Niels Timmer
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Niels Timmer has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Steven T. J. Droge
Institute for Risk Assessment Sciences, Utrecht University , Utrecht, 3508 TD, The Netherlands
7 shared publications David Gore
Safety and Environmental Assurance Centre, Unilever, Colworth Science Park, Sharnbrook, MK44 1LQ, Bedfordshire, UK
3 shared publicationsDavid Sanders
Safety and Environmental Assurance Centre, Unilever, Colworth Science Park, Sharnbrook, MK44 1LQ, Bedfordshire, UK
3 shared publicationsTodd Gouin
Safety and Environmental Assurance Centre, Unilever, Colworth Science Park, Sharnbrook, MK44 1LQ, Bedfordshire, UK
3 shared publicationsJoop L.M. Hermens
Institute for Risk Assessment Sciences, Utrecht University, P.O. Box 80177, 3508 TD Utrecht, The Netherlands
2 shared publications- Antonia Praetorius
University of Amsterdam
1 shared publication
Latest Publications
- Open Access
- 26 April 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 11 (6) , 2352-2371
Practical considerations to optimize aquatic testing of particulate material, with focus on nanomaterials
Following available approaches included e.g. , in existing OECD Test Guidelines and Guidance Documents for the aquatic testing of particulate materials such as nanomaterials and microplastics leads to various challenges to be considered.
- 26 April 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Nano
- Vol. 11 (6) , 2352-2371
Open AccessPractical considerations to optimize aquatic testing of particulate material, with focus on nanomaterials
Following available approaches included e.g. , in existing OECD Test Guidelines and Guidance Documents for the aquatic testing of particulate materials such as nanomaterials and microplastics leads to various challenges to be considered.
- 16 December 2019
- Published by Elsevier in Chemosphere
- Vol. 245, 125643
Application of seven different clay types in sorbent-modified biodegradability studies with cationic biocides
- 16 December 2019
- Published by Elsevier in Chemosphere
- Vol. 245, 125643
Application of seven different clay types in sorbent-modified biodegradability studies with cationic biocides
- 1 October 2019
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 182, 109417
Sorbent-modified biodegradation studies of the biocidal cationic surfactant cetylpyridinium chloride
- 1 October 2019
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 182, 109417
Sorbent-modified biodegradation studies of the biocidal cationic surfactant cetylpyridinium chloride
- Open Access
- 1 May 2019
- Published by Elsevier in Chemosphere
- Vol. 222, 461-468
Toxicity mitigation and bioaccessibility of the cationic surfactant cetyltrimethylammonium bromide in a sorbent-modified biodegradation study
- 1 May 2019
- Published by Elsevier in Chemosphere
- Vol. 222, 461-468
Open AccessToxicity mitigation and bioaccessibility of the cationic surfactant cetyltrimethylammonium bromide in a sorbent-modified biodegradation study
- Open Access
- 23 April 2019
- Published by American Chemical Society (ACS) in Chemical Research in Toxicology
- Vol. 32 (6) , 1103-1114
Influence of in Vitro Assay Setup on the Apparent Cytotoxic Potency of Benzalkonium Chlorides
The nominal concentration is generally used to express concentration-effect relationships in in vitro toxicity assays. However, the nominal concentration does not necessarily represent the exposure concentration responsible for the observed effect. Surfactants accumulate at interphases and likely sorb to in vitro system components such as serum protein and well plate plastic. The extent of sorption and the consequences of this sorption on in vitro readouts is largely unknown for these chemicals. The aim of this study was to demonstrate the effect of sorption to in vitro components on the observed cytotoxic potency of benzalkonium chlorides (BAC) varying in alkyl chain length (6-18 carbon atoms, C6-18) in a basal cytotoxicity assay with the rainbow trout gill cell line (RTgill-W1). Cells were exposed for 48h in 96-well plates to increasing concentration of BACs in exposure medium containing 0, 60 μM Bovine Serum Albumin (BSA) or 10% fetal bovine serum (FBS). Before and after exposure, BAC concentrations in exposure medium were analytically determined. Based on freely dissolved concentrations at the end of the exposure, median effect concentrations (EC50) decreased with increasing alkyl chain length up to 14 carbons. For BAC with alkyl chains of twelve or more carbons, EC50s based on measured concentrations after exposure in supplement-free medium were up to 25-times lower than EC50 calculated using nominal concentrations. When BSA or FBS was added to the medium, a decrease in cytotoxic potency of up to 22 times was observed for BAC with alkyl chains of eight or more carbons. The results of this study emphasize the importance of expressing the in vitro readouts as a function of a dose metric that is least influenced by assay setup to compare assay sensitivities and chemical potencies.
