VAVenkatesh Aithal

Venkatesh Aithal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Venkatesh Aithal has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Joseph Kei

    Hearing Research Unit for Children, School of Health and Rehabilitation Sciences, The University of Queensland

    13 shared publications
  • Sreedevi Aithal

    Department of Audiology, The Townsville Hospital, Queensland, Australia

    10 shared publications
  • Sreedevi Aithal

    Hearing Research Unit for Children, School of Health and Rehabilitation Sciences, The University of Queensland

    8 shared publications
  • Carlie Driscoll

    Hearing Research Unit for Children, School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia

    6 shared publications
  • Michio Murakoshi

    Faculty of Frontier Engineering, Institute of Science and Engineering, Kanazawa University, Kanazawa, Japan

    6 shared publications
  • Joseph Kei

    Hearing Research Unit for Children, Division of Audiology, School of Health & Rehabilitation Sciences, The University of Queensland, Brisbane, 4072, Australia

    5 shared publications

Latest Publications

  • Open Access

    Immediate test-retest reliability and agreement of wideband absorbance results in infants

    by Katrina Moon, Sreedevi Aithal, Venkatesh Aithal, Joseph Kei

    The present study aimed to evaluate immediate test-retest reliability and agreement of wideband absorbance (WBA) results in infants. A cross-sectional study design was used. Retest for WBA was performed with the probe removed and replaced in the same ear, immediately following the initial measurement. Study sample: A total of 25 infants aged 6-18 months, who passed both tympanometry and distortion product otoacoustic emission tests, participated in this study. Generalized linear mixed model analyses showed no significant difference in WBA between the test and retest conditions. Intraclass correlation coefficients (ICCs) were greater than 0.92 for all but the 250-Hz band, where an ICC of 0.75 with a 95% confidence interval of 0.42-0.89 was obtained. Bland-Altman plots showed mean test-retest differences of less than or equal to 0.0167, with 95% of the data points within the limits of agreement for all frequency bands. Conclusion: Overall, excellent test-retest reliability and agreement of WBA results in infants were established. Although the frequency band of 250 Hz was found to have an ICC consistent with moderate reliability, this region is considered to carry minimal diagnostic information. Findings from this study support the use of WBA with infants for clinical evaluation.

  • Associated factors for parent-reported otitis media in 12-month-old infants

    by Joseph Kei, Ming Wai Jasmine Lee, Joshua Myers, Sreedevi Aithal, Venkatesh Aithal, Carlie Driscoll, Asaduzzaman Khan

    To report host-related and environmental factors associated with otitis media (OM), and compare the prevalence of OM in 12-month-old infants reported by parents with that predicted from audiological assessment results. A non-randomised, cross-sectional design was used. Data were collected via a parental questionnaire during children's audiology appointment at 12 months of age. Audiological assessments were performed on all participants. Participants were 237 infants whose parents had completed a questionnaire at the audiology appointment. The results of the logistic regressions with univariate model showed that attendance at day-care centres, upper respiratory tract infections (URTI) and siblings' history of OM were statistically significant variables with an odds ratio of 1.91, 2.87 and 3.56, respectively. The results of the multivariate logistic regression highlighted siblings' history of OM as the significant associated factor. The prevalence of parent-reported OM was 22.3% whereas the prevalence predicted from audiological findings was at least 39.7%. The present study identified three associated factors for OM: day-care attendance, frequent URTI and siblings' history of OM in infants. The prevalence of OM predicted from audiologic measures was about twice of that reported by parents. Preventive measures to mitigate the effects of OM have been suggested.


  • Predictive Accuracy of Wideband Absorbance at Ambient and Tympanometric Peak Pressure Conditions in Identifying Children with Surgically Confirmed Otitis Media with Effusion

    by Venkatesh Aithal, Sreedevi Aithal, Joseph Kei, Shane Anderson, David Wright

    Background Wideband absorbance (WBA) measured at ambient pressure (WBA(A)) does not directly account for middle ear pressure effects. On the other hand, WBA measured at tympanometric peak pressure (TPP) (WBA(TPP)) may compensate for the middle ear pressure effects. To date, there are no studies that have compared WBA(A) and WBA(TPP) in ears with surgically confirmed otitis media with effusion (OME). Purpose The purpose of this study was to compare the predictive accuracy of WBA(A) and WBA(TPP) in ears with OME. Research Design Prospective cross-sectional study. Study Sample A total of 60 ears from 38 healthy children (mean age = 6.5 years, SD = 1.84 years) and 60 ears from 38 children (mean age = 5.5 years, SD = 3.3 years) with confirmed OME during myringotomy were included in this study. Data Collection and Analysis Results were analyzed using descriptive statistics and analysis of variance. The predictive accuracy of WBA(A) and WBA(TPP) was determined using receiver operating characteristics (ROC) analyses. Results Both WBA(A) and WBA(TPP) were reduced in ears with OME compared with that in healthy ears. The area under the ROC (AROC) curve was 0.92 for WBA(A) at 1.5 kHz, whereas that for WBA(TPP) at 1.25 kHz was 0.91. In comparison, the AROC for 226-Hz tympanometry based on the static acoustic admittance (Y-tm) measure was 0.93. Conclusions Both WBA(A) and WBA(TPP) showed high and similar test performance, but neither test performed significantly better than 226-Hz tympanometry for detection of surgically confirmed OME.


