Sara Dehdashtian
Research Subjects
Sara Dehdashtian has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Beshare Hashemi
Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul, 04763 Republic of Korea
3 shared publicationsMahdieh Chegeni
Department of Chemistry, Faculty of Science, Ayatollah Boroujerdi University, Boroujerd, Iran
2 shared publicationsMojtaba Shamsipur
Department of Chemistry, Razi University, Kermanshah, Iran
2 shared publicationsAmin Aeenmehr
Faculty of Engineering, Shohadaye Hoveizeh University of Technology, Susangerd, Iran
1 shared publicationAzadeh Azadbakht
Department of Chemistry, Khorramabad Branch, Islamic Azad University, Khorramabad, Iran
1 shared publicationKosar Mohammadi Taherzadeh
Department of Chemistry, Islamic Azad University, Omidiyeh Branch, Omidyieh, Iran
1 shared publication
Latest Publications
- Open Access
- 2 March 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (3) , 82
A Comprehensive Study of P-g-C3N4/MOF-199 Composite for Electrochemical Sensing of Metformin in Pharmaceutical Samples
A novel electrochemical sensor (P-g-C3N4/MOF-199/CPE) was developed to determine the metformin concentration in pharmaceutical samples. In this sensor, the copper units of MOF-199 of the composite electrode specifically capture metformin molecules so that the sensing selectivity is remarkably improved. Phosphorus-doped graphitic carbon nitrides (P-g-C3N4) further enhance the electrical conductivity and sensitivity of the sensor. The physical and chemical properties of these electrode modifiers were first characterized, followed by electrochemical sensing tests of metformin under different scan rates and pH values. A 39-fold increase in the electrooxidation current of metformin was found in this composite electrode when compared to its bare carbon paste counterpart. A limit of detection (LOD) of 0.15 nM was achieved in the linear sensing range of 0.5 to 1200 nM for metformin. The sensor also showed good reliability and recovery when detecting metformin in pharmaceutical samples. For the first time, we addressed the appearance of adsorption-based peaks in the voltammograms of electrochemical sensors for metformin as a common feature when copper ions are incorporated into the electrode structure. The electrochemical mechanism of metformin was also illustrated by highlighting the hydrolysis of oxime. The nature of all pH-dependent anodic and cathodic peaks in our sensing results confirms the proposed mechanism.
- 2 March 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (3) , 82
Open AccessA Comprehensive Study of P-g-C3N4/MOF-199 Composite for Electrochemical Sensing of Metformin in Pharmaceutical Samples
A novel electrochemical sensor (P-g-C3N4/MOF-199/CPE) was developed to determine the metformin concentration in pharmaceutical samples. In this sensor, the copper units of MOF-199 of the composite electrode specifically capture metformin molecules so that the sensing selectivity is remarkably improved. Phosphorus-doped graphitic carbon nitrides (P-g-C3N4) further enhance the electrical conductivity and sensitivity of the sensor. The physical and chemical properties of these electrode modifiers were first characterized, followed by electrochemical sensing tests of metformin under different scan rates and pH values. A 39-fold increase in the electrooxidation current of metformin was found in this composite electrode when compared to its bare carbon paste counterpart. A limit of detection (LOD) of 0.15 nM was achieved in the linear sensing range of 0.5 to 1200 nM for metformin. The sensor also showed good reliability and recovery when detecting metformin in pharmaceutical samples. For the first time, we addressed the appearance of adsorption-based peaks in the voltammograms of electrochemical sensors for metformin as a common feature when copper ions are incorporated into the electrode structure. The electrochemical mechanism of metformin was also illustrated by highlighting the hydrolysis of oxime. The nature of all pH-dependent anodic and cathodic peaks in our sensing results confirms the proposed mechanism.
- Open Access
- 20 October 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Determination of vanillin in different food samples by using SMM/Au@ZIF-67 electrochemical sensor
Vanillin is a popular flavoring agent in many food products. Simple, fast, and reliable quantification of this compound is crucial for the food industry. In this work, we have developed a new electrochemical sensor for accurate detection of vanillin in various real samples. The composite electrode was made of sodium montmorillonite nanoclay (SMM) and gold nanoparticles modified ZIF-67 (Au@ZIF-67), in which SMM contributes to the large adsorption capacity of the analyte, ZIF-67 and SMM supply more sensing active sites, and gold nanoparticles provide high electrical conductivity. The sensing electrode was comprehensively characterized using Brunauer–Emmett–Teller, EDS, XRD, SEM, FTIR, and TEM, and its electrochemical behavior for determination of vanillin including the electrooxidation mechanism of vanillin and different parameters such as scan rate and pH value was investigated. The result revealed that a two electron-two proton process was involved in the electrooxidation of vanillin, which takes place more readily due to the lower potential on the surface of SMM/Au@ZIF-67/carbon paste electrode. The new composite electrode was also more sensitive to vanillin detection with an anodic peak current almost 2.6 times more than that of the bare electrode. A linear sensing concentration range was established between 1 and 1200 nM with a detection limit of 0. 3 nM and a limit of quantitation of 1 nM. For real samples, the sensor demonstrated excellent recovery rates and reliability that was comparable to the standard high-performance liquid chromatography method.
- 20 October 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-11
Open AccessDetermination of vanillin in different food samples by using SMM/Au@ZIF-67 electrochemical sensor
Vanillin is a popular flavoring agent in many food products. Simple, fast, and reliable quantification of this compound is crucial for the food industry. In this work, we have developed a new electrochemical sensor for accurate detection of vanillin in various real samples. The composite electrode was made of sodium montmorillonite nanoclay (SMM) and gold nanoparticles modified ZIF-67 (Au@ZIF-67), in which SMM contributes to the large adsorption capacity of the analyte, ZIF-67 and SMM supply more sensing active sites, and gold nanoparticles provide high electrical conductivity. The sensing electrode was comprehensively characterized using Brunauer–Emmett–Teller, EDS, XRD, SEM, FTIR, and TEM, and its electrochemical behavior for determination of vanillin including the electrooxidation mechanism of vanillin and different parameters such as scan rate and pH value was investigated. The result revealed that a two electron-two proton process was involved in the electrooxidation of vanillin, which takes place more readily due to the lower potential on the surface of SMM/Au@ZIF-67/carbon paste electrode. The new composite electrode was also more sensitive to vanillin detection with an anodic peak current almost 2.6 times more than that of the bare electrode. A linear sensing concentration range was established between 1 and 1200 nM with a detection limit of 0. 3 nM and a limit of quantitation of 1 nM. For real samples, the sensor demonstrated excellent recovery rates and reliability that was comparable to the standard high-performance liquid chromatography method.
- 26 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (24) , 11739-11745
The Application of Perlite/Cobalt Oxide/Reduced Graphene Oxide (PC-rGO)/Metal Organic Framework (MOF) Composite as Electrode Modifier for Direct Sensing of Anticancer Drug Idarubicin
This article shows the voltammetric sensing of idarubicin (ID) using an electrochemical sensor modified by a composite (PC-rGO/MOF-199) consisted of perlite/cobalt oxide/reduced graphene oxide (perlite@CoO@rGO (PC-rGO)) nanocomposite and metal-organic framework MOF-199 (Cu). For the fabrication of the desired sensor (PC-rGO/MOF-199/CPE), the synthesized PC-rGO and MOF-199 were applied as modifier in the body of the carbon paste electrode (CPE). The most important factors that can be effective on the performance of the sensor were surveyed. Differential pulse voltammetry (DPV) was applied for recording the calibration curve. The sensor has a linear response over the 5-1000 nM ID concentration range and a 1.5 nM limit of detection (at an S/N ratio of 3). In addition, this sensor is a beneficial sensor for the determination of ID in the real samples.
