Gabriel Blaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gabriel Blaj has a total of 285 co-authors. Here are the top co-authors by number of shared publications:
G. Haller
SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, U.S.A.
22 shared publicationsA. Dragone
SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, U.S.A.
19 shared publicationsJ. Segal
SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, U.S.A.
19 shared publicationsC. Kenney
18 shared publicationsA. Tomada
SLAC National Accelerator Laboratory, Menlo Park, CA, USA
17 shared publications- Pietro Caragiulo
SLAC National Accelerator Laboratory, Menlo Park, CA, USA
17 shared publications
Latest Publications
- 20 April 2026
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 11 (4)
Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index
- 20 April 2026
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 11 (4)
Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index
- Open Access
- 1 October 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1045, 167489
The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors
- 1 October 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1045, 167489
Open AccessThe Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors
- Open Access
- 1 September 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (09) , P09009
Radiation hardness study of the ePix100 sensor and ASIC under direct illumination at the European XFEL
The ePix detector family provides multiple variants of hybrid pixel detectors to support a wide range of applications at free electron laser (FEL) facilities. The ePix detectors are by design versatile and easily re-configurable camera systems with common mechanical, electrical and data acquisition interfaces. Operation of detectors at FEL sources providing high brilliance, high repetition rate and ultra-short X-ray pulses poses a high risk of radiation damage to exposed detector components, such as the sensor and the readout Application Specific Integrated Circuit (ASIC). Knowledge about radiation-induced damage is important for understanding its influence on the quality of scientific data and the lifetime of the detector. We present the results of a systematic study of the influence of radiation-induced damage on the performance and lifetime of an ePix100a detector module using a direct attenuated beam of the European X-ray Free Electron Laser Facility (European XFEL) at 9 keV photon energy and average power of 10 μW. An area of 20 pixels×20 pixels was irradiated with an average photon flux of ≈ 7× 109photons/s to a dose of approximately (760± 65) kGy at the location of the Si/SiO2interfaces in the sensor. A dose dependent increase in both offset and noise of the ePix100a detector have been observed originating from an increase of the sensor leakage current. Moreover, we observed an effect directly after irradiation resulting in the saturation of individual pixels by their dark current. Changes in gain are evaluated one and half hours post-irradiation and suggest damage to occur also on the ASIC level. Based on the obtained results, thresholds for beam parameters are deduced and the detector lifetime is estimated with respect to the requirements to the data quality in order to satisfy the scientific standards defined by the experiments. We conclude the detector can withstand a beam with an energy up to 1 μJ at a photon energy of 9 keV impacting on an area of 1 mm2. The detector can be used without significant degradation of its performance for several years if the incident photon beam intensities do not exceed the detector's dynamic range by at least three orders of magnitude. Our results provide valuable input for the operation of the ePix100a detector at FEL facilities and the design of future detector technology.
- 1 September 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (09) , P09009
Open AccessRadiation hardness study of the ePix100 sensor and ASIC under direct illumination at the European XFEL
The ePix detector family provides multiple variants of hybrid pixel detectors to support a wide range of applications at free electron laser (FEL) facilities. The ePix detectors are by design versatile and easily re-configurable camera systems with common mechanical, electrical and data acquisition interfaces. Operation of detectors at FEL sources providing high brilliance, high repetition rate and ultra-short X-ray pulses poses a high risk of radiation damage to exposed detector components, such as the sensor and the readout Application Specific Integrated Circuit (ASIC). Knowledge about radiation-induced damage is important for understanding its influence on the quality of scientific data and the lifetime of the detector. We present the results of a systematic study of the influence of radiation-induced damage on the performance and lifetime of an ePix100a detector module using a direct attenuated beam of the European X-ray Free Electron Laser Facility (European XFEL) at 9 keV photon energy and average power of 10 μW. An area of 20 pixels×20 pixels was irradiated with an average photon flux of ≈ 7× 109photons/s to a dose of approximately (760± 65) kGy at the location of the Si/SiO2interfaces in the sensor. A dose dependent increase in both offset and noise of the ePix100a detector have been observed originating from an increase of the sensor leakage current. Moreover, we observed an effect directly after irradiation resulting in the saturation of individual pixels by their dark current. Changes in gain are evaluated one and half hours post-irradiation and suggest damage to occur also on the ASIC level. Based on the obtained results, thresholds for beam parameters are deduced and the detector lifetime is estimated with respect to the requirements to the data quality in order to satisfy the scientific standards defined by the experiments. We conclude the detector can withstand a beam with an energy up to 1 μJ at a photon energy of 9 keV impacting on an area of 1 mm2. The detector can be used without significant degradation of its performance for several years if the incident photon beam intensities do not exceed the detector's dynamic range by at least three orders of magnitude. Our results provide valuable input for the operation of the ePix100a detector at FEL facilities and the design of future detector technology.
- Open Access
- 17 April 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 608-615
The ePix10k 2-megapixel hard X-ray detector at LCLS
The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel−1 pulse−1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.
- 17 April 2020
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 27 (3) , 608-615
Open AccessThe ePix10k 2-megapixel hard X-ray detector at LCLS
The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel−1 pulse−1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.
- Open Access
- 22 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (4) , 1497
The Magnitude and Waveform of Shock Waves Induced by X-ray Lasers in Water
The high energy densities deposited in materials by focused X-ray laser pulses generate shock waves which travel away from the irradiated region, and can generate complex wave patterns or induce phase changes. We determined the time-pressure histories of shocks induced by X-ray laser pulses in liquid water microdrops, by measuring the surface velocity of the microdrops from images recorded during the reflection of the shock at the surface. Measurements were made with ~30 µm diameter droplets using 10 keV X-rays, for X-ray pulse energies that deposited linear energy densities from 3.5 to 120 mJ/m; measurements were also made with ~60 µm diameter drops for a narrower energy range. At a distance of 15 µm from the X-ray beam, the peak shock pressures ranged from 44 to 472 MPa, and the corresponding time-pressure histories of the shocks had a fast quasi-exponential decay with positive pressure durations estimated to range from 2 to 5 ns. Knowledge of the amplitude and waveform of the shock waves enables accurate modeling of shock propagation and experiment designs that either maximize or minimize the effect of shocks.
- 22 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (4) , 1497
Open AccessThe Magnitude and Waveform of Shock Waves Induced by X-ray Lasers in Water
The high energy densities deposited in materials by focused X-ray laser pulses generate shock waves which travel away from the irradiated region, and can generate complex wave patterns or induce phase changes. We determined the time-pressure histories of shocks induced by X-ray laser pulses in liquid water microdrops, by measuring the surface velocity of the microdrops from images recorded during the reflection of the shock at the surface. Measurements were made with ~30 µm diameter droplets using 10 keV X-rays, for X-ray pulse energies that deposited linear energy densities from 3.5 to 120 mJ/m; measurements were also made with ~60 µm diameter drops for a narrower energy range. At a distance of 15 µm from the X-ray beam, the peak shock pressures ranged from 44 to 472 MPa, and the corresponding time-pressure histories of the shocks had a fast quasi-exponential decay with positive pressure durations estimated to range from 2 to 5 ns. Knowledge of the amplitude and waveform of the shock waves enables accurate modeling of shock propagation and experiment designs that either maximize or minimize the effect of shocks.
- 5 August 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (5) , 1621-1630
Dead-time correction for spectroscopic photon-counting pixel detectors
Modern photon-counting pixel detectors have enabled a revolution in applications at synchrotron light sources and beyond in the last decade. One of the limitations of the current detectors is their reduced counting linearity or even paralysis at high counting rates, due to dead-time which results in photon pile-up. Existing dead-time and pile-up models fail to reproduce the complexity of dead-time effects on photon-counting, resulting in empirical calibrations for particular detectors at best, imprecise linearization methods, or no linearization. This problem will increase in the future as many synchrotron light sources plan significant brilliance upgrades and free-electron lasers plan moving to a quasi-continuous operation mode. Presented here are the first models that use the actual behavior of the analog pre-amplifiers in spectroscopic photon-counting pixel detectors with constant current discharge (e.g. the Medipix and CPix families of detectors) to deduce more accurate analytical models and optimal linearization methods. In particular, for detectors with at least two counters per pixel, the need for calibration, or previous knowledge of the detector and beam parameters (dead-time, integration time, large sets of synchrotron filling patterns), is completely eliminated. This is summarized in several models of increasing complexity and accuracy. Finally, a general empirical approach is presented, applicable to any particular cases where the analytical approach is not sufficiently precise.
- 5 August 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (5) , 1621-1630
Dead-time correction for spectroscopic photon-counting pixel detectors
Modern photon-counting pixel detectors have enabled a revolution in applications at synchrotron light sources and beyond in the last decade. One of the limitations of the current detectors is their reduced counting linearity or even paralysis at high counting rates, due to dead-time which results in photon pile-up. Existing dead-time and pile-up models fail to reproduce the complexity of dead-time effects on photon-counting, resulting in empirical calibrations for particular detectors at best, imprecise linearization methods, or no linearization. This problem will increase in the future as many synchrotron light sources plan significant brilliance upgrades and free-electron lasers plan moving to a quasi-continuous operation mode. Presented here are the first models that use the actual behavior of the analog pre-amplifiers in spectroscopic photon-counting pixel detectors with constant current discharge (e.g. the Medipix and CPix families of detectors) to deduce more accurate analytical models and optimal linearization methods. In particular, for detectors with at least two counters per pixel, the need for calibration, or previous knowledge of the detector and beam parameters (dead-time, integration time, large sets of synchrotron filling patterns), is completely eliminated. This is summarized in several models of increasing complexity and accuracy. Finally, a general empirical approach is presented, applicable to any particular cases where the analytical approach is not sufficiently precise.
- Open Access
- 10 April 2019
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 4 (4) , 043401
Generation of high-intensity ultrasound through shock propagation in liquid jets
We investigated the generation and propagation of ultrasonic pressure waves produced by focused x-ray free-electron laser pulses in 14 to diameter liquid water microjets. The pressure waves formed through reflections, at the surface of the microjets, of the initial shock launched in the liquid by the x-ray pulse. These waves developed a characteristic geometric pattern which is related to, but different from, the shock structures of supersonic gas jets. Fully developed waves had initial peak pressures ranging from less than –24 MPa to approximately 100 MPa, which exceed the compressive and tensile strengths of many materials, and correspond to extreme sound intensities on the order of and sound pressure levels above 270 dB (re: ). The amplitudes and intensities were limited by the wave destroying its own propagation medium though cavitation, and therefore these ultrasonic waves in jets are one of the most intense propagating sounds that can be generated in liquid water. The pressure of the initial shock decayed exponentially, more rapidly in thinner jets, and the decay length was proportional to the jet diameter within the accuracy of measurements. Extrapolating our results to thinner jets, we find that the pressure waves may damage protein crystals carried by liquid jets in x-ray laser crystallography experiments conducted at megahertz repetition rates.- 10 April 2019
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 4 (4) , 043401
Open AccessGeneration of high-intensity ultrasound through shock propagation in liquid jets
We investigated the generation and propagation of ultrasonic pressure waves produced by focused x-ray free-electron laser pulses in 14 to diameter liquid water microjets. The pressure waves formed through reflections, at the surface of the microjets, of the initial shock launched in the liquid by the x-ray pulse. These waves developed a characteristic geometric pattern which is related to, but different from, the shock structures of supersonic gas jets. Fully developed waves had initial peak pressures ranging from less than –24 MPa to approximately 100 MPa, which exceed the compressive and tensile strengths of many materials, and correspond to extreme sound intensities on the order of and sound pressure levels above 270 dB (re: ). The amplitudes and intensities were limited by the wave destroying its own propagation medium though cavitation, and therefore these ultrasonic waves in jets are one of the most intense propagating sounds that can be generated in liquid water. The pressure of the initial shock decayed exponentially, more rapidly in thinner jets, and the decay length was proportional to the jet diameter within the accuracy of measurements. Extrapolating our results to thinner jets, we find that the pressure waves may damage protein crystals carried by liquid jets in x-ray laser crystallography experiments conducted at megahertz repetition rates. - 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060077
Ultrafast processing of pixel detector data with machine learning frameworks
Modern photon science performed at high repetition rate free-electron laser (FEL) facilities and beyond relies on 2D pixel detectors operating at increasing frequencies (towards 100 kHz at LCLS-II) and producing rapidly increasing amounts of data (towards TB/s). This data must be rapidly stored for offline analysis and summarized in real time for online feedback to the scientists. While at LCLS all raw data has been stored, at LCLS-II this would lead to a prohibitive cost; instead, enabling real time processing of pixel detector data (dark, gain, common mode, background, charge summing, subpixel position, photon counting, data summarization) allows reducing the size and cost of online processing, offline processing and storage by orders of magnitude while preserving full photon information. This could be achieved by taking advantage of the compressibility of sparse data typical for LCLS-II applications. Faced with a similar big data challenge a decade ago, computer vision stimulated revolutionary advances in machine learning hardware and software. We investigated if these developments are useful in the field of data processing for high speed pixel detectors and found that typical deep learning models and autoencoder architectures failed to yield useful noise reduction while preserving full photon information, presumably because of the very different statistics and feature sets in computer vision and radiation imaging. However, the raw performance of modern frameworks like Tensorflow inspired us to redesign in Tensorflow mathematically equivalent versions of the state-of-the-art, “classical” algorithms used at LCLS. The novel Tensorflow models resulted in elegant, compact and hardware agnostic code, gaining 1 to 2 orders of magnitude faster processing on an inexpensive consumer GPU, reducing by 3 orders of magnitude the projected cost of online analysis and compression without photon loss at LCLS-II. The novel Tensorflow models also enabled ongoing development of a pipelined hardware system expected to yield an additional 3 to 4 orders of magnitude speedup, necessary for meeting the data acquisition and storage requirements at LCLS-II, potentially enabling acquiring every single FEL pulse at full speed. Computer vision a decade ago was dominated by hand-crafted filters; their structure inspired the deep learning revolution resulting in modern deep convolutional networks; similarly, our novel Tensorflow filters provide inspiration for designing future deep learning models for ultrafast and efficient processing and classification of pixel detector images at FEL facilities.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060077
Ultrafast processing of pixel detector data with machine learning frameworks
Modern photon science performed at high repetition rate free-electron laser (FEL) facilities and beyond relies on 2D pixel detectors operating at increasing frequencies (towards 100 kHz at LCLS-II) and producing rapidly increasing amounts of data (towards TB/s). This data must be rapidly stored for offline analysis and summarized in real time for online feedback to the scientists. While at LCLS all raw data has been stored, at LCLS-II this would lead to a prohibitive cost; instead, enabling real time processing of pixel detector data (dark, gain, common mode, background, charge summing, subpixel position, photon counting, data summarization) allows reducing the size and cost of online processing, offline processing and storage by orders of magnitude while preserving full photon information. This could be achieved by taking advantage of the compressibility of sparse data typical for LCLS-II applications. Faced with a similar big data challenge a decade ago, computer vision stimulated revolutionary advances in machine learning hardware and software. We investigated if these developments are useful in the field of data processing for high speed pixel detectors and found that typical deep learning models and autoencoder architectures failed to yield useful noise reduction while preserving full photon information, presumably because of the very different statistics and feature sets in computer vision and radiation imaging. However, the raw performance of modern frameworks like Tensorflow inspired us to redesign in Tensorflow mathematically equivalent versions of the state-of-the-art, “classical” algorithms used at LCLS. The novel Tensorflow models resulted in elegant, compact and hardware agnostic code, gaining 1 to 2 orders of magnitude faster processing on an inexpensive consumer GPU, reducing by 3 orders of magnitude the projected cost of online analysis and compression without photon loss at LCLS-II. The novel Tensorflow models also enabled ongoing development of a pipelined hardware system expected to yield an additional 3 to 4 orders of magnitude speedup, necessary for meeting the data acquisition and storage requirements at LCLS-II, potentially enabling acquiring every single FEL pulse at full speed. Computer vision a decade ago was dominated by hand-crafted filters; their structure inspired the deep learning revolution resulting in modern deep convolutional networks; similarly, our novel Tensorflow filters provide inspiration for designing future deep learning models for ultrafast and efficient processing and classification of pixel detector images at FEL facilities.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060062
Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs
EPix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e− equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.
- 16 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054 (1) , 060062
Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs
EPix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e− equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.
- 1 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054, 060037
Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers
- 1 January 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2054, 060037
Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers