Xiao-Ming Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiao-Ming Sun has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Duck On Kim
Department of Neuroscience, University of Connecticut Health Center, Farmington, Connecticut
5 shared publications Mark D. Shaver
Department of Communication Sciences and Disorders, Wichita State University, 1845 Fairmount Street, Wichita, Kansas 67260-0075, USA
3 shared publicationsM. D. Jung
2 shared publicationsCarla Dominguez Carazo
Department of Communication Sciences and Disorders, Wichita State University , Wichita, Kansas , USA
1 shared publication- Fawen Zhang
Department of Otolaryngology, Head and Neck Surgery, University of Iowa, Iowa, USA
1 shared publication Flint A. Boettcher
Department of Speech Pathology & Audiology, University of South Alabama, USA
1 shared publication
Latest Publications
- 1 August 2016
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 59 (4) , 819-834
Wideband Acoustic Immittance: Normative Study and Test–Retest Reliability of Tympanometric Measurements in Adults
Purpose: The purpose of this study was to present normative data of tympanometric measurements of wideband acoustic immittance and to characterize wideband tympanograms. Method: Data were collected in 84 young adults with strictly defined normal hearing and middle ear status. Energy absorbance (EA) was measured using clicks for 1/12–octave frequencies (0.236 to 8 kHz), with the ear canal air pressure systematically varied (+200 to −300 daPa). In 40 ears, 7 consecutive trials and a trial of clinical 226-Hz acoustic admittance ( Y a ) tympanometry followed. A cavity test was also conducted. Results: From the wideband EA tympanogram, several EA spectrums and EA tympanograms were derived. Descriptive statistics were performed, and population parameters were estimated. The immediate test–retest reliability was excellent. Effects of ear canal air pressure on EA were examined comprehensively. Differences in EA between tympanometric and ambient-pressure measurements were significant. Single-frequency EA tympanograms exemplified for half-octave frequencies were contrasted. The bandpass EA tympanogram, 0.236- and 1-kHz EA and Y a tympanograms, and 226-Hz Y a tympanogram were compared in 9 variables. Conclusions: This study established a database of wideband tympanograms in healthy adults. The data analyses will promote our understanding of the middle ear transfer function. These data will serve as a reference for further studies in clinical populations.
- 1 August 2016
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 59 (4) , 819-834
Wideband Acoustic Immittance: Normative Study and Test–Retest Reliability of Tympanometric Measurements in Adults
Purpose: The purpose of this study was to present normative data of tympanometric measurements of wideband acoustic immittance and to characterize wideband tympanograms. Method: Data were collected in 84 young adults with strictly defined normal hearing and middle ear status. Energy absorbance (EA) was measured using clicks for 1/12–octave frequencies (0.236 to 8 kHz), with the ear canal air pressure systematically varied (+200 to −300 daPa). In 40 ears, 7 consecutive trials and a trial of clinical 226-Hz acoustic admittance ( Y a ) tympanometry followed. A cavity test was also conducted. Results: From the wideband EA tympanogram, several EA spectrums and EA tympanograms were derived. Descriptive statistics were performed, and population parameters were estimated. The immediate test–retest reliability was excellent. Effects of ear canal air pressure on EA were examined comprehensively. Differences in EA between tympanometric and ambient-pressure measurements were significant. Single-frequency EA tympanograms exemplified for half-octave frequencies were contrasted. The bandpass EA tympanogram, 0.236- and 1-kHz EA and Y a tympanograms, and 226-Hz Y a tympanogram were compared in 9 variables. Conclusions: This study established a database of wideband tympanograms in healthy adults. The data analyses will promote our understanding of the middle ear transfer function. These data will serve as a reference for further studies in clinical populations.
