(0-infinity) was (231 +/- 62) mg x L(-1) x min(-1) versus (368 +/- 140) mg x L(-1) x min(-1) in the experiment group and the control group respectively. Vz (4.5 +/- 1.1 L/kg versus 3.3 +/- 0.9 L/kg) of bupivacaine in the experiment group was significantly higher than that in the control group (P < 0.05). Intravenous infusion of Intralipid have beneficial effects on the hemodynamics of mongrel dogs with bupivacaine-induced cardiac depression. One of the mechanism of the beneficial effects was probably that Intralipid injection increases the apparent volume of bupivacaine distribution and that decreases blood concentration. [Key words]
- 7 July 2009
- Vol. 89 (25) , 1787-90
[Effects of lipid emulsion on hemodynamics and pharmacokinetics of mongrel dogs with bupivacaine-induced cardiac depression].
To investigate the effects of Intralipid injection on hemodynamics and pharmacodynamics of mongrel dogs with bupivacaine-induced cardiac depression. Fourteen dogs were randomly divided into Intralipid injection group (the experiment group) and normal saline group (the control group). 0.5% bupivacaine was administrated at a constant rate until the mean arterial pressure (MAP) decreased to 60% of the basic value. Intralipid injection was administered in the experiment group. The hemodynamic parameters were recorded and blood samples were taken from femoral artery at 0, 5, 10, 15, 20, 30, 45, 60, 90, 120, 180, 240 min after stopping bupivacaine infusion for determination of plasma concentration by HPLC. The pharmacokinetic parameters were calculated by Drug and Statistics soft version 2.0. After the treatment of Intralipid injection, MAP, CO, HR increased significantly, compared to those of the control group (P < 0.05). The AUC(o-t) was (192 +/- 34)mg x L(-1) x min(-1) versus (271 +/- 81) mg x L(-1) x min(-1) and the AUC(0-infinity) was (231 +/- 62) mg x L(-1) x min(-1) versus (368 +/- 140) mg x L(-1) x min(-1) in the experiment group and the control group respectively. Vz (4.5 +/- 1.1 L/kg versus 3.3 +/- 0.9 L/kg) of bupivacaine in the experiment group was significantly higher than that in the control group (P < 0.05). Intravenous infusion of Intralipid have beneficial effects on the hemodynamics of mongrel dogs with bupivacaine-induced cardiac depression. One of the mechanism of the beneficial effects was probably that Intralipid injection increases the apparent volume of bupivacaine distribution and that decreases blood concentration. [Key words]
- 14 October 2008
- Vol. 88 (37) , 2614-7
[Comparison of lumbar plexus block and epidural block for elderly patients undergoing intertrochanteric femoral fracture surgery].
To compare the anesthesia efficacy, hemodynamics, recovery of passage of gas by anus and bladder function in elderly patients with operation of intertrochanteric femoral fracture with epidural or lumbar plexus block. Sixty patients with intertrochanteric femoral fracture, aged 65-97, were randomly divided into 3 equal groups: lumbar plexus group (Group A, undergoing posterior lumbar plexus block) and epidural group (Group B, undergoing epidural block at L(1-2) interspace). The block onset time, anesthesia efficacy, transfusion amount during operation, blood pressure and heart rate change 1 h after anesthesia, and recovery after anesthesia were observed. The block onset time on femoral nerve, lateral cutaneous nerve of thigh, obturator nerve, and saphenous nerve of Group A were (2.7 +/- 2.0) min, (3.1 +/- 3.4) min, (3.5 +/- 3.3) min, and (3.7 +/- 3.1) min respectively, all significantly shorter than those of Group B [(13.5 +/- 2.1) min, (13.5 +/- 2.1) min, (13.5 +/- 2.1) min, and (13.5 +/- 2.1) min respectively, all P < 0.01]. The duration of postoperative analgesia of Group A was (420 +/- 152) min, significantly longer than that of Group B [(204 +/- 44) min, P < 0.05]. There were no significant differences in the change of blood pressure and heart rate between these 2 groups. The blood pressure decreased significantly 10 - 60 min after anesthesia in Group B, and remained stable in Group A. The transfusion amount of Group A was (773 +/- 353) ml, significantly fewer than that in Group B [(1483 +/- 444) ml, P < 0.01]. Passage of gas by anus started (1.1 +/- 0.6) h after operation in Group A, a time significantly shorter than that in Group B (5.9 +/- 1.2) h, P < 0.01). Urinary retention was seen in 8 patients of Group B, however, no patient in Group A showed incidence of urinary retention (P < 0.01). Forty-eight patients, 20 in Group A and 28 in Group B got excellent anesthesia effect, and 12 of them, 10 in Group A and 2 in Group B, got relatively good anesthesia (P < 0.05). Both lumbar plexus block and epidural block provide satisfactory anesthetic efficacy for operation of intertrochanteric femoral fracture in elderly patients. Epidural block provide better efficacy, and lumbar plexus block shows faster recovery of digestive system and urinary system after operation.
- 14 October 2008
- Vol. 88 (37) , 2614-7
[Comparison of lumbar plexus block and epidural block for elderly patients undergoing intertrochanteric femoral fracture surgery].
To compare the anesthesia efficacy, hemodynamics, recovery of passage of gas by anus and bladder function in elderly patients with operation of intertrochanteric femoral fracture with epidural or lumbar plexus block. Sixty patients with intertrochanteric femoral fracture, aged 65-97, were randomly divided into 3 equal groups: lumbar plexus group (Group A, undergoing posterior lumbar plexus block) and epidural group (Group B, undergoing epidural block at L(1-2) interspace). The block onset time, anesthesia efficacy, transfusion amount during operation, blood pressure and heart rate change 1 h after anesthesia, and recovery after anesthesia were observed. The block onset time on femoral nerve, lateral cutaneous nerve of thigh, obturator nerve, and saphenous nerve of Group A were (2.7 +/- 2.0) min, (3.1 +/- 3.4) min, (3.5 +/- 3.3) min, and (3.7 +/- 3.1) min respectively, all significantly shorter than those of Group B [(13.5 +/- 2.1) min, (13.5 +/- 2.1) min, (13.5 +/- 2.1) min, and (13.5 +/- 2.1) min respectively, all P < 0.01]. The duration of postoperative analgesia of Group A was (420 +/- 152) min, significantly longer than that of Group B [(204 +/- 44) min, P < 0.05]. There were no significant differences in the change of blood pressure and heart rate between these 2 groups. The blood pressure decreased significantly 10 - 60 min after anesthesia in Group B, and remained stable in Group A. The transfusion amount of Group A was (773 +/- 353) ml, significantly fewer than that in Group B [(1483 +/- 444) ml, P < 0.01]. Passage of gas by anus started (1.1 +/- 0.6) h after operation in Group A, a time significantly shorter than that in Group B (5.9 +/- 1.2) h, P < 0.01). Urinary retention was seen in 8 patients of Group B, however, no patient in Group A showed incidence of urinary retention (P < 0.01). Forty-eight patients, 20 in Group A and 28 in Group B got excellent anesthesia effect, and 12 of them, 10 in Group A and 2 in Group B, got relatively good anesthesia (P < 0.05). Both lumbar plexus block and epidural block provide satisfactory anesthetic efficacy for operation of intertrochanteric femoral fracture in elderly patients. Epidural block provide better efficacy, and lumbar plexus block shows faster recovery of digestive system and urinary system after operation.