- 23 April 2019
- Published by American Chemical Society (ACS) in Chemical Research in Toxicology
- Vol. 32 (6) , 1103-1114
Open AccessInfluence of in Vitro Assay Setup on the Apparent Cytotoxic Potency of Benzalkonium Chlorides
The nominal concentration is generally used to express concentration-effect relationships in in vitro toxicity assays. However, the nominal concentration does not necessarily represent the exposure concentration responsible for the observed effect. Surfactants accumulate at interphases and likely sorb to in vitro system components such as serum protein and well plate plastic. The extent of sorption and the consequences of this sorption on in vitro readouts is largely unknown for these chemicals. The aim of this study was to demonstrate the effect of sorption to in vitro components on the observed cytotoxic potency of benzalkonium chlorides (BAC) varying in alkyl chain length (6-18 carbon atoms, C6-18) in a basal cytotoxicity assay with the rainbow trout gill cell line (RTgill-W1). Cells were exposed for 48h in 96-well plates to increasing concentration of BACs in exposure medium containing 0, 60 μM Bovine Serum Albumin (BSA) or 10% fetal bovine serum (FBS). Before and after exposure, BAC concentrations in exposure medium were analytically determined. Based on freely dissolved concentrations at the end of the exposure, median effect concentrations (EC50) decreased with increasing alkyl chain length up to 14 carbons. For BAC with alkyl chains of twelve or more carbons, EC50s based on measured concentrations after exposure in supplement-free medium were up to 25-times lower than EC50 calculated using nominal concentrations. When BSA or FBS was added to the medium, a decrease in cytotoxic potency of up to 22 times was observed for BAC with alkyl chains of eight or more carbons. The results of this study emphasize the importance of expressing the in vitro readouts as a function of a dose metric that is least influenced by assay setup to compare assay sensitivities and chemical potencies.
- Open Access
- 1 March 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1002, 26-38
Evaluating solid phase (micro-) extraction tools to analyze freely ionizable and permanently charged cationic surfactants
- 1 March 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1002, 26-38
Open AccessEvaluating solid phase (micro-) extraction tools to analyze freely ionizable and permanently charged cationic surfactants
- Open Access
- 22 February 2017
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (5) , 2890-2898
Sorption of Cationic Surfactants to Artificial Cell Membranes: Comparing Phospholipid Bilayers with Monolayer Coatings and Molecular Simulations
This study reports the distribution coefficient between phospholipid bilayer membranes and PBS medium (DMW,PBS) for 19 cationic surfactants. The method used a sorbent dilution series with solid supported lipid membranes (SSLMs). The existing SSLM protocol, applying a 96 well plate set-up, was adapted to use 1.5 mL glass autosampler vials instead, which facilitated sampling and circumvented several confounding loss processes for some of the cationic surfactants. About 1% of the phospholipids were found to be detached from the SSLM beads, resulting in nonlinear sorption isotherms for compounds with logDMW values above 4. Renewal of the medium resulted in linear sorption isotherms. DMW values determined at pH 5.4 demonstrated that cationic surfactant species account for the observed DMW,PBS . LogDMW,PBS values above 5.5 are only experimentally feasible with lower LC-MS/MS detection limits and/or concentrated extracts of the aqueous samples. Based on the number of carbon atoms, dialkylamines showed a considerably lower sorption affinity than linear alkylamine analogues. These SSLM results closely overlapped with measurements on a chromatographic tool based on immobilized artificial membranes (IAM-HPLC), and with quantum-chemistry based calculations with COSMOmic. The SSLM data suggest that IAM-HPLC underestimates the DMW,PBS of ionized primary and secondary alkylamines by 0.8 and 0.5 log units, respectively.
- 22 February 2017
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 51 (5) , 2890-2898
Open AccessSorption of Cationic Surfactants to Artificial Cell Membranes: Comparing Phospholipid Bilayers with Monolayer Coatings and Molecular Simulations
This study reports the distribution coefficient between phospholipid bilayer membranes and PBS medium (DMW,PBS) for 19 cationic surfactants. The method used a sorbent dilution series with solid supported lipid membranes (SSLMs). The existing SSLM protocol, applying a 96 well plate set-up, was adapted to use 1.5 mL glass autosampler vials instead, which facilitated sampling and circumvented several confounding loss processes for some of the cationic surfactants. About 1% of the phospholipids were found to be detached from the SSLM beads, resulting in nonlinear sorption isotherms for compounds with logDMW values above 4. Renewal of the medium resulted in linear sorption isotherms. DMW values determined at pH 5.4 demonstrated that cationic surfactant species account for the observed DMW,PBS . LogDMW,PBS values above 5.5 are only experimentally feasible with lower LC-MS/MS detection limits and/or concentrated extracts of the aqueous samples. Based on the number of carbon atoms, dialkylamines showed a considerably lower sorption affinity than linear alkylamine analogues. These SSLM results closely overlapped with measurements on a chromatographic tool based on immobilized artificial membranes (IAM-HPLC), and with quantum-chemistry based calculations with COSMOmic. The SSLM data suggest that IAM-HPLC underestimates the DMW,PBS of ionized primary and secondary alkylamines by 0.8 and 0.5 log units, respectively.
- 1 May 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1447, 1-8
Sorption of structurally different ionized pharmaceutical and illicit drugs to a mixed-mode coated microsampler
- 1 May 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1447, 1-8
Sorption of structurally different ionized pharmaceutical and illicit drugs to a mixed-mode coated microsampler