Hanmin Jang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Hanmin Jang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Dong Rip Kim
School of Mechanical Engineering Hanyang University Seoul Republic of Korea
8 shared publications - Chi Hwan Lee
School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
5 shared publications Bongjoong Kim
School of Mechanical Engineering, Purdue University, West Lafayette, USA
3 shared publications- Heung Soo Lee
Korea Atomic Energy Research Institute
3 shared publications Yale Jeon
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, USA
3 shared publications- Abigail Cox
Department of Comparative Pathobiology, Purdue University, West Lafayette, USA
2 shared publications
Latest Publications
- Open Access
- 17 June 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-14
Rapid custom prototyping of soft poroelastic biosensor for simultaneous epicardial recording and imaging
The growing need for the implementation of stretchable biosensors in the body has driven rapid prototyping schemes through the direct ink writing of multidimensional functional architectures. Recent approaches employ biocompatible inks that are dispensable through an automated nozzle injection system. However, their application in medical practices remains challenged in reliable recording due to their viscoelastic nature that yields mechanical and electrical hysteresis under periodic large strains. Herein, we report sponge-like poroelastic silicone composites adaptable for high-precision direct writing of custom-designed stretchable biosensors, which are soft and insensitive to strains. Their unique structural properties yield a robust coupling to living tissues, enabling high-fidelity recording of spatiotemporal electrophysiological activity and real-time ultrasound imaging for visual feedback. In vivo evaluations of custom-fit biosensors in a murine acute myocardial infarction model demonstrate a potential clinical utility in the simultaneous intraoperative recording and imaging on the epicardium, which may guide definitive surgical treatments.
- 17 June 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-14
Open AccessRapid custom prototyping of soft poroelastic biosensor for simultaneous epicardial recording and imaging
The growing need for the implementation of stretchable biosensors in the body has driven rapid prototyping schemes through the direct ink writing of multidimensional functional architectures. Recent approaches employ biocompatible inks that are dispensable through an automated nozzle injection system. However, their application in medical practices remains challenged in reliable recording due to their viscoelastic nature that yields mechanical and electrical hysteresis under periodic large strains. Herein, we report sponge-like poroelastic silicone composites adaptable for high-precision direct writing of custom-designed stretchable biosensors, which are soft and insensitive to strains. Their unique structural properties yield a robust coupling to living tissues, enabling high-fidelity recording of spatiotemporal electrophysiological activity and real-time ultrasound imaging for visual feedback. In vivo evaluations of custom-fit biosensors in a murine acute myocardial infarction model demonstrate a potential clinical utility in the simultaneous intraoperative recording and imaging on the epicardium, which may guide definitive surgical treatments.
- 15 March 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (11) , 13684-13692
Controlled Integration of Interconnected Pores under Polymeric Surfaces for Low Adhesion and Antiscaling Performance
Low-adhesive surfaces have been highlighted due to the potentials to mitigate fouling issues by preventing unwanted substances from adhering. Realizing superhydrophobicity with 3D surface structures/chemical modifiers or fabricating lubricant-assisted slippery surfaces has been demonstrated to realize low-adhesive surfaces. However, they still need to overcome the transition to Wenzel from Cassie states of droplets on 3D surface structures or the lubricant depletion issues of slippery surfaces for sustainable operations. Herein, we report the fabrication of low-adhesive polymeric surfaces, neither assisted by 3D surface structures/chemical modifiers nor lubricants, which is realized by embedding the interconnected pore networks underneath the top smooth surface using a water steaming method. The fabricated silicone surfaces exhibit low-adhesive properties due to the stress concentration effects generated by the subsurface-structured pores, favorable for easy detachment of the adherent from the surface. Our platform can be exploited to lower adhesion of superhydrophilic surfaces or to achieve ultralow-adhesive properties upon combination with superhydrophobicity. Finally, scale precipitation tests reveal 4.2 times lower scale accumulation of our low-adhesive polymeric surfaces than that in control samples.
- 15 March 2021
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 13 (11) , 13684-13692
Controlled Integration of Interconnected Pores under Polymeric Surfaces for Low Adhesion and Antiscaling Performance
Low-adhesive surfaces have been highlighted due to the potentials to mitigate fouling issues by preventing unwanted substances from adhering. Realizing superhydrophobicity with 3D surface structures/chemical modifiers or fabricating lubricant-assisted slippery surfaces has been demonstrated to realize low-adhesive surfaces. However, they still need to overcome the transition to Wenzel from Cassie states of droplets on 3D surface structures or the lubricant depletion issues of slippery surfaces for sustainable operations. Herein, we report the fabrication of low-adhesive polymeric surfaces, neither assisted by 3D surface structures/chemical modifiers nor lubricants, which is realized by embedding the interconnected pore networks underneath the top smooth surface using a water steaming method. The fabricated silicone surfaces exhibit low-adhesive properties due to the stress concentration effects generated by the subsurface-structured pores, favorable for easy detachment of the adherent from the surface. Our platform can be exploited to lower adhesion of superhydrophilic surfaces or to achieve ultralow-adhesive properties upon combination with superhydrophobicity. Finally, scale precipitation tests reveal 4.2 times lower scale accumulation of our low-adhesive polymeric surfaces than that in control samples.
- Open Access
- 15 October 2020
- Published by Springer Nature in Research Square
Rapid Custom Prototyping of Soft Poroelastic Biosensor for Simultaneous Epicardial Recording and Imaging
The growing need for the implementation of stretchable biosensors in the human body and organ systems has driven a new rapid prototyping scheme through the direct ink writing (DIW) of multidimensional functional architectures in an arbitrary shape and size to meet the requirement of adapting the geometric nonlinearity of a specific biological site. Recent approaches involve the use of biocompatible viscoelastic inks that are dispensable through an automated nozzle injection system. However, their pragmatic application remains challenged in particular medical practices that demand long-term reliable recording under periodic large strain cycles, such as the cardiac cycle, due to their viscoelastic nature that produces both mechanical and electrical hysteresis. Herein, we report a new class of a poroelastic silicone composite that is adaptable for high-precision DIW of a custom-designed biosensor, which is exceptionally soft and insensitive to mechanical strain without generating significant hysteresis. The unique structural property of the composite material yields a robust and seamless coupling to living tissues, thereby enabling both high-fidelity recording of spatiotemporal electrophysiological activity and real-time ultrasound imaging for visual feedback. In vivo evaluation of a custom-fit biosensor in a murine acute myocardial infarction model demonstrates a potential clinical utility in the simultaneous intraoperative recording and imaging on the epicardial surface, which may guide a definitive surgical treatment.
- 15 October 2020
- Published by Springer Nature in Research Square
Open AccessRapid Custom Prototyping of Soft Poroelastic Biosensor for Simultaneous Epicardial Recording and Imaging
The growing need for the implementation of stretchable biosensors in the human body and organ systems has driven a new rapid prototyping scheme through the direct ink writing (DIW) of multidimensional functional architectures in an arbitrary shape and size to meet the requirement of adapting the geometric nonlinearity of a specific biological site. Recent approaches involve the use of biocompatible viscoelastic inks that are dispensable through an automated nozzle injection system. However, their pragmatic application remains challenged in particular medical practices that demand long-term reliable recording under periodic large strain cycles, such as the cardiac cycle, due to their viscoelastic nature that produces both mechanical and electrical hysteresis. Herein, we report a new class of a poroelastic silicone composite that is adaptable for high-precision DIW of a custom-designed biosensor, which is exceptionally soft and insensitive to mechanical strain without generating significant hysteresis. The unique structural property of the composite material yields a robust and seamless coupling to living tissues, thereby enabling both high-fidelity recording of spatiotemporal electrophysiological activity and real-time ultrasound imaging for visual feedback. In vivo evaluation of a custom-fit biosensor in a murine acute myocardial infarction model demonstrates a potential clinical utility in the simultaneous intraoperative recording and imaging on the epicardial surface, which may guide a definitive surgical treatment.
- 13 May 2020
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 14 (6) , 7227-7236
Bioresorbable, Miniaturized Porous Silicon Needles on a Flexible Water-Soluble Backing for Unobtrusive, Sustained Delivery of Chemotherapy
Conventional melanoma therapies suffer from the toxicity and side effects of repeated treatments due to the aggressive and recurrent nature of melanoma cells. Less-invasive topical chemotherapies by utilizing polymeric microneedles have emerged as an alternative, but the sustained, long-lasting release of drug cargos remains challenging. In addition, the size of the microneedles is relatively bulky for the small, curvilinear, and exceptionally sensitive cornea for the treatment of ocular melanoma. Here, we report a design of bioresorbable, miniaturized porous-silicon (p-Si) needles with covalently linked drug cargos at doses comparable to those of conventional polymeric microneedles. The p-Si needles are built on a water-soluble film as a temporary flexible holder that can be intimately interfaced with the irregular surface of living tissues, followed by complete dissolution with saline solution within 1 min. Consequently, the p-Si needles remain embedded inside tissues and then undergo gradual degradation, allowing for sustained release of the drug cargos. Its utility in unobtrusive topical delivery of chemotherapy with minimal side effects is demonstrated in a murine melanoma model.
- 13 May 2020
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 14 (6) , 7227-7236
Bioresorbable, Miniaturized Porous Silicon Needles on a Flexible Water-Soluble Backing for Unobtrusive, Sustained Delivery of Chemotherapy
Conventional melanoma therapies suffer from the toxicity and side effects of repeated treatments due to the aggressive and recurrent nature of melanoma cells. Less-invasive topical chemotherapies by utilizing polymeric microneedles have emerged as an alternative, but the sustained, long-lasting release of drug cargos remains challenging. In addition, the size of the microneedles is relatively bulky for the small, curvilinear, and exceptionally sensitive cornea for the treatment of ocular melanoma. Here, we report a design of bioresorbable, miniaturized porous-silicon (p-Si) needles with covalently linked drug cargos at doses comparable to those of conventional polymeric microneedles. The p-Si needles are built on a water-soluble film as a temporary flexible holder that can be intimately interfaced with the irregular surface of living tissues, followed by complete dissolution with saline solution within 1 min. Consequently, the p-Si needles remain embedded inside tissues and then undergo gradual degradation, allowing for sustained release of the drug cargos. Its utility in unobtrusive topical delivery of chemotherapy with minimal side effects is demonstrated in a murine melanoma model.
- 19 June 2019
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 13 (7) , 7898-7904
Sensor-Instrumented Scaffold Integrated with Microporous Spongelike Ultrabuoy for Long-Term 3D Mapping of Cellular Behaviors and Functions
Real-time monitoring of cellular behaviors and functions with sensor-instrumented scaffolds can provide a profound impact on fundamental studies of the underlying biophysics and disease modeling. Although quantitative measurement of predictive data for in vivo tests and physiologically relevant information in these contexts is important, the long-term reliable monitoring of cellular functions in three-dimensional (3D) environments is limited by the required set under wet cell culture conditions that are unfavorable to electronic instrument settings. Here, we introduce an ultra-buoyant 3D instrumented scaffold that can remain afloat on the surface of culture medium, and thereby provides favorable environments for the entire electronic components in the air while the cells reside and grow underneath. This setting enables high-fidelity recording of electrical cell-substrate impedance and electrophysiological signals for a long period of time (weeks). Comprehensive in vitro studies reveal the utility of this platform in an effective tool for drug screening and tissue development.
- 19 June 2019
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 13 (7) , 7898-7904
Sensor-Instrumented Scaffold Integrated with Microporous Spongelike Ultrabuoy for Long-Term 3D Mapping of Cellular Behaviors and Functions
Real-time monitoring of cellular behaviors and functions with sensor-instrumented scaffolds can provide a profound impact on fundamental studies of the underlying biophysics and disease modeling. Although quantitative measurement of predictive data for in vivo tests and physiologically relevant information in these contexts is important, the long-term reliable monitoring of cellular functions in three-dimensional (3D) environments is limited by the required set under wet cell culture conditions that are unfavorable to electronic instrument settings. Here, we introduce an ultra-buoyant 3D instrumented scaffold that can remain afloat on the surface of culture medium, and thereby provides favorable environments for the entire electronic components in the air while the cells reside and grow underneath. This setting enables high-fidelity recording of electrical cell-substrate impedance and electrophysiological signals for a long period of time (weeks). Comprehensive in vitro studies reveal the utility of this platform in an effective tool for drug screening and tissue development.
- Open Access
- 2 November 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 4 (11) , eaau6972
Flexible elastomer patch with vertical silicon nanoneedles for intracellular and intratissue nanoinjection of biomolecules
A thin transparent wearable patch with silicon nanoneedles is developed for efficient interface with biological cells and tissues.
- 2 November 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 4 (11) , eaau6972
Open AccessFlexible elastomer patch with vertical silicon nanoneedles for intracellular and intratissue nanoinjection of biomolecules
A thin transparent wearable patch with silicon nanoneedles is developed for efficient interface with biological cells and tissues.
- 22 May 2017
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 11 (7) , 6853-6859
Three-Dimensional Hetero-Integration of Faceted GaN on Si Pillars for Efficient Light Energy Conversion Devices
An important pathway for cost-effective light energy conversion devices, such as solar cells and light emitting diodes, is to integrate III–V (e.g., GaN) materials on Si substrates. Such integration first necessitates growth of high crystalline III–V materials on Si, which has been the focus of many studies. However, the integration also requires that the final III–V/Si structure has a high light energy conversion efficiency. To accomplish these twin goals, we use single-crystalline microsized Si pillars as a seed layer to first grow faceted Si structures, which are then used for the heteroepitaxial growth of faceted GaN films. These faceted GaN films on Si have high crystallinity, and their threading dislocation density is similar to that of GaN grown on sapphire. In addition, the final faceted GaN/Si structure has great light absorption and extraction characteristics, leading to improved performance for GaN-on-Si light energy conversion devices.
- 22 May 2017
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 11 (7) , 6853-6859
Three-Dimensional Hetero-Integration of Faceted GaN on Si Pillars for Efficient Light Energy Conversion Devices
An important pathway for cost-effective light energy conversion devices, such as solar cells and light emitting diodes, is to integrate III–V (e.g., GaN) materials on Si substrates. Such integration first necessitates growth of high crystalline III–V materials on Si, which has been the focus of many studies. However, the integration also requires that the final III–V/Si structure has a high light energy conversion efficiency. To accomplish these twin goals, we use single-crystalline microsized Si pillars as a seed layer to first grow faceted Si structures, which are then used for the heteroepitaxial growth of faceted GaN films. These faceted GaN films on Si have high crystallinity, and their threading dislocation density is similar to that of GaN grown on sapphire. In addition, the final faceted GaN/Si structure has great light absorption and extraction characteristics, leading to improved performance for GaN-on-Si light energy conversion devices.
- 7 March 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (11) , 9213-9220
Facile Fabrication of Superomniphobic Polymer Hierarchical Structures for Directional Droplet Movement
We report a facile method for fabricating polymer hierarchical structures, which are the engineered, ratchet-like microscale structures with nanoscale dimples, for the directional movement of droplets. The fabricated polymer hierarchical structures with no surface modifier show hydrophobic, superhydrophobic, or omniphobic characteristics depending on their intrinsic polymer properties. Further treatment with a surface modifier endows the polymer surfaces with superomniphobicity. The fabricated polymer substrates with no surface modifier enable the movement of the water droplet along the designed track at almost no inclination of the substrate.
- 7 March 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (11) , 9213-9220
Facile Fabrication of Superomniphobic Polymer Hierarchical Structures for Directional Droplet Movement
We report a facile method for fabricating polymer hierarchical structures, which are the engineered, ratchet-like microscale structures with nanoscale dimples, for the directional movement of droplets. The fabricated polymer hierarchical structures with no surface modifier show hydrophobic, superhydrophobic, or omniphobic characteristics depending on their intrinsic polymer properties. Further treatment with a surface modifier endows the polymer surfaces with superomniphobicity. The fabricated polymer substrates with no surface modifier enable the movement of the water droplet along the designed track at almost no inclination of the substrate.