PMPeter Morten Moselund

Peter Morten Moselund

*This is an algorithmically generated author record based on publicly available information.

Peter Morten Moselund has a total of 128 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Supercontinuum applications in high resolution non invasive optical imaging

    by Adrian Podoleanu, Ole Bang, Sophie Bojesen, Magalie Bondu, Adrian Bradu, Sophie Caujolle, Catherine Chin, Mark Denninger, Thomas Feuchter, Felix Fleischhauer, et al.

    Progress will be presented in adapting supercontinuum sources to a variety of applications with emphasis on signal processing procedures. These are customised to alleviate noise and take full advantage of the large bandwidth and large power spectral density of modern supercontinuum sources.


  • High Pulse Energy Supercontinuum Laser for Photoacoustic Detection and Identification of Lipids in the 1650–1850 nm Wavelength Region

    by Manoj Kumar Dasa, Christos Markos, Michael Maria, Ivan B. Gonzalo, Christian R. Petersen, Deepak Jain, Peter M. Moselund, Ole Bang

    Lipids are highly coveted for the interrogation of fatal chronic diseases. We propose cost-efficient high pulse energy supercontinuum source, using telecom range diode laser and standard optical fiber for photoacoustic detection and identification of lipids.

  • Open Access

    Record power, ultra-broadband supercontinuum source based on highly GeO_2 doped silica fiber

    by D. Jain, R. Sidharthan, P. M. Moselund, S. Yoo, D. Ho, O. Bang

    We demonstrate highly germania doped fibers for mid-infrared supercontinuum generation. Experiments ensure a highest output power of 1.44 W for a broadest spectrum from 700 nm to 3200 nm and 6.4 W for 800 nm to 2700 nm from these fibers, while being pumped by a broadband Erbium-Ytterbium doped fiber based master oscillator power amplifier. The effect of repetition frequency of pump source and length of germania-doped fiber has also been investigated. Further, germania doped fiber has been pumped by conventional supercontinuum source based on silica photonic crystal fiber supercontinuum source. At low power, a considerable broadening of 200-300 nm was observed. Further broadening of spectrum was limited due to limited power of pump source. Our investigations reveal the unexploited potential of germania doped fiber for mid-infrared supercontinuum generation. These measurements ensure the potential of germania based photonic crystal fiber or a step-index fiber supercontinuum source for high power ultra-broad band emission being by pumped a 1060 nm or a 1550 nm laser source. To the best of our knowledge, this is the record power, ultra-broadband, and all-fiberized supercontinuum light source based on silica and germania fiber ever demonstrated to the date.


  • Acousto-optic tunable filter for dispersion characterization of time-domain optical coherence tomography systems

    by Catherine Chin, Florin Toadere, Thomas Feuchter, Lasse Leick, Peter Moselund, Adrian Bradu, Adrian Podoleanu

    A broadband supercontinuum light source with an acousto-optic tunable filter (AOTF) are used to characterize dispersion in two time-domain OCT systems, at 850 and 1300 nm. The filter is designed to sweep across two spectral ranges, which are restricted here from 800 to 900 nm and from 1200 to 1500 nm, respectively. Dispersion compensation for 850 nm was achieved with a spectral delay line. Dispersion compensation for 1300 nm was achieved using BK 7 rod glasses in the reference arm. The AOTF allows evaluation of dispersion in under as well as overcompensated systems. The AOTF method is based on wavelength dependence of the optical path difference corresponding to the maximum strength of the interference signal recorded using a mirror as object. Comparison is made between the AOTF method and the more usual method based on measurement of the full width at half-maximum of the autocorrelation peak. This comparison shows that the AOTF method is more accurate in terms of evaluation of the dispersion left uncompensated after each adjustment. The AOTF method additionally provides information on the direction of dispersion compensation.


  • Open Access

    Upconversion imaging using an all-fiber supercontinuum source

    by Laurent Huot, Peter Morten Moselund, Peter Tidemand-Lichtenberg, Lasse Leick, Christian Pedersen

    In this Letter, the first demonstration, to the best of our knowledge, of pulsed upconversion imaging using supercontinuum light is presented. A mid-infrared (IR) imaging system was built by combining a mid-IR supercontinuum source emitting between 1.8 and 2.6 μm with upconversion detection. The infrared signal is used to probe a sample and mixed with a synchronized 1550 nm laser pulse inside a lithium niobate (LiNbO3) crystal. The signal is thus upconverted to the 860–970 nm range and acquired on a standard silicon CCD array at a rate of 22 frames per second. In our implementation, spatial features in the sample plane as small as 55 μm could be resolved.


