Stefan Salminger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stefan Salminger has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Oskar Christian Aszmann
Clinical Laboratory for Bionic Extremity Reconstruction, Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria
18 shared publications - Konstantin Davide Bergmeister
Karl Landsteiner University of Health Sciences, Dr. Karl-Dorrek-Straße 30, 3500 Krems, Austria
11 shared publications Agnes Sturma
Clinical Laboratory for Bionic Extremity Reconstruction, Department of Surgery, Medical University of Vienna, Vienna, Austria
8 shared publicationsA. Sturma
Christian Doppler Labor für Wiederherstellung von Extremitätenfunktionen, Medizinische Universität Wien, Österreich
6 shared publicationsChristian Hofer
Otto Bock Health Care Products GmbH, Vienna, Austria
6 shared publicationsO. Riedl
Klinische Abteilung für Plastische und Rekonstruktive Chirurgie, Universitätsklinik für Chirurgie, Medizinische Universität Wien, Österreich
6 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (3)
Resection-Replantation vs. Bionic Reconstruction to Restore Hand Function
Aim: Above-elbow amputation results in profound functional and psychosocial impairments. Modern bionic reconstruction has improved outcomes in these patients, but several limitations remain. In situations where the hand remains unaffected by trauma or tumor, segmental limb resection followed by immediate replantation offers a viable alternative to amputation. However, comparative functional outcome data between these approaches are lacking. To guide clinical decision-making, this study aimed to compare functional outcomes after resection-replantation (RR) and modern bionic reconstruction (BR) at the transhumeral level. Methods: In a cross-sectional comparative study, outcomes were assessed in 2 patient groups. RR (n = 3) underwent transhumeral resection and distal limb replantation, whereas BR (n = 3) had transhumeral amputation followed by bionic reconstruction, including targeted muscle reinnervation and osseointegration. Functional outcomes were evaluated using the Southampton Hand Assessment Procedure (SHAP). Additional assessments included subjective impairment of limb function, health-related quality of life, limb-related pain, and embodiment. Sensation, grip strength, and pinch strength were further evaluated in RR patients. Results: Median follow-up was 4.5 years in RR (range 3-51) and 2 years in BR (range 2-5). SHAP scores were higher in RR (mean 78, range 74-84) than in BR (mean 30, range 29-31). Amputation-related pain was reported in 2 BR patients, while no RR patients suffered pain as a result of the intervention. Other outcome measures were comparable between groups. All RR patients retained critical sensation in the hand, while grip and pinch strength were similar to those achieved with prosthetic hands. Conclusions: RR demonstrated superior functional outcomes compared with BR at the transhumeral level. In addition to enhanced function, this approach was not associated with phantom-limb pain, promoted a high degree of embodiment and avoided prosthetic-related costs. The preservation of sensation and proprioception likely plays a critical role in improved functionality. Where RR is feasible in selected cases of upper extremity trauma or tumor, it should be considered a preferred alternative to above-elbow amputation for restoring hand function. Evidence Level: Level IV : Prognostic. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (3)
Open AccessResection-Replantation vs. Bionic Reconstruction to Restore Hand Function
Aim: Above-elbow amputation results in profound functional and psychosocial impairments. Modern bionic reconstruction has improved outcomes in these patients, but several limitations remain. In situations where the hand remains unaffected by trauma or tumor, segmental limb resection followed by immediate replantation offers a viable alternative to amputation. However, comparative functional outcome data between these approaches are lacking. To guide clinical decision-making, this study aimed to compare functional outcomes after resection-replantation (RR) and modern bionic reconstruction (BR) at the transhumeral level. Methods: In a cross-sectional comparative study, outcomes were assessed in 2 patient groups. RR (n = 3) underwent transhumeral resection and distal limb replantation, whereas BR (n = 3) had transhumeral amputation followed by bionic reconstruction, including targeted muscle reinnervation and osseointegration. Functional outcomes were evaluated using the Southampton Hand Assessment Procedure (SHAP). Additional assessments included subjective impairment of limb function, health-related quality of life, limb-related pain, and embodiment. Sensation, grip strength, and pinch strength were further evaluated in RR patients. Results: Median follow-up was 4.5 years in RR (range 3-51) and 2 years in BR (range 2-5). SHAP scores were higher in RR (mean 78, range 74-84) than in BR (mean 30, range 29-31). Amputation-related pain was reported in 2 BR patients, while no RR patients suffered pain as a result of the intervention. Other outcome measures were comparable between groups. All RR patients retained critical sensation in the hand, while grip and pinch strength were similar to those achieved with prosthetic hands. Conclusions: RR demonstrated superior functional outcomes compared with BR at the transhumeral level. In addition to enhanced function, this approach was not associated with phantom-limb pain, promoted a high degree of embodiment and avoided prosthetic-related costs. The preservation of sensation and proprioception likely plays a critical role in improved functionality. Where RR is feasible in selected cases of upper extremity trauma or tumor, it should be considered a preferred alternative to above-elbow amputation for restoring hand function. Evidence Level: Level IV : Prognostic. See Instructions for Authors for a complete description of levels of evidence.
