Thomas Lindow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Lindow has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
- Martin Ugander
Kolling Institute, Royal North Shore Hospital, and University of Sydney
11 shared publications Olle Pahlm
Clinical Physiology, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
11 shared publicationsLars Brudin
Department of Clinical Physiology, Kalmