John P. Lenihan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
John P. Lenihan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Antonio R. Gargiulo
Harvard Medical School, Center for Infertility and Reproductive Surgery, Brigham and Women’s Hospital
2 shared publications Anand Malpani
None
1 shared publication- Anand Malpani
Surgical Science, Seattle, USA
1 shared publication Carol Kovanda
Department of Obstetrics and Gynecology, MultiCare Health Systems, and Tacoma Women's Specialists, Tacoma, WA
1 shared publicationChris Simmonds Bsc
None
1 shared publication- Christopher Simmonds
Mimic Technologies Inc., Seattle, USA
1 shared publication
Latest Publications
- 7 March 2024
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-9
Evaluation of different approaches to define expert benchmark scores for new robotic training simulators based on the Medtronic HUGO™ RAS surgical robot experience
New robot-assisted surgery platforms being developed will be required to have proficiency-based simulation training available. Scoring methodologies and performance feedback for trainees are currently not consistent across all robotic simulator platforms. Also, there are virtually no prior publications on how VR simulation passing benchmarks have been established. This paper compares methods evaluated to determine the proficiency-based scoring thresholds (a.k.a. benchmarks) for the new Medtronic Hugo™ RAS robotic simulator. Nine experienced robotic surgeons from multiple disciplines performed the 49 skills exercises 5 times each. The data were analyzed in 3 different ways: (1) include all data collected, (2) exclude first sessions, (3) exclude outliers. Eliminating the first session discounts becoming familiar with the exercise. Discounting outliers allows removal of potentially erroneous data that may be due to technical issues, unexpected distractions, etc. Outliers were identified using a common statistical technique involving the interquartile range of the data. Using each method above, mean and standard deviations were calculated, and the benchmark was set at a value of 1 standard deviation above the mean. In comparison to including all the data, when outliers are excluded, fewer data points are removed than just excluding first sessions, and the metric benchmarks are made more difficult by an average of 11%. When first sessions are excluded, the metric benchmarks are made easier by an average of about 2%. In comparison with benchmarks calculated using all data points, excluding outliers resulted in the biggest change making the benchmarks more challenging. We determined that this method provided the best representation of the data. These benchmarks should be validated with future clinical training studies.
- 7 March 2024
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 18 (1) , 1-9
Evaluation of different approaches to define expert benchmark scores for new robotic training simulators based on the Medtronic HUGO™ RAS surgical robot experience
New robot-assisted surgery platforms being developed will be required to have proficiency-based simulation training available. Scoring methodologies and performance feedback for trainees are currently not consistent across all robotic simulator platforms. Also, there are virtually no prior publications on how VR simulation passing benchmarks have been established. This paper compares methods evaluated to determine the proficiency-based scoring thresholds (a.k.a. benchmarks) for the new Medtronic Hugo™ RAS robotic simulator. Nine experienced robotic surgeons from multiple disciplines performed the 49 skills exercises 5 times each. The data were analyzed in 3 different ways: (1) include all data collected, (2) exclude first sessions, (3) exclude outliers. Eliminating the first session discounts becoming familiar with the exercise. Discounting outliers allows removal of potentially erroneous data that may be due to technical issues, unexpected distractions, etc. Outliers were identified using a common statistical technique involving the interquartile range of the data. Using each method above, mean and standard deviations were calculated, and the benchmark was set at a value of 1 standard deviation above the mean. In comparison to including all the data, when outliers are excluded, fewer data points are removed than just excluding first sessions, and the metric benchmarks are made more difficult by an average of 11%. When first sessions are excluded, the metric benchmarks are made easier by an average of about 2%. In comparison with benchmarks calculated using all data points, excluding outliers resulted in the biggest change making the benchmarks more challenging. We determined that this method provided the best representation of the data. These benchmarks should be validated with future clinical training studies.
- Open Access
- 18 January 2024
- Published by Springer Nature in Research Square
Evaluation of Different Approaches to Define Expert Benchmark Scores for New Robotic Training Simulators Based on the Medtronic HUGOTM RAS Surgical Robot Experience
Introduction New robot-assisted surgery platforms being developed will be required to have proficiency-based simulation training available. Scoring methodologies and performance feedback for trainees are not consistent across all simulator platforms. This paper compares methods used to determine proficiency-based scoring thresholds (a.k.a. benchmarks) for the new Medtronic Hugo™ RAS robotic simulator. Methods Nine experienced robotic surgeons from multiple disciplines performed the 49 skills exercises 5 times each. The data was analyzed 3 different ways: (1) include all data collected, (2) exclude first sessions, (3) exclude outliers. Eliminating the first session discounts becoming familiar with the exercise. Discounting outliers allows for removal of potentially erroneous data that may be due to technical issues, unexpected distractions, etc. Outliers were identified using a common statistical technique involving the interquartile range of the data. Using each method above, the mean and standard deviations were calculated, and the benchmark was set at a value of 1 standard deviation above the mean. Results In comparison to including all the data, when outliers are excluded, fewer data points are removed than excluding just first sessions, and the metric benchmarks are made more difficult by an average of 11%. When first sessions are excluded, the metric benchmarks are made easier by an average of about 2%. Conclusion In comparison with benchmarks calculated using all data points, excluding outliers resulted in the biggest change making the benchmarks more challenging. We determined that this method provided the best representation of the data. These benchmarks should be validated with future clinical training studies.
- 18 January 2024
- Published by Springer Nature in Research Square
Open AccessEvaluation of Different Approaches to Define Expert Benchmark Scores for New Robotic Training Simulators Based on the Medtronic HUGOTM RAS Surgical Robot Experience
Introduction New robot-assisted surgery platforms being developed will be required to have proficiency-based simulation training available. Scoring methodologies and performance feedback for trainees are not consistent across all simulator platforms. This paper compares methods used to determine proficiency-based scoring thresholds (a.k.a. benchmarks) for the new Medtronic Hugo™ RAS robotic simulator. Methods Nine experienced robotic surgeons from multiple disciplines performed the 49 skills exercises 5 times each. The data was analyzed 3 different ways: (1) include all data collected, (2) exclude first sessions, (3) exclude outliers. Eliminating the first session discounts becoming familiar with the exercise. Discounting outliers allows for removal of potentially erroneous data that may be due to technical issues, unexpected distractions, etc. Outliers were identified using a common statistical technique involving the interquartile range of the data. Using each method above, the mean and standard deviations were calculated, and the benchmark was set at a value of 1 standard deviation above the mean. Results In comparison to including all the data, when outliers are excluded, fewer data points are removed than excluding just first sessions, and the metric benchmarks are made more difficult by an average of 11%. When first sessions are excluded, the metric benchmarks are made easier by an average of about 2%. Conclusion In comparison with benchmarks calculated using all data points, excluding outliers resulted in the biggest change making the benchmarks more challenging. We determined that this method provided the best representation of the data. These benchmarks should be validated with future clinical training studies.
- 2 December 2023
- Published by Springer Nature
- p. 773-799
Robotic Surgery in Gynecology: Indications, Advantages, Avoiding Complications, Training, and Future Platforms–Update 2022
- 2 December 2023
- Published by Springer Nature
- p. 773-799
Robotic Surgery in Gynecology: Indications, Advantages, Avoiding Complications, Training, and Future Platforms–Update 2022
- 6 July 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (10) , 5867-5875
Evaluation of a novel universal robotic surgery virtual reality simulation proficiency index that will allow comparisons of users across any virtual reality simulation curriculum
Study objective Evaluate a universal proficiency metric for Robotic Surgery Virtual Reality (VR) simulation that will allow comparison of all users across any VR curriculum. Design Retrospective analysis of VR Simulation metrics. Setting Two training institutions. Patients or participants Residents, fellows and practicing surgeons. Interventions Analysis of the Mimic robotic Virtual Reality (VR)-Simulation database of over 600,000 sessions was utilized to calculate Mean scores for each exercise. Those Mean scores were then normalized to 100. Subject's scores were also averaged and normalized to 100. We called this Index score the MScore Proficiency Index (MPI©). Scores above 100 were better than average; Less than 100 were worse than average. Measurements and main results Seventeen thousand six hundred and forty eight sessions were analyzed (2017–2020) comparing 77 students (residents to practicing surgeons) working in 7 different curriculums. On average, each student spent 8 h and 24 min on simulation, attempted 26.5 different exercises, and became proficient in 20.6 exercises per user. The MPI© mean score for all participants in all curricula was an MPI© of 104.9 (SD: 15.5). Thirteen students were 1 standard deviation below the norm with an average MPI© of 80.15. This group averaged 9 h 27 min each on the simulator attempting 23.46 exercises but becoming proficient in only 10.38 (47%) of them in 224 sessions. Twelve students were 1 standard deviation above the norm with an average MPI© of 127.05. This group averaged 6 h 31 min each on the simulator attempting 29.08 exercises but becoming proficient in 27.5 (95%) of them in 196 sessions. Conclusion A universal skill-based performance index (MPI©) was calculated and found to be a reliable tool that could be used to identify relative proficiency among students in different robotic surgery VR Simulation curriculums. An individual user’s proficiency can be utilized to identify a student’s progress in a given curriculum. Future studies of MPI© will determine if machine learning can provide timely personalized feedback to the user.
