DMDean Morton

Dean Morton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dean Morton has a total of 133 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Retention characteristics of individually milled bar systems with customized patrices: An in vitro comparison of electroplated and friction‐based retention concepts

    by Helene Bacher, Sebastian Hinz, Tobias Bensel, Daniel Voigt, Dean Morton, Arne F. Boeckler

    Purpose: This in vitro study examined the initial and long‐term retention behavior of individually milled bar (IMB) systems combined with customized patrices (CPs), contrasting electroplated patrices (EP), and friction pin patrices (FPP) concepts. Retention values were related to a previously reported laboratory reference threshold of 5 N. Given the exploratory nature of the design, the study aimed to describe material‐dependent trends rather than to establish clinical sufficiency. Materials and Methods: Seven IMB–CP combinations were fabricated—four with EP (gold, non‐precious alloy, titanium, and zirconia) and three with FPP (non‐precious alloy, titanium, and zirconia) ( n = 5 per group). Each bar was mounted on two implants embedded in epoxy resin casts and subjected to 5000 insertion–removal cycles in artificial saliva (23°C) using a universal testing machine. Retention forces were continuously recorded, and surface alterations were assessed by profilometry, light microscopy, and environmental scanning electron microscopy. Material wear was determined gravimetrically. Data were analyzed after assessment of normality (Shapiro–Wilk); initial and final retention forces were compared within groups using paired t ‐tests or Wilcoxon signed‐rank tests ( α = 0.05). No inferential comparisons between materials or retention concepts were performed; differences between groups are reported descriptively. Results: Initial retention ranged from 5.4 N (titanium–titanium FPP) to 21.7 N (non‐precious EP), all exceeding the 5 N laboratory reference threshold. After cyclic loading, final retention ranged from 2.4 N (TF) to 18.5 N (NG). The change in retention (Δ F = F _final − F _initial) varied from −10.1 to +2.1 N across groups. Surface roughness decreased for most EP systems, whereas FPP systems showed greater wear and predictable retention loss. Material change ranged from 8 to 34 µg (IMB) and 36 to 180 µg (CP). Conclusions: Under the tested laboratory conditions, all IMB–CP systems showed initial retention forces above the 5 N reference threshold. After 5000 insertion–removal cycles, the titanium–titanium FPP combination exhibited the lowest retention and fell below this threshold, whereas the remaining systems maintained retention values above it. EP showed stable or slightly increased retention with minimal measured wear, whereas FPP showed greater, predictable wear‐related retention loss. These exploratory observations demonstrate that material pairing plays an important role in retention behavior under in vitro conditions, whereas clinical performance, maintenance requirements, and long‐term success should be evaluated in future clinical studies.

  • Open Access

    Virtual articulation using sequential mandibular intraoral scans and computational functional rotation reference determination-Proof-of-concept.

    by Mohamed Sherif Omar, Chao-Chieh Yang, Dean Morton, Wei-Shao Lin

    Virtual articulators require accurate spatial orientation of digital casts for meaningful occlusal analysis during prosthesis design. Current methods for establishing this orientation rely on facial scanning, cone-beam computed tomography, electronic jaw tracking, or arbitrary population-based values. This proof-of-concept technique presents a computational method for determining a functional rotation reference from sequential mandibular intraoral scans captured at controlled opening increments using leaf gauges. The algorithm identifies regions exhibiting minimal translation during jaw opening through systematic grid search within anatomically defined boundaries posterior and superior to the molar positions. Points demonstrating negligible displacement while surrounding structures rotate lie geometrically on or near a rotation axis; a best fit line through their distribution establishes the functional rotation reference. This reference is then transformed to align with the intercondylar axis coordinates of the virtual articulator for digital cast mounting. Forward validation demonstrated root mean square deviations averaging 0.14 mm between simulated and actual scan positions. The technique was implemented for multiple virtual articulator systems including Denar Mark 330, Artex CR, and Stratos 300. This method enables patient-specific virtual articulation using only standard intraoral scanning equipment and leaf gauges, eliminating dependence on supplementary registration hardware.


  • Open Access

    Comparison of tooth fracture load between different conventional and CAD‐CAM denture base materials

    by Eman Al Kaba, Amal Alfaraj, Tien‐Min G. Chu, Dean Morton, Dhafer Alqahtani, Wei‐Shao Lin, Chao‐Chieh Yang