  • Application of supercontinuum radiation for mid-infrared spectroscopy

    by Jakob Kilgus, Petra Müller, Peter M. Moselund, Markus Brandstetter


  • All-fiber mid-IR supercontinuum: a powerful new tool for IR-spectroscopy

    by Peter M. Moselund, Laurent Huot, Chris D. Brooks


  • Mid-IR supercontinuum generation beyond 7 μm using a silica-fluoride-chalcogenide fiber cascade

    by Christian R. Petersen, Peter M. Moselund, Uffe Møller, Ole Bang

    We report on an experimental demonstration of mid-infrared cascaded supercontinuum generation in commercial silica, fluoride, and chalcogenide fibers as a potentially cheap and practical alternative to direct pumping schemes. A pump continuum up to 4.4 μm was generated in cascaded silica and fluoride fibers by an amplified 1.55 μm nanosecond diode laser. By pumping a commercial Ge10As22Se68 single-material photonic crystal fiber with 135.7 mW of the pump continuum from 3.5- 4.4 μm, we obtained a continuum up to 7.2 μm with a total output power after the collimating lens of 54.5 mW, and 3.7 mW above 4.5 μm.


  • Towards supercontinuum-driven hyperspectral microscopy in the mid-infrared

    by I. D. Lindsay, S. Valle, J. Ward, G. Stevens, M. Farries, L. Huot, C. Brooks, P. M. Moselund, R. M. Vinella, M. Abdalla, et al.

    The extension of supercontinuum (SC) sources into the mid-infrared, via the use of uoride and chalcogenide optical fibers, potentially offers the high radiance of a laser combined with spectral coverage far exceeding that of typical tunable lasers and comparable to traditional black-body emitters. Together with advances in mid-IR imaging detectors and novel tunable filter designs, such supercontinua hold considerable potential as sources of illumination for spectrally-resolved microscopy targeting applications such as rapid histological screening. The ability to rapidly and arbitrarily select particular wavelengths of interest from a broad emission spectrum, covering a wide range of biologically relevant targets, lends itself to image acquisition only at key relevant wavelengths leading to more manageable datasets. However, in addition to offering new imaging modalities, SC sources also present a range of challenges to successful integration with typical spectral microscopy instrumentation, including appropriate utilisation of their high spatial coherence. In this paper the application of SC sources to spectrally-resolved microscopy in the mid-IR is discussed and systems-integration considerations specific to these sources highlighted. Preliminary results in the 3-5μm region, obtained within the European FP7 project MINERVA, are also presented here.


  • Towards the mid-infrared optical biopsy

    by Angela B. Seddon, Trevor M. Benson, Slawomir Sujecki, Nabil Abdel-Moneim, Zhuoqi Tang, David Furniss, Lukasz Sojka, Nick Stone, Nallala Jayakrupakar, Gavin Rhys Lloyd, et al.

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the midinfrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy (‘opsy’ look at, bio the biology) in situ in the body for real-time diagnosis. This new paradigm will be enabled through focused development of devices and systems which are robust, functionally designed, safe, compact and cost effective and are based on active and passive mid-infrared optical fibers. In particular, this will enable early diagnosis of external cancers, mid-infrared detection of cancer-margins during external surgery for precise removal of diseased tissue, in one go during the surgery, and mid-infrared endoscopy for early diagnosis of internal cancers and their precision removal. The mid-infrared spectral region has previously lacked portable, bright sources. We set a record in demonstrating extreme broad-band supercontinuum generated light 1.4 to 13.3 microns in a specially engineered, high numerical aperture mid-infrared optical fiber. The active mid-infrared fiber broadband supercontinuum for the first time offers the possibility of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security, agriculture and in manufacturing and chemical processing. This work is in part supported by the European Commission: Framework Seven (FP7) Large-Scale Integrated Project MINERVA: MId-to-NEaR- infrared spectroscopy for improVed medical diAgnostics (317803; www.minerva-project.eu).