- 1 October 2014
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 57 (5) , 1997-2004
Effects of Consecutive Wideband Tympanometry Trials on Energy Absorbance Measures of the Middle Ear
Purpose: Wideband acoustic immittance (WAI) is a new technique for assessing middle ear transfer function. It includes energy absorbance (EA) measures and can be acquired with the ear canal pressure varied, known as wideband tympanometry (WBTymp). The authors of this study aimed to investigate effects of consecutive WBTymp testing on EA. Method: Data were collected in 29 young adults with normal hearing and middle ear status. Before and after 8 successive WBTymp runs, EA was also measured at ambient pressure. Subsequently, two 226-Hz tympanometry tests were performed. Results: EA systematically changed over the WBTymp trials in a frequency-specific manner: increase for low frequencies (below 1.5 kHz) and decrease for high frequencies (around 2 kHz and 5 to 6 kHz). The changes, although small, were significant. Much larger EA changes were measured at ambient pressure. The test–retest difference of 226-Hz tympanogram measures was much smaller than previously reported. Conclusion: Consecutive tympanometry testing alters EA measures of the middle ear. This phenomenon could be mainly attributed to change in stiffness at the eardrum, called tympanometric preconditioning . This also has effects on baseline WBTymp outcomes. This effect should be taken into account as a procedural variable in both research and clinical applications of WAI measurements.
- 1 October 2014
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 57 (5) , 1997-2004
Effects of Consecutive Wideband Tympanometry Trials on Energy Absorbance Measures of the Middle Ear
Purpose: Wideband acoustic immittance (WAI) is a new technique for assessing middle ear transfer function. It includes energy absorbance (EA) measures and can be acquired with the ear canal pressure varied, known as wideband tympanometry (WBTymp). The authors of this study aimed to investigate effects of consecutive WBTymp testing on EA. Method: Data were collected in 29 young adults with normal hearing and middle ear status. Before and after 8 successive WBTymp runs, EA was also measured at ambient pressure. Subsequently, two 226-Hz tympanometry tests were performed. Results: EA systematically changed over the WBTymp trials in a frequency-specific manner: increase for low frequencies (below 1.5 kHz) and decrease for high frequencies (around 2 kHz and 5 to 6 kHz). The changes, although small, were significant. Much larger EA changes were measured at ambient pressure. The test–retest difference of 226-Hz tympanogram measures was much smaller than previously reported. Conclusion: Consecutive tympanometry testing alters EA measures of the middle ear. This phenomenon could be mainly attributed to change in stiffness at the eardrum, called tympanometric preconditioning . This also has effects on baseline WBTymp outcomes. This effect should be taken into account as a procedural variable in both research and clinical applications of WAI measurements.
- 29 September 2014
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 54 (4) , 241-248
Effects of consecutive trials and test-retest reliability of 1000-Hz tympanometry in adults
Click on the DOI link to access the article (may not be free).Objective: To investigate the effect of consecutive 1000-Hz tympanometry testing on admittance measures, and examine test-retest reliability. Design: Repeated measures with eight trials of 1000-Hz Y-a and B-a/G(a) tympanometry, respectively, in two ears of each subject, followed by repeated 226-Hz tympanometry. Study sample: Twenty-seven normal-hearing young adults. Results: For single-peak tympanograms, peak Y-tm and G(tm) systematically increased across trials with a mean change of 8% and 15% at Trial 8, respectively, whereas B-tm increased marginally. For notched tympanograms, peak Y-tm and B-tm decreased by 23% and 162% at Trial 8, and G(tm) in two cases also decreased (10% on average). Trial 2 and 3 contributed 50% to 70% of the total changes. Test-retest differences of subsequently acquired 1000- and 226-Hz tympanograms were smaller than previously reported. Conclusions: Consecutive testing significantly alters middle-ear admittance in 1000-Hz tympanometry. The outcome is contingent on tympanogram pattern and admittance component: Increase of peak Y-tm and G(tm) in single-peak tympanograms and decrease of all measures in notched tympanograms. The present results complement previous studies on our understanding of the mechanism underlying this effect: a decrease of middle-ear stiffness. The effect of repetitive tympanometry should be accounted for in research involving sequential testing.The Department of Communication Sciences and Disorders at Wichita State University supported the first author's Doctor of Audiology research project in the form of a graduate assistantship and monetary compensation to the participants
