ANAleš Neubert

Aleš Neubert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aleš Neubert has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the Impact of High Intensity Interval Training on Axial Psoriatic Arthritis Based on MR Images

    by Ioanna Chronaiou, Guro Fanneløb Giskeødegård, Ales Neubert, Tamara Viola Hoffmann-Skjøstad, Ruth Stoklund Thomsen, Mari Hoff, Tone Frost Bathen, Beathe Sitter

    High intensity interval training (HIIT) has been shown to benefit patients with psoriatic arthritis (PsA). However, magnetic resonance (MR) imaging has uncovered bone marrow edema (BME) in healthy volunteers after vigorous exercise. The purpose of this study was to investigate MR images of the spine of PsA patients for changes in BME after HIIT. PsA patients went through 11 weeks of HIIT (N = 19, 4 men, median age 52 years) or no change in physical exercise habits (N = 20, 8 men, median age 45 years). We acquired scores for joint affection and pain and short tau inversion recovery (STIR) and T1-weighted MR images of the spine at baseline and after 11 weeks. MR images were evaluated for BME by a trained radiologist, by SpondyloArthritis Research Consortium of Canada (SPARCC) scoring, and by extraction of textural features. No significant changes of BME were detected in MR images of the spine after HIIT. This was consistent for MR image evaluation by a radiologist, by SPARCC, and by texture analysis. Values of textural features were significantly different in BME compared to healthy bone marrow. In conclusion, BME in spine was not changed after HIIT, supporting that HIIT is safe for PsA patients.


  • Automated analysis of immediate reliability of T2 and T2* relaxation times of hip joint cartilage from 3 T MR examinations

    by Jessica M. Bugeja, Shekhar S. Chandra, Aleš Neubert, Jurgen Fripp, Carly A. Lockard, Charles P. Ho, Stuart Crozier, Craig Engstrom


  • A lightweight rapid application development framework for biomedical image analysis

    by Shekhar S. Chandra, Jason A. Dowling, Craig Engstrom, Ying Xia, Anthony Paproki, Aleš Neubert, David Rivest-Hénault, Olivier Salvado, Stuart Crozier, Jurgen Fripp


  • Local contrast‐enhanced MR images via high dynamic range processing

    by Shekhar S. Chandra, Craig Engstrom, Jurgen Fripp, Ales Neubert, Jin Jin, Duncan Walker, Olivier Salvado, Charles Ho, Stuart Crozier

    Purpose: To develop a local contrast‐enhancing and feature‐preserving high dynamic range (HDR) image processing algorithm for multichannel and multisequence MR images of multiple body regions and tissues, and to evaluate its performance for structure visualization, bias field (correction) mitigation, and automated tissue segmentation.Methods: A multiscale‐shape and detail‐enhancement HDR‐MRI algorithm is applied to data sets of multichannel and multisequence MR images of the brain, knee, breast, and hip. In multisequence 3T hip images, agreement between automatic cartilage segmentations and corresponding synthesized HDR‐MRI series were computed for mean voxel overlap established from manual segmentations for a series of cases. Qualitative comparisons between the developed HDR‐MRI and standard synthesis methods were performed on multichannel 7T brain and knee data, and multisequence 3T breast and knee data.Results: The synthesized HDR‐MRI series provided excellent enhancement of fine‐scale structure from multiple scales and contrasts, while substantially reducing bias field effects in 7T brain gradient echo, T1 and T2 breast images and 7T knee multichannel images. Evaluation of the HDR‐MRI approach on 3T hip multisequence images showed superior outcomes for automatic cartilage segmentations with respect to manual segmentation, particularly around regions with hyperintense synovial fluid, across a set of 3D sequences.Conclusion: The successful combination of multichannel/sequence MR images into a single‐fused HDR‐MR image format provided consolidated visualization of tissues within 1 omnibus image, enhanced definition of thin, complex anatomical structures in the presence of variable or hyperintense signals, and improved tissue (cartilage) segmentation outcomes.