- 3 May 2022
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 46 (5) , 408-413
Actual prosthetic usage in relation to functional outcomes and wearing time in individuals with below-elbow amputation
Background: Wearing time of a prosthesis is regarded as an indicator for success of prosthetic rehabilitation. However, prostheses are frequently worn for esthetic purposes only. Although different supervised measurements to assess prosthetic dexterity are used, it is not clear how performance in such tests translates into actual use in everyday life. Objectives: To evaluate the actual daily use of the prosthetic device in patients with below-elbow amputations by recording the number of grasping motions. Study design: Observational study. Methods: Upper extremity function was evaluated using different objective and timed assessments in five unilateral patients with below-elbow amputations. In addition, patients reported daily wearing time, and the number of performed prosthetic movements over a period of at least three months was recorded. Results: The patients achieved a mean Southampton Hand Assessment Procedure score of 66.60 ± 18.64 points. The average blocks moved in the Box and Block Test were 20.80 ± 7.46, and the mean score in the Action Research Arm Test was 37.20 ± 5.45. The mean time for the Clothespin-Relocation Test was 26.90 ± 11.61 seconds. The patients reported a wearing time of an average of 12.80 ± 3.11 hours per day. The mean number of prosthetic motions performed each day was 257.23 ± 192.95 with a range from 23.07 to 489.13. Conclusions: Neither high functionality nor long wearing times necessitated frequent use of a prosthesis in daily life. However, frequent daily motions did translate into good functional scores, indicating that regular device use in different real-life settings relates to functionality.
- 3 May 2022
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 46 (5) , 408-413
Actual prosthetic usage in relation to functional outcomes and wearing time in individuals with below-elbow amputation
Background: Wearing time of a prosthesis is regarded as an indicator for success of prosthetic rehabilitation. However, prostheses are frequently worn for esthetic purposes only. Although different supervised measurements to assess prosthetic dexterity are used, it is not clear how performance in such tests translates into actual use in everyday life. Objectives: To evaluate the actual daily use of the prosthetic device in patients with below-elbow amputations by recording the number of grasping motions. Study design: Observational study. Methods: Upper extremity function was evaluated using different objective and timed assessments in five unilateral patients with below-elbow amputations. In addition, patients reported daily wearing time, and the number of performed prosthetic movements over a period of at least three months was recorded. Results: The patients achieved a mean Southampton Hand Assessment Procedure score of 66.60 ± 18.64 points. The average blocks moved in the Box and Block Test were 20.80 ± 7.46, and the mean score in the Action Research Arm Test was 37.20 ± 5.45. The mean time for the Clothespin-Relocation Test was 26.90 ± 11.61 seconds. The patients reported a wearing time of an average of 12.80 ± 3.11 hours per day. The mean number of prosthetic motions performed each day was 257.23 ± 192.95 with a range from 23.07 to 489.13. Conclusions: Neither high functionality nor long wearing times necessitated frequent use of a prosthesis in daily life. However, frequent daily motions did translate into good functional scores, indicating that regular device use in different real-life settings relates to functionality.