- 29 September 2014
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 54 (4) , 241-248
Effects of consecutive trials and test-retest reliability of 1000-Hz tympanometry in adults
Click on the DOI link to access the article (may not be free).Objective: To investigate the effect of consecutive 1000-Hz tympanometry testing on admittance measures, and examine test-retest reliability. Design: Repeated measures with eight trials of 1000-Hz Y-a and B-a/G(a) tympanometry, respectively, in two ears of each subject, followed by repeated 226-Hz tympanometry. Study sample: Twenty-seven normal-hearing young adults. Results: For single-peak tympanograms, peak Y-tm and G(tm) systematically increased across trials with a mean change of 8% and 15% at Trial 8, respectively, whereas B-tm increased marginally. For notched tympanograms, peak Y-tm and B-tm decreased by 23% and 162% at Trial 8, and G(tm) in two cases also decreased (10% on average). Trial 2 and 3 contributed 50% to 70% of the total changes. Test-retest differences of subsequently acquired 1000- and 226-Hz tympanograms were smaller than previously reported. Conclusions: Consecutive testing significantly alters middle-ear admittance in 1000-Hz tympanometry. The outcome is contingent on tympanogram pattern and admittance component: Increase of peak Y-tm and G(tm) in single-peak tympanograms and decrease of all measures in notched tympanograms. The present results complement previous studies on our understanding of the mechanism underlying this effect: a decrease of middle-ear stiffness. The effect of repetitive tympanometry should be accounted for in research involving sequential testing.The Department of Communication Sciences and Disorders at Wichita State University supported the first author's Doctor of Audiology research project in the form of a graduate assistantship and monetary compensation to the participants
- 1 July 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (1) , 332-341
Wideband energy reflectance measurements: Effects of negative middle ear pressure and application of a pressure compensation procedure
The wideband energy reflectance (ER) technique has become popular as a tool for evaluating middle ear function. Negative middle ear pressure (MEP) is a prevalent form of middle ear dysfunction, which may impact application of ER measurements in differential diagnosis. A negative MEP may be countervailed by application of an equivalent negative ear canal pressure. The present study examined ER in the same ears under normal and experimentally induced negative MEP conditions. Thirty-five subjects produced at least one negative MEP each (−40 to −225 daPa). Negative MEP significantly altered ER in a frequency-specific manner that varied with MEP magnitude. ER increased for low- to mid-frequencies with the largest change (∼0.20 to 0.40) occurring between 1 and 1.5 kHz. ER decreased for frequencies above 3 kHz with the largest change (∼–0.10 to –0.25) observed between 4.5 and 5.5 kHz. Magnitude of changes increased as MEP became more negative, as did the frequencies at which maximum changes occurred, and the frequency at which enhancement transitioned to reduction. Ear canal pressure compensation restored ER to near baseline values. This suggests that the compensation procedure adequately mitigates the effects of negative MEP on ER. Theoretical issues and clinical implications are discussed.
- 1 July 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (1) , 332-341
Wideband energy reflectance measurements: Effects of negative middle ear pressure and application of a pressure compensation procedure
The wideband energy reflectance (ER) technique has become popular as a tool for evaluating middle ear function. Negative middle ear pressure (MEP) is a prevalent form of middle ear dysfunction, which may impact application of ER measurements in differential diagnosis. A negative MEP may be countervailed by application of an equivalent negative ear canal pressure. The present study examined ER in the same ears under normal and experimentally induced negative MEP conditions. Thirty-five subjects produced at least one negative MEP each (−40 to −225 daPa). Negative MEP significantly altered ER in a frequency-specific manner that varied with MEP magnitude. ER increased for low- to mid-frequencies with the largest change (∼0.20 to 0.40) occurring between 1 and 1.5 kHz. ER decreased for frequencies above 3 kHz with the largest change (∼–0.10 to –0.25) observed between 4.5 and 5.5 kHz. Magnitude of changes increased as MEP became more negative, as did the frequencies at which maximum changes occurred, and the frequency at which enhancement transitioned to reduction. Ear canal pressure compensation restored ER to near baseline values. This suggests that the compensation procedure adequately mitigates the effects of negative MEP on ER. Theoretical issues and clinical implications are discussed.