  • Comparison of 3D bone models of the knee joint derived from CT and 3T MR imaging

    by Aleš Neubert, Katharine J. Wilson, Craig Engstrom, Rachel K. Surowiec, Anthony Paproki, Nicholas Johnson, Stuart Crozier, Jurgen Fripp, Charles P. Ho


  • Evaluation and comparison of 3D intervertebral disc localization and segmentation methods for 3D T2 MR data: A grand challenge

    by Guoyan Zheng, Chengwen Chu, Daniel L. Belavý, Bulat Ibragimov, Robert Korez, Tomaž Vrtovec, Hugo Hutt, Richard Everson, Judith Meakin, Isabel Lŏpez Andrade, et al.


  • Automatic segmentation of the glenohumeral cartilages from magnetic resonance images

    by A. Neubert, Z. Yang, C. Engstrom, Y. Xia, M. W. Strudwick, S. S. Chandra, J. Fripp, S. Crozier

    Purpose: Magnetic resonance (MR) imaging plays a key role in investigating early degenerative disorders and traumatic injuries of the glenohumeral cartilages. Subtle morphometric and biochemical changes of potential relevance to clinical diagnosis, treatment planning, and evaluation can be assessed from measurements derived fromin vivoMR segmentation of the cartilages. However, segmentation of the glenohumeral cartilages, using approaches spanning manual to automated methods, is technically challenging, due to their thin, curved structure and overlapping intensities of surrounding tissues. Automatic segmentation of the glenohumeral cartilages from MR imaging is not at the same level compared to the weight‐bearing knee and hip joint cartilages despite the potential applications with respect to clinical investigation of shoulder disorders. In this work, the authors present a fully automated segmentation method for the glenohumeral cartilages using MR images of healthy shoulders.Methods: The method involves automated segmentation of the humerus and scapula bones using 3D active shape models, the extraction of the expected bone–cartilage interface, and cartilage segmentation using a graph‐based method. The cartilage segmentation uses localization, patient specific tissue estimation, and a model of the cartilage thickness variation. The accuracy of this method was experimentally validated using a leave‐one‐out scheme on a database of MR images acquired from 44 asymptomatic subjects with a true fast imaging with steady state precession sequence on a 3 T scanner (Siemens Trio) using a dedicated shoulder coil. The automated results were compared to manual segmentations from two experts (an experienced radiographer and an experienced musculoskeletal anatomist) using the Dice similarity coefficient (DSC) and mean absolute surface distance (MASD) metrics.Results: Accurate and precise bone segmentations were achieved with mean DSC of 0.98 and 0.93 for the humeral head and glenoid fossa, respectively. Mean DSC scores of 0.74 and 0.72 were obtained for the humeral and glenoid cartilage volumes, respectively. The manual interobserver reliability evaluated by DSC was 0.80 ± 0.03 and 0.76 ± 0.04 for the two cartilages, implying that the automated results were within an acceptable 10% difference. The MASD between the automatic and the corresponding manual cartilage segmentations was less than 0.4 mm (previous studies reported mean cartilage thickness of 1.3 mm).Conclusions: This work shows the feasibility of volumetric segmentation and separation of the glenohumeral cartilages from MR images. To their knowledge, this is the first fully automated algorithm for volumetric segmentation of the individual glenohumeral cartilages from MR images. The approach was validated against manual segmentations from experienced analysts. In future work, the approach will be validated on imaging datasets acquired with various MR contrasts in patients.


  • Incremental shape learning of 3D surfaces of the knee, data from the osteoarthritis initiative

    by Ales Neubert, Ibrahim Naser, Anthony Paproki, Craig Engstrom, Jurgen Fripp, Stuart Crozier, Shekhar S. Chandra

    Traditional shape learning of medical image data has been implemented via Principal Component Analysis (PCA). These PCA based statistical shape models batch process all shapes at once to generate a fixed model of shape variation as principal components, which may require significant computation resources for large number of shapes. This paper applies incremental PCA (IPCA) on a dataset of 728 surfaces (derived from magnetic resonance imaging examinations displaying the articulating bones of the knee joint) that can efficiently adapt to changes in training sets. After comparing the compactness and the accuracy of shape reconstruction of both batch PCA and IPCA models, our results show that IPCA produces a model comparable to batch PCA in terms of compactness and applicability to shape reconstruction, while requiring considerably shorter processing time and computer memory for computation.