John Atyeo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John Atyeo has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Kenny Wu
Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
4 shared publications- Thomas Eade
Northern Sydney Clinical School, Faculty of Medicine and Health The University of Sydney Sydney New South Wales Australia
4 shared publications Andrew Le
Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
3 shared publicationsMarita Morgia
Department of Radiation Oncology, Northern Sydney Cancer Centre Royal North Shore Hospital Sydney New South Wales Australia
3 shared publicationsMark Stevens
Northern Sydney Cancer Centre Radiation Oncology Department, Royal North Shore Hospital St Leonards New South Wales Australia
3 shared publications- Meegan Shepherd
Northern Sydney Cancer Centre Royal North Shore Hospital St Leonards New South Wales Australia
3 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (3) , 352-358
Improving Equity of Care for Culturally and Linguistically Diverse Patients: Utilising Multilingual Software to Support Breath‐Hold Breast Radiation Therapy
Breath‐hold techniques, including Deep Inspiration Breath Hold (DIBH) and Exhalation Breath Hold (EBH), are commonly used in radiation therapy to reduce radiation exposure to organs at risk while maintaining accurate tumour targeting. However, high failure rates during breath‐hold simulations have been associated with patient anxiety and insufficient preparation—particularly when instruction is given only 20 min prior to the procedure. These challenges are amplified for patients from culturally and linguistically diverse (CALD) backgrounds. To address this, a multilingual mobile application (app) has been developed to improve patient education, communication, and compliance, with a particular focus on supporting CALD patients. Replacing traditional pamphlets with interactive instructional videos, visual aids, and real‐time translation in seven languages, the app allows patients to familiarise themselves with breath‐hold techniques before their Computed Tomography (CT) simulation. A General Radiation Therapy (RT) section in the app further supports communication between radiation therapists (RTs) and their patients by providing translated commands for standard patient positioning and movement instructions, improving accuracy and workflow efficiency. The app integrates with in‐room sound systems, allowing RTs to provide remote coaching while maintaining clear and consistent communication. Additionally, the Frequently Asked Questions (FAQ) section of the app addresses common concerns that patients have about radiation therapy, helping them gain a better understanding with the possibility of reducing anxiety. The app has been implemented at the Northern Sydney Cancer Centre (NSCC) and is expected to improve patient compliance in breath‐hold techniques and streamline clinical workflows.
- 10 June 2026
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (3) , 352-358
Open AccessImproving Equity of Care for Culturally and Linguistically Diverse Patients: Utilising Multilingual Software to Support Breath‐Hold Breast Radiation Therapy
Breath‐hold techniques, including Deep Inspiration Breath Hold (DIBH) and Exhalation Breath Hold (EBH), are commonly used in radiation therapy to reduce radiation exposure to organs at risk while maintaining accurate tumour targeting. However, high failure rates during breath‐hold simulations have been associated with patient anxiety and insufficient preparation—particularly when instruction is given only 20 min prior to the procedure. These challenges are amplified for patients from culturally and linguistically diverse (CALD) backgrounds. To address this, a multilingual mobile application (app) has been developed to improve patient education, communication, and compliance, with a particular focus on supporting CALD patients. Replacing traditional pamphlets with interactive instructional videos, visual aids, and real‐time translation in seven languages, the app allows patients to familiarise themselves with breath‐hold techniques before their Computed Tomography (CT) simulation. A General Radiation Therapy (RT) section in the app further supports communication between radiation therapists (RTs) and their patients by providing translated commands for standard patient positioning and movement instructions, improving accuracy and workflow efficiency. The app integrates with in‐room sound systems, allowing RTs to provide remote coaching while maintaining clear and consistent communication. Additionally, the Frequently Asked Questions (FAQ) section of the app addresses common concerns that patients have about radiation therapy, helping them gain a better understanding with the possibility of reducing anxiety. The app has been implemented at the Northern Sydney Cancer Centre (NSCC) and is expected to improve patient compliance in breath‐hold techniques and streamline clinical workflows.