- 6 July 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (10) , 5867-5875
Evaluation of a novel universal robotic surgery virtual reality simulation proficiency index that will allow comparisons of users across any virtual reality simulation curriculum
Study objective Evaluate a universal proficiency metric for Robotic Surgery Virtual Reality (VR) simulation that will allow comparison of all users across any VR curriculum. Design Retrospective analysis of VR Simulation metrics. Setting Two training institutions. Patients or participants Residents, fellows and practicing surgeons. Interventions Analysis of the Mimic robotic Virtual Reality (VR)-Simulation database of over 600,000 sessions was utilized to calculate Mean scores for each exercise. Those Mean scores were then normalized to 100. Subject's scores were also averaged and normalized to 100. We called this Index score the MScore Proficiency Index (MPI©). Scores above 100 were better than average; Less than 100 were worse than average. Measurements and main results Seventeen thousand six hundred and forty eight sessions were analyzed (2017–2020) comparing 77 students (residents to practicing surgeons) working in 7 different curriculums. On average, each student spent 8 h and 24 min on simulation, attempted 26.5 different exercises, and became proficient in 20.6 exercises per user. The MPI© mean score for all participants in all curricula was an MPI© of 104.9 (SD: 15.5). Thirteen students were 1 standard deviation below the norm with an average MPI© of 80.15. This group averaged 9 h 27 min each on the simulator attempting 23.46 exercises but becoming proficient in only 10.38 (47%) of them in 224 sessions. Twelve students were 1 standard deviation above the norm with an average MPI© of 127.05. This group averaged 6 h 31 min each on the simulator attempting 29.08 exercises but becoming proficient in 27.5 (95%) of them in 196 sessions. Conclusion A universal skill-based performance index (MPI©) was calculated and found to be a reliable tool that could be used to identify relative proficiency among students in different robotic surgery VR Simulation curriculums. An individual user’s proficiency can be utilized to identify a student’s progress in a given curriculum. Future studies of MPI© will determine if machine learning can provide timely personalized feedback to the user.
- 1 November 2017
- Published by Elsevier in Best Practice & Research Clinical Obstetrics & Gynaecology
- Vol. 45, 19-31
How to set up a robotic-assisted laparoscopic surgery center and training of staff
- 1 November 2017
- Published by Elsevier in Best Practice & Research Clinical Obstetrics & Gynaecology
- Vol. 45, 19-31
How to set up a robotic-assisted laparoscopic surgery center and training of staff
- 25 August 2011
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 6 (1) , 47-52
Web-connected surgery: using the internet for teaching and proctoring of live robotic surgeries
The purpose of this study was to assess the feasibility of using live teleconferencing for teaching of new robotic-assisted surgical techniques. This was a prospective study with review of outcomes (Canadian Task Force classification II-3) in a community hospital. In 2009, our community hospital acquired the da Vinci Connect™ System, a technology which allows for live surgeon-to-surgeon interaction during robotic surgery via a secure internet connection. We utilized this technology from March 2009 through March 2011 to perform 28 live robotic surgeries that were observed by surgeons and hospital staff in 14 different US states as well as in France. We also had 14 episodes where new robotic surgeons in our facilities were mentored by experienced robotic surgeons in other geographic locations live through the da Vinci Connect internet connection. We performed two live surgeries for continuing medical education courses with live interactions between the course attendees and the console surgeon. Finally, one surgeon in our hospital proctored new surgeons remotely in distant sites on challenging cases. Utilizing computers that allow an experienced mentor surgeon to interact with less experienced surgeons on a live case is invaluable and presages the way we will train surgeons in the future. This feasibility study validates the need to pursue this technology for future education and training as well as for real-time collaboration.
- 25 August 2011
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 6 (1) , 47-52
Web-connected surgery: using the internet for teaching and proctoring of live robotic surgeries
The purpose of this study was to assess the feasibility of using live teleconferencing for teaching of new robotic-assisted surgical techniques. This was a prospective study with review of outcomes (Canadian Task Force classification II-3) in a community hospital. In 2009, our community hospital acquired the da Vinci Connect™ System, a technology which allows for live surgeon-to-surgeon interaction during robotic surgery via a secure internet connection. We utilized this technology from March 2009 through March 2011 to perform 28 live robotic surgeries that were observed by surgeons and hospital staff in 14 different US states as well as in France. We also had 14 episodes where new robotic surgeons in our facilities were mentored by experienced robotic surgeons in other geographic locations live through the da Vinci Connect internet connection. We performed two live surgeries for continuing medical education courses with live interactions between the course attendees and the console surgeon. Finally, one surgeon in our hospital proctored new surgeons remotely in distant sites on challenging cases. Utilizing computers that allow an experienced mentor surgeon to interact with less experienced surgeons on a live case is invaluable and presages the way we will train surgeons in the future. This feasibility study validates the need to pursue this technology for future education and training as well as for real-time collaboration.
- 1 May 2010
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 17 (3) , 280-281
Bilateral Ovarian Vein Thromboses in a Postmenopausal Woman with Uterine Prolapse
- 1 May 2010
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 17 (3) , 280-281
Bilateral Ovarian Vein Thromboses in a Postmenopausal Woman with Uterine Prolapse
- 1 October 2005
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 12 (5) , 415-419
Oral and local anesthesia in the nonsurgical radiofrequency-energy treatment of stress urinary incontinence
- 1 October 2005
- Published by Elsevier in Journal of Minimally Invasive Gynecology
- Vol. 12 (5) , 415-419
Oral and local anesthesia in the nonsurgical radiofrequency-energy treatment of stress urinary incontinence