Peter Lamb

Peter Lamb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Lamb has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Movement Strategy Modulation during the Posterolateral Reach of the Star Excursion Balance Test following Anterior Cruciate Ligament Reconstruction

    by Shojiro Nozu, Peter Lamb, Allan Carman, Tadamitsu Matsuda, Gisela Sole

    Background: Altered lower-limb biomechanics are evident following anterior cruciate ligament reconstruction (ACLR) during dynamic tasks, which may be associated with increased reinjury risk and the development of knee osteoarthritis. This study aimed toinvestigate movement strategy differences during the posterolateral reach of the Star Excursion Balance Test (SEBT) between individuals with ACLR and knee-healthy controls, and to examine the modifiability of these movement strategies in response to medial and lateral heel wedges.Methods: Twenty-four ACLR participants (18 female) and 24 healthy controls (15 females) participated. The maximum reach distance of the posterolateral direction of the SEBT and lower limb and trunk kinematics were analysed under three conditions: standard laboratory running shoe (no inserts, neutral), 5-mm laterally-wedged heel insert (lateral), and 5-mm medially-wedged insert (medial). Statistical parametric mapping (SPM) was used to analyse kinetic and kinematic trajectories.Findings: The ACLR group demonstrated shorter posterolateral reach, less ankle dorsiflexion, knee and hip flexion, hip external rotation, and trunk lateral flexion compared to healthy controls. The use of medial or lateral heel wedges did not influence reach distance or movement patterns in either group.Interpretation: Individuals with ACLR exhibited altered movement strategies during the posterolateral reach of the SEBT compared with controls. These strategies were not modified by medial or lateral heel wedges, suggesting limited responsiveness of the observed movement patterns to small changes in external mechanical input.

  • Open Access

    Morphological comparison of the paretic to the non-paretic knee in people with stroke: An exploratory study

    by Clifford P. Waller, Stephanie J. Woodley, Leigh Hale, Allyson Calder, Grant Meikle, Suzanne Kuys, Peter Lamb

    Biomechanical differences between the paretic knee (PK) and non-paretic knee (NPK) post-stroke are well documented. Due to limited knowledge of the potential impacts of altered biomechanics on knee morphology, this study aimed to (1) assess and compare gross morphological characteristics of the distal femoral cartilage and patellar tendon in the PK and NPK; (2) compare knee biomechanics; (3) investigate associations between biomechanical and morphological data. This exploratory case-control observational study included seven people with stroke (6 male; M (SD) age, 75.7 (4.5) years). Magnetic resonance imaging was used to assess the femoral articular cartilage (thickness and integrity) and patellar tendon (physical characteristics), alongside optic-based gait analyses. Descriptive and correlational (ρ and τ) analyses were applied. The PK and NPK were morphologically similar. Maximum flexion was reduced at the PK (49.3°; 95%CI [41.9, 56.7]) compared to the NPK (62.7°; 95%CI [57.3, 68.2]). Correlations were observed between maximal PK extension moments and medial condyle chondral thickness (ρ = –0.87, 95%CI [–0.98, –0.32]); maximum PK extension and patellar tendon length (ρ = 0.86, 95%CI [0.27, 0.98]); maximum NPK extension and patellar tendon width (ρ=0.93, 95%CI [0.56, 0.99]); maximum PK valgus and patellar tendon width (ρ = 0.86, 95%CI [0.27, 0.98]); maximum PK flexion moments and patellar tendon length (ρ = 0.93, 95%CI [0.56,0.99]); and NPK maximum extension moments and patellar tendon thickness (ρ = –0.84, 95%CI [0.98, 0.20]). These findings suggest a relationship between biomechanics and knee morphology post-stroke. This study offers insight for physiotherapists working in gait rehabilitation, and for future research.

  • Validation of step time and asymmetry detection algorithm in high-intensity running with Movesense IMU

    by Raúl Martín Gómez, Haye Kamstra, Enzo Allevard, Lucas Pollet-Villard, James Cotter, Peter Lamb

  • Open Access

    Are super shoes a super placebo? A randomised crossover trial in female recreational runners

    by Kim Hébert-Losier, Ashlynne Pfister, Steven J. Finlayson, Jean-Francois Esculier, Peter Lamb, Christopher Martyn Beaven


  • Open Access

    Validity and Reliability of Movesense HR+ ECG Measurements for High-Intensity Running and Cycling

    by Raúl Martín Gómez, Enzo Allevard, Haye Kamstra, James Cotter, Peter Lamb

    Low-cost, portable devices capable of accurate physiological measurements are attractive tools for coaches, athletes, and practitioners. The purpose of this study was primarily to establish the validity and reliability of Movesense HR+ ECG measurements compared to the criterion three-lead ECG, and secondarily, to test the industry leader Garmin HRM. Twenty-one healthy adults participated in running and cycling incremental test protocols to exhaustion, both with rest before and after. Movesense HR+ demonstrated consistent and accurate R-peak detection, with an overall sensitivity of 99.7% and precision of 99.6% compared to the criterion; Garmin HRM sensitivity and precision were 84.7% and 87.7%, respectively. Bland–Altman analysis compared to the criterion indicated mean differences (SD) in RR’ intervals of 0.23 (22.3) ms for Movesense HR+ at rest and 0.38 (18.7) ms during the incremental test. The mean difference for Garmin HRM-Pro at rest was −8.5 (111.5) ms and 27.7 (128.7) ms for the incremental test. The incremental test correlation was very strong (r = 0.98) between Movesense HR+ and criterion, and moderate (r = 0.66) for Garmin HRM-Pro. This study developed a robust peak detection algorithm and data collection protocol for Movesense HR+ and established its validity and reliability for ECG measurement.


  • Biomechanics of the paretic knee during overground gait in people with stroke: a systematic review

    by Clifford Paul Waller, Bahram Sangelaji, Claire Hargest, Stephanie J. Woodley, Peter Lamb, Suzanne Kuys, Allyson Calder, Leigh A. Hale

    Biomechanics of the paretic knee during gait are well documented, yet these data have yet to be systematically summarised and analysed.To analyse three-dimensional optic-based biomechanical data of...


  • Kinematics of recreational male runners in “super”, minimalist and habitual shoes

    by Kim Hébert-Losier, Steven J. Finlayson, Peter F. Lamb, Matthew W. Driller, Ivana Hanzlíková, Blaise Dubois, Jean-Francois Esculier, Christopher Martyn Beaven

    We conducted an exploratory analysis to compare running kinematics of 16 male recreational runners wearing Nike Vaporfly 4% (VP4), Saucony Endorphin racing flat (FLAT), and their habitual (OWN) footwear. We also explored potential relationships between kinematic and physiological changes. Runners (age: 33 ± 12 y, V˙ O2peak: 55.2 ± 4.3 ml · kg−1·min−1) attended 3 sessions after completing an V˙ O2peak test in which sagittal plane 3D kinematics at submaximal running speeds (60%, 70% and 80% ʋ V˙ O2peak) were collected alongside economy measures. Kinematics were compared using notched boxplots, and between-shoe kinematic differences were plotted against between-shoe economy differences. Across intensities, VP4 involved longer flight times (6.7 to 10.0 ms) and lower stance hip range of motion (~3°), and greater vertical pelvis displacement than FLAT (~0.4 cm). Peak dorsiflexion angles (~2°), ankle range of motion (1.0° to 3.9°), and plantarflexion velocities (11.3 to 89.0 deg · sec−1) were greatest in FLAT and lowest in VP4. Foot-ground angles were smaller in FLAT (2.5° to 3.6°). Select kinematic variables were moderately related to economy, with higher step frequencies and shorter step lengths in VP4 and FLAT associated with improved economy versus OWN. Footwear changes from OWN altered running kinematics. The most pronounced differences were observed in ankle, spatiotemporal, and foot-ground angle variables.


  • Open Access

    Immediate and six-week effects of wearing a knee sleeve following anterior cruciate ligament reconstruction on knee kinematics and kinetics: a cross-over laboratory and randomised clinical trial

    by Gisela Sole, Peter Lamb, Todd Pataky, Anupa Pathak, Stefan Klima, Pierre Navarre, Niels Hammer