  • Eustachian Tube Dysfunction and Wideband Absorbance Measurements at Tympanometric Peak Pressure and 0 daPa

    by Sreedevi Aithal, Venkatesh Aithal, Joseph Kei, Shane Anderson, Simon Liebenberg

    Background:Although wideband absorbance (WBA) provides important information about middle ear function, there is limited research on the use of WBA to evaluate eustachian tube dysfunction (ETD). To date, WBA obtained under pressurized condition has not been used to evaluate ETD.Purpose:The objective of the study was to compare WBA at 0 daPa and tympanometric peak pressure (TPP) conditions in healthy ears and ears with ETD.Research DesignA cross-sectional study design was used.Study SampleA total of 102 healthy ears from 79 participants (mean age = 10.0 yr) and 43 ears from 32 patients with ETD (mean age = 16.0 yr) were included in this cross-sectional study. WBA was measured at 0 daPa (WBA0) and TPP WBA at TPP (WBATPP).Data Collection and Analysis:WBA results were analyzed using descriptive statistics and t-tests with the Bonferroni correction. An analysis of variance with repeated measures was applied to the data.Results:WBA0 was significantly lower in the ETD group than in the control group. The WBA0 of the control group demonstrated a broad peak between 1.25 and 4 kHz, whereas the WBA0 of the ETD group had a peak between 2.5 and 4 kHz. WBATPP of the ETD group approached values close to that of the control group. In the control group, WBATPP was only 0.06 to 0.09 higher than WBA0, whereas in the ETD group, WBATPP was 0.29 to 0.42 higher than WBA0 between 0.6 and 1.5 kHz. A differential pattern of WBA at TPP relative to 0 daPa was observed between ears with ETD and ears with otitis media with effusion (OME) and negative middle ear pressure (NMEP).Conclusions:Hence, a comparison of WBA0 and WBATPP can provide potentially useful diagnostic information, and hence can be used as an adjunct tool to evaluate ETD. This is important especially in young children or some adults who are unable to perform maneuvers such as Toynbee or Valsalva during ETD assessment. Further research is needed to verify the results using test performance measures to determine whether WBA0 and WBATPP can objectively determine the presence of ETD or OME with NMEP.


  • Effect of Negative Middle Ear Pressure and Compensated Pressure on Wideband Absorbance and Otoacoustic Emissions in Children

    by Sreedevi Aithal, Venkatesh Aithal, Joseph Kei, Alehandrea Manuel

    Objective: This study investigated pressurized transient evoked otoacoustic emission (TEOAE) responses and wideband absorbance (WBA) in healthy ears and ears with negative middle ear pressure (NMEP). Method: In this cross-sectional study, TEOAE amplitude, signal-to-noise ratio, and WBA were measured at ambient and tympanometric peak pressure (TPP) in 36 ears from 25 subjects with healthy ears (age range: 3.1–13.0 years) and 88 ears from 76 patients with NMEP (age range: 2.0–13.1 years), divided into 3 groups based on NMEP (Group 1 with TPP between −101 and −200 daPa, Group 2 with TPP between −201 and −300 daPa, and Group 3 with TPP between −301 and −400 daPa). Results: Mean TEOAE amplitude, signal-to-noise ratio, and WBA were increased at TPP relative to that measured at ambient pressure between 0.8 and 1.5 kHz. Further decrease in TPP beyond −300 daPa did not result in further increases in the mean TEOAE or WBA at TPP. The correlation between TEOAE and WBA was dependent on the frequency, pressure conditions, and subject group. There was no difference in pass rates between the 2 pressure conditions for the control group, while the 3 NMEP groups demonstrated an improvement in pass rates at TPP. With pressurization, the false alarm rate for TEOAE due to NMEP was reduced by 17.8% for NMEP Group 1, 29.2% for NMEP Group 2, and 15.8% for NMEP Group 3. Conclusion: Results demonstrated the feasibility and clinical benefits of measuring TEOAE and WBA under pressurized conditions. Pressurized TEOAE and WBA should be used for assessment of ears with NMEP in hearing screening programs to reduce false alarm rates.


  • Normative Wideband Acoustic Immittance Measurements in Caucasian and Aboriginal Children