- 23 January 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (5) , 333-341
Tympanometric measures in ears with negative middle ear pressure, and tests of some common assumptions
Objective: To test the assumptions concerning the compensation of middle ear pressure (MEP) in using peak Ytm and the tympanogram asymmetry phenomenon, and to address the variability and reliability of 226 Hz tympanometry under negative MEP. Design: (1) Repeated measures in normal ears with experimentally-induced negative MEP; (2) Retrospective analysis of clinical data from ears with negative MEP. Study sample: Experimental data: 57 adult ears. Clinical data: 200 adult ears. Results: Mean peak Ytm significantly increased (˜ 0.10 mmhos) under negative MEPs (> − 190 daPa). TW increased, up to ˜50 daPa, for MEP ≤ − 130 daPa. Vea decreased when MEP ≤ − 190 daPa. With increasing negative MEP, peak Ytm and tympanogram gradient tended to decrease. The within-subject variation of all measures and difference between normal and negative MEP were small. Conclusions: The tympanometry procedure increases peak Ytm in ears with low to moderate negative MEP, and decreases gradient and Vea with high negative MEP. This is referred to as hypercorrection of the admittance and should be accounted for in clinical norms. Results imply that tympanogram asymmetry is due to divergent effects of air pressure on the middle ear. The variability of tympanometry does not increase and reliability not decrease under negative MEP.
- 23 January 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 52 (5) , 333-341
Tympanometric measures in ears with negative middle ear pressure, and tests of some common assumptions
Objective: To test the assumptions concerning the compensation of middle ear pressure (MEP) in using peak Ytm and the tympanogram asymmetry phenomenon, and to address the variability and reliability of 226 Hz tympanometry under negative MEP. Design: (1) Repeated measures in normal ears with experimentally-induced negative MEP; (2) Retrospective analysis of clinical data from ears with negative MEP. Study sample: Experimental data: 57 adult ears. Clinical data: 200 adult ears. Results: Mean peak Ytm significantly increased (˜ 0.10 mmhos) under negative MEPs (> − 190 daPa). TW increased, up to ˜50 daPa, for MEP ≤ − 130 daPa. Vea decreased when MEP ≤ − 190 daPa. With increasing negative MEP, peak Ytm and tympanogram gradient tended to decrease. The within-subject variation of all measures and difference between normal and negative MEP were small. Conclusions: The tympanometry procedure increases peak Ytm in ears with low to moderate negative MEP, and decreases gradient and Vea with high negative MEP. This is referred to as hypercorrection of the admittance and should be accounted for in clinical norms. Results imply that tympanogram asymmetry is due to divergent effects of air pressure on the middle ear. The variability of tympanometry does not increase and reliability not decrease under negative MEP.
- 1 January 2012
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 33 (1) , 69-78
Ear Canal Pressure Variations Versus Negative Middle Ear Pressure: Comparison Using Distortion Product Otoacoustic Emission Measurement in Humans
For more than a century, positive and/or negative ear canal air pressure (ECP) has often been employed to simulate negative middle ear pressure (MEP) in exploring the latter's effect on hearing sensitivity and outcomes of various physiological assessments of the auditory system. However, systematic investigation is lacking on validation of these practices. This study was aimed at comparing these air pressure variations in humans in terms of effect on distortion product otoacoustic emissions (DPOAEs) and discussing certain issues pertaining to the middle ear transfer function. The 2f1 − f2 DPOAE was measured for nine f2 frequencies from 600 to 8000 Hz in 27 adult ears under four air pressure conditions: normal MEP, negative MEP, and positive and negative ECPs. The subjects voluntarily induced negative MEPs with magnitudes ranging from −40 to −420 daPa, as estimated by the tympanometric peak pressure. For each negative MEP, positive and negative ECPs were applied, respectively, at the same magnitude in absolute value as the negative MEP after it was equalized. Negative MEP and ECP variations were compared in terms of change in DPOAE level. Positive ECP resembled negative MEP, showing a distinct frequency-specific model of effect on DPOAE level: (1) DPOAEs were attenuated the greatest for frequencies at and below 1000 Hz, which increased from 4–6 to 10–12 dB with increasing the pressure for the tested range; (2) DPOAE attenuation decreased with increasing frequency and was minimal at 2000 Hz; and (3) DPOAE level significantly declined for the frequencies between 2000 and 6000 Hz and tended to increase for high frequencies. Compared