Michael A. Galler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael A. Galler has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Cheol Park
3 shared publications- Mary E. McKnight
The authors are with the National Institute of Standards and Technology, Gaithersburg, Maryland 20899
3 shared publications Steven T Bushby
3 shared publicationsSteven T. Bushby
Leader of the Mechanical Systems and Controls Group at the Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD
3 shared publications- Dale P. Bentz
National Institute of Standards and Technology, Engineering Laboratory, Materials and Structural Systems Division, Stop 8615, 100 Bureau Drive, Gaithersburg, MD 20899-8615, USA
2 shared publications Fern Y. Hunt
National Institute of Standards and Technology
2 shared publications
Latest Publications
- 1 January 2026
- Published by National Institute of Standards and Technology (NIST)
BACnet Device Emulator Users’ Guide
- 1 January 2026
- Published by National Institute of Standards and Technology (NIST)
BACnet Device Emulator Users’ Guide
- 1 October 2018
- Published by National Institute of Standards and Technology (NIST)
Programmers guide to the BACnet communications DLL
- 1 October 2018
- Published by National Institute of Standards and Technology (NIST)
Programmers guide to the BACnet communications DLL
- 6 December 2017
- Published by National Institute of Standards and Technology (NIST)
Users guide to HVAC-Cx v2.2
- 6 December 2017
- Published by National Institute of Standards and Technology (NIST)
Users guide to HVAC-Cx v2.2
- 1 January 2017
- Vol. 123, 53-63
Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx
In this research we develop, test, and demonstrate the newest extension of the software HVAC-Cx (NIST and CSTB 2014), an automated commissioning tool for detecting common mechanical faults and control errors in chilled-water distribution systems (loops). The commissioning process can improve occupant comfort, ensure the persistence of correct system operation, and reduce energy consumption. Automated tools support the process by decreasing the time and the skill level required to carry out necessary quality assurance measures, and as a result they enable more thorough testing of building heating, ventilating, and air-conditioning (HVAC) systems. This paper describes the algorithm, developed by National Institute of Standards and Technology (NIST), to analyze chilled-water loops and presents the results of a passive monitoring investigation using field data obtained from BACnet® (ASHRAE 2016) controllers and presents field validation of the findings. The tool was successful in detecting faults in system operation in its first field implementation supporting the investigation phase through performance monitoring. Its findings led to a full energy retrocommissioning of the field site.
- 1 January 2017
- Vol. 123, 53-63
Performance Monitoring of Chilled-Water Distribution Systems Using HVAC-Cx
In this research we develop, test, and demonstrate the newest extension of the software HVAC-Cx (NIST and CSTB 2014), an automated commissioning tool for detecting common mechanical faults and control errors in chilled-water distribution systems (loops). The commissioning process can improve occupant comfort, ensure the persistence of correct system operation, and reduce energy consumption. Automated tools support the process by decreasing the time and the skill level required to carry out necessary quality assurance measures, and as a result they enable more thorough testing of building heating, ventilating, and air-conditioning (HVAC) systems. This paper describes the algorithm, developed by National Institute of Standards and Technology (NIST), to analyze chilled-water loops and presents the results of a passive monitoring investigation using field data obtained from BACnet® (ASHRAE 2016) controllers and presents field validation of the findings. The tool was successful in detecting faults in system operation in its first field implementation supporting the investigation phase through performance monitoring. Its findings led to a full energy retrocommissioning of the field site.
- 21 October 2015
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 21 (8) , 1154-1164
Evaluating the performance of Diagnostic Agent for Building Operation (DABO) and HVAC-Cx tools using the Virtual Cybernetic Building Testbed
- 21 October 2015
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 21 (8) , 1154-1164
Evaluating the performance of Diagnostic Agent for Building Operation (DABO) and HVAC-Cx tools using the Virtual Cybernetic Building Testbed