Eizo Miyashita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Eizo Miyashita has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Yasuhiko Tamai
Department of Physiology, Wakayama Medical College, 27 Kyubancho, Wakayama 640, Japan
7 shared publications- Yuki Ueyama
National Defense Academy of Japan
5 shared publications Mitsukazu Nakai
4 shared publications- Asaf Keller
Department of Neurobiology and UM-MIND, University of Maryland School of Medicine, Baltimore, MD 21201
2 shared publications H. Asanuma
Rockefeller University, New York, New York 10021
2 shared publicationsKatsumi Nakajima
2 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 440
Neuroscience-Inspired Deep Learning Brain–Machine Interface Decoder
Brain–machine interfaces (BMIs) aim to decode motor intentions from neural activity to enable direct control of external devices. However, most existing decoders rely on monolithic architectures that fail to capture the distinct neural representations of different joint movement directions, limiting their generalizability. In this work, we propose a Single-Direction CNN-LSTM decoder inspired by motor cortex encoding mechanisms, which separately models extension and flexion dynamics through parallel CNN-LSTM branches. Each branch extracts spatial–temporal features from neural spike data and predicts directional joint variables, which are then combined by subtraction to yield the net angular velocity and torque of upper-limb joints. Using invasive recordings from a macaque during a 2D center-out reaching task, we demonstrate that our decoder achieves comparable performance to a conventional CNN-LSTM when trained on all tasks, while significantly outperforming both CNN-LSTM and linear regression baselines in cross-target generalization scenarios. Moreover, the model can capture physiologically meaningful co-contraction patterns, providing richer insights into motor control. These results suggest that incorporating neuroscience-inspired modular decoding into deep neural architectures enhances robustness and adaptability across tasks, offering a promising pathway for BMI applications in prosthetics and rehabilitation.
- 10 April 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (4) , 440
Open AccessNeuroscience-Inspired Deep Learning Brain–Machine Interface Decoder
Brain–machine interfaces (BMIs) aim to decode motor intentions from neural activity to enable direct control of external devices. However, most existing decoders rely on monolithic architectures that fail to capture the distinct neural representations of different joint movement directions, limiting their generalizability. In this work, we propose a Single-Direction CNN-LSTM decoder inspired by motor cortex encoding mechanisms, which separately models extension and flexion dynamics through parallel CNN-LSTM branches. Each branch extracts spatial–temporal features from neural spike data and predicts directional joint variables, which are then combined by subtraction to yield the net angular velocity and torque of upper-limb joints. Using invasive recordings from a macaque during a 2D center-out reaching task, we demonstrate that our decoder achieves comparable performance to a conventional CNN-LSTM when trained on all tasks, while significantly outperforming both CNN-LSTM and linear regression baselines in cross-target generalization scenarios. Moreover, the model can capture physiologically meaningful co-contraction patterns, providing richer insights into motor control. These results suggest that incorporating neuroscience-inspired modular decoding into deep neural architectures enhances robustness and adaptability across tasks, offering a promising pathway for BMI applications in prosthetics and rehabilitation.
- Open Access
- 15 September 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (21)
Flexible Thin‐Film Neural Electrodes with Improved Conformability for ECoG Measurements and Electrical Stimulation
Neural electrodes for electrocorticography (ECoG) recording and electrical stimulation are used for diagnosis and treatment of epilepsy, which are temporarily attached to the surface of cerebral cortex within the subdural space. However, conventional electrodes have a mechanical mismatch with the surface curvature of the brain cortex. Thus, it is necessary to develop a thin and flexible ECoG electrode to overcome the mechanical mismatch with cortex tissue and achieve long‐term ECoG measurement. Herein, a flexible thin‐film electrode is reported with a thickness of ≈8 µm by exploiting printed electronics. A simple fabrication method of conductive wiring is proposed by inkjet printing Au nanoink on a flexible elastomeric thin film consisting of polystyrene‐block‐polybutadiene‐block‐polystyrene (SBS). The conductive wiring printed on the SBS thin film is encapsulated by another SBS thin film as an insulation layer, with laser‐processed micropatterns. The flexible thin‐film electrode is implanted on the cortical surface of rats and used for in vivo ECoG recording and electrical stimulation without the occurrence of severe inflammatory reactions after 6 weeks of implantation. The flexible electrode with 35 ECoG channels visualized the epileptiform activity in a drug‐induced epilepsy rat model, which demonstrates the potential application for the management of intractable epilepsy.
- 15 September 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (21)
Open AccessFlexible Thin‐Film Neural Electrodes with Improved Conformability for ECoG Measurements and Electrical Stimulation
Neural electrodes for electrocorticography (ECoG) recording and electrical stimulation are used for diagnosis and treatment of epilepsy, which are temporarily attached to the surface of cerebral cortex within the subdural space. However, conventional electrodes have a mechanical mismatch with the surface curvature of the brain cortex. Thus, it is necessary to develop a thin and flexible ECoG electrode to overcome the mechanical mismatch with cortex tissue and achieve long‐term ECoG measurement. Herein, a flexible thin‐film electrode is reported with a thickness of ≈8 µm by exploiting printed electronics. A simple fabrication method of conductive wiring is proposed by inkjet printing Au nanoink on a flexible elastomeric thin film consisting of polystyrene‐block‐polybutadiene‐block‐polystyrene (SBS). The conductive wiring printed on the SBS thin film is encapsulated by another SBS thin film as an insulation layer, with laser‐processed micropatterns. The flexible thin‐film electrode is implanted on the cortical surface of rats and used for in vivo ECoG recording and electrical stimulation without the occurrence of severe inflammatory reactions after 6 weeks of implantation. The flexible electrode with 35 ECoG channels visualized the epileptiform activity in a drug‐induced epilepsy rat model, which demonstrates the potential application for the management of intractable epilepsy.
- Open Access
- 20 August 2022
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 34 (4) , 817-827
A Motor Adaptation Model Assuming Update of Internal Model in the Motor Cortex
When considering the human motor-adaptation mechanism from the perspective of the motor control theory, updating the internal model constitutes a critical component. The learning curve at each trial of motion can be explained by a state-space model; however, the model cannot reproduce the time-series data for the hand’s position, velocity, and acceleration (motion profiles). There is no internal model-updating rule for optimal feedback control, a plausible model for reproducing motion profiles. In this paper, we propose an adaptation model that incorporates an internal model-updating rule which modeled after Hebb’s rule into optimal feedback control. Also, we examine the neural substrate of the internal model. To validate the proposed adaptation model, we conducted behavioral experiments with humans that reflected changes in the internal model and reproduced the changes in the internal model as well as the motion profiles using the proposed adaptation model. In addition, we analyzed the data for a visuomotor rotation task performed by a monkey and checked for changes in the output characteristics of neurons in the motor cortex before and after adaptation. According to the above-mentioned validation and analysis results, the motor cortex constitutes the neural substrate of the internal model.
- 20 August 2022
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 34 (4) , 817-827
Open AccessA Motor Adaptation Model Assuming Update of Internal Model in the Motor Cortex
When considering the human motor-adaptation mechanism from the perspective of the motor control theory, updating the internal model constitutes a critical component. The learning curve at each trial of motion can be explained by a state-space model; however, the model cannot reproduce the time-series data for the hand’s position, velocity, and acceleration (motion profiles). There is no internal model-updating rule for optimal feedback control, a plausible model for reproducing motion profiles. In this paper, we propose an adaptation model that incorporates an internal model-updating rule which modeled after Hebb’s rule into optimal feedback control. Also, we examine the neural substrate of the internal model. To validate the proposed adaptation model, we conducted behavioral experiments with humans that reflected changes in the internal model and reproduced the changes in the internal model as well as the motion profiles using the proposed adaptation model. In addition, we analyzed the data for a visuomotor rotation task performed by a monkey and checked for changes in the output characteristics of neurons in the motor cortex before and after adaptation. According to the above-mentioned validation and analysis results, the motor cortex constitutes the neural substrate of the internal model.
- Open Access
- 28 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3066
Functional Roles of Saccades for a Hand Movement
An eye saccade provides appropriate visual information for motor control. The present study was aimed to reveal the role of saccades in hand movements. Two types of movements, i.e., hitting and circle-drawing movements, were adopted, and saccades during the movements were classified as either a leading saccade (LS) or catching saccade (CS) depending on the relative gaze position of the saccade to the hand position. The ratio of types of the saccades during the movements was heavily dependent on the skillfulness of the subjects. In the late phase of the movements in a less skillful subject, CS tended to occur in less precise movements, and precision of the movement tended to be improved in the subsequent movement in the hitting. While LS directing gaze to a target point was observed in both types of the movements regardless of skillfulness of the subjects, LS in between a start point and a target point, which led gaze to a local minimum variance point on a hand movement trajectory, was exclusively found in the drawing in a less skillful subject. These results suggest that LS and some types of CS may provide positional information of via-points in addition to a target point and visual information to improve precision of a feedforward controller in the brain, respectively.