    Background: Elastic knee sleeves are often worn following anterior cruciate ligament reconstruction (ACLR) but their effects on movement patterns are unclear. Aim: To determine the immediate and six-week effects of wearing a knee sleeve on biomechanics of the knee during a step-down hop task. Methods: Using a cross-over design, we estimated sagittal plane knee kinematics and kinetics and stance duration during a step-down hop for 31 participants (age 26.0 [SD 6.6] years, 15 women) after ACLR (median 16 months post-surgery) with and without wearing a knee sleeve. In a subsequent randomised clinical trial, participants in the ‘Sleeve Group’ (n = 9) then wore the sleeve for 6 weeks at least 1 h daily, while a ‘Control Group’ (n = 9) did not wear the sleeve. We used statistical parametric mapping to compare (1) knee flexion/extension angle and external flexion/extension moment trajectories between three conditions at baseline (uninjured side, unsleeved injured side and sleeved injured side); (2) within-participant changes for knee flexion angles and external flexion/extension moment trajectories from baseline to follow-up between groups. We compared discrete flexion angles and moments, and stance duration between conditions and between groups. Results: Without sleeves, knee flexion was lower for the injured than the uninjured sides during mid-stance phase. When wearing the sleeve on the injured side, knee flexion increased during the loading phase of the stance phase. Discrete initial and peak knee flexion angles increased by (mean difference, 95% CIs) 2.7° (1.3, 4.1) and 3.0° (1.2, 4.9), respectively, when wearing the knee sleeve. Knee external flexion moments for the unsleeved injured sides were lower than the uninjured sides for 80% of stance phase, with no change when sleeved. The groups differenced for within-group changes in knee flexion trajectories at follow-up. Knee flexion angles increased for the Control group only. Stance duration decreased by 22% for the Sleeve group from baseline to follow-up (-89 ms; -153, -24) but not for the Controls. Conclusions: Application of knee sleeves following ACLR is associated with improved knee flexion angles during hop landing training. Longer term (daily) knee sleeve application may help improve hop stance duration, potentially indicating improved hop performance. Trial registration: The trial was prospectively registered with the Australia New Zealand Clinical Trials Registry No: ACTRN12618001083280, 28/06/2018. ANZCTR


  • The time-continuous association between turnout and axial joint moments in the competitive Irish dance ‘fly’ landing

    by Kelsi Wallace, Sofia Kalogeropoulou, Peter Lamb

    Turnout is a key technical and aesthetic element in competitive Irish dance involving external rotation of the lower limb and must be sustained during landings. ‘Forced’ turnout, aided by floor friction rather than active hip rotation, is likely to result in large internal rotation moments at the knee and ankle, which may increase the risk of injury. The aim of the current study was to establish the relationship between the hip and ankle external rotation vector field and maximum internal rotation moments of the ankle and knee. Thirteen (12 female) competitive Irish dancers performed 10 flys (common Irish dance leap) onto a force plate while being recorded by a ten-camera motion capture system. Time-continuous data were analysed over the duration of landing using statistical parametric mapping (SPM). A positive correlation (p < 0.05) was found between the hip-ankle turnout vector field and maximum ankle internal rotation moments throughout most of the landing. Post-hoc analyses showed that hip external rotation contributed the most to the maximum ankle internal rotation moment (p < 0.05). Increasing hip turnout during landing could reduce internal rotation moments, assuming hip turnout brings the thigh and foot axial orientation more in line with each other.


  • External workload intensity in cricket fast bowlers across maximal and submaximal intensities: Modifying PlayerLoad and IMU location

    by Corey Perrett, Melanie Bussey, Peter Lamb

    Workload is a commonly accepted risk factor for injury among fast bowlers, however many methods exist to characterise workload. Recently, automated intensity-sensitive measures like PlayerLoad have been used to improve the estimation of workload in fast bowlers. The purpose of this study was to determine whether similar variables could be extracted from a single inertial measurement unit (IMU) that highly correlate with intensity, according to release speed. Eight elite and pre-elite bowlers participated in the study, with each bowler bowling one over each at 60%, 80% and 100% intensity and repeating this across two sessions (36 balls per participant). IMUs were placed on the upper-back and non-bowling wrist and maximum PlayerLoad from each delivery (PLmax) was compared to the accumulated value across each delivery (PLacc). The strongest correlation with release speed was with PLacc from the non-bowling wrist (R = 0.74), followed by PLacc from the upper-back (R = 0.65) and PLmax from the upper back (R = 0.60). Consequently, an improved estimation of the intensity at which bowlers are working at could be gained by examining accumulated PlayerLoad values from an IMU on the non-bowling wrist.