- 26 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (24) , 11739-11745
The Application of Perlite/Cobalt Oxide/Reduced Graphene Oxide (PC-rGO)/Metal Organic Framework (MOF) Composite as Electrode Modifier for Direct Sensing of Anticancer Drug Idarubicin
This article shows the voltammetric sensing of idarubicin (ID) using an electrochemical sensor modified by a composite (PC-rGO/MOF-199) consisted of perlite/cobalt oxide/reduced graphene oxide (perlite@CoO@rGO (PC-rGO)) nanocomposite and metal-organic framework MOF-199 (Cu). For the fabrication of the desired sensor (PC-rGO/MOF-199/CPE), the synthesized PC-rGO and MOF-199 were applied as modifier in the body of the carbon paste electrode (CPE). The most important factors that can be effective on the performance of the sensor were surveyed. Differential pulse voltammetry (DPV) was applied for recording the calibration curve. The sensor has a linear response over the 5-1000 nM ID concentration range and a 1.5 nM limit of detection (at an S/N ratio of 3). In addition, this sensor is a beneficial sensor for the determination of ID in the real samples.
- 8 July 2019
- Published by Springer Nature in Chemical Papers
- Vol. 74 (1) , 157-165
Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
- 8 July 2019
- Published by Springer Nature in Chemical Papers
- Vol. 74 (1) , 157-165
Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
- Open Access
- 1 January 2019
- Vol. 1 (1) , 22-28
Development of electrochemical sensor based on multiwall carbon nanotube for determination of anticancer drug idarubicin in biological samples
- 1 January 2019
- Vol. 1 (1) , 22-28
Open AccessDevelopment of electrochemical sensor based on multiwall carbon nanotube for determination of anticancer drug idarubicin in biological samples
- 1 November 2018
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 171, 494-500
Modification of gold surface by electrosynthesized mono aza crown ether substituted catechol-terminated alkane dithiol and its application as a new electrochemical sensor for trace detection of cadmium ions
- 1 November 2018
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 171, 494-500
Modification of gold surface by electrosynthesized mono aza crown ether substituted catechol-terminated alkane dithiol and its application as a new electrochemical sensor for trace detection of cadmium ions
- 30 March 2017
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 14 (8) , 1699-1709
Fabrication of an ultrasensitive electrochemical sensor based on a mesoporous silica material functionalized by copper ion (SBA-15-Cu(II)) modified carbon paste electrode for determination of antibiotic ceftazidime and its application in pharmaceutical and biological samples
- 30 March 2017
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 14 (8) , 1699-1709
Fabrication of an ultrasensitive electrochemical sensor based on a mesoporous silica material functionalized by copper ion (SBA-15-Cu(II)) modified carbon paste electrode for determination of antibiotic ceftazidime and its application in pharmaceutical and biological samples
- 1 October 2016
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
- Vol. 94 (10) , 803-811
Fabrication of a highly sensitive and selective electrochemical sensor based on chitosan-coated Fe3O4 magnetic nanoparticle for determination of antibiotic ciprofloxacin and its application in biological samples
A simple and sensitive sensor has been developed for the electrochemical determination of ciprofloxacin (CF). The proposed sensor was designed by chitosan-coated Fe3O4 magnetic nanoparticle incorporated in the carbon paste electrode (CPE), which provides remarkably improved sensitivity for the electrochemical determination of CF. The proposed sensor was characterized with scanning electron microscopy and electrochemical impedance spectroscopy. Under optimum conditions, the sensor provides two linear differential pulse voltammetry responses in the range of 0.05–6 μmol/L and 6–75 μmol/L for CF with a detection limit of 0.01 μmol/L. The proposed sensor exhibited high sensitivity and good selectivity and was successfully applied for CF determination in serum and urine samples.
- 1 October 2016
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
- Vol. 94 (10) , 803-811
Fabrication of a highly sensitive and selective electrochemical sensor based on chitosan-coated Fe3O4 magnetic nanoparticle for determination of antibiotic ciprofloxacin and its application in biological samples
A simple and sensitive sensor has been developed for the electrochemical determination of ciprofloxacin (CF). The proposed sensor was designed by chitosan-coated Fe3O4 magnetic nanoparticle incorporated in the carbon paste electrode (CPE), which provides remarkably improved sensitivity for the electrochemical determination of CF. The proposed sensor was characterized with scanning electron microscopy and electrochemical impedance spectroscopy. Under optimum conditions, the sensor provides two linear differential pulse voltammetry responses in the range of 0.05–6 μmol/L and 6–75 μmol/L for CF with a detection limit of 0.01 μmol/L. The proposed sensor exhibited high sensitivity and good selectivity and was successfully applied for CF determination in serum and urine samples.