with a negative MEP, an equivalent negative ECP yielded a smaller reduction of DPOAE levels for frequencies below 2000 Hz, as well as 3000 Hz, but greater reduction for frequencies above 4000 Hz. One phenomenon that occurred under all three air pressures was a minimal change of the DPOAE level at 2000 Hz. This resulted in a peak at 2000 Hz in the DPOAE level change versus frequency function. Effects of negative MEP and ECP variations on DPOAEs in human ears are comparable, to a great extent, to findings from previous studies on hearing sensitivity in humans and tympanic membrane vibration at the umbo in human temporal bones. The present study demonstrates that positive ECP can be used to simulate negative MEP in research on the middle ear function in live humans. Results also suggest that long-lasting beliefs regarding the ECP effect on the middle ear conduction should be amended: (1) only positive ECP, not negative ECP, attenuates sound transmission more for low frequencies than for high frequencies, and (2) positive ECP has a greater effect than negative ECP only for low frequencies and not for high frequencies. Discussion of the present results together with those from previous studies sheds light on the middle ear dynamics under diverse pressure changes across the tympanic membrane and proposes that distorted configuration of the tympanic membrane and ossicular chain is the key factor in the effect of MEP or ECP on the middle ear sound transmission for low frequencies.
- 1 January 2012
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 33 (1) , 69-78
Ear Canal Pressure Variations Versus Negative Middle Ear Pressure: Comparison Using Distortion Product Otoacoustic Emission Measurement in Humans
For more than a century, positive and/or negative ear canal air pressure (ECP) has often been employed to simulate negative middle ear pressure (MEP) in exploring the latter's effect on hearing sensitivity and outcomes of various physiological assessments of the auditory system. However, systematic investigation is lacking on validation of these practices. This study was aimed at comparing these air pressure variations in humans in terms of effect on distortion product otoacoustic emissions (DPOAEs) and discussing certain issues pertaining to the middle ear transfer function. The 2f1 − f2 DPOAE was measured for nine f2 frequencies from 600 to 8000 Hz in 27 adult ears under four air pressure conditions: normal MEP, negative MEP, and positive and negative ECPs. The subjects voluntarily induced negative MEPs with magnitudes ranging from −40 to −420 daPa, as estimated by the tympanometric peak pressure. For each negative MEP, positive and negative ECPs were applied, respectively, at the same magnitude in absolute value as the negative MEP after it was equalized. Negative MEP and ECP variations were compared in terms of change in DPOAE level. Positive ECP resembled negative MEP, showing a distinct frequency-specific model of effect on DPOAE level: (1) DPOAEs were attenuated the greatest for frequencies at and below 1000 Hz, which increased from 4–6 to 10–12 dB with increasing the pressure for the tested range; (2) DPOAE attenuation decreased with increasing frequency and was minimal at 2000 Hz; and (3) DPOAE level significantly declined for the frequencies between 2000 and 6000 Hz and tended to increase for high frequencies. Compared with a negative MEP, an equivalent negative ECP yielded a smaller reduction of DPOAE levels for frequencies below 2000 Hz, as well as 3000 Hz, but greater reduction for frequencies above 4000 Hz. One phenomenon that occurred under all three air pressures was a minimal change of the DPOAE level at 2000 Hz. This resulted in a peak at 2000 Hz in the DPOAE level change versus frequency function. Effects of negative MEP and ECP variations on DPOAEs in human ears are comparable, to a great extent, to findings from previous studies on hearing sensitivity in humans and tympanic membrane vibration at the umbo in human temporal bones. The present study demonstrates that positive ECP can be used to simulate negative MEP in research on the middle ear function in live humans. Results also suggest that long-lasting beliefs regarding the ECP effect on the middle ear conduction should be amended: (1) only positive ECP, not negative ECP, attenuates sound transmission more for low frequencies than for high frequencies, and (2) positive ECP has a greater effect than negative ECP only for low frequencies and not for high frequencies. Discussion of the present results together with those from previous studies sheds light on the middle ear dynamics under diverse pressure changes across the tympanic membrane and proposes that distorted configuration of the tympanic membrane and ossicular chain is the key factor in the effect of MEP or ECP on the middle ear sound transmission for low frequencies.