- Open Access
- 27 March 2026
- Published by Elsevier in Physica Medica
- Vol. 145, 105774
Dosimetric comparison of intensity modulated proton therapy and knowledge-based volumetric arc therapy for left-sided breast cancer
- 27 March 2026
- Published by Elsevier in Physica Medica
- Vol. 145, 105774
Open AccessDosimetric comparison of intensity modulated proton therapy and knowledge-based volumetric arc therapy for left-sided breast cancer
- Open Access
- 23 December 2025
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (1) , 79-86
Improving Patient‐Centred Care and Clinical Pathways: The Role of the Patient Care Radiation Therapist ( PCRT )
Introduction: A patient's cancer care journey can be complex and difficult to navigate. A new model of radiation therapist‐driven patient care, the Patient Care Radiation Therapist (PCRT), was established in 2019. The aim of this study was to assess multidisciplinary staff knowledge and perceptions of the efficacy of the current PCRT role and potential barriers to expanding the role. Methods: A survey incorporating quantitative and qualitative research strategies was used to collect interdisciplinary team members' perceptions of the PCRT role. Data were assessed by a five‐member team and included both quantitative analysis and theme generation through qualitative analysis. Results: From 118 surveys distributed, the response rate was 55%, with representation from all craft groups. Of the 65 who responded, 94% perceived PCRTs to positively support their clinical roles to improve patient care pathways. Effective communication skills and high‐level interpersonal skills were considered the most important skills required by PCRTs to fulfil their role. In analysing the qualitative data and establishing themes, four key areas emerged that included personalised care, care coordination, effective communication skills and patient education. Conclusion: Identifying gaps in our current cancer services and utilising technical knowledge combined with patient care skills, the PCRT can influence patient care pathways, improve efficiencies and improve the patient experience. To achieve this, clear role delineation and communication between the multidisciplinary team are paramount.
- 23 December 2025
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 73 (1) , 79-86
Open AccessImproving Patient‐Centred Care and Clinical Pathways: The Role of the Patient Care Radiation Therapist ( PCRT )
Introduction: A patient's cancer care journey can be complex and difficult to navigate. A new model of radiation therapist‐driven patient care, the Patient Care Radiation Therapist (PCRT), was established in 2019. The aim of this study was to assess multidisciplinary staff knowledge and perceptions of the efficacy of the current PCRT role and potential barriers to expanding the role. Methods: A survey incorporating quantitative and qualitative research strategies was used to collect interdisciplinary team members' perceptions of the PCRT role. Data were assessed by a five‐member team and included both quantitative analysis and theme generation through qualitative analysis. Results: From 118 surveys distributed, the response rate was 55%, with representation from all craft groups. Of the 65 who responded, 94% perceived PCRTs to positively support their clinical roles to improve patient care pathways. Effective communication skills and high‐level interpersonal skills were considered the most important skills required by PCRTs to fulfil their role. In analysing the qualitative data and establishing themes, four key areas emerged that included personalised care, care coordination, effective communication skills and patient education. Conclusion: Identifying gaps in our current cancer services and utilising technical knowledge combined with patient care skills, the PCRT can influence patient care pathways, improve efficiencies and improve the patient experience. To achieve this, clear role delineation and communication between the multidisciplinary team are paramount.
- Open Access
- 28 August 2025
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 72 (Suppl 2) , S79-S84
The Value of Radiation Therapists in Online Adaptive Radiotherapy
Value‐based health care (VBHC) is an evolving paradigm in healthcare that prioritises patient outcomes relative to the costs incurred. VBHC emphasises efficiency, quality, and patient satisfaction as metrics and determinants of healthcare. A VBHC approach is becoming increasingly significant as healthcare systems worldwide grapple with rising costs, staff shortages, and the ongoing need for improved patient care. Online adaptive radiotherapy (oART) is a promising innovation in radiation oncology, allowing for the adaptation of radiation treatment plans to account for daily anatomical changes. This innovation has the potential to improve patient outcomes; however, it requires investment in the technology, manpower, and training to deliver an adaptive radiotherapy service. This commentary aims to explore the role of radiation therapists (RTs) in oART, using RT‐led workflows within the context of the broader models of care that involve radiation oncologists and multidisciplinary teams. This commentary also aims to highlight the potential benefits and challenges of adopting an RT‐led approach within VBHC principles, focusing on key themes such as treatment accuracy, patient satisfaction, training, and cost implications.
