Haoming Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haoming Lin has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Xin Chen
College of Art and Design, Division of Arts, Shenzhen University
10 shared publications Siping Chen
9 shared publications- Mian Chen
Shenzhen University Medical School, Shenzhen University
7 shared publications - Tong Sun
National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, China
5 shared publications Dingqian Deng
3 shared publications- Dingqian Deng
National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, China
3 shared publications
Latest Publications
- 16 November 2026
- Published by Elsevier in Ultrasonics
- Vol. 172
Mean-shift-based spatiotemporal microbubble signal enhancement for high-concentration ultrasound localization microscopy
- 16 November 2026
- Published by Elsevier in Ultrasonics
- Vol. 172
Mean-shift-based spatiotemporal microbubble signal enhancement for high-concentration ultrasound localization microscopy
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73  (10) , 3349-3359
SW-VEI-Net: A Physics-Informed Deep Neural Network for Shear Wave Viscoelasticity Imaging
Quantitative viscoelasticity imaging via shear wave elastography (SWE) remains challenging due to complex wave physics and limitations of conventional reconstruction methods. To address this, we present SW-VEI-Net, a physics-informed neural network (PINN) that simultaneously reconstructs the shear elastic modulus and viscous modulus by integrating viscoelastic wave equations into a dual-network architecture. The framework employs a dual-loss function to balance data fidelity and physics-based regularization, significantly reducing reliance on empirical data while improving interpretability. Extensive validation on tissue-mimicking phantoms, rat liver fibrosis model, and clinical cases demonstrates that SW-VEI-Net outperforms state-of-the-art SWE methods. Compared to SWENet (a PINN-based method using a linear elastic model), SW-VEI-Net not only enables simultaneous assessment of shear elastic and viscous moduli, but also achieves higher accuracy in shear elastic modulus reconstruction. Furthermore, when benchmarked against the dispersion fitting (DF) method (based on a viscoelastic model), SW-VEI-Net produces comparable viscoelastic parameter maps while exhibiting enhanced robustness and consistency. For liver fibrosis staging, SW-VEI-Net achieves AUC values of 0.85 ($\geq$F2) and 0.91 ($=$F4) based on elastic modulus classification, surpassing both SWENet (0.84, 0.85) and DF (0.78, 0.88). Additional validation in healthy volunteers shows strong agreement with a commercial ultrasound system. By synergizing deep learning with fundamental wave physics, this study represents a significant advancement in SWE, offering substantial clinical potential for early detection of hepatic fibrosis and malignant lesions through precise viscoelastic biomarker mapping.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73  (10) , 3349-3359
SW-VEI-Net: A Physics-Informed Deep Neural Network for Shear Wave Viscoelasticity Imaging
Quantitative viscoelasticity imaging via shear wave elastography (SWE) remains challenging due to complex wave physics and limitations of conventional reconstruction methods. To address this, we present SW-VEI-Net, a physics-informed neural network (PINN) that simultaneously reconstructs the shear elastic modulus and viscous modulus by integrating viscoelastic wave equations into a dual-network architecture. The framework employs a dual-loss function to balance data fidelity and physics-based regularization, significantly reducing reliance on empirical data while improving interpretability. Extensive validation on tissue-mimicking phantoms, rat liver fibrosis model, and clinical cases demonstrates that SW-VEI-Net outperforms state-of-the-art SWE methods. Compared to SWENet (a PINN-based method using a linear elastic model), SW-VEI-Net not only enables simultaneous assessment of shear elastic and viscous moduli, but also achieves higher accuracy in shear elastic modulus reconstruction. Furthermore, when benchmarked against the dispersion fitting (DF) method (based on a viscoelastic model), SW-VEI-Net produces comparable viscoelastic parameter maps while exhibiting enhanced robustness and consistency. For liver fibrosis staging, SW-VEI-Net achieves AUC values of 0.85 ($\geq$F2) and 0.91 ($=$F4) based on elastic modulus classification, surpassing both SWENet (0.84, 0.85) and DF (0.78, 0.88). Additional validation in healthy volunteers shows strong agreement with a commercial ultrasound system. By synergizing deep learning with fundamental wave physics, this study represents a significant advancement in SWE, offering substantial clinical potential for early detection of hepatic fibrosis and malignant lesions through precise viscoelastic biomarker mapping.
