Olivier Brina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Olivier Brina has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Karl-Olof Lövblad
Geneva University Hospitals
5 shared publications - Paolo Machi
Diagnostic and Interventional Neuroradiology, Geneva University Hospitals, Switzerland (J.H., P.M.).
4 shared publications - Vitor Mendes Pereira
Divisions of Therapeutic Neuroradiology and Neurosurgery, Neurovascular Centre, St. Michael Hospital, University of Toronto, ON, Canada (V.M.P.).
4 shared publications - Maria Isabel Vargas
University of Geneva
3 shared publications - P. Bouillot
University of Geneva
3 shared publications - Philippe Reymond
Geneva University Hospitals
3 shared publications
Latest Publications
- Open Access
- 23 March 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (8) , 1031-1037
Double Stent Retriever Technique for Mechanical Thrombectomy: A Systematic Review and Meta-Analysis
BACKGROUND: Mechanical thrombectomy using a double stent-retriever technique has recently been described for the treatment of acute ischemic stroke, but its efficacy and safety are not well established. PURPOSE: The aim of this systematic review and meta-analysis was to evaluate reports of the use of double stent-retriever during the endovascular treatment of patients with ischemic stroke. DATA SOURCES: The PubMed, Embase, Web of Science and Scopus databases were searched to identify all studies (clinical trials, cohorts series and case reports) investigating the utility of double stent-retriever for the treatment of stroke. The study is reported in accordance with PRISMA 2020 guidelines and was prospectively registered in PROSPERO (BLINDED FOR PEER REVIEW). STUDY SELECTION: 17 studies involving a total of 128 patients with large vessel occlusions predominantly in the anterior circulation (93.0%) were identified. DATA ANALYSIS: Outcomes of interest were the prevalence of successful recanalization (mTICI ≥2b) and a first-pass effect following double stent-retriever, as well as complications such as iatrogenic dissections and subarachnoid hemorrhage. Data were pooled using a random-effects model. DATA SYNTHESIS: Double stent-retriever was used as a rescue strategy in occlusions refractory to conventional endovascular treatment in 68.7% (88/128) of patients and as a first-line strategy in 31.3% (40/128) patients. Double stent-retriever achieved an overall final mTICI ≥2b in 92.6% cases with a first-pass effect of 76.6%. The complication rate remained low, with 0.37% dissection and 1.56% subarachnoid hemorrhage. LIMITATIONS: Limitations of the study include (1) a large number of case reports or small series, (2) a meta-analysis of proportions with no statistical comparison to a control group, and (3) the lack of access to patient-level data. CONCLUSIONS: Our findings suggest that double stent-retriever thrombectomy may be safe and associated with good recanalization outcomes, but prospective comparative studies are needed to determine which patients may benefit from this endovascular procedure. ABBREVIATIONS: AICH = asymptomatic intracranial hemorrhage; AIS = acute ischemic stroke; DSR = double stent-retriever; FPE = first pass effect; ICH = intracranial hemorrhage; LVO = large vessel occlusion; MT = mechanical thrombectomy; SAH = subarachnoid hemorrhage; SICH = symptomatic intracranial hemorrhage; SSR = single stent-retriever.