- 28 August 2025
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 72 (Suppl 2) , S79-S84
Open AccessThe Value of Radiation Therapists in Online Adaptive Radiotherapy
Value‐based health care (VBHC) is an evolving paradigm in healthcare that prioritises patient outcomes relative to the costs incurred. VBHC emphasises efficiency, quality, and patient satisfaction as metrics and determinants of healthcare. A VBHC approach is becoming increasingly significant as healthcare systems worldwide grapple with rising costs, staff shortages, and the ongoing need for improved patient care. Online adaptive radiotherapy (oART) is a promising innovation in radiation oncology, allowing for the adaptation of radiation treatment plans to account for daily anatomical changes. This innovation has the potential to improve patient outcomes; however, it requires investment in the technology, manpower, and training to deliver an adaptive radiotherapy service. This commentary aims to explore the role of radiation therapists (RTs) in oART, using RT‐led workflows within the context of the broader models of care that involve radiation oncologists and multidisciplinary teams. This commentary also aims to highlight the potential benefits and challenges of adopting an RT‐led approach within VBHC principles, focusing on key themes such as treatment accuracy, patient satisfaction, training, and cost implications.
- Open Access
- 19 June 2024
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (4) , 529-539
Comparing immobilisation devices in gynaecological external beam radiotherapy: improving inter‐fraction reproducibility of pelvic tilt
Introduction: The aim was to determine which immobilisation device improved inter‐fraction reproducibly of pelvic tilt and required the least pre‐treatment setup and planning interventions.Methods: Sixteen patients were retrospectively reviewed, eight immobilised using the BodyFIX system (BodyFIX®, Elekta, Stockholm, Sweden) and eight using the Butterfly Board (BB) (Bionix Radiation Therapy, Toledo, OH, USA). The daily pre‐treatment images were reviewed to assess setup variations between each patient and groups for pelvic tilt, pubic symphysis, sacral promontory and the fifth lumbar spine (L5).Results: Compared with the planning CT, pelvic tilt for most patients was within ±2° using the BodyFIX and ± 4° for the BB. The Butterfly Board had a slightly higher variance both for patient‐to‐patient (standard deviation of the systematic error) and day‐to‐day error (standard deviation of the random error). Variance in position between individual patients and the two stabilisation devices were minimal in the anterior–posterior (AP) and superior–inferior (SI) direction for the pubic symphysis, sacral promontory and L5 spine. Re‐imaged fractions due to pelvic tilt reduced by about half when BodyFIX was used (39.1% BB, 19.4% BodyFIX). One patient treated with the BB required a re‐scan for pelvic tilt. Three patients required a re‐scan for body contour variations (two using BodyFIX and one with the BB).Conclusions: BodyFIX resulted in a more accurate inter‐fraction setup and efficient treatment and is used as the standard stabilisation for gynaecological patients at our centre. It reduced the pelvic tilt variance and reduced the need for re‐imaging pre‐treatment by half.
- 19 June 2024
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 71 (4) , 529-539
Open AccessComparing immobilisation devices in gynaecological external beam radiotherapy: improving inter‐fraction reproducibility of pelvic tilt
Introduction: The aim was to determine which immobilisation device improved inter‐fraction reproducibly of pelvic tilt and required the least pre‐treatment setup and planning interventions.Methods: Sixteen patients were retrospectively reviewed, eight immobilised using the BodyFIX system (BodyFIX®, Elekta, Stockholm, Sweden) and eight using the Butterfly Board (BB) (Bionix Radiation Therapy, Toledo, OH, USA). The daily pre‐treatment images were reviewed to assess setup variations between each patient and groups for pelvic tilt, pubic symphysis, sacral promontory and the fifth lumbar spine (L5).Results: Compared with the planning CT, pelvic tilt for most patients was within ±2° using the BodyFIX and ± 4° for the BB. The Butterfly Board had a slightly higher variance both for patient‐to‐patient (standard deviation of the systematic error) and day‐to‐day error (standard deviation of the random error). Variance in position between individual patients and the two stabilisation devices were minimal in the anterior–posterior (AP) and superior–inferior (SI) direction for the pubic symphysis, sacral promontory and L5 spine. Re‐imaged fractions due to pelvic tilt reduced by about half when BodyFIX was used (39.1% BB, 19.4% BodyFIX). One patient treated with the BB required a re‐scan for pelvic tilt. Three patients required a re‐scan for body contour variations (two using BodyFIX and one with the BB).Conclusions: BodyFIX resulted in a more accurate inter‐fraction setup and efficient treatment and is used as the standard stabilisation for gynaecological patients at our centre. It reduced the pelvic tilt variance and reduced the need for re‐imaging pre‐treatment by half.
