Milan Biswal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Milan Biswal has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Huiping Cao
Computer Science Department at New Mexico State Univesity, Las Cruces, NM, 88003, USA
4 shared publicationsSukumar Brahma
Klipsch School of Electrical and Computer Engineering, USA
4 shared publications- Birendra Biswal
Gayatri Vidya Parishad College of Engineering (A)
3 shared publications P. K. Dash
SOA University, Bhubaneswar, India
3 shared publicationsP.K. Dash
3 shared publications- Srikanta K. Mishra
Department of Special Education and Communication Disorders, New Mexico State University, Las Cruces, NM, USA
3 shared publications
Latest Publications
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2507-2516
Evaluating the Use of Shapelets in Traveling Wave Based Fault Detection and Classification in Distribution Systems
The application of traveling wave (TW) principles for fault detection in distribution systems is challenging because of multiple reflections from the laterals and other lumped elements, particularly when we consider communication-free applications. In [1], we proposed the use of Shapelets to characterize fault signatures as we move towards a more realistic data-driven solution. The Shapelet can be correlated with the physical characteristics of TW generation process, in contrast to choosing a predefined basis such as Wavelets. This paper is an extension of this work to comprehensively evaluate Shapelets for identifying the fault types, in addition to their locations in single-phase, three-phase, and IEEE 13-bus distribution systems. We also propose using the voltage waveforms instead of the forward waves, which eliminates the need for a CT. The proposed method can identify fault locations within a local region with ≈ 99% accuracy and classify the fault types with an accuracy of over 90%.
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2507-2516
Evaluating the Use of Shapelets in Traveling Wave Based Fault Detection and Classification in Distribution Systems
The application of traveling wave (TW) principles for fault detection in distribution systems is challenging because of multiple reflections from the laterals and other lumped elements, particularly when we consider communication-free applications. In [1], we proposed the use of Shapelets to characterize fault signatures as we move towards a more realistic data-driven solution. The Shapelet can be correlated with the physical characteristics of TW generation process, in contrast to choosing a predefined basis such as Wavelets. This paper is an extension of this work to comprehensively evaluate Shapelets for identifying the fault types, in addition to their locations in single-phase, three-phase, and IEEE 13-bus distribution systems. We also propose using the voltage waveforms instead of the forward waves, which eliminates the need for a CT. The proposed method can identify fault locations within a local region with ≈ 99% accuracy and classify the fault types with an accuracy of over 90%.
- Open Access
- 15 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2682-2691
Detection and Prevention of Unintentional Formation of Loops in Self-Healing Power Systems and Microgrids
Self-healing or self-assembling power systems that rely on local measurements for decision making can provide significant resilience benefits, but they also must include safeguards that prevent the system from self-assembling into an undesirable configuration. One potential undesirable configuration would be the formation of closed loops for which the system was not designed, a situation that can arise any time that two intentional-island systems can be connected in more than one place, e.g. if tie-line breakers are included in the self-assembling system. This paper discusses the unintentional loop formation problem in self-assembling systems and presents a method for mitigating it. This method involves calculating the correlation or the mean absolute error (MAE) between the two local frequency measurements made on either side of a line relay. The correlation and MAE between these frequencies changes significantly between the loop and non-loop cases, and this difference can be used for loop detection. This paper presents and explains the method in detail, presents evidence that the method's underlying assumptions are valid, and demonstrates in PSCAD two implementations of the method. The paper concludes with a discussion of the strengths and weaknesses of the proposed method.
- 15 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2682-2691
Open AccessDetection and Prevention of Unintentional Formation of Loops in Self-Healing Power Systems and Microgrids
Self-healing or self-assembling power systems that rely on local measurements for decision making can provide significant resilience benefits, but they also must include safeguards that prevent the system from self-assembling into an undesirable configuration. One potential undesirable configuration would be the formation of closed loops for which the system was not designed, a situation that can arise any time that two intentional-island systems can be connected in more than one place, e.g. if tie-line breakers are included in the self-assembling system. This paper discusses the unintentional loop formation problem in self-assembling systems and presents a method for mitigating it. This method involves calculating the correlation or the mean absolute error (MAE) between the two local frequency measurements made on either side of a line relay. The correlation and MAE between these frequencies changes significantly between the loop and non-loop cases, and this difference can be used for loop detection. This paper presents and explains the method in detail, presents evidence that the method's underlying assumptions are valid, and demonstrates in PSCAD two implementations of the method. The paper concludes with a discussion of the strengths and weaknesses of the proposed method.
- Open Access
- 1 February 2022
- Published by Office of Scientific and Technical Information (OSTI)
Exploring the use of Shapelets in Traveling Wave based Fault Detection in Distribution Systems.
- 1 February 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessExploring the use of Shapelets in Traveling Wave based Fault Detection in Distribution Systems.
- Open Access
AMI-FML: A Privacy-Preserving Federated Machine Learning Framework for AMI
Machine learning (ML) based smart meter data analytics is very promising for energy management and demand-response applications in the advanced metering infrastructure(AMI). A key challenge in developing distributed ML applications for AMI is to preserve user privacy while allowing active end-users participation. This paper addresses this challenge and proposes a privacy-preserving federated learning framework for ML applications in the AMI. We consider each smart meter as a federated edge device hosting an ML application that exchanges information with a central aggregator or a data concentrator, periodically. Instead of transferring the raw data sensed by the smart meters, the ML model weights are transferred to the aggregator to preserve privacy. The aggregator processes these parameters to devise a robust ML model that can be substituted at each edge device. We also discuss strategies to enhance privacy and improve communication efficiency while sharing the ML model parameters, suited for relatively slow network connections in the AMI. We demonstrate the proposed framework on a use case federated ML (FML) application that improves short-term load forecasting (STLF). We use a long short-term memory(LSTM) recurrent neural network (RNN) model for STLF. In our architecture, we assume that there is an aggregator connected to a group of smart meters. The aggregator uses the learned model gradients received from the federated smart meters to generate an aggregate, robust RNN model which improves the forecasting accuracy for individual and aggregated STLF. Our results indicate that with FML, forecasting accuracy is increased while preserving the data privacy of the end-users.
Open AccessAMI-FML: A Privacy-Preserving Federated Machine Learning Framework for AMI
Machine learning (ML) based smart meter data analytics is very promising for energy management and demand-response applications in the advanced metering infrastructure(AMI). A key challenge in developing distributed ML applications for AMI is to preserve user privacy while allowing active end-users participation. This paper addresses this challenge and proposes a privacy-preserving federated learning framework for ML applications in the AMI. We consider each smart meter as a federated edge device hosting an ML application that exchanges information with a central aggregator or a data concentrator, periodically. Instead of transferring the raw data sensed by the smart meters, the ML model weights are transferred to the aggregator to preserve privacy. The aggregator processes these parameters to devise a robust ML model that can be substituted at each edge device. We also discuss strategies to enhance privacy and improve communication efficiency while sharing the ML model parameters, suited for relatively slow network connections in the AMI. We demonstrate the proposed framework on a use case federated ML (FML) application that improves short-term load forecasting (STLF). We use a long short-term memory(LSTM) recurrent neural network (RNN) model for STLF. In our architecture, we assume that there is an aggregator connected to a group of smart meters. The aggregator uses the learned model gradients received from the federated smart meters to generate an aggregate, robust RNN model which improves the forecasting accuracy for individual and aggregated STLF. Our results indicate that with FML, forecasting accuracy is increased while preserving the data privacy of the end-users.
- 1 February 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (2) , 640-644
Efferent-induced alterations in distortion and reflection otoacoustic emissions in children
The medial olivocochlear efferent fibers control outer hair cell responses and inhibit the cochlear-amplifier gain. Measuring efferent function is both theoretically and clinically relevant. In humans, medial efferent inhibition can be assayed via otoacoustic emissions (OAEs). OAEs arise by two fundamentally different mechanisms—nonlinear distortion and coherent reflection. Distortion and reflection emissions are typically applied in isolation for studying the efferent inhibition. Such an approach inadvertently assumes that efferent-induced shifts in distortion and reflection emissions provide redundant information. In this study, efferent-induced shifts in distortion and reflection emissions (click-evoked and stimulus frequency OAEs) were measured in the same subjects—5- to 10-yr-old children. Consistent with the OAE generation theory, efferent-induced shifts in distortion and reflection emissions did not correlate, whereas the two reflection emission shifts correlated. This suggests that using either OAE types provides fragmented information on efferent inhibition and highlights the need to use both distortion and reflection emissions for describing efferent effects.
- 1 February 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (2) , 640-644
Efferent-induced alterations in distortion and reflection otoacoustic emissions in children
The medial olivocochlear efferent fibers control outer hair cell responses and inhibit the cochlear-amplifier gain. Measuring efferent function is both theoretically and clinically relevant. In humans, medial efferent inhibition can be assayed via otoacoustic emissions (OAEs). OAEs arise by two fundamentally different mechanisms—nonlinear distortion and coherent reflection. Distortion and reflection emissions are typically applied in isolation for studying the efferent inhibition. Such an approach inadvertently assumes that efferent-induced shifts in distortion and reflection emissions provide redundant information. In this study, efferent-induced shifts in distortion and reflection emissions (click-evoked and stimulus frequency OAEs) were measured in the same subjects—5- to 10-yr-old children. Consistent with the OAE generation theory, efferent-induced shifts in distortion and reflection emissions did not correlate, whereas the two reflection emission shifts correlated. This suggests that using either OAE types provides fragmented information on efferent inhibition and highlights the need to use both distortion and reflection emissions for describing efferent effects.
- 1 February 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (2) , 626-639
Comparison of time-frequency methods for analyzing stimulus frequency otoacoustic emissions
Stimulus frequency otoacoustic emissions (SFOAEs) can have multiple time varying components, including multiple internal reflections. It is, therefore, necessary to study SFOAEs using techniques that can represent their time-frequency behavior. Although various time-frequency schemes can be applied to identify and filter SFOAE components, their accuracy for SFOAE analysis has not been investigated. The relative performance of these methods is important for accurate characterization of SFOAEs that may, in turn, enhance the understanding of SFOAE generation. This study using in silico experiments examined the performance of three linear (short-time Fourier transform, continuous wavelet transform, Stockwell transform) and two nonlinear (empirical mode decomposition and synchrosqueezed wavelet transform) time-frequency approaches for SFOAE analysis. Their performances in terms of phase-gradient delay estimation, frequency specificity, and spectral component extraction are compared, and the relative merits and limitations of each method are discussed. Overall, this paper provides a comparative analysis of various time-frequency methods useful for otoacoustic emission applications.
- 1 February 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 143 (2) , 626-639
Comparison of time-frequency methods for analyzing stimulus frequency otoacoustic emissions
Stimulus frequency otoacoustic emissions (SFOAEs) can have multiple time varying components, including multiple internal reflections. It is, therefore, necessary to study SFOAEs using techniques that can represent their time-frequency behavior. Although various time-frequency schemes can be applied to identify and filter SFOAE components, their accuracy for SFOAE analysis has not been investigated. The relative performance of these methods is important for accurate characterization of SFOAEs that may, in turn, enhance the understanding of SFOAE generation. This study using in silico experiments examined the performance of three linear (short-time Fourier transform, continuous wavelet transform, Stockwell transform) and two nonlinear (empirical mode decomposition and synchrosqueezed wavelet transform) time-frequency approaches for SFOAE analysis. Their performances in terms of phase-gradient delay estimation, frequency specificity, and spectral component extraction are compared, and the relative merits and limitations of each method are discussed. Overall, this paper provides a comparative analysis of various time-frequency methods useful for otoacoustic emission applications.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 170003
On reliable time-frequency characterization and delay estimation of stimulus frequency otoacoustic emissions
The limited information on origin and nature of stimulus frequency otoacoustic emissions (SFOAEs) necessitates a thorough reexamination into SFOAE analysis procedures. This will lead to a better understanding of the generation of SFOAEs. The SFOAE response waveform in the time domain can be interpreted as a summation of amplitude modulated and frequency modulated component waveforms. The efficiency of a technique to segregate these components is critical to describe the nature of SFOAEs. Recent advancements in robust time-frequency analysis algorithms have staked claims on the more accurate extraction of these components, from composite signals buried in noise. However, their potential has not been fully explored for SFOAEs analysis. Indifference to distinct information, due to nature of these analysis techniques, may impact the scientific conclusions. This paper attempts to bridge this gap in literature by evaluating the performance of three linear time-frequency analysis algorithms: short-time Fourier transform (STFT), continuous Wavelet transform (CWT), S-transform (ST) and two nonlinear algorithms: Hilbert-Huang Transform (HHT), synchrosqueezed Wavelet transform (SWT). We revisit the extraction of constituent components and estimation of their magnitude and delay, by carefully evaluating the impact of variation in analysis parameters. The performance of HHT and SWT from the perspective of time-frequency filtering and delay estimation were found to be relatively less efficient for analyzing SFOAEs. The intrinsic mode functions of HHT does not completely characterize the reflection components and hence IMF based filtering alone, is not recommended for segregating principal emission from multiple reflection components. We found STFT, WT, and ST to be suitable for canceling multiple internal reflection components with marginal altering in SFOAE.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 170003
On reliable time-frequency characterization and delay estimation of stimulus frequency otoacoustic emissions
The limited information on origin and nature of stimulus frequency otoacoustic emissions (SFOAEs) necessitates a thorough reexamination into SFOAE analysis procedures. This will lead to a better understanding of the generation of SFOAEs. The SFOAE response waveform in the time domain can be interpreted as a summation of amplitude modulated and frequency modulated component waveforms. The efficiency of a technique to segregate these components is critical to describe the nature of SFOAEs. Recent advancements in robust time-frequency analysis algorithms have staked claims on the more accurate extraction of these components, from composite signals buried in noise. However, their potential has not been fully explored for SFOAEs analysis. Indifference to distinct information, due to nature of these analysis techniques, may impact the scientific conclusions. This paper attempts to bridge this gap in literature by evaluating the performance of three linear time-frequency analysis algorithms: short-time Fourier transform (STFT), continuous Wavelet transform (CWT), S-transform (ST) and two nonlinear algorithms: Hilbert-Huang Transform (HHT), synchrosqueezed Wavelet transform (SWT). We revisit the extraction of constituent components and estimation of their magnitude and delay, by carefully evaluating the impact of variation in analysis parameters. The performance of HHT and SWT from the perspective of time-frequency filtering and delay estimation were found to be relatively less efficient for analyzing SFOAEs. The intrinsic mode functions of HHT does not completely characterize the reflection components and hence IMF based filtering alone, is not recommended for segregating principal emission from multiple reflection components. We found STFT, WT, and ST to be suitable for canceling multiple internal reflection components with marginal altering in SFOAE.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Detection of fault using local measurements at inverter interfaced distributed energy resources
High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid results in failure of the traditional overcurrent based fault detection at the point of interconnection (POI) of IIDERs. This paper focuses on other strategies of detection, namely, 1) using the transient content at the inverter output, 2) using zero sequence current magnitude at the high side of interconnecting transformer, and 3) using voltage drop at the POI. These strategies are tested by simulating a 100 kW three-phase Voltage-sourced Inverter connected to the IEEE 13-node distribution feeder in PSCAD environment. Performance of the selected strategies to various faults in the system is documented and evaluated.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Detection of fault using local measurements at inverter interfaced distributed energy resources
High proliferation of Inverter Interfaced Distributed Energy Resources (IIDERs) into the electric distribution grid results in failure of the traditional overcurrent based fault detection at the point of interconnection (POI) of IIDERs. This paper focuses on other strategies of detection, namely, 1) using the transient content at the inverter output, 2) using zero sequence current magnitude at the high side of interconnecting transformer, and 3) using voltage drop at the POI. These strategies are tested by simulating a 100 kW three-phase Voltage-sourced Inverter connected to the IEEE 13-node distribution feeder in PSCAD environment. Performance of the selected strategies to various faults in the system is documented and evaluated.
- Top Cited Papers
- 14 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Characterizing and quantifying noise in PMU data
Data recorded by Phasor Measurement Units (PMUs) contains noise. This paper characterizes and quantifies this noise for voltage, current and frequency data recorded at three different voltage levels. The probability distribution of the measurement noise and its typical power are identified. The PMU noise quantification can help in generation of experimental PMU data in close conformity with field PMU data, bad data removal, missing data prediction, and effective design of statistical filters for noise rejection.
- 14 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Top Cited PapersCharacterizing and quantifying noise in PMU data
Data recorded by Phasor Measurement Units (PMUs) contains noise. This paper characterizes and quantifies this noise for voltage, current and frequency data recorded at three different voltage levels. The probability distribution of the measurement noise and its typical power are identified. The PMU noise quantification can help in generation of experimental PMU data in close conformity with field PMU data, bad data removal, missing data prediction, and effective design of statistical filters for noise rejection.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 23, 417-422
iCenS: An information-centric smart grid network architecture
Smart grid technologies will equip the electrical grid of the future with two-way information flow between grid entities and consumers. This bidirectional information flow facilitates improved grid monitoring, control automation, energy efficiency, and sustainability. Several smart grid networking architectures have been proposed recently. However, the majority of these are restricted to subdomains such as home area networks or substation networks, or are not scalable. There is a need for an overarching and inclusive communication architecture which accounts for all smart grid communication scenarios. In this paper, we propose iCenS, a holistic smart grid networking architecture. We identify various communication scenarios, elaborate on the suitability of iCenS, and discuss how it can be used to solve smart grid networking challenges. We also present simulation results demonstrating the scalability of our design and its effectiveness in serving various types of smart grid traffic.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 23, 417-422
iCenS: An information-centric smart grid network architecture
Smart grid technologies will equip the electrical grid of the future with two-way information flow between grid entities and consumers. This bidirectional information flow facilitates improved grid monitoring, control automation, energy efficiency, and sustainability. Several smart grid networking architectures have been proposed recently. However, the majority of these are restricted to subdomains such as home area networks or substation networks, or are not scalable. There is a need for an overarching and inclusive communication architecture which accounts for all smart grid communication scenarios. In this paper, we propose iCenS, a holistic smart grid networking architecture. We identify various communication scenarios, elaborate on the suitability of iCenS, and discuss how it can be used to solve smart grid networking challenges. We also present simulation results demonstrating the scalability of our design and its effectiveness in serving various types of smart grid traffic.