- 15 September 2020
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (1) , 76-80
Successful salvage via re-osseointegration of a loosened implant in a patient with transtibial amputation
Case Description: Osseointegration is a relatively new technique for prosthetic limb attachment that offers various improvements for patients with amputation and facilitates joint preservation. We present a case of implant loosening during rehabilitation in a patient with transtibial amputation that was successfully managed through a combination of measures, aiming to promote re-osseointegration of the implant. Objectives: Not much is known about structured management of adverse events after osseointegration. Septic or aseptic loosening is currently regarded as implant failure, prompting removal and possible re-implantation at a later stage. The objective of this case report was to evaluate the feasibility of salvaging a loosened implant. Study Design: Case report. Treatment: A novel treatment approach was employed to enable renewed osseointegration of the implant. First, the bone-implant interface was disrupted and renewed through axial rotation and distal repositioning of the implant. Afterwards, extracorporal shockwave therapy and antibiotic treatment were administered. Prosthetic rehabilitation was then started anew. Regular follow-up x-rays and clinical evaluations were conducted, including standardized outcome tests. Outcomes: These combined measures led to a successful re-osseointegration of the implant. In a 21-month follow-up, the patient regained a stable and secure gait pattern, using his prosthesis every day for 15 hours and scoring above average on standardized outcome measures. Conclusion: This represents the first report of implant salvage after failed primary osseointegration. As the associated risks of this novel treatment are very low, investigations are warranted to evaluate this approach on a larger scale.
- 15 September 2020
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (1) , 76-80
Successful salvage via re-osseointegration of a loosened implant in a patient with transtibial amputation
Case Description: Osseointegration is a relatively new technique for prosthetic limb attachment that offers various improvements for patients with amputation and facilitates joint preservation. We present a case of implant loosening during rehabilitation in a patient with transtibial amputation that was successfully managed through a combination of measures, aiming to promote re-osseointegration of the implant. Objectives: Not much is known about structured management of adverse events after osseointegration. Septic or aseptic loosening is currently regarded as implant failure, prompting removal and possible re-implantation at a later stage. The objective of this case report was to evaluate the feasibility of salvaging a loosened implant. Study Design: Case report. Treatment: A novel treatment approach was employed to enable renewed osseointegration of the implant. First, the bone-implant interface was disrupted and renewed through axial rotation and distal repositioning of the implant. Afterwards, extracorporal shockwave therapy and antibiotic treatment were administered. Prosthetic rehabilitation was then started anew. Regular follow-up x-rays and clinical evaluations were conducted, including standardized outcome tests. Outcomes: These combined measures led to a successful re-osseointegration of the implant. In a 21-month follow-up, the patient regained a stable and secure gait pattern, using his prosthesis every day for 15 hours and scoring above average on standardized outcome measures. Conclusion: This represents the first report of implant salvage after failed primary osseointegration. As the associated risks of this novel treatment are very low, investigations are warranted to evaluate this approach on a larger scale.
- 17 July 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 4 (32)
Long-term implant of intramuscular sensors and nerve transfers for wireless control of robotic arms in above-elbow amputees
The use of implantable myoelectric sensors showed substantial improvements in prosthetic function of above-elbow amputees.
- 17 July 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 4 (32)
Long-term implant of intramuscular sensors and nerve transfers for wireless control of robotic arms in above-elbow amputees
The use of implantable myoelectric sensors showed substantial improvements in prosthetic function of above-elbow amputees.
- 1 February 2018
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 42 (1) , 93-100
Attachment of upper arm prostheses with a subcutaneous osseointegrated implant in transhumeral amputees
Background: The stump–socket interface is of utmost importance for prosthetic function in transhumeral amputees. Stability of this connection may be improved using a newly designed subcutaneous implant. Objectives: The purpose was to determine the effect of the implant together with customized socket designs on the range of motion of the shoulder and the prosthetic function compared to conventional fitting. Study design: Case series. Methods: The range of motion was measured with scaled metrics and the prosthetic function evaluated with the Southampton Hand Assessment Procedure and the Box and Block Test. Maximal loading was measured in straight and 90° flexion of the elbow. Results: The restriction of range of motion after conventional fitting was decreased from 42.55% ± 6.56% to 9.23% ± 14.89% in Patient I and from 62.18% ± 15.19% to 2.51% ± 2.49% in Patient II using the implant with customized sockets compared to range of motion without prosthesis. Both patients showed improved prosthetic function with the new system compared to conventional fitting. Conclusion: The presented subcutaneous humeral implant, together with customized socket designs without straps and harnesses to the contralateral shoulder, can maintain almost complete range of motion of the shoulder. This resulted in improved prosthetic function and comfort for the patient without constant risk of infection. Clinical relevance Discomfort and limited prosthetic function are the main reasons for abandonment especially in transhumeral amputees. Shoulder straps and harnesses within conventional socket designs may not only lead to pain and skin irritations at the contralateral shoulder but also limit the range of motion of the shoulder joint and therefore prosthetic function.
- 1 February 2018
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 42 (1) , 93-100
Attachment of upper arm prostheses with a subcutaneous osseointegrated implant in transhumeral amputees
Background: The stump–socket interface is of utmost importance for prosthetic function in transhumeral amputees. Stability of this connection may be improved using a newly designed subcutaneous implant. Objectives: The purpose was to determine the effect of the implant together with customized socket designs on the range of motion of the shoulder and the prosthetic function compared to conventional fitting. Study design: Case series. Methods: The range of motion was measured with scaled metrics and the prosthetic function evaluated with the Southampton Hand Assessment Procedure and the Box and Block Test. Maximal loading was measured in straight and 90° flexion of the elbow. Results: The restriction of range of motion after conventional fitting was decreased from 42.55% ± 6.56% to 9.23% ± 14.89% in Patient I and from 62.18% ± 15.19% to 2.51% ± 2.49% in Patient II using the implant with customized sockets compared to range of motion without prosthesis. Both patients showed improved prosthetic function with the new system compared to conventional fitting. Conclusion: The presented subcutaneous humeral implant, together with customized socket designs without straps and harnesses to the contralateral shoulder, can maintain almost complete range of motion of the shoulder. This resulted in improved prosthetic function and comfort for the patient without constant risk of infection. Clinical relevance Discomfort and limited prosthetic function are the main reasons for abandonment especially in transhumeral amputees. Shoulder straps and harnesses within conventional socket designs may not only lead to pain and skin irritations at the contralateral shoulder but also limit the range of motion of the shoulder joint and therefore prosthetic function.
- 1 November 2017
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 127 (5) , 1163-1171
Algorithm for bionic hand reconstruction in patients with global brachial plexopathies
OBJECTIVE: Global brachial plexus lesions with multiple root avulsions are among the most severe nerve injuries, leading to lifelong disability. Fortunately, in most cases primary and secondary reconstructions provide a stable shoulder and restore sufficient arm function. Restoration of biological hand function, however, remains a reconstructive goal that is difficult to reach. The recently introduced concept of bionic reconstruction overcomes biological limitations of classic reconstructive surgery to restore hand function by combining selective nerve and muscle transfers with elective amputation of the functionless hand and its replacement with a prosthetic device. The authors present their treatment algorithm for bionic hand reconstruction and report on the management and long-term functional outcomes of patients with global brachial plexopathies who have undergone this innovative treatment.METHODS: Thirty-four patients with posttraumatic global brachial plexopathies leading to loss of hand function consulted the Center for Advanced Restoration of Extremity Function between 2011 and 2015. Of these patients, 16 (47%) qualified for bionic reconstruction due to lack of treatment alternatives. The treatment algorithm included progressive steps with the intent of improving the biotechnological interface to allow optimal prosthetic hand replacement. In 5 patients, final functional outcome measurements were obtained with the Action Arm Research Test (ARAT), the Southampton Hand Assessment Procedure (SHAP), and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire.RESULTS: In all 5 patients who completed functional assessments, partial hand function was restored with bionic reconstruction. ARAT scores improved from 3.4 ± 4.3 to 25.4 ± 12.7 (p = 0.043; mean ± SD) and SHAP scores improved from 10.0 ± 1.6 to 55 ± 19.7 (p = 0.042). DASH scores decreased from 57.9 ± 20.6 to 32 ± 28.6 (p = 0.042), indicating decreased disability.CONCLUSIONS: The authors present an algorithm for bionic reconstruction leading to useful hand function in patients who lack biological treatment alternatives for a stiff, functionless, and insensate hand resulting from global brachial plexopathies.
- 1 November 2017
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 127 (5) , 1163-1171
Algorithm for bionic hand reconstruction in patients with global brachial plexopathies
OBJECTIVE: Global brachial plexus lesions with multiple root avulsions are among the most severe nerve injuries, leading to lifelong disability. Fortunately, in most cases primary and secondary reconstructions provide a stable shoulder and restore sufficient arm function. Restoration of biological hand function, however, remains a reconstructive goal that is difficult to reach. The recently introduced concept of bionic reconstruction overcomes biological limitations of classic reconstructive surgery to restore hand function by combining selective nerve and muscle transfers with elective amputation of the functionless hand and its replacement with a prosthetic device. The authors present their treatment algorithm for bionic hand reconstruction and report on the management and long-term functional outcomes of patients with global brachial plexopathies who have undergone this innovative treatment.METHODS: Thirty-four patients with posttraumatic global brachial plexopathies leading to loss of hand function consulted the Center for Advanced Restoration of Extremity Function between 2011 and 2015. Of these patients, 16 (47%) qualified for bionic reconstruction due to lack of treatment alternatives. The treatment algorithm included progressive steps with the intent of improving the biotechnological interface to allow optimal prosthetic hand replacement. In 5 patients, final functional outcome measurements were obtained with the Action Arm Research Test (ARAT), the Southampton Hand Assessment Procedure (SHAP), and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire.RESULTS: In all 5 patients who completed functional assessments, partial hand function was restored with bionic reconstruction. ARAT scores improved from 3.4 ± 4.3 to 25.4 ± 12.7 (p = 0.043; mean ± SD) and SHAP scores improved from 10.0 ± 1.6 to 55 ± 19.7 (p = 0.042). DASH scores decreased from 57.9 ± 20.6 to 32 ± 28.6 (p = 0.042), indicating decreased disability.CONCLUSIONS: The authors present an algorithm for bionic reconstruction leading to useful hand function in patients who lack biological treatment alternatives for a stiff, functionless, and insensate hand resulting from global brachial plexopathies.
- Open Access
- 20 October 2017
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 37 (46) , 11285-11292
Common Synaptic Input to Motor Neurons and Neural Drive to Targeted Reinnervated Muscles
We compared the behavior of motor neurons innervating their physiological muscle targets with motor neurons from the same spinal segment whose axons were surgically redirected to remnant muscles (targeted muscle reinnervation). The objective was to assess whether motor neurons with nonphysiological innervation receive similar synaptic input and could be voluntary controlled as motor neurons with natural innervation. For this purpose, we acquired high-density EMG signals from the biceps brachii in 5 male transhumeral amputees who underwent targeted reinnervation of this muscle by the ulnar nerve and from the first dorsal interosseous muscle of 5 healthy individuals to investigate the natural innervation of the ulnar nerve. The same recordings were also performed from the biceps brachii muscle of additional 5 able-bodied individuals. The EMG signals were decomposed into discharges of motor unit action potentials. Motor neurons were progressively recruited for the full range of submaximal muscle activation in all conditions. Moreover, their discharge rate significantly increased from recruitment to target activation level in a similar way across the subject groups. Motor neurons across all subject groups received common synaptic input as identified by coherence analysis of their spike trains. However, the relative strength of common input in both the delta (0.5–5 Hz) and alpha (5–13 Hz) bands was significantly smaller for the surgically reinnervated motor neuron pool with respect to the corresponding physiologically innervated one. The results support the novel approach of motor neuron interfacing for prosthesis control and provide new insights into the role of afferent input on motor neuron activity.SIGNIFICANCE STATEMENTTargeted muscle reinnervation surgically redirects nerves that lost their target in the amputation into redundant muscles in the region of the stump. The study of the behavior of motor neurons following this surgery is needed for designing biologically inspired prosthetic control strategies. Moreover, targeted muscle reinnervation offers a human experimental framework for studying the control and behavior of motor neurons when changing their target innervated muscle fibers and sensory feedback. Here, we show that the control of motor neurons and their synaptic input, following reinnervation, was remarkably similar to that of the physiological innervation, although with reduced common drive at some frequencies. The results advance our knowledge on the role of sensory input in the generation of the neural drive to muscles and provide the basis for designing physiologically inspired methods for prosthesis control.
- 20 October 2017
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 37 (46) , 11285-11292
Open AccessCommon Synaptic Input to Motor Neurons and Neural Drive to Targeted Reinnervated Muscles
We compared the behavior of motor neurons innervating their physiological muscle targets with motor neurons from the same spinal segment whose axons were surgically redirected to remnant muscles (targeted muscle reinnervation). The objective was to assess whether motor neurons with nonphysiological innervation receive similar synaptic input and could be voluntary controlled as motor neurons with natural innervation. For this purpose, we acquired high-density EMG signals from the biceps brachii in 5 male transhumeral amputees who underwent targeted reinnervation of this muscle by the ulnar nerve and from the first dorsal interosseous muscle of 5 healthy individuals to investigate the natural innervation of the ulnar nerve. The same recordings were also performed from the biceps brachii muscle of additional 5 able-bodied individuals. The EMG signals were decomposed into discharges of motor unit action potentials. Motor neurons were progressively recruited for the full range of submaximal muscle activation in all conditions. Moreover, their discharge rate significantly increased from recruitment to target activation level in a similar way across the subject groups. Motor neurons across all subject groups received common synaptic input as identified by coherence analysis of their spike trains. However, the relative strength of common input in both the delta (0.5–5 Hz) and alpha (5–13 Hz) bands was significantly smaller for the surgically reinnervated motor neuron pool with respect to the corresponding physiologically innervated one. The results support the novel approach of motor neuron interfacing for prosthesis control and provide new insights into the role of afferent input on motor neuron activity.SIGNIFICANCE STATEMENTTargeted muscle reinnervation surgically redirects nerves that lost their target in the amputation into redundant muscles in the region of the stump. The study of the behavior of motor neurons following this surgery is needed for designing biologically inspired prosthetic control strategies. Moreover, targeted muscle reinnervation offers a human experimental framework for studying the control and behavior of motor neurons when changing their target innervated muscle fibers and sensory feedback. Here, we show that the control of motor neurons and their synaptic input, following reinnervation, was remarkably similar to that of the physiological innervation, although with reduced common drive at some frequencies. The results advance our knowledge on the role of sensory input in the generation of the neural drive to muscles and provide the basis for designing physiologically inspired methods for prosthesis control.
- 17 October 2017
- Published by Georg Thieme Verlag KG in Handchirurgie · Mikrochirurgie · Plastische Chirurgie
- Vol. 49 (05) , 344-347
Frustrane Daumen-Replantation distal eines Dialyse-Shunts
Die Erfolgsraten bei der Replantation von amputierten Fingern sind in den letzten Jahrzenten stetig gestiegen, wobei die Erfolgsraten von verschiedensten Faktoren abhängig sind [1], [2]. Einen negativen Einfluss auf die Erfolgsrate haben sowohl der Pathomechanismus (z. B. Avulsionsverletzungen oder Totalamputationen) sowie ein hohes Alter des Patienten und lange Ischmämiezeiten [2]. In Bezug auf die Indikationsstellung für eine Replantation gibt es international unterschiedliche Empfehlungen [1], [3], [4]. Eine Amputation des Daumens auf Grundgliedhöhe stellt jedoch fast immer eine Indikation dar [1], da dieser 40–50 % der gesamten Handfunktion ausmacht [5] und damit unabhängig von dem Wiedererlangen des Bewegungsumfanges oder der Sensibilität im Alltag sinnvoll eingesetzt werden kann und von den Patienten als Bereicherung empfunden wird [1]. Aufgrund der verbesserten Sicherheitsmaßnahmen der letzten Jahrzehnte sinkt die Anzahl an Amputation der oberen Extremität, im speziellen Fingeramputationen, stetig [6]. Im Gegensatz dazu steigen allerdings die Komorbiditäten betroffener Patienten, z. B. wie in folgendem Fallbeispiel die chronische Niereninsuffizienz. Bei hämodialysepflichtigen Patienten wird zu meist eine radio-cephale arterio-venöse Fistel (AVF) am nicht dominanten Arm in End-zu-Seit-Technik angelegt. Diese führt zu einer Veränderung der Hämodynamik im Bereich der AVF als auch distal dieser. Es kann zu einer Minderperfusion distal der AVF kommen (Hämodialysezugang induzierte distale Handischämie (HAIDI)), welche am Daumen am gravierendsten ist [7], [8]. HAIDI stellt mit einer Inzidenz von 1–9 % eine der relevantesten Komplikationen nach Shuntanlage dar [7]. Sie kann als akute Form wenige Stunden nach der Shuntanlage auftreten, aber auch protrahiert nach Monaten und Jahren [9]. Eine klinisch relevante HAIDI ist durch ein Kältegefühl, Taubheit oder Schmerzen sowie Ulzerationen und Nekrosen charakterisiert [7]. Jedoch tritt eine Verringerung des Hautperfusionsdruckes distal der AVF auch bei Patienten ohne jegliche klinische Beschwerden auf [7]. Risikofaktoren für das Auftreten einer HAIDI sind höheres Alter, weibliches Geschlecht, Diabetes, KHK, Hypertension sowie eine AVF der A. brachialis [7–9]. Im Folgenden wird von einer sekundär frustranen Replantation des dominanten Daumenendgliedes bei einem Patienten mit einer arterio-venösen radio-cephalen Fistel berichtet.
- 17 October 2017
- Published by Georg Thieme Verlag KG in Handchirurgie · Mikrochirurgie · Plastische Chirurgie
- Vol. 49 (05) , 344-347
Frustrane Daumen-Replantation distal eines Dialyse-Shunts
Die Erfolgsraten bei der Replantation von amputierten Fingern sind in den letzten Jahrzenten stetig gestiegen, wobei die Erfolgsraten von verschiedensten Faktoren abhängig sind [1], [2]. Einen negativen Einfluss auf die Erfolgsrate haben sowohl der Pathomechanismus (z. B. Avulsionsverletzungen oder Totalamputationen) sowie ein hohes Alter des Patienten und lange Ischmämiezeiten [2]. In Bezug auf die Indikationsstellung für eine Replantation gibt es international unterschiedliche Empfehlungen [1], [3], [4]. Eine Amputation des Daumens auf Grundgliedhöhe stellt jedoch fast immer eine Indikation dar [1], da dieser 40–50 % der gesamten Handfunktion ausmacht [5] und damit unabhängig von dem Wiedererlangen des Bewegungsumfanges oder der Sensibilität im Alltag sinnvoll eingesetzt werden kann und von den Patienten als Bereicherung empfunden wird [1]. Aufgrund der verbesserten Sicherheitsmaßnahmen der letzten Jahrzehnte sinkt die Anzahl an Amputation der oberen Extremität, im speziellen Fingeramputationen, stetig [6]. Im Gegensatz dazu steigen allerdings die Komorbiditäten betroffener Patienten, z. B. wie in folgendem Fallbeispiel die chronische Niereninsuffizienz. Bei hämodialysepflichtigen Patienten wird zu meist eine radio-cephale arterio-venöse Fistel (AVF) am nicht dominanten Arm in End-zu-Seit-Technik angelegt. Diese führt zu einer Veränderung der Hämodynamik im Bereich der AVF als auch distal dieser. Es kann zu einer Minderperfusion distal der AVF kommen (Hämodialysezugang induzierte distale Handischämie (HAIDI)), welche am Daumen am gravierendsten ist [7], [8]. HAIDI stellt mit einer Inzidenz von 1–9 % eine der relevantesten Komplikationen nach Shuntanlage dar [7]. Sie kann als akute Form wenige Stunden nach der Shuntanlage auftreten, aber auch protrahiert nach Monaten und Jahren [9]. Eine klinisch relevante HAIDI ist durch ein Kältegefühl, Taubheit oder Schmerzen sowie Ulzerationen und Nekrosen charakterisiert [7]. Jedoch tritt eine Verringerung des Hautperfusionsdruckes distal der AVF auch bei Patienten ohne jegliche klinische Beschwerden auf [7]. Risikofaktoren für das Auftreten einer HAIDI sind höheres Alter, weibliches Geschlecht, Diabetes, KHK, Hypertension sowie eine AVF der A. brachialis [7–9]. Im Folgenden wird von einer sekundär frustranen Replantation des dominanten Daumenendgliedes bei einem Patienten mit einer arterio-venösen radio-cephalen Fistel berichtet.
- Open Access
- 19 July 2017
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 11, 421
Broadband Prosthetic Interfaces: Combining Nerve Transfers and Implantable Multichannel EMG Technology to Decode Spinal Motor Neuron Activity
Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user’s intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.
- 19 July 2017
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 11, 421
Open AccessBroadband Prosthetic Interfaces: Combining Nerve Transfers and Implantable Multichannel EMG Technology to Decode Spinal Motor Neuron Activity
Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user’s intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces.
- 28 March 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 121,p. e55441
A Rapid Automated Protocol for Muscle Fiber Population Analysis in Rat Muscle Cross Sections Using Myosin Heavy Chain Immunohistochemistry
Here, we present a protocol for rapid muscle fiber analyses, which allows improved staining quality, and thereby automatic acquisition...
- 28 March 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 121,p. e55441
A Rapid Automated Protocol for Muscle Fiber Population Analysis in Rat Muscle Cross Sections Using Myosin Heavy Chain Immunohistochemistry
Here, we present a protocol for rapid muscle fiber analyses, which allows improved staining quality, and thereby automatic acquisition...