    by Venkatesh Aithal, Sreedevi Aithal, Joseph Kei, Alehandrea Manuel

    Purpose: The aims of this study were to develop normative data for wideband acoustic immittance (WAI) measures in Caucasian and Australian Aboriginal children and compare absorbance measured at 0 daPa (WBA(0) ) and tympanometric peak pressure (TPP; WBA(TPP)) between the 2 groups of children. Additional WAI measures included resonance frequency, equivalent ear canal volume, TPP, admittance magnitude (YM), and phase angle (YA). Method: A total of 171 ears from 171 Caucasian children and 87 ears from 87 Aboriginal children who passed a test battery consisting of 226-Hz tympanometry, transient evoked otoacoustic emissions, and pure tone audiometry were included in the study. WAI measures were obtained under pressurized conditions using wideband tympanometry. Data for WBA(0,) WBA(TPP), YM, and YA were averaged in one-third octave frequencies from 0.25 to 8 kHz. Results: There was no significant ear effect on all of the 7 measures for both groups of children. Similarly, there was no significant gender effect on all measures except for WBA(TPP) in Aboriginal children. Aboriginal boys had significantly higher WBA(TPP) than girls at 1.5 and 2 kHz. A significant effect of ethnicity was also noted for WBA(TPP) at 3, 4, and 8 kHz, with Caucasian children demonstrating higher WBA(TPP) than Aboriginal children. However, the effect size and observed power of the analyses were small for both effects. Conclusion: This study developed normative data for 7 WAI measures, namely, WBA(0) , WBA(TPP), TPP, Veq, RF, YM, and YA, for Caucasian and Aboriginal children. In view of the high similarity of the normative data between Caucasian and Aboriginal children, it was concluded that separate ethnic-specific norms are not required for diagnostic purposes.


  • Diagnosing Middle Ear Pathology in 6- to 9-Month-Old Infants Using Wideband Absorbance: A Risk Prediction Model

    by Joshua Myers, Joseph Kei, Sreedevi Aithal, Venkatesh Aithal, Carlie Driscoll, Asaduzzaman Khan, Alehandrea Manuel, Anjali Joseph, Alicja N. Malicka

    Purpose: The aim of this study was to develop a risk prediction model for detecting middle ear pathology in 6- to 9-month-old infants using wideband absorbance measures. Method: Two hundred forty-nine infants aged 23–39 weeks ( Mdn = 28 weeks) participated in the study. Distortion product otoacoustic emissions and high-frequency tympanometry were tested in both ears of each infant to assess middle ear function. Wideband absorbance was measured at ambient pressure in each participant from 226 to 8000 Hz. Absorbance results from 1 ear of each infant were used to predict middle ear dysfunction, using logistic regression. To develop a model likely to generalize to new infants, the number of variables was reduced using principal component analysis, and a penalty was applied when fitting the model. The model was validated using the opposite ears and with bootstrap resampling. Model performance was evaluated through measures of discrimination and calibration. Discrimination was assessed with the area under the receiver operating characteristic curve (AUC); and calibration, with calibration curves, which plotted actual against predicted probabilities. Results: AUC of the fitted model was 0.887. The model validated adequately when applied to the opposite ears (AUC = 0.852) and with bootstrap resampling (AUC = 0.874). Calibration was satisfactory, with high agreement between predictions and observed results. Conclusions: The risk prediction model had accurate discrimination and satisfactory calibration. Validation results indicate that it may generalize well to new infants. The model could potentially be used in diagnostic and screening settings. In the context of screening, probabilities provide an intuitive and flexible mechanism for setting the referral threshold that is sensitive to the costs associated with true and false-positive outcomes. In a diagnostic setting, predictions could be used to supplement visual inspection of absorbance for individualized diagnoses. Further research assessing the performance and impact of the model in these contexts is warranted.


  • Open Access

    Predictive Accuracy of Sweep Frequency Impedance Technology in Identifying Conductive Conditions in Newborns

    by Venkatesh Aithal, Joseph Kei, Carlie Driscoll, Michio Murakoshi, Hiroshi Wada

    Background:Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns.Purpose:The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards.Research Design:Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample.Study Sample:A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr.Data Collection and Analysis:Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity.Results:The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard.Conclusions:The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments.


  • Effect of ear canal pressure and age on wideband absorbance in young infants

    by Sreedevi Aithal, Venkatesh Aithal, Joseph Kei

    Objective: The study investigated the effect of ear canal pressure and age on wideband absorbance (WBA) in healthy young infants. Design: Using a cross-sectional design, WBA at 0.25 to 8 kHz was obtained from infants as the ear canal pressure was swept from +200 to −300 daPa. Study sample: The participants included 29 newborns, 9 infants each at 1 and 4 months and 11 infants at 6 months of age who passed distortion product otoacoustic emissions test. Results: In general, negative-ear canal pressures reduced WBA across the frequency range, while positive-ear canal pressures resulted in reduced WBA from 0.25 to 2 kHz and above 4 kHz with an increase in absorbance between 2 and 3 kHz compared to WBA at ambient pressure. The variation in WBA below 0.5 kHz, as the pressure was varied, was the greatest in newborns. But, the variation was progressively reduced in older infants up to the age of 6 months, suggesting stiffening of the ear canal with age. Conclusions: Significant changes in WBA were observed as a function of pressure and age. In particular, developmental effects on WBA were evident during the first six months of life.


  • Open Access

    Analysis by Sweep Frequency Impedance (SFI) Meter of 226-Hz and 1,000-Hz Tympanometries in Neonates

    by Michio Murakoshi, Kyosuke Sano, Nattikan Kanka, Naoto Yoshida, Shinji Hamanishi, Hiromichi Kiyokawa, Risako Kakuta, Sreedevi Aithal, Venkatesh Aithal, Joseph Kei, et al.