- 23 March 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (8) , 1031-1037
Open AccessDouble Stent Retriever Technique for Mechanical Thrombectomy: A Systematic Review and Meta-Analysis
BACKGROUND: Mechanical thrombectomy using a double stent-retriever technique has recently been described for the treatment of acute ischemic stroke, but its efficacy and safety are not well established. PURPOSE: The aim of this systematic review and meta-analysis was to evaluate reports of the use of double stent-retriever during the endovascular treatment of patients with ischemic stroke. DATA SOURCES: The PubMed, Embase, Web of Science and Scopus databases were searched to identify all studies (clinical trials, cohorts series and case reports) investigating the utility of double stent-retriever for the treatment of stroke. The study is reported in accordance with PRISMA 2020 guidelines and was prospectively registered in PROSPERO (BLINDED FOR PEER REVIEW). STUDY SELECTION: 17 studies involving a total of 128 patients with large vessel occlusions predominantly in the anterior circulation (93.0%) were identified. DATA ANALYSIS: Outcomes of interest were the prevalence of successful recanalization (mTICI ≥2b) and a first-pass effect following double stent-retriever, as well as complications such as iatrogenic dissections and subarachnoid hemorrhage. Data were pooled using a random-effects model. DATA SYNTHESIS: Double stent-retriever was used as a rescue strategy in occlusions refractory to conventional endovascular treatment in 68.7% (88/128) of patients and as a first-line strategy in 31.3% (40/128) patients. Double stent-retriever achieved an overall final mTICI ≥2b in 92.6% cases with a first-pass effect of 76.6%. The complication rate remained low, with 0.37% dissection and 1.56% subarachnoid hemorrhage. LIMITATIONS: Limitations of the study include (1) a large number of case reports or small series, (2) a meta-analysis of proportions with no statistical comparison to a control group, and (3) the lack of access to patient-level data. CONCLUSIONS: Our findings suggest that double stent-retriever thrombectomy may be safe and associated with good recanalization outcomes, but prospective comparative studies are needed to determine which patients may benefit from this endovascular procedure. ABBREVIATIONS: AICH = asymptomatic intracranial hemorrhage; AIS = acute ischemic stroke; DSR = double stent-retriever; FPE = first pass effect; ICH = intracranial hemorrhage; LVO = large vessel occlusion; MT = mechanical thrombectomy; SAH = subarachnoid hemorrhage; SICH = symptomatic intracranial hemorrhage; SSR = single stent-retriever.
- Open Access
- 19 February 2022
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 50 (1) , 74-78
Experimental evaluation of the performance of large bore aspiration catheters
- 19 February 2022
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 50 (1) , 74-78
Open AccessExperimental evaluation of the performance of large bore aspiration catheters
- Open Access
- 13 February 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (3) , 488-494
Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter
BACKGROUND AND PURPOSE: Flow diverter–induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms. MATERIALS AND METHODS: MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters. RESULTS: After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively. CONCLUSIONS: Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.
- 13 February 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (3) , 488-494
Open AccessLarge Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter
BACKGROUND AND PURPOSE: Flow diverter–induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms. MATERIALS AND METHODS: MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters. RESULTS: After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively. CONCLUSIONS: Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.
- Open Access
- 14 November 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (12) , 2117-2123
How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study
BACKGROUND AND PURPOSE: Flow-diverter stents are widely used for the treatment of wide-neck intracranial aneurysms. Various parameters may influence intracranial aneurysm thrombosis, including the flow reduction induced by flow-diverter stent implantation, which is assumed to play a leading role. However, its actual impact remains unclear due to the lack of detailed intra-aneurysmal flow measurements. This study aimed to clarify this relationship by quantitatively measuring the intra-aneurysmal flow using 4D phase-contrast MR imaging. MATERIALS AND METHODS: We acquired prospective pre- and post-stent implantation 4D phase-contrast MR imaging data of a consecutive series of 23 patients treated with flow-diverter stents. Velocity field data were combined with the intraprocedural 3D angiogram vessel geometries for precise intracranial aneurysm extraction and partial volume correction. Intra-aneurysmal hemodynamic modifications were compared with occlusion outcomes at 6 and 12 months. RESULTS: The averaged velocities at systole were lower after flow-diverter stent implantation for all patients and ranged from 21.7 ± 7.1 cm/s before to 7.2 ± 2.9 cm/s after stent placement. The velocity reduction was more important for the group of patients with aneurysm thrombosis at 6 months (68.8%) and decreased gradually from 66.2% to 55% for 12-month thrombosis and no thrombosis, respectively (P = .08). CONCLUSIONS: We propose an innovative approach to measure intracranial flow changes after flow-diverter stent implantation. We identified a trend between flow reduction and thrombosis outcome that brings a new insight into current understanding of the flow-diversion treatment response.
- 14 November 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (12) , 2117-2123
Open AccessHow Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study
BACKGROUND AND PURPOSE: Flow-diverter stents are widely used for the treatment of wide-neck intracranial aneurysms. Various parameters may influence intracranial aneurysm thrombosis, including the flow reduction induced by flow-diverter stent implantation, which is assumed to play a leading role. However, its actual impact remains unclear due to the lack of detailed intra-aneurysmal flow measurements. This study aimed to clarify this relationship by quantitatively measuring the intra-aneurysmal flow using 4D phase-contrast MR imaging. MATERIALS AND METHODS: We acquired prospective pre- and post-stent implantation 4D phase-contrast MR imaging data of a consecutive series of 23 patients treated with flow-diverter stents. Velocity field data were combined with the intraprocedural 3D angiogram vessel geometries for precise intracranial aneurysm extraction and partial volume correction. Intra-aneurysmal hemodynamic modifications were compared with occlusion outcomes at 6 and 12 months. RESULTS: The averaged velocities at systole were lower after flow-diverter stent implantation for all patients and ranged from 21.7 ± 7.1 cm/s before to 7.2 ± 2.9 cm/s after stent placement. The velocity reduction was more important for the group of patients with aneurysm thrombosis at 6 months (68.8%) and decreased gradually from 66.2% to 55% for 12-month thrombosis and no thrombosis, respectively (P = .08). CONCLUSIONS: We propose an innovative approach to measure intracranial flow changes after flow-diverter stent implantation. We identified a trend between flow reduction and thrombosis outcome that brings a new insight into current understanding of the flow-diversion treatment response.
- Open Access
- 21 December 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (2) , 337-343
Better Than Nothing: A Rational Approach for Minimizing the Impact of Outflow Strategy on Cerebrovascular Simulations
BACKGROUND AND PURPOSE: Computational fluid dynamics simulations of neurovascular diseases are impacted by various modeling assumptions and uncertainties, including outlet boundary conditions. Many studies of intracranial aneurysms, for example, assume zero pressure at all outlets, often the default (“do-nothing”) strategy, with no physiological basis. Others divide outflow according to the outlet diameters cubed, nominally based on the more physiological Murray9s law but still susceptible to subjective choices about the segmented model extent. Here we demonstrate the limitations and impact of these outflow strategies, against a novel “splitting” method introduced here. MATERIALS AND METHODS: With our method, the segmented lumen is split into its constituent bifurcations, where flow divisions are estimated locally using a power law. Together these provide the global outflow rate boundary conditions. The impact of outflow strategy on flow rates was tested for 70 cases of MCA aneurysm with 0D simulations. The impact on hemodynamic indices used for rupture status assessment was tested for 10 cases with 3D simulations. RESULTS: Differences in flow rates among the various strategies were up to 70%, with a non-negligible impact on average and oscillatory wall shear stresses in some cases. Murray-law and splitting methods gave flow rates closest to physiological values reported in the literature; however, only the splitting method was insensitive to arbitrary truncation of the model extent. CONCLUSIONS: Cerebrovascular simulations can depend strongly on the outflow strategy. The default zero-pressure method should be avoided in favor of Murray-law or splitting methods, the latter being released as an open-source tool to encourage the standardization of outflow strategies.
- 21 December 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (2) , 337-343
Open AccessBetter Than Nothing: A Rational Approach for Minimizing the Impact of Outflow Strategy on Cerebrovascular Simulations
BACKGROUND AND PURPOSE: Computational fluid dynamics simulations of neurovascular diseases are impacted by various modeling assumptions and uncertainties, including outlet boundary conditions. Many studies of intracranial aneurysms, for example, assume zero pressure at all outlets, often the default (“do-nothing”) strategy, with no physiological basis. Others divide outflow according to the outlet diameters cubed, nominally based on the more physiological Murray9s law but still susceptible to subjective choices about the segmented model extent. Here we demonstrate the limitations and impact of these outflow strategies, against a novel “splitting” method introduced here. MATERIALS AND METHODS: With our method, the segmented lumen is split into its constituent bifurcations, where flow divisions are estimated locally using a power law. Together these provide the global outflow rate boundary conditions. The impact of outflow strategy on flow rates was tested for 70 cases of MCA aneurysm with 0D simulations. The impact on hemodynamic indices used for rupture status assessment was tested for 10 cases with 3D simulations. RESULTS: Differences in flow rates among the various strategies were up to 70%, with a non-negligible impact on average and oscillatory wall shear stresses in some cases. Murray-law and splitting methods gave flow rates closest to physiological values reported in the literature; however, only the splitting method was insensitive to arbitrary truncation of the model extent. CONCLUSIONS: Cerebrovascular simulations can depend strongly on the outflow strategy. The default zero-pressure method should be avoided in favor of Murray-law or splitting methods, the latter being released as an open-source tool to encourage the standardization of outflow strategies.
- Open Access
- 15 September 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (12) , 2293-2298
Does Arterial Flow Rate Affect the Assessment of Flow-Diverter Stent Performance?
BACKGROUND AND PURPOSE: Our aim was to assess the performance of flow-diverter stents. The pre- and end-of-treatment angiographies are commonly compared. However, the arterial flow rate may change between acquisitions; therefore, a better understanding of its influence on the local intra-aneurysmal hemodynamics before and after flow-diverter stent use is required. MATERIALS AND METHODS: Twenty-five image-based aneurysm models extracted from 3D rotational angiograms were conditioned for computational fluid dynamics simulations. Pulsatile simulations were performed at different arterial flow rates, covering a wide possible range of physiologic flows among 1–5 mL/s. The effect of flow-diverter stents on intra-aneurysmal hemodynamics was numerically simulated with a porous medium model. Spatiotemporal-averaged intra-aneurysmal flow velocity and flow rate were calculated for each case to quantify the hemodynamics after treatment. The short-term flow-diverter stent performance was characterized by the relative velocity reduction inside the aneurysm. RESULTS: Spatiotemporal-averaged intra-aneurysmal flow velocity before and after flow-diverter stent use is linearly proportional to the mean arterial flow rate (minimum R2 > 0.983 of the linear regression models for untreated and stented models). Relative velocity reduction asymptotically decreases with increasing mean arterial flow rate. When the most probable range of arterial flow rate was considered (3–5 mL/s), instead of the wide possible flow range, the mean SD of relative velocity reduction was reduced from 3.6% to 0.48%. CONCLUSIONS: Both intra-aneurysmal aneurysm velocity and flow-diverter stent performance depend on the arterial flow rate. The performance could be considered independent of the arterial flow rates within the most probable range of physiologic flows.
- 15 September 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (12) , 2293-2298
Open AccessDoes Arterial Flow Rate Affect the Assessment of Flow-Diverter Stent Performance?
BACKGROUND AND PURPOSE: Our aim was to assess the performance of flow-diverter stents. The pre- and end-of-treatment angiographies are commonly compared. However, the arterial flow rate may change between acquisitions; therefore, a better understanding of its influence on the local intra-aneurysmal hemodynamics before and after flow-diverter stent use is required. MATERIALS AND METHODS: Twenty-five image-based aneurysm models extracted from 3D rotational angiograms were conditioned for computational fluid dynamics simulations. Pulsatile simulations were performed at different arterial flow rates, covering a wide possible range of physiologic flows among 1–5 mL/s. The effect of flow-diverter stents on intra-aneurysmal hemodynamics was numerically simulated with a porous medium model. Spatiotemporal-averaged intra-aneurysmal flow velocity and flow rate were calculated for each case to quantify the hemodynamics after treatment. The short-term flow-diverter stent performance was characterized by the relative velocity reduction inside the aneurysm. RESULTS: Spatiotemporal-averaged intra-aneurysmal flow velocity before and after flow-diverter stent use is linearly proportional to the mean arterial flow rate (minimum R2 > 0.983 of the linear regression models for untreated and stented models). Relative velocity reduction asymptotically decreases with increasing mean arterial flow rate. When the most probable range of arterial flow rate was considered (3–5 mL/s), instead of the wide possible flow range, the mean SD of relative velocity reduction was reduced from 3.6% to 0.48%. CONCLUSIONS: Both intra-aneurysmal aneurysm velocity and flow-diverter stent performance depend on the arterial flow rate. The performance could be considered independent of the arterial flow rates within the most probable range of physiologic flows.
- Open Access
- 30 June 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (11) , 2079-2086
Virtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry
BACKGROUND AND PURPOSE: Intracranial stents have become extremely important in the endovascular management of complex intracranial aneurysms. Sizing and landing zone predictions are still very challenging steps in the procedure. Virtual stent deployment may help therapeutic planning, device choice, and hemodynamic simulations. We aimed to assess the predictability of our recently developed virtual deployment model by comparing in vivo and virtual stents implanted in a consecutive series of patients presenting with intracranial aneurysms. MATERIALS AND METHODS: Virtual stents were implanted in patient-specific geometries of intracranial aneurysms treated with the Pipeline Embolization Device. The length and cross-section of virtual and real stents measured with conebeam CT were compared. The influence of vessel geometry modifications occurring during the intervention was analyzed. RESULTS: The virtual deployment based on pre- and poststent implantation 3D rotational angiography overestimated (underestimated) the device length by 13% ± 11% (−9% ± 5%). These differences were highly correlated (R2 = 0.67) with the virtual-versus-real stent radius differences of −6% ± 7% (5% ± 4%) for predictions based on pre- and poststent implantation 3D rotational angiography. These mismatches were due principally to implantation concerns and vessel-shape modifications. CONCLUSIONS: The recently proposed geometric model was shown to predict accurately the deployment of Pipeline Embolization Devices when the stent radius was well-assessed. However, unpredictable delivery manipulations and variations of vessel geometry occurring during the intervention might impact the stent implantation.
- 30 June 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (11) , 2079-2086
Open AccessVirtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry
BACKGROUND AND PURPOSE: Intracranial stents have become extremely important in the endovascular management of complex intracranial aneurysms. Sizing and landing zone predictions are still very challenging steps in the procedure. Virtual stent deployment may help therapeutic planning, device choice, and hemodynamic simulations. We aimed to assess the predictability of our recently developed virtual deployment model by comparing in vivo and virtual stents implanted in a consecutive series of patients presenting with intracranial aneurysms. MATERIALS AND METHODS: Virtual stents were implanted in patient-specific geometries of intracranial aneurysms treated with the Pipeline Embolization Device. The length and cross-section of virtual and real stents measured with conebeam CT were compared. The influence of vessel geometry modifications occurring during the intervention was analyzed. RESULTS: The virtual deployment based on pre- and poststent implantation 3D rotational angiography overestimated (underestimated) the device length by 13% ± 11% (−9% ± 5%). These differences were highly correlated (R2 = 0.67) with the virtual-versus-real stent radius differences of −6% ± 7% (5% ± 4%) for predictions based on pre- and poststent implantation 3D rotational angiography. These mismatches were due principally to implantation concerns and vessel-shape modifications. CONCLUSIONS: The recently proposed geometric model was shown to predict accurately the deployment of Pipeline Embolization Devices when the stent radius was well-assessed. However, unpredictable delivery manipulations and variations of vessel geometry occurring during the intervention might impact the stent implantation.