- 24 July 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 203, 467-477
Non-invasive longitudinal monitoring of vascularization in tissue-engineered grafts by ultrasound localization microscopy
- 24 July 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 203, 467-477
Non-invasive longitudinal monitoring of vascularization in tissue-engineered grafts by ultrasound localization microscopy
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-15
A Novel Model-Based Conductivity Reconstruction in Magneto-Acousto-Electrical Tomography (MAET): Simulation and Experiment Study
Magneto-acousto-electrical tomography (MAET), which combines ultrasound imaging with electrical impedance tomography, offers high resolution and high contrast for mapping the internal conductivity distribution of an object. However, it is a challenge to reconstruct the conductivity distribution containing the interior information due to practical system constraints. A significant issue is the limited bandwidth of experimental systems, especially the ultrasound transducer, which can filter out low-frequency components of the measurement signal. Inspired by the multi-compartment model paradigm in diffusion MRI, we propose an innovative model-based approach to address this conductivity reconstruction challenge. The object’s conductivity is constrained by the weighted sum of shifted jump models, dramatically reducing the problem’s degrees of freedom. By deriving the measurement signal based on the proposed model, we can extract the conductivity polarity using an overdetermined linear system solved by the least-squares method. Furthermore, by integrating amplitude information from conventional conductivity parameter images with the extracted conductivity polarity, we reconstruct the final relative conductivity distribution. Our methodology has been rigorously tested through numerical simulations with various noise levels (20%, 40%, and 60%), phantom experiments, and pork tissue comparisons against the state-of-the-art method. The results demonstrate that our method offers superior accuracy and stability compared to existing techniques in case of all evaluation metrics RMSE, SSIM, PSNR. In conclusion, our proposed method is straightforward to implement and applicable in both simulations and practical experiments, providing a potential strategy for conductivity reconstruction in complex objects in the future.
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-15
A Novel Model-Based Conductivity Reconstruction in Magneto-Acousto-Electrical Tomography (MAET): Simulation and Experiment Study
Magneto-acousto-electrical tomography (MAET), which combines ultrasound imaging with electrical impedance tomography, offers high resolution and high contrast for mapping the internal conductivity distribution of an object. However, it is a challenge to reconstruct the conductivity distribution containing the interior information due to practical system constraints. A significant issue is the limited bandwidth of experimental systems, especially the ultrasound transducer, which can filter out low-frequency components of the measurement signal. Inspired by the multi-compartment model paradigm in diffusion MRI, we propose an innovative model-based approach to address this conductivity reconstruction challenge. The object’s conductivity is constrained by the weighted sum of shifted jump models, dramatically reducing the problem’s degrees of freedom. By deriving the measurement signal based on the proposed model, we can extract the conductivity polarity using an overdetermined linear system solved by the least-squares method. Furthermore, by integrating amplitude information from conventional conductivity parameter images with the extracted conductivity polarity, we reconstruct the final relative conductivity distribution. Our methodology has been rigorously tested through numerical simulations with various noise levels (20%, 40%, and 60%), phantom experiments, and pork tissue comparisons against the state-of-the-art method. The results demonstrate that our method offers superior accuracy and stability compared to existing techniques in case of all evaluation metrics RMSE, SSIM, PSNR. In conclusion, our proposed method is straightforward to implement and applicable in both simulations and practical experiments, providing a potential strategy for conductivity reconstruction in complex objects in the future.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71  (11) , 3244-3251
Three-Dimensional Magneto-Acousto-Electrical Computed Tomography (3D MAE-CT): A Preliminary Study Using Ultrasound Linear Array Transducer
Magneto-acousto-electrical tomography (MAET) is a hybrid imaging method that combines the high spatial resolution of ultrasonography with the high contrast of electrical impedance tomography (EIT). While most previous studies on MAET have focused on two-dimensional imaging, our recent research proposed a novel three-dimensional (3D) MAET method using B-mode and translational scanning. This method has been the first to reconstruct a 3D volume image of conductivity interfaces. However, this method has its limitations in mapping irregular shapes of conductivity. To address this challenge, we propose a 3D magneto-acousto-electrical computed tomography (3D MAE-CT) method utilizing an ultrasound linear array transducer in this work. Both phantom and in vitro experiments were conducted to validate our proposed method. The results from the phantom experiments demonstrate that our method can map the 3D volume conductivity with high spatial resolution. The oblique angles extracted from the 3D image closely match practical value, with the relative error ranging between −2.80% and 4.07%. Furthermore, the in vitro experiment successfully obtained a 3D image of a chicken heart, marking the first MAET 3D conductivity image of a tissue sample to date.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71  (11) , 3244-3251
Three-Dimensional Magneto-Acousto-Electrical Computed Tomography (3D MAE-CT): A Preliminary Study Using Ultrasound Linear Array Transducer
Magneto-acousto-electrical tomography (MAET) is a hybrid imaging method that combines the high spatial resolution of ultrasonography with the high contrast of electrical impedance tomography (EIT). While most previous studies on MAET have focused on two-dimensional imaging, our recent research proposed a novel three-dimensional (3D) MAET method using B-mode and translational scanning. This method has been the first to reconstruct a 3D volume image of conductivity interfaces. However, this method has its limitations in mapping irregular shapes of conductivity. To address this challenge, we propose a 3D magneto-acousto-electrical computed tomography (3D MAE-CT) method utilizing an ultrasound linear array transducer in this work. Both phantom and in vitro experiments were conducted to validate our proposed method. The results from the phantom experiments demonstrate that our method can map the 3D volume conductivity with high spatial resolution. The oblique angles extracted from the 3D image closely match practical value, with the relative error ranging between −2.80% and 4.07%. Furthermore, the in vitro experiment successfully obtained a 3D image of a chicken heart, marking the first MAET 3D conductivity image of a tissue sample to date.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71  (2) , 669-678
Iterative Reconstruction Algorithms in Magneto-Acousto-Electrical Computed Tomography (MAE-CT) for Image Quality Improvement
Magneto-acousto-electrical computed tomography (MAE-CT) is a recently developed rotational magneto-acousto-electrical tomography (MAET) method, which can map the conductivity parameter of tissues with high spatial resolution. Since the imaging mode of MAE-CT is similar to that of CT, the reconstruction algorithms for CT are possible to be adopted for MAE-CT. Previous studies have demonstrated that the filtered back-projection (FBP) algorithm, which is one of the most common CT reconstruction algorithms, can be used for MAE-CT reconstruction. However, FBP has some inherent shortcomings of being sensitive to noise and non-uniform distribution of views. In this study, we introduced iterative reconstruction (IR) method in MAE-CT reconstruction and compared its performance with that of the FBP. The numerical simulation, the phantom, and in vitro experiments were performed, and several IR algorithms (ART, SART, SIRT) were used for reconstruction. The results show that the images reconstructed by the FBP and IR are similar when the data is noise-free in the simulation. As the noise level increases, the images reconstructed by SART and SIRT are more robust to the noise than FBP. In the phantom experiment, noise and some stripe artifacts caused by the FBP are removed by SART and SIRT algorithms. In conclusion, the IR method used in CT is applicable in MAE-CT, and it performs better than FBP, which indicates that the state-of-the-art achievements in the CT algorithm can also be adopted for the MAE-CT reconstruction in the future.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71  (2) , 669-678
Iterative Reconstruction Algorithms in Magneto-Acousto-Electrical Computed Tomography (MAE-CT) for Image Quality Improvement
Magneto-acousto-electrical computed tomography (MAE-CT) is a recently developed rotational magneto-acousto-electrical tomography (MAET) method, which can map the conductivity parameter of tissues with high spatial resolution. Since the imaging mode of MAE-CT is similar to that of CT, the reconstruction algorithms for CT are possible to be adopted for MAE-CT. Previous studies have demonstrated that the filtered back-projection (FBP) algorithm, which is one of the most common CT reconstruction algorithms, can be used for MAE-CT reconstruction. However, FBP has some inherent shortcomings of being sensitive to noise and non-uniform distribution of views. In this study, we introduced iterative reconstruction (IR) method in MAE-CT reconstruction and compared its performance with that of the FBP. The numerical simulation, the phantom, and in vitro experiments were performed, and several IR algorithms (ART, SART, SIRT) were used for reconstruction. The results show that the images reconstructed by the FBP and IR are similar when the data is noise-free in the simulation. As the noise level increases, the images reconstructed by SART and SIRT are more robust to the noise than FBP. In the phantom experiment, noise and some stripe artifacts caused by the FBP are removed by SART and SIRT algorithms. In conclusion, the IR method used in CT is applicable in MAE-CT, and it performs better than FBP, which indicates that the state-of-the-art achievements in the CT algorithm can also be adopted for the MAE-CT reconstruction in the future.