- 1 April 2009
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (2) , 191-202
Effects of Negative Middle Ear Pressure on Distortion Product Otoacoustic Emissions and Application of a Compensation Procedure in Humans
Objective: This study was intended to systematically examine the effect of negative middle ear pressure (MEP) on distortion product otoacoustic emissions (DPOAEs) and to validate a compensation procedure to account for negative MEP encountered in DPOAE measurement. Design: In experiment 1, the 2f1 − f2 DPOAE was measured for nine f2 frequencies from 600 to 8000 Hz in 16 adults under three MEP conditions: normal MEP, negative MEP, and compensated MEP. The subjects' voluntarily induced negative MEPs, with magnitudes ranging from −40 to −420 daPa, were measured tympanometrically with the tympanometric peak pressure. Each negative MEP was then compensated for by applying an equivalent amount of negative air pressure into the ear canal. The three MEP conditions were compared in terms of difference in DPOAE level. Experiment 2 was conducted to measure the DPOAE under normal and negative MEP conditions by using a different system with a higher frequency resolution in 19 subjects. Results: Negative MEP generally attenuated DPOAEs more for low frequencies than for high frequencies. For the frequencies of 1000 Hz and below, the mean DPOAE level was reduced by at least 4 to 6 dB for negative MEPs lower than −100 daPa (i.e., less negative). Reduction of the DPOAE level increased with increasing negative MEP (e.g., 10 to 12 dB for −160 daPa and higher, i.e., more negative). For f2 = 2000, 4000, and 6000 Hz, the effect of negative MEP was not significant. For 3000 Hz, DPOAE-level reduction was significant (e.g., 5 dB for MEP = −70 to −95 daPa and up to 12 dB for −290 to −420 daPa). As a result, a peak at 2000 Hz and a notch at 3000 Hz appeared in the DPOAE change versus frequency function. For 8000 Hz, DPOAE levels tended to increase in high negative MEPs, although the changes were not significant. Intersubject variability in the effect of negative MEP on DPOAEs was large. As the negative MEPs were compensated for, the decreased DPOAE levels were significantly corrected. DPOAEs measured with higher resolution in experiment 2 verified the frequency-specific effects of negative MEPs. Results revealed that the peak and notch in the DPOAE change versus frequency function shifted toward higher frequencies when negative MEP was increased, and a second peak emerged at a higher frequency. Conclusions: Negative MEP substantially decreases DPOAE level for low frequencies and some mid-frequencies but tends to increase DPOAE level for high frequencies. Results suggest that any degree of negative MEP should be corrected to obtain an accurate outcome of DPOAE measurement. The MEP compensation procedure is effective in restoring normal DPOAEs in ears with negative MEPs. Examining changes in DPOAE level under negative MEP allows for further study of the transmission of acoustic signals through an altered middle ear system. A minimal change of DPOAE level at 2000 Hz indicates that the primary resonant frequency of the middle ear is lower than 2000 Hz. The variation in DPOAE change in the middle to high frequency range implies multiple resonances of the middle ear system.
- 1 April 2009
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (2) , 191-202
Effects of Negative Middle Ear Pressure on Distortion Product Otoacoustic Emissions and Application of a Compensation Procedure in Humans
Objective: This study was intended to systematically examine the effect of negative middle ear pressure (MEP) on distortion product otoacoustic emissions (DPOAEs) and to validate a compensation procedure to account for negative MEP encountered in DPOAE measurement. Design: In experiment 1, the 2f1 − f2 DPOAE was measured for nine f2 frequencies from 600 to 8000 Hz in 16 adults under three MEP conditions: normal MEP, negative MEP, and compensated MEP. The subjects' voluntarily induced negative MEPs, with magnitudes ranging from −40 to −420 daPa, were measured tympanometrically with the tympanometric peak pressure. Each negative MEP was then compensated for by applying an equivalent amount of negative air pressure into the ear canal. The three MEP conditions were compared in terms of difference in DPOAE level. Experiment 2 was conducted to measure the DPOAE under normal and negative MEP conditions by using a different system with a higher frequency resolution in 19 subjects. Results: Negative MEP generally attenuated DPOAEs more for low frequencies than for high frequencies. For the frequencies of 1000 Hz and below, the mean DPOAE level was reduced by at least 4 to 6 dB for negative MEPs lower than −100 daPa (i.e., less negative). Reduction of the DPOAE level increased with increasing negative MEP (e.g., 10 to 12 dB for −160 daPa and higher, i.e., more negative). For f2 = 2000, 4000, and 6000 Hz, the effect of negative MEP was not significant. For 3000 Hz, DPOAE-level reduction was significant (e.g., 5 dB for MEP = −70 to −95 daPa and up to 12 dB for −290 to −420 daPa). As a result, a peak at 2000 Hz and a notch at 3000 Hz appeared in the DPOAE change versus frequency function. For 8000 Hz, DPOAE levels tended to increase in high negative MEPs, although the changes were not significant. Intersubject variability in the effect of negative MEP on DPOAEs was large. As the negative MEPs were compensated for, the decreased DPOAE levels were significantly corrected. DPOAEs measured with higher resolution in experiment 2 verified the frequency-specific effects of negative MEPs. Results revealed that the peak and notch in the DPOAE change versus frequency function shifted toward higher frequencies when negative MEP was increased, and a second peak emerged at a higher frequency. Conclusions: Negative MEP substantially decreases DPOAE level for low frequencies and some mid-frequencies but tends to increase DPOAE level for high frequencies. Results suggest that any degree of negative MEP should be corrected to obtain an accurate outcome of DPOAE measurement. The MEP compensation procedure is effective in restoring normal DPOAEs in ears with negative MEPs. Examining changes in DPOAE level under negative MEP allows for further study of the transmission of acoustic signals through an altered middle ear system. A minimal change of DPOAE level at 2000 Hz indicates that the primary resonant frequency of the middle ear is lower than 2000 Hz. The variation in DPOAE change in the middle to high frequency range implies multiple resonances of the middle ear system.
- 1 June 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (6) , 4310-4320
Distortion product otoacoustic emission fine structure is responsible for variability of distortion product otoacoustic emission contralateral suppression
Alteration of the distortion product otoacoustic emission (DPOAE) level by a contralateral sound, which is known as DPOAE contralateral suppression, has been attributed to the feedback mechanism of the medial olivocochlear efferents. However, the limited dynamic range and large intra- and intersubject variabilities in the outcome of the measurement restrict its application in assessing the efferent function. In this study, the 2f1−f2 DPgram was measured with a high frequency resolution in six human ears, which exhibits a fine structure with the quasiperiodic appearance of peaks and dips. In the presence of contralateral noise, the DPOAE level increased, decreased, or remained unchanged depending on the frequency. At the peaks, DPOAEs were mostly suppressed with a larger change, while those at the dips had greater variance, with increased occurrence of enhancement or no change. The difference between the peak and dip frequencies in the DPOAE-level change was significant. A switch from suppression to enhancement of the DPOAE level or vice versa with a small change in frequency was noted. These results imply that the DPOAE fine structure is a main source of the variability in DPOAE contralateral suppression measurement. The study suggests that the DPOAE contralateral suppression test would be improved if it is conducted for frequencies at major peaks of the DPOAE fine structure.