- Open Access
- 1 December 2021
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 68 (4) , 364-370
Improving efficiency in the radiation management of multiple brain metastases using a knowledge-based planning solution for single-isocentre volumetric modulated arc therapy (VMAT) technique
Introduction: This study aimed to develop a single-isocentre volumetric modulated arc therapy (si-VMAT) technique for multiple brain metastases using knowledge-based planning software, comparing it with a multipleisocentre stereotactic radiosurgery (mi-SRS) planning approach. Methods: Twenty-six si-VMAT plans were created and uploaded into RapidPlan (TM) (RP) to create a si-VMAT model. Ten patients, with 2 to 6 metastases (mets), were planned with a si-VMAT technique utilising RP, and a mi-SRS technique on Brainlab iPlan. Paddick Conformity Index (PCI) was used to compare conformity. The volumes of the brain receiving 15Gy, 12Gy, 10Gy, 7.5Gy and 3Gy were also compared. Retrospective treatment times from the last eight patients treated were averaged for pre-imaging and beam on time to calculate treatment times for both techniques. Results: There was a significant difference in the PCI scores for the mi-SRS plans (M = 0.667, SD = 0.114) and si-VMAT plans (M = 0.728, SD = 0.088), with PCI values suggesting better prescription dose conformity with the si-VMAT technique (P = 0.014). Percentage of total brain volume receiving low-dose wash at four of the five different dose levels was significantly less (P < 0.05) with mi-SRS. Average time to treat a single met with current mi-SRS technique is 25.7 min, with each additional met requiring this same amount of time. The average time to treat 2- 3 mets using si-VMAT would be 25.3 min and 4+ metastases 33.5 min. Conclusion: A knowledge-based si-VMAT approach was efficient in planning and treating multi metastases while achieving clinically acceptable dosimetry with respect to dose conformity and low-dose fall off.
- 1 December 2021
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 68 (4) , 364-370
Open AccessImproving efficiency in the radiation management of multiple brain metastases using a knowledge-based planning solution for single-isocentre volumetric modulated arc therapy (VMAT) technique
Introduction: This study aimed to develop a single-isocentre volumetric modulated arc therapy (si-VMAT) technique for multiple brain metastases using knowledge-based planning software, comparing it with a multipleisocentre stereotactic radiosurgery (mi-SRS) planning approach. Methods: Twenty-six si-VMAT plans were created and uploaded into RapidPlan (TM) (RP) to create a si-VMAT model. Ten patients, with 2 to 6 metastases (mets), were planned with a si-VMAT technique utilising RP, and a mi-SRS technique on Brainlab iPlan. Paddick Conformity Index (PCI) was used to compare conformity. The volumes of the brain receiving 15Gy, 12Gy, 10Gy, 7.5Gy and 3Gy were also compared. Retrospective treatment times from the last eight patients treated were averaged for pre-imaging and beam on time to calculate treatment times for both techniques. Results: There was a significant difference in the PCI scores for the mi-SRS plans (M = 0.667, SD = 0.114) and si-VMAT plans (M = 0.728, SD = 0.088), with PCI values suggesting better prescription dose conformity with the si-VMAT technique (P = 0.014). Percentage of total brain volume receiving low-dose wash at four of the five different dose levels was significantly less (P < 0.05) with mi-SRS. Average time to treat a single met with current mi-SRS technique is 25.7 min, with each additional met requiring this same amount of time. The average time to treat 2- 3 mets using si-VMAT would be 25.3 min and 4+ metastases 33.5 min. Conclusion: A knowledge-based si-VMAT approach was efficient in planning and treating multi metastases while achieving clinically acceptable dosimetry with respect to dose conformity and low-dose fall off.
- Open Access
- 6 May 2021
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 69 (1) , 75-84
Potential gains: Comparison of a mono‐isocentric three‐dimensional conformal radiotherapy (3D‐CRT) planning technique to hybrid intensity‐modulated radiotherapy (hIMRT) to the whole breast and supraclavicular fossa (SCF) region
Introduction Until late 2018, standard of practice at the Northern Sydney Cancer Centre (NSCC) for breast and nodal treatment was a conformal mono‐isocentric technique. A planning study comparing an existing mono‐isocentric three‐dimensional conformal radiotherapy (3D‐CRT) planning technique to a hybrid intensity‐modulated radiotherapy (hIMRT) approach for the whole breast and supraclavicular fossa (SCF) region was undertaken with the aim to improve plan quality by improving dose conformity/homogeneity across target volumes and reducing hotspots outside the target. Methods A cohort of 17 patients was retrospectively planned using the proposed hIMRT technique, keeping the same planning constraints as the original treated breast and SCF 3D‐CRT plan and normalising the 3D‐CRT plans to achieve minimum breast/SCF target coverage to compare organs at risk (OARs). Normal tissue index (NTI) and homogeneity index (HI) were compared for plan quality as well as for evaluating OARs. Results The hIMRT technique showed statistically significant improvements in NTI and HI, as well as improvement in maximum brachial plexus and thyroid doses. There was a negligible increase in maximum oesophagus dose which could be improved if used in optimisation. Other OAR doses in the irradiated region were comparable to the 3D‐CRT plans, however maximum doses were reduced overall. Conclusion The hIMRT planning technique maintained clinically acceptable doses to OARs and reduced normal tissue dose while maintaining equivalent dose coverage to breast and SCF planning target volumes with improved conformity and homogeneity. The reduction in maximum doses promotes a favourable toxicity profile, with potential benefit of improved long‐term cosmesis.
- 6 May 2021
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 69 (1) , 75-84
Open AccessPotential gains: Comparison of a mono‐isocentric three‐dimensional conformal radiotherapy (3D‐CRT) planning technique to hybrid intensity‐modulated radiotherapy (hIMRT) to the whole breast and supraclavicular fossa (SCF) region
Introduction Until late 2018, standard of practice at the Northern Sydney Cancer Centre (NSCC) for breast and nodal treatment was a conformal mono‐isocentric technique. A planning study comparing an existing mono‐isocentric three‐dimensional conformal radiotherapy (3D‐CRT) planning technique to a hybrid intensity‐modulated radiotherapy (hIMRT) approach for the whole breast and supraclavicular fossa (SCF) region was undertaken with the aim to improve plan quality by improving dose conformity/homogeneity across target volumes and reducing hotspots outside the target. Methods A cohort of 17 patients was retrospectively planned using the proposed hIMRT technique, keeping the same planning constraints as the original treated breast and SCF 3D‐CRT plan and normalising the 3D‐CRT plans to achieve minimum breast/SCF target coverage to compare organs at risk (OARs). Normal tissue index (NTI) and homogeneity index (HI) were compared for plan quality as well as for evaluating OARs. Results The hIMRT technique showed statistically significant improvements in NTI and HI, as well as improvement in maximum brachial plexus and thyroid doses. There was a negligible increase in maximum oesophagus dose which could be improved if used in optimisation. Other OAR doses in the irradiated region were comparable to the 3D‐CRT plans, however maximum doses were reduced overall. Conclusion The hIMRT planning technique maintained clinically acceptable doses to OARs and reduced normal tissue dose while maintaining equivalent dose coverage to breast and SCF planning target volumes with improved conformity and homogeneity. The reduction in maximum doses promotes a favourable toxicity profile, with potential benefit of improved long‐term cosmesis.