- 28 April 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3066
Open AccessFunctional Roles of Saccades for a Hand Movement
An eye saccade provides appropriate visual information for motor control. The present study was aimed to reveal the role of saccades in hand movements. Two types of movements, i.e., hitting and circle-drawing movements, were adopted, and saccades during the movements were classified as either a leading saccade (LS) or catching saccade (CS) depending on the relative gaze position of the saccade to the hand position. The ratio of types of the saccades during the movements was heavily dependent on the skillfulness of the subjects. In the late phase of the movements in a less skillful subject, CS tended to occur in less precise movements, and precision of the movement tended to be improved in the subsequent movement in the hitting. While LS directing gaze to a target point was observed in both types of the movements regardless of skillfulness of the subjects, LS in between a start point and a target point, which led gaze to a local minimum variance point on a hand movement trajectory, was exclusively found in the drawing in a less skillful subject. These results suggest that LS and some types of CS may provide positional information of via-points in addition to a target point and visual information to improve precision of a feedforward controller in the brain, respectively.
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 5 (4) , 296-302
Understanding Motion Control of the Body Using Optimal Feedback Control
- 1 January 2016
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 5 (4) , 296-302
Understanding Motion Control of the Body Using Optimal Feedback Control
- Open Access
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 63 (3) , 1943-1952
State Variables of the Arm May Be Encoded by Single Neuron Activity in the Monkey Motor Cortex
Revealing the type of information encoded by neurons activity in the motor cortex is essential not only for understanding the mechanism of motion control but also for developing a brain-machine interface. Thus far, the concept of preferred direction (PD) vector has dominated the discussion regarding how neural activity encodes information; however, a unified view of exactly what information is encoded has not yet been established. In this study, a model was constructed to describe temporal neuron activity by a dot product of the PD and the movement variables vector consisting of joint torque and angular velocity. The plausibility of this model was tested by comparing estimated neural activity with that recorded from the monkey motor cortex, and it was found that this model was able to explain the temporal pattern of neuron activity irrespective of its passive responsiveness. The mean determination coefficients of neurons that responded to proprioceptive stimuli and that responded to visual stimuli were relatively high values of 0.57 and 0.58, respectively. These results suggest that neurons in the monkey motor cortex encode state variables of the arm in a framework of modern control theory and that this information could be decoded for controlling a brain-machine interface.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 63 (3) , 1943-1952
Open AccessState Variables of the Arm May Be Encoded by Single Neuron Activity in the Monkey Motor Cortex
Revealing the type of information encoded by neurons activity in the motor cortex is essential not only for understanding the mechanism of motion control but also for developing a brain-machine interface. Thus far, the concept of preferred direction (PD) vector has dominated the discussion regarding how neural activity encodes information; however, a unified view of exactly what information is encoded has not yet been established. In this study, a model was constructed to describe temporal neuron activity by a dot product of the PD and the movement variables vector consisting of joint torque and angular velocity. The plausibility of this model was tested by comparing estimated neural activity with that recorded from the monkey motor cortex, and it was found that this model was able to explain the temporal pattern of neuron activity irrespective of its passive responsiveness. The mean determination coefficients of neurons that responded to proprioceptive stimuli and that responded to visual stimuli were relatively high values of 0.57 and 0.58, respectively. These results suggest that neurons in the monkey motor cortex encode state variables of the arm in a framework of modern control theory and that this information could be decoded for controlling a brain-machine interface.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 191-196
Suggestive evidence for a forward model of the arm in the monkey motor cortex
To test an idea that neurons in the motor cortex encodes a future state of the arm, we constructed a plausible model using arm state-related variables to explain neuronal activity, and applied a multiple linear regression analysis. We found that the model fit was fairly good with a mean determination coefficient of 0.57 for analyzed 231 neurons and that neuronal activity preceded the actual movement of the arm with 66 ms on average. Presuming that the brain follows optimal feed back control theory, these findings suggest that the motor cortex may contain a forward model of the arm.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 191-196
Suggestive evidence for a forward model of the arm in the monkey motor cortex
To test an idea that neurons in the motor cortex encodes a future state of the arm, we constructed a plausible model using arm state-related variables to explain neuronal activity, and applied a multiple linear regression analysis. We found that the model fit was fairly good with a mean determination coefficient of 0.57 for analyzed 231 neurons and that neuronal activity preceded the actual movement of the arm with 66 ms on average. Presuming that the brain follows optimal feed back control theory, these findings suggest that the motor cortex may contain a forward model of the arm.
- 16 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 61 (2) , 1044-1052
Optimal Feedback Control for Predicting Dynamic Stiffness During Arm Movement
Knowledge of the central nervous system (CNS) that constrains dimensions of freedom to control a redundant system of the body would provide inspiration for the robotic engineering. We estimated limb stiffness in Japanese monkeys (Macaca fuscata) during arm reaching movements using a robotic manipulandum and carried out numerical simulations. The estimated joint stiffness showed a diphasic pattern, and the end-point stiffness ellipses were modulated during the movement in a characteristic manner. The pattern of limb stiffness was reproduced by the numerical simulation using a musculoskeletal arm model and an approximate optimal feedback control (OFC). Although the arm model has a redundant system with multiple dimensions of freedom, the OFC minimized the redundancy by enhancing the task-relevant cost function. We suggest that the CNS may control the body according to a similar OFC law, and the knowledge might be useful for developing human-machine systems.
- 16 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 61 (2) , 1044-1052
Optimal Feedback Control for Predicting Dynamic Stiffness During Arm Movement
Knowledge of the central nervous system (CNS) that constrains dimensions of freedom to control a redundant system of the body would provide inspiration for the robotic engineering. We estimated limb stiffness in Japanese monkeys (Macaca fuscata) during arm reaching movements using a robotic manipulandum and carried out numerical simulations. The estimated joint stiffness showed a diphasic pattern, and the end-point stiffness ellipses were modulated during the movement in a characteristic manner. The pattern of limb stiffness was reproduced by the numerical simulation using a musculoskeletal arm model and an approximate optimal feedback control (OFC). Although the arm model has a redundant system with multiple dimensions of freedom, the OFC minimized the redundancy by enhancing the task-relevant cost function. We suggest that the CNS may control the body according to a similar OFC law, and the knowledge might be useful for developing human-machine systems.
- 1 May 2013
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 41 (3) , 251-273
DEVISING A ROBOTIC ARM MANIPULANDUM FOR NORMAL AND ALTERED REACHING MOVEMENTS TO INVESTIGATE BRAIN MECHANISMS OF MOTOR CONTROL
The objective of this work was to develop a manipulandum system capable of measuring a monkey's arm movements and applying extrinsic forces to the hand. The manipulandum (RANARM) was designed as a five-bar linkage mechanism in order to realize sufficient rigidity and efficient force transmission. In addition, RANARM's control enables it to cancel its own dynamics by calculating the inverse dynamics. We evaluated the performance of RANARM from the mechanism, control, and application points of view. From the mechanism point of view, RANARM was able to provide a sufficiently large workspace for experiments, where it exhibited high manipulability and the capacity to apply force perturbations of at least 12 N under static conditions, and 5.3 N under dynamic conditions. From the control point of view, we estimated the uncompensated dynamics of RANARM to be negligibly small. Finally, we evaluated the performance of a monkey operating RANARM, and observed that the hand speed profiles followed a natural bell shape, while the maximal speeds were high (i.e., 15-cm reaching within 500 ms). In conclusion, RANARM allows a monkey to execute rapid movement and it is an efficient apparatus for investigating brain mechanisms for generating voluntary movements.
- 1 May 2013
- Published by Taylor & Francis in Instrumentation Science & Technology
- Vol. 41 (3) , 251-273
DEVISING A ROBOTIC ARM MANIPULANDUM FOR NORMAL AND ALTERED REACHING MOVEMENTS TO INVESTIGATE BRAIN MECHANISMS OF MOTOR CONTROL
The objective of this work was to develop a manipulandum system capable of measuring a monkey's arm movements and applying extrinsic forces to the hand. The manipulandum (RANARM) was designed as a five-bar linkage mechanism in order to realize sufficient rigidity and efficient force transmission. In addition, RANARM's control enables it to cancel its own dynamics by calculating the inverse dynamics. We evaluated the performance of RANARM from the mechanism, control, and application points of view. From the mechanism point of view, RANARM was able to provide a sufficiently large workspace for experiments, where it exhibited high manipulability and the capacity to apply force perturbations of at least 12 N under static conditions, and 5.3 N under dynamic conditions. From the control point of view, we estimated the uncompensated dynamics of RANARM to be negligibly small. Finally, we evaluated the performance of a monkey operating RANARM, and observed that the hand speed profiles followed a natural bell shape, while the maximal speeds were high (i.e., 15-cm reaching within 500 ms). In conclusion, RANARM allows a monkey to execute rapid movement and it is an efficient apparatus for investigating brain mechanisms for generating voluntary movements.
- 1 February 2013
- Published by Bentham Science Publishers Ltd. in Current Bioinformatics
- Vol. 8 (1) , 16-24
Signal-Dependent Noise Induces Muscle Co-Contraction to Achieve Required Movement Accuracy: A Simulation Study with an Optimal Control
- 1 February 2013
- Published by Bentham Science Publishers Ltd. in Current Bioinformatics
- Vol. 8 (1) , 16-24
Signal-Dependent Noise Induces Muscle Co-Contraction to Achieve Required Movement Accuracy: A Simulation Study with an Optimal Control