- 1 June 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (6) , 4310-4320
Distortion product otoacoustic emission fine structure is responsible for variability of distortion product otoacoustic emission contralateral suppression
Alteration of the distortion product otoacoustic emission (DPOAE) level by a contralateral sound, which is known as DPOAE contralateral suppression, has been attributed to the feedback mechanism of the medial olivocochlear efferents. However, the limited dynamic range and large intra- and intersubject variabilities in the outcome of the measurement restrict its application in assessing the efferent function. In this study, the 2f1−f2 DPgram was measured with a high frequency resolution in six human ears, which exhibits a fine structure with the quasiperiodic appearance of peaks and dips. In the presence of contralateral noise, the DPOAE level increased, decreased, or remained unchanged depending on the frequency. At the peaks, DPOAEs were mostly suppressed with a larger change, while those at the dips had greater variance, with increased occurrence of enhancement or no change. The difference between the peak and dip frequencies in the DPOAE-level change was significant. A switch from suppression to enhancement of the DPOAE level or vice versa with a small change in frequency was noted. These results imply that the DPOAE fine structure is a main source of the variability in DPOAE contralateral suppression measurement. The study suggests that the DPOAE contralateral suppression test would be improved if it is conducted for frequencies at major peaks of the DPOAE fine structure.
- 31 March 2008
- Published by Elsevier in Hearing Research
- Vol. 237 (1-2) , 66-75
Contralateral suppression of distortion product otoacoustic emissions and the middle-ear muscle reflex in human ears
- 31 March 2008
- Published by Elsevier in Hearing Research
- Vol. 237 (1-2) , 66-75
Contralateral suppression of distortion product otoacoustic emissions and the middle-ear muscle reflex in human ears
- 1 January 2007
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 46 (4) , 187-195
Contralateral suppression of distortion product otoacoustic emissions: Effect of the primary frequency in Dpgrams
The amplitude of the 2f1–f2 distortion product otoacoustic emission (DPOAE) can be suppressed by presenting contralateral acoustic stimulation. To test the hypothesis that DPOAE contralateral suppression is influenced by the primary frequency in DPgrams, DPgrams were recorded at resolutions of 1, 8, and 17 pts/octave, in the absence and presence of contralateral broadband noise (BBN). Participants were 20 normal-hearing human adults. In DPgrams with higher frequency resolutions, DPOAE suppression at amplitude peaks in DPgrams (8 pts/octave: Mean = − 0.92 dB, SD = 0.71 for BBN at 60 dB SPL; 17 pts/octave: Mean = − 0.25 to −1.44 dB, SD = 0.51 to 0.86 for BBN at 40 to 70 dB SPL, respectively) was larger than the suppression at the dips in DPgrams (8 pts/octave: Mean = − 0.13 dB, SD = 1.00; 17 pts/octave: Mean = − 0.03 to −0.73 dB, SD = 0.55 to 0.91). A larger intersubject variability in DPOAE contralateral suppression was observed at the dips. The results suggest that measuring DPOAE contralateral suppression at the primary frequencies corresponding to the peaks in DPgrams with higher frequency resolutions may improve the assessment of the efferent system function.
- 1 January 2007
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 46 (4) , 187-195
Contralateral suppression of distortion product otoacoustic emissions: Effect of the primary frequency in Dpgrams
The amplitude of the 2f1–f2 distortion product otoacoustic emission (DPOAE) can be suppressed by presenting contralateral acoustic stimulation. To test the hypothesis that DPOAE contralateral suppression is influenced by the primary frequency in DPgrams, DPgrams were recorded at resolutions of 1, 8, and 17 pts/octave, in the absence and presence of contralateral broadband noise (BBN). Participants were 20 normal-hearing human adults. In DPgrams with higher frequency resolutions, DPOAE suppression at amplitude peaks in DPgrams (8 pts/octave: Mean = − 0.92 dB, SD = 0.71 for BBN at 60 dB SPL; 17 pts/octave: Mean = − 0.25 to −1.44 dB, SD = 0.51 to 0.86 for BBN at 40 to 70 dB SPL, respectively) was larger than the suppression at the dips in DPgrams (8 pts/octave: Mean = − 0.13 dB, SD = 1.00; 17 pts/octave: Mean = − 0.03 to −0.73 dB, SD = 0.55 to 0.91). A larger intersubject variability in DPOAE contralateral suppression was observed at the dips. The results suggest that measuring DPOAE contralateral suppression at the primary frequencies corresponding to the peaks in DPgrams with higher frequency resolutions may improve the assessment of the efferent system function.