- 20 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27  (10) , 4938-4949
Automatic Diagnosis of Significant Liver Fibrosis From Ultrasound B-Mode Images Using a Handcrafted-Feature-Assisted Deep Convolutional Neural Network
The accurate diagnosis of significant liver fibrosis ( $\rm \geq$ F2) in patients with chronic liver disease (CLD) is critical, as $\pmb \mathrm{\geq }$ F2 is a crucial factor that should be considered in selecting an antiviral therapy for these patients. This paper proposes a handcrafted-feature-assisted deep convolutional neural network (HFA-DCNN) that helps pathologists automatically and accurately diagnose significant liver fibrosis from ultrasound (US) brightness (B)-mode images. The HFA-DCNN model has three main branches: one for automatic region of interest (ROI) segmentation in the US images, another for attention deep feature learning from the segmented ROI, and the third for handcrafted feature extraction. The attention deep learning features and handcrafted features are fused in the back end of the model to enable more accurate diagnosis of significant liver fibrosis. The usefulness and effectiveness of the proposed model were validated on a dataset built upon 321 CLD patients with liver fibrosis stages confirmed by pathological evaluations. In a fivefold cross validation (FFCV), the proposed model achieves accuracy, sensitivity, specificity, and area under the receiver-operating-characteristic (ROC) curve (AUC) values of 0.863 (95% confidence interval (CI) 0.820–0.899), 0.879 (95% CI 0.823–0.920), 0.872 (95% CI 0.800–0.925), and 0.925 (95% CI 0.891–0.952), which are significantly better than those obtained by the comparative methods. Given its excellent performance, the proposed HFA-DCNN model can serve as a promising tool for the noninvasive and accurate diagnosis of significant liver fibrosis in CLD patients.
- 20 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27  (10) , 4938-4949
Automatic Diagnosis of Significant Liver Fibrosis From Ultrasound B-Mode Images Using a Handcrafted-Feature-Assisted Deep Convolutional Neural Network
The accurate diagnosis of significant liver fibrosis ( $\rm \geq$ F2) in patients with chronic liver disease (CLD) is critical, as $\pmb \mathrm{\geq }$ F2 is a crucial factor that should be considered in selecting an antiviral therapy for these patients. This paper proposes a handcrafted-feature-assisted deep convolutional neural network (HFA-DCNN) that helps pathologists automatically and accurately diagnose significant liver fibrosis from ultrasound (US) brightness (B)-mode images. The HFA-DCNN model has three main branches: one for automatic region of interest (ROI) segmentation in the US images, another for attention deep feature learning from the segmented ROI, and the third for handcrafted feature extraction. The attention deep learning features and handcrafted features are fused in the back end of the model to enable more accurate diagnosis of significant liver fibrosis. The usefulness and effectiveness of the proposed model were validated on a dataset built upon 321 CLD patients with liver fibrosis stages confirmed by pathological evaluations. In a fivefold cross validation (FFCV), the proposed model achieves accuracy, sensitivity, specificity, and area under the receiver-operating-characteristic (ROC) curve (AUC) values of 0.863 (95% confidence interval (CI) 0.820–0.899), 0.879 (95% CI 0.823–0.920), 0.872 (95% CI 0.800–0.925), and 0.925 (95% CI 0.891–0.952), which are significantly better than those obtained by the comparative methods. Given its excellent performance, the proposed HFA-DCNN model can serve as a promising tool for the noninvasive and accurate diagnosis of significant liver fibrosis in CLD patients.
- 11 March 2023
- Published by Elsevier in Neurocomputing
- Vol. 536, 80-89
Three-dimensional magneto-acousto-electrical tomography (3D MAET) with single-element ultrasound transducer and coded excitation: A phantom validation study
- 11 March 2023
- Published by Elsevier in Neurocomputing
- Vol. 536, 80-89
Three-dimensional magneto-acousto-electrical tomography (3D MAET) with single-element ultrasound transducer and coded excitation: A phantom validation study
- 7 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70  (6) , 1758-1767
Magnetomotive Ultrasound Shear Wave Elastography (MMUS-SWE): A Validation Study From Simulations to Experiments
Ultrasound elastography is a functional imaging method that enables the measurement of soft tissue elasticity, which is associated with the pathological process of many diseases. However, the measurement area of the conventional elastography method is subjectively selected. Inspired by the targeted imaging technology, we propose a method of magnetomotive ultrasound shear wave elastography (MMUS-SWE). This method utilizes the magnetic force between the magnetic nanoparticles (MNPs) and the external magnetic field to generate shear waves. Then, it can detect the distribution of MNPs and the elasticity of the tissue around the MNPs. As MNPs have been widely used for targeted labeling, the strategy to induce local vibration by MNPs will be more specific than that of the conventional SWE. In this study, the theoretical feasibility was verified by the finite element simulation model. Then, an experimental system was built, and the experimental feasibility of the method was demonstrated through phantom experiments, in vitro tissue experiments, and in vivo experiments. The results show that the distribution of the MNPs and the elastic information of tissues surrounding the MNPs can be detected simultaneously. This technology is expected to realize targeted elasticity measurement based on the MNPs and has potential applications for disease diagnosis.
- 7 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70  (6) , 1758-1767
Magnetomotive Ultrasound Shear Wave Elastography (MMUS-SWE): A Validation Study From Simulations to Experiments
Ultrasound elastography is a functional imaging method that enables the measurement of soft tissue elasticity, which is associated with the pathological process of many diseases. However, the measurement area of the conventional elastography method is subjectively selected. Inspired by the targeted imaging technology, we propose a method of magnetomotive ultrasound shear wave elastography (MMUS-SWE). This method utilizes the magnetic force between the magnetic nanoparticles (MNPs) and the external magnetic field to generate shear waves. Then, it can detect the distribution of MNPs and the elasticity of the tissue around the MNPs. As MNPs have been widely used for targeted labeling, the strategy to induce local vibration by MNPs will be more specific than that of the conventional SWE. In this study, the theoretical feasibility was verified by the finite element simulation model. Then, an experimental system was built, and the experimental feasibility of the method was demonstrated through phantom experiments, in vitro tissue experiments, and in vivo experiments. The results show that the distribution of the MNPs and the elastic information of tissues surrounding the MNPs can be detected simultaneously. This technology is expected to realize targeted elasticity measurement based on the MNPs and has potential applications for disease diagnosis.
- 8 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70  (5) , 1493-1503
Improved Magneto-Acousto-Electrical Computed Tomography (MAE-CT) With Multi-Angle Plane Wave Excitation
As a tissue conductivity imaging method, magneto-acousto-electric tomography (MAET) has the advantage of high axial spatial resolution compared with traditional electrical impedance imaging methods. However, it has the problems of difficulty in imaging targets with irregular conductivity distribution and poor lateral spatial resolution. Although the rotation-based MAET method can partly solve the irregular target problem, there is still a poor imaging signal-to-noise ratio (SNR) problem. Our previous study established a framework of an innovative MAET method, which has a very similar imaging theory and reconstruction algorithm to those of computed tomography (CT). Therefore, we name the method magneto-acoustic-electric computed tomography (MAE-CT). This paper proposes an improved implementation of MAE-CT based on multi-angle plane wave excitation. This method combines the electronic steering of the linear array transducer with the mechanical rotation to increase the number of projection angles while keeping the imaging complexity. In this study, we first established a finite element simulation model to verify the method's feasibility. Then phantom experiments were conducted to systematically investigate the performance of the proposed method. Finally, in vitro liver tissue experiment was conducted to further explore the feasibility of the method. The experimental results show that our method improves both the SNR and spatial resolution of the reconstructed image. For the phantom results, this method can detect conductivity of 0.67 S/m in an area with a size of 2 mm. To the best of our knowledge, this is the best result of spatial resolution available for MAET.
- 8 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70  (5) , 1493-1503
Improved Magneto-Acousto-Electrical Computed Tomography (MAE-CT) With Multi-Angle Plane Wave Excitation
As a tissue conductivity imaging method, magneto-acousto-electric tomography (MAET) has the advantage of high axial spatial resolution compared with traditional electrical impedance imaging methods. However, it has the problems of difficulty in imaging targets with irregular conductivity distribution and poor lateral spatial resolution. Although the rotation-based MAET method can partly solve the irregular target problem, there is still a poor imaging signal-to-noise ratio (SNR) problem. Our previous study established a framework of an innovative MAET method, which has a very similar imaging theory and reconstruction algorithm to those of computed tomography (CT). Therefore, we name the method magneto-acoustic-electric computed tomography (MAE-CT). This paper proposes an improved implementation of MAE-CT based on multi-angle plane wave excitation. This method combines the electronic steering of the linear array transducer with the mechanical rotation to increase the number of projection angles while keeping the imaging complexity. In this study, we first established a finite element simulation model to verify the method's feasibility. Then phantom experiments were conducted to systematically investigate the performance of the proposed method. Finally, in vitro liver tissue experiment was conducted to further explore the feasibility of the method. The experimental results show that our method improves both the SNR and spatial resolution of the reconstructed image. For the phantom results, this method can detect conductivity of 0.67 S/m in an area with a size of 2 mm. To the best of our knowledge, this is the best result of spatial resolution available for MAET.