Tana Morrow
Research Subjects
Research Interests
Tana Morrow has a total of 244 co-authors. Here are the top co-authors by number of shared publications:
- Brian Michael Haines
Los Alamos National Laboratory
11 shared publications - Elizabeth Catherine Merritt
Los Alamos National Laboratory
10 shared publications - Eric Nicholas Loomis
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
9 shared publications - Thomas Joseph Murphy
Los Alamos National Laboratory, Los Alamos, USA
8 shared publications - Yongho Kim
Los Alamos National Laboratory
8 shared publications F. Fierro
Los Alamos National Labratory 1 , Los Alamos, New Mexico 87545, USA
7 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
A forward model for the design of a constant-time-resolution proton recoil telescope
Pulsed-power driven fusion is a growing area of study, with systems such as magnetized liner inertial fusion at Sandia National Laboratories (SNL). Capable nuclear reaction history diagnostics are currently limited at SNL. The Proton Trajectory Assay-Recoil Telescope (PAJARITO), an annular on-axis proton recoil telescope, was developed to fill this diagnostic gap. PAJARITO, however, has not been fully optimized or characterized within its full adjustment space. Existing simulation frameworks cannot adequately explore the full design envelope: high-accuracy tools such as the Monte-Carlo N-particle code can be time intensive, while analytical analyses lack detail on key aspects such as the signal shape or energy spectra. This motivates the development of a computational forward model that utilizes an expansion of the analytical formula into a gridded method, performing the analyses on many segments of the neutron-to-proton converter foil, enabling rapid estimation of signal shape, energy distribution, and times of flight that reproduce trends observed from Monte Carlo methods. This allows for quick characterization of key PAJARITO system parameters such as the system impulse response function (IRF), sensitivity, and minimum required yields. The fast nature of the forward model opens up the possibility of multi-parameter optimization studies. The forward model confirms the targeted sub-nanosecond system IRF and provides parameter changes to increase the system sensitivity with low impact on the IRF.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Open AccessA forward model for the design of a constant-time-resolution proton recoil telescope
Pulsed-power driven fusion is a growing area of study, with systems such as magnetized liner inertial fusion at Sandia National Laboratories (SNL). Capable nuclear reaction history diagnostics are currently limited at SNL. The Proton Trajectory Assay-Recoil Telescope (PAJARITO), an annular on-axis proton recoil telescope, was developed to fill this diagnostic gap. PAJARITO, however, has not been fully optimized or characterized within its full adjustment space. Existing simulation frameworks cannot adequately explore the full design envelope: high-accuracy tools such as the Monte-Carlo N-particle code can be time intensive, while analytical analyses lack detail on key aspects such as the signal shape or energy spectra. This motivates the development of a computational forward model that utilizes an expansion of the analytical formula into a gridded method, performing the analyses on many segments of the neutron-to-proton converter foil, enabling rapid estimation of signal shape, energy distribution, and times of flight that reproduce trends observed from Monte Carlo methods. This allows for quick characterization of key PAJARITO system parameters such as the system impulse response function (IRF), sensitivity, and minimum required yields. The fast nature of the forward model opens up the possibility of multi-parameter optimization studies. The forward model confirms the targeted sub-nanosecond system IRF and provides parameter changes to increase the system sensitivity with low impact on the IRF.
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Design considerations and forward modeling signal levels for a high dynamic range fusion reaction history diagnostic
A high-dynamic-range fusion reaction history measurement would offer powerful insight into the detailed dynamic evolution, energy balance, hotspot formation, and explosion of igniting fusion hotspots. We review the design principles of potential detector choices to make such a measurement. Results from a forward model using a detector similar to the existing Gamma Reaction History diagnostic, but placed farther from the target chamber and assuming an achieved signal-to-background, are shared. The results show that an optical splitter, a high-gain photomultiplier, and modest attenuation can meet the dynamic-range measurement requirements. The multichannel plate-charge limit, space-charge requirement, voltage, and multiplexing requirement can all be met for yields up to 70 MJ.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessDesign considerations and forward modeling signal levels for a high dynamic range fusion reaction history diagnostic
A high-dynamic-range fusion reaction history measurement would offer powerful insight into the detailed dynamic evolution, energy balance, hotspot formation, and explosion of igniting fusion hotspots. We review the design principles of potential detector choices to make such a measurement. Results from a forward model using a detector similar to the existing Gamma Reaction History diagnostic, but placed farther from the target chamber and assuming an achieved signal-to-background, are shared. The results show that an optical splitter, a high-gain photomultiplier, and modest attenuation can meet the dynamic-range measurement requirements. The multichannel plate-charge limit, space-charge requirement, voltage, and multiplexing requirement can all be met for yields up to 70 MJ.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
A spectroscopic analysis code for spatially resolved x-ray absorption data from the COAX platform
Sophisticated tools such as computer vision techniques in combination with 1D lineout type analyses have been used in automating the analysis of spectral data for high energy density (HED) plasmas. Standardized automation can solve the problems posed by the complexity of HED spectra and the quantity of data. We present a spectroscopic code written for automated and streamlined analysis of spatially resolved x-ray absorption data from the COAX platform on Omega-60. COAX uses radiographs and spectroscopic diagnostics to provide shock position and density information. We also obtain the more novel spectral-derived spatial profile of the supersonic radiation flow into a low-density foam. Considerable effort has been spent modernizing our previous spectroscopic analysis method, including the development of new tools characterized by a faster runtime and minimal user input to reduce bias and a testing suite for verifying the accuracy of the various functions within the code. The new code analyzes our spectroscopic images in 1–2 min, with added uncertainty and confidence.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessA spectroscopic analysis code for spatially resolved x-ray absorption data from the COAX platform
Sophisticated tools such as computer vision techniques in combination with 1D lineout type analyses have been used in automating the analysis of spectral data for high energy density (HED) plasmas. Standardized automation can solve the problems posed by the complexity of HED spectra and the quantity of data. We present a spectroscopic code written for automated and streamlined analysis of spatially resolved x-ray absorption data from the COAX platform on Omega-60. COAX uses radiographs and spectroscopic diagnostics to provide shock position and density information. We also obtain the more novel spectral-derived spatial profile of the supersonic radiation flow into a low-density foam. Considerable effort has been spent modernizing our previous spectroscopic analysis method, including the development of new tools characterized by a faster runtime and minimal user input to reduce bias and a testing suite for verifying the accuracy of the various functions within the code. The new code analyzes our spectroscopic images in 1–2 min, with added uncertainty and confidence.
- Open Access
- 23 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (10) , 4842-4850
Forward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium- Tritium Filled MagLIF Implosions on Sandia’s Z-Machine
Nuclear reaction history measurements provide a bang time and burn width of inertial confinement fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T, $\gamma $ ) $^{{5}}$ He reaction. Such DT-based reaction history measurements have not been made on the magnetized laser inertial fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history (GRH) on the Z-Machine. A forward model of the GRH diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte–Carlo N-Particle (MCNP)) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron-induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T $_{2}$ gas doping of MagLIF implosions a reaction history may be made for high performance shots $>$ 8e12–2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions, additional collimation will be needed to prevent the neutron-induced gamma rays from modifying the shape of the measured DT reaction history curve.
- 23 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (10) , 4842-4850
Open AccessForward Modeling of Gamma Reaction History Signatures From Anticipated Deuterium- Tritium Filled MagLIF Implosions on Sandia’s Z-Machine
Nuclear reaction history measurements provide a bang time and burn width of inertial confinement fusion (ICF) implosions and are essential for understanding implosion performance to constrain ICF capsule design. When fusion fuel contains Deuterium (D) and Tritium (T) gas, reaction history is informed by measuring the 16.75 MeV gamma rays generated from the D(T, $\gamma $ ) $^{{5}}$ He reaction. Such DT-based reaction history measurements have not been made on the magnetized laser inertial fusion (MagLIF) platform on Sandia’s Z-Machine due to the lack of Tritium being used. The recent development of ICF implosions with tritiated fuel will open the possibility of measuring the gamma reaction history (GRH) on the Z-Machine. A forward model of the GRH diagnostic on Z (GRH-Z) has been developed using the MCNP6.3 (Monte–Carlo N-Particle (MCNP)) radiation transport code. The model included the Z-Machine geometry of interest to characterize the impact of neutron-induced gamma rays on the DT reaction history measurements. In addition, the impulse response functions of the GRH-Z diagnostic to understand the temporal response of the detector and the minimum yields required to make a reaction history measurement were calculated. This approach also predicted that with T $_{2}$ gas doping of MagLIF implosions a reaction history may be made for high performance shots $>$ 8e12–2.4e13 depending on the chosen threshold for the detector, with a maximum signal to background ratio of 25%. It was found that for long duration ICF implosions, additional collimation will be needed to prevent the neutron-induced gamma rays from modifying the shape of the measured DT reaction history curve.
- Open Access
- 12 July 2024
- Published by Office of Scientific and Technical Information (OSTI)
The Wide-Angle X-Ray Electron Spectrometer Design
The U.S. Department of Energy's Office of Scientific and Technical Information
- 12 July 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessThe Wide-Angle X-Ray Electron Spectrometer Design
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 18 June 2024
- Published by Office of Scientific and Technical Information (OSTI)
Outer shell symmetry for double shell capsules with aluminum ablators
The U.S. Department of Energy's Office of Scientific and Technical Information
- 18 June 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessOuter shell symmetry for double shell capsules with aluminum ablators
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 1 June 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (6)
Outer shell symmetry for double shell capsules with aluminum ablators
Double shell targets are a promising potential avenue to obtain robust neutron yield at current laser facilities. Similar to single shell designs, double shells require the symmetric implosion of an ablator in order to uniformly compress and heat a fuel volume, with the goal of achieving thermonuclear burn. Significant differences between double and single shells include the usage of an aluminum ablator as well as a reverse ramp laser pulse. In addition, double shells require a different convergence than single shells for fuel ignition. Numerical implosion studies at various energies with comparisons to experimental outcomes are required to gain confidence that simulations can capture the ablator shape from subscale to full scale. The current work builds on previous implosion experiments conducted at 1-MJ laser energy to confirm achieved ablator symmetry at 1.25 and 1.5 MJ. Average ablator P2 and P4 shapes measured in these experiments are within 5% of the simulated shape, which merits the platforms for further experimental studies.
- 1 June 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (6)
Open AccessOuter shell symmetry for double shell capsules with aluminum ablators
Double shell targets are a promising potential avenue to obtain robust neutron yield at current laser facilities. Similar to single shell designs, double shells require the symmetric implosion of an ablator in order to uniformly compress and heat a fuel volume, with the goal of achieving thermonuclear burn. Significant differences between double and single shells include the usage of an aluminum ablator as well as a reverse ramp laser pulse. In addition, double shells require a different convergence than single shells for fuel ignition. Numerical implosion studies at various energies with comparisons to experimental outcomes are required to gain confidence that simulations can capture the ablator shape from subscale to full scale. The current work builds on previous implosion experiments conducted at 1-MJ laser energy to confirm achieved ablator symmetry at 1.25 and 1.5 MJ. Average ablator P2 and P4 shapes measured in these experiments are within 5% of the simulated shape, which merits the platforms for further experimental studies.
- Open Access
- 29 January 2024
- Published by Office of Scientific and Technical Information (OSTI)
Technician Opportunities at Los Alamos National Laboratory [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 29 January 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessTechnician Opportunities at Los Alamos National Laboratory [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 1 November 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (11)
Evaluation of the relative importance of preheat from hohlraum x rays and a radiative shock on a low-density foam
Indirectly driven shock-tube experiments were performed on the Omega Laser Facility to evaluate the relative importance of hohlraum x ray and radiative shock preheat sources on a low-density foam. X rays emitted from the hohlraum and a subsequent shock wave are channeled into a low-density foam sample, which contains a plastic preheat-witness disk placed downstream of the foam. Simultaneous radiographic measurements of the shock speed in the foam and the expansion rate of the witness disk due to preheat allow for the observation of effects from the hohlraum's low-energy and high-energy x-ray spectrum. We showed, from simulations, that low-energy x rays from the hohlraum are preferentially absorbed near the ablator surface (where the hohlraum and the shock tube meet), while higher-energy x rays largely pass through the ablator and foam and are volumetrically absorbed by the witness disk. Reproducing the experimentally measured shock speed and expansion of the witness disk simultaneously, we extracted the temperature evolution of preheated foam from the simulation and evaluated the relative importance of preheat sources on a low-density foam from hohlraum x-ray radiation and radiative shock. We found that radiation from the shock front was more effective at preheating the low-density foam than the high-energy x rays from the hohlraum. This shock-tube preheat experiment is important for understanding the results of the MARBLE experiments at the National Ignition Facility because initial conditions of foam-filled MARBLE capsules are sensitive to preheat.
- 1 November 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (11)
Open AccessEvaluation of the relative importance of preheat from hohlraum x rays and a radiative shock on a low-density foam
Indirectly driven shock-tube experiments were performed on the Omega Laser Facility to evaluate the relative importance of hohlraum x ray and radiative shock preheat sources on a low-density foam. X rays emitted from the hohlraum and a subsequent shock wave are channeled into a low-density foam sample, which contains a plastic preheat-witness disk placed downstream of the foam. Simultaneous radiographic measurements of the shock speed in the foam and the expansion rate of the witness disk due to preheat allow for the observation of effects from the hohlraum's low-energy and high-energy x-ray spectrum. We showed, from simulations, that low-energy x rays from the hohlraum are preferentially absorbed near the ablator surface (where the hohlraum and the shock tube meet), while higher-energy x rays largely pass through the ablator and foam and are volumetrically absorbed by the witness disk. Reproducing the experimentally measured shock speed and expansion of the witness disk simultaneously, we extracted the temperature evolution of preheated foam from the simulation and evaluated the relative importance of preheat sources on a low-density foam from hohlraum x-ray radiation and radiative shock. We found that radiation from the shock front was more effective at preheating the low-density foam than the high-energy x rays from the hohlraum. This shock-tube preheat experiment is important for understanding the results of the MARBLE experiments at the National Ignition Facility because initial conditions of foam-filled MARBLE capsules are sensitive to preheat.