- Open Access
- 1 December 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (4) , 310-317
Rolling out RapidPlan: What we've learnt
Introduction: RapidPlan (RP), a knowledge-based planning system, aims to consistently improve plan quality and efficiency in radiotherapy. During the early stages of implementation, some of the challenges include knowing how to optimally train a model and how to integrate RP into a department. We discuss our experience with the implementation of RP into our institution. Methods: We reviewed all patients planned using RP over a 7-month period following inception in our department. Our primary outcome was clinically acceptable plans (used for treatment) with secondary outcomes including model performance and a comparison of efficiency and plan quality between RP and manual planning (MP). Results: Between November 2017 and May 2018, 496 patients were simulated, of which 217 (43.8%) had an available model. RP successfully created a clinically acceptable plan in 87.2% of eligible patients. The individual success of the 24 models ranged from 50% to 100%, with more than 90% success in 15 (62.5%) of the models. In 40% of plans, success was achieved on the 1st optimisation. The overall planning time with RP was reduced by up to 95% compared with MP times. The quality of the RP plans was at least equivalent to historical MP plans in terms of target coverage and organ at risk constraints. Conclusion: While initially time-consuming and resource-intensive to implement, plans optimised with RP demonstrate clinically acceptable plan quality, while significantly improving the efficiency of a department, suggesting RP and its application is a highly effective tool in clinical practice.
- 1 December 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (4) , 310-317
Open AccessRolling out RapidPlan: What we've learnt
Introduction: RapidPlan (RP), a knowledge-based planning system, aims to consistently improve plan quality and efficiency in radiotherapy. During the early stages of implementation, some of the challenges include knowing how to optimally train a model and how to integrate RP into a department. We discuss our experience with the implementation of RP into our institution. Methods: We reviewed all patients planned using RP over a 7-month period following inception in our department. Our primary outcome was clinically acceptable plans (used for treatment) with secondary outcomes including model performance and a comparison of efficiency and plan quality between RP and manual planning (MP). Results: Between November 2017 and May 2018, 496 patients were simulated, of which 217 (43.8%) had an available model. RP successfully created a clinically acceptable plan in 87.2% of eligible patients. The individual success of the 24 models ranged from 50% to 100%, with more than 90% success in 15 (62.5%) of the models. In 40% of plans, success was achieved on the 1st optimisation. The overall planning time with RP was reduced by up to 95% compared with MP times. The quality of the RP plans was at least equivalent to historical MP plans in terms of target coverage and organ at risk constraints. Conclusion: While initially time-consuming and resource-intensive to implement, plans optimised with RP demonstrate clinically acceptable plan quality, while significantly improving the efficiency of a department, suggesting RP and its application is a highly effective tool in clinical practice.
- Open Access
- 25 May 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (3) , 217-224
Developing knowledge‐based planning for gynaecological and rectal cancers: a clinical validation of RapidPlan™
Introduction: To create and clinically validate knowledge‐based planning (KBP) models for gynaecologic (GYN) and rectal cancer patients. Assessment of ecologic generalisability and predictive validity of conventional planning versus single calculation KBP was reviewed against practical metrics of planning time (PT) and radiation oncologist plan preference.Method: Study cohorts were 34 and 42 consecutively treated GYN and rectal cancer patients dosimetrically archived within the centre’s research databank. For model training, structures and dose distributions from 22 and 32 GYN and rectal volumetric‐modulated arc therapy (VMAT) plans were used in RapidPlan™. Prescription doses ranged from 45 to 60Gy in 25 fractions using a simultaneous integrated boost to 2–4 targets and up to 9 organ‐at‐risk volumes. For model validation, 12 GYN and 10 rectal were independent of the archive and a single pass KBP VMAT plan was created. Each plan was evaluated against the archived treated plan under blinded conditions for radiation oncologist preference using standard dosimetric quality parameters.Results: All 22 plans generated in the KBP validation cohort met pre‐set GYN and rectal cancer dosimetric quality metrics. Fifty per cent of GYN plans and eighty per cent of rectal plans were judged superior to the manually optimised plans. KBP reduced PT considerably for both tumour sites.Conclusion: Single pass KBP for GYN and rectal cancer patients produced clinically acceptable treatment plans which were non‐inferior to conventionally optimised plans in 14 of 22 cases. Efficiencies captured by KBP will have predictable impacts on institutional workflows and resource allocation to facilitate adaptive planning.
- 25 May 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (3) , 217-224
Open AccessDeveloping knowledge‐based planning for gynaecological and rectal cancers: a clinical validation of RapidPlan™
Introduction: To create and clinically validate knowledge‐based planning (KBP) models for gynaecologic (GYN) and rectal cancer patients. Assessment of ecologic generalisability and predictive validity of conventional planning versus single calculation KBP was reviewed against practical metrics of planning time (PT) and radiation oncologist plan preference.Method: Study cohorts were 34 and 42 consecutively treated GYN and rectal cancer patients dosimetrically archived within the centre’s research databank. For model training, structures and dose distributions from 22 and 32 GYN and rectal volumetric‐modulated arc therapy (VMAT) plans were used in RapidPlan™. Prescription doses ranged from 45 to 60Gy in 25 fractions using a simultaneous integrated boost to 2–4 targets and up to 9 organ‐at‐risk volumes. For model validation, 12 GYN and 10 rectal were independent of the archive and a single pass KBP VMAT plan was created. Each plan was evaluated against the archived treated plan under blinded conditions for radiation oncologist preference using standard dosimetric quality parameters.Results: All 22 plans generated in the KBP validation cohort met pre‐set GYN and rectal cancer dosimetric quality metrics. Fifty per cent of GYN plans and eighty per cent of rectal plans were judged superior to the manually optimised plans. KBP reduced PT considerably for both tumour sites.Conclusion: Single pass KBP for GYN and rectal cancer patients produced clinically acceptable treatment plans which were non‐inferior to conventionally optimised plans in 14 of 22 cases. Efficiencies captured by KBP will have predictable impacts on institutional workflows and resource allocation to facilitate adaptive planning.
- Open Access
- 11 February 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (1) , 80-86
Parotid sparing in RapidPlan Oropharynx models: To split or not to split
Introduction: Differences in knowledge and experience, patient anatomy and tumour location and manipulation of inverse planning objectives and priorities will lead to a variability in the quality of radiation planning. The aim of this study was to investigate whether parotid glands should be treated as separate or combined structures when using knowledge‐based planning (KBP) to create oropharyngeal plans, based on the dose they receive.Method: Two separate RapidPlan (RP) models were created using the same 70 radical oropharyngeal patients. The ‘separated model’ divided the parotids into ipsilateral and contralateral structures. The ‘combined model’ did not separate the parotids. The models were independently validated using 20 patients not included in the models. The same dose constraints and priorities were applied to planning target volumes (PTVs) and organs at risk (OARs) for all plans. An auto‐generated line objective and priority was applied in both models, with parotid mean dose and V50 doses evaluated and compared.Results: Plans optimised using the combined model resulted in lower ipsilateral mean doses and lower V50 doses in 80% and 75% of cases, respectively. Fifty‐five per cent of plans produced lower mean doses for the contralateral parotid when optimised using the combined model, while lower V50 doses were evenly split between the models.Conclusion: Combining the data for both parotids into one RP model resulted in better ipsilateral parotid sparing. Results also suggest that a combined parotid model will spare dose to the contralateral parotid; however, further investigation is required to confirm these results.
- 11 February 2020
- Published by Wiley in Journal of Medical Radiation Sciences
- Vol. 67 (1) , 80-86
Open AccessParotid sparing in RapidPlan Oropharynx models: To split or not to split
Introduction: Differences in knowledge and experience, patient anatomy and tumour location and manipulation of inverse planning objectives and priorities will lead to a variability in the quality of radiation planning. The aim of this study was to investigate whether parotid glands should be treated as separate or combined structures when using knowledge‐based planning (KBP) to create oropharyngeal plans, based on the dose they receive.Method: Two separate RapidPlan (RP) models were created using the same 70 radical oropharyngeal patients. The ‘separated model’ divided the parotids into ipsilateral and contralateral structures. The ‘combined model’ did not separate the parotids. The models were independently validated using 20 patients not included in the models. The same dose constraints and priorities were applied to planning target volumes (PTVs) and organs at risk (OARs) for all plans. An auto‐generated line objective and priority was applied in both models, with parotid mean dose and V50 doses evaluated and compared.Results: Plans optimised using the combined model resulted in lower ipsilateral mean doses and lower V50 doses in 80% and 75% of cases, respectively. Fifty‐five per cent of plans produced lower mean doses for the contralateral parotid when optimised using the combined model, while lower V50 doses were evenly split between the models.Conclusion: Combining the data for both parotids into one RP model resulted in better ipsilateral parotid sparing. Results also suggest that a combined parotid model will spare dose to the contralateral parotid; however, further investigation is required to confirm these results.