    Purpose: To assess the fracture load at the tooth‐denture base interface in dentures fabricated using three different production methods: compression mold, computer‐aided design and computer‐aided manufacturing (CAD‐CAM) milled (monolithic and bonded), and 3D‐ printed dentures (monolithic and bonded). Materials and Methods: Seven groups ( n = 10/group) were fabricated using a standardized segmented digital denture design that included tooth #8. Fabrication techniques included conventional compression molding, single, two‐disc milling or with bonded tooth designs, and 3D printing monolithic or with bonded tooth designs, utilizing either prefabricated, milled, or 3D‐printed teeth. Specimens were embedded in cylindrical molds exposing 2 mm of the denture base and subjected to fracture load testing. Failure modes were analyzed via scanning electron microscopy and classified as adhesive, cohesive, or mixed. One‐way analysis of variance with Fisher's LSD was used to compare fracture loads among groups. Results: Statistical analysis revealed significant differences in fracture load among the seven denture fabrication methods ( p < 0.001). The monolithic milled group demonstrated the highest fracture load (504.7 ± 76 N) and reliability, as confirmed by Weibull analysis. Both 3D‐printed denture bases with bonded teeth groups also showed high fracture load values (361.2 ± 0.4 and 348.7 ± 0.8 N, respectively), outperforming the conventional group ( p < 0.001, p = 0.002). Milled base with bonded milled tooth and monolithic print exhibited moderate fracture load. In contrast, compression‐molded and milled base with bonded prefabricated tooth exhibited the lowest fracture load (251.7 ± 69.6 and 232.8 ± 47.7 N, respectively). Fracture modes varied, with cohesive failures more evident in stronger groups and adhesive or mixed failures in weaker ones. Conclusion: Denture fabrication method had a significant effect on tooth–base fracture load. Monolithic CAD‐CAM‐milled denture outperformed all other groups in denture teeth fracture load. 3D‐printed techniques with optimized bonding also achieved high fracture load exceeding conventional compression‐molded dentures.

  • Open Access

    Implementing 3D‐printed indexing devices and contemporary scanning techniques for complete‐arch implant‐supported rehabilitations: A clinical case report

    by Francisco X. Azpiazu‐Flores, Metavi Phuckdeedindan, Abdullah M. Aldosari, Chao‐Chieh Yang, Dean Morton, Wei‐Shao Lin

    A sixty‐eight‐year‐old male presented to the dental clinic seeking a complete mouth rehabilitation. He exhibited generalized dental caries, dental staining, cervical lesions, fremitus, and anterior wear. After declining tooth‐retaining options, he elected full‐mouth extractions with immediately loaded implant‐supported prostheses. A hybrid workflow, incorporating both digital and conventional steps, was used to plan treatment. The cone‐beam computed tomography–derived anatomical data were integrated with the articulated diagnostic casts using a custom three‑dimensional (3D)‐printed hexagonal indexing device. The maxillary teeth were digitally removed to generate an edentulous cast, a cast of the maxilla generated from the segmented‐CBCT data, and an artificial tooth arrangement. Subsequently, 3D‐printed stackable surgical guides were fabricated to support extractions, osteotomy preparation, implant placement, and delivery of a milled polymethyl methacrylate interim prosthesis. A similar hybrid workflow was used for the mandibular arch, with an updated diagnostic maxillary arch compensating for occlusal changes introduced during the fabrication of the maxillary interim prosthesis. Implant positions were recorded using non‐splinted and splinted intraoral scanning techniques, and verification casts were articulated to support fabrication of the definitive prostheses. The definitive, complete arch monolithic zirconia restorations demonstrated accurate fit, stable occlusion, and favorable soft‐tissue contours. At the 1‐year follow‐up, radiographs showed stable peri‐implant bone levels and clinically healthy peri‐implant tissues, indicating favorable adaptation to the implant‐supported prostheses.

  • Open Access

    Scanner‐agnostic dynamic jaw motion generation from virtual static excursive records using open‐source Python‐based artificial intelligence (AI) interpolation

    by Mohamed Sherif Omar, Chao‐Chieh Yang, Dean Morton, Wei‐Shao Lin

    This technique describes a scanner‐agnostic digital workflow for generating dynamic mandibular motion from static virtual interocclusal records using a custom artificial intelligence (AI) algorithm and user interface. Virtual records of mandibular positions, including maximum intercuspation, protrusion, and lateral excursions, were captured with an intraoral scanner and processed through a custom interface developed using Python, an open‐source, script‐based programming language. The program interpolates intermediate positions using quantified point tracking and exports a motion path file compatible with dental computer‐aided design software. By leveraging AI and open‐source tools, this method offers a cost‐effective, non‐vendor‐specific solution for integrating individualized jaw motion into digital prosthodontic workflows.


  • Open Access

    Impact of operator experience on intraoral digital scanning: A systematic review, meta-analysis, and meta-regression. Report of the Committee on Research in Fixed Prosthodontics of the American Academy of Fixed Prosthodontics

    by Alvaro Limones, Dean Morton, Alessandro Sallorenzo, Wei-Shao Lin, Ramtin Sadid-Zadeh, Kamolphob Phasuk, Marta Revilla-León, Miguel Gómez-Polo


  • Open Access

    Interdisciplinary Management of Open Interproximal Embrasures

    by Yudai Ogawa, Otto Zuhr, Gustavo Avila‐Ortiz, Yukuhiro Kosaka, Tomohiro Ishikawa, Yi‐Wen Cathy Tsai, Dean Morton, Toshiki Nagai

    Objectives: To describe key etiological and risk factors associated with open interproximal embrasures (OIE) and propose a systematic interdisciplinary approach for their management, emphasizing the integration of periodontics, orthodontics, and prosthodontics. Overview: Optimal esthetics and function are priority outcomes in contemporary dentistry, often necessitating an interdisciplinary approach to achieve satisfactory results. OIE, commonly referred to as “black triangles,” result from the loss of interdental papillary height due to a variety of factors such as unfavorable bone crest‐to‐contact point distance, interproximal width, gingival thickness, tooth form, and axial root inclination. Their prevalence and clinical presentation may be influenced by age, history of orthodontic or periodontal treatment, and tooth morphology. Comprehensive diagnostic protocols and treatment strategies for the management of OIE may involve periodontal regeneration, soft tissue augmentation, orthodontic alignment, and restorative procedures, as demonstrated in this article. Conclusion: A structured, patient‐specific interdisciplinary approach emphasizing both “pink” (soft tissue) and “white” (tooth structure) esthetics is essential for effectively treating OIE, ultimately improving patient satisfaction and quality of life. Future clinical research should focus on evaluating the efficacy of various interdisciplinary treatment strategies. Clinical Significance: This article underscores the importance of interdisciplinary collaboration in managing OIE to optimize esthetics and function, ultimately enhancing patient satisfaction and quality of life.


  • Open Access

    Influence of prosthesis type and intraoral scanner‐based extraoral scanning protocol on the passive fit of CAD‐CAM verification devices

    by Toshiki Nagai, Yusuke Kuroda, Natalie Asavanant, Chao‐Chieh Yang, Dean Morton, Wei‐Shao Lin

    Purpose: To evaluate the impact of different complete‐arch digital scanning techniques and prosthesis types on the passive fit of computer‐aided design and computer‐aided manufacturing (CAD‐CAM) verification devices.Materials and Methods: Two different maxillary master casts with four multi‐unit abutment (MUA) implant analogs (FP‐1 and FP‐3 prosthesis types) were used as the basis for fabricating verification devices through two impression techniques (OptiSplint and RevEX). Group 1 utilized digital scans of splinted scanbodies reinforced with a light‐polymerizing acrylic resin and metal mesh on the FP‐1 cast (OptiSplint technique), Group 2 employed the same impression technique as Group 1 on the FP‐3 cast, Group 3 applied digital scans of reverse scanbodies connected to a passively fitting interim prosthesis on FP‐1 cast (RevEX technique), and Group 4 used the same impression technique as Group 3 on FP‐3 cast. A total of 40 milled verification devices were fabricated, with 10 devices allocated to each group. The misfit of verification devices was assessed using visual inspection, tactile sensation, and a one‐screw test, with any disagreements between the two primary examiners resolved by a third evaluator. Agreement between the clinicians was assessed using Cohen's kappa statistics and percent agreement. The percentage of misfits was calculated for each group and compared between groups using Fisher's exact tests (α = 0.05).Results: The misfit analysis showed the lowest misfit (10%) in Group 1 (OptiSplint‐FP1), followed by Groups 3 (RevEX‐FP1) and 4 (RevEX‐FP3) at 20%, and the highest (40%) in Group 2 (OptiSplint‐FP3), with no significant differences between groups by Fisher's exact tests (p > 0.05). Odds ratios indicated six times higher misfit odds for FP‐3 than FP‐1 with OptiSplint, no difference for FP‐1 versus FP‐3 with RevEX (odds ratio = 1.0), and lower odds with RevEX compared to OptiSplint under FP‐3 conditions (odds ratio = 0.375). Inter‐examiner agreement was strong, with 90% concordance and a Kappa statistic of 0.66, demonstrating substantial consistency.Conclusion: OptiSplint is preferable for FP1 cases, whereas RevEX suits FP3 cases when intraoral–scanner–based extraoral workflows are used. Despite these recommendations, misfits occurred in every group, suggesting that a verification cast may be prudent when adopting these newer scanning approaches. Clinicians should consider fabricating an additional verification cast with splinted scanbodies or a clinically satisfactory interim implant prosthesis. This cast can confirm implant positions whenever modern scanbodies such as OptiSplint or RevEX are incorporated into the workflow.


  • Open Access

    Peri‐implant tissue definition and registration with a 3D‐printed emergence profile former on titanium stock healing abutment: A dental technique and clinical report

    by Francisco X. Azpiazu‐Flores, Tisama Siyootagrai, Ahmed Elfana, Chao‐Chieh Yang, Dean Morton, Wei‐Shao Lin

    Recent focus has shifted toward refining the soft tissue emergence profile to enhance aesthetics, support peri‐implant health, and ensure long‐term success. Traditionally, titanium stock healing abutments or chairside‐customized abutments were used to shape peri‐implant tissues and develop the emergence profile for implant‐supported prostheses. However, advancements in digital dentistry now allow for more precise customization and increased treatment efficiency. This case report introduces a novel approach to shape the peri‐implant tissues using a 3D‐printed emergence profile former retained by a titanium stock healing abutment. The 3D‐printed emergence profile former reduced chairside time and simplified registering the gingival tissue contours and implant position with an intraoral scanner. Following removal, the peri‐implant soft tissues displayed enhanced volume buccally, creating an aesthetically pleasing restoration in a site with a notable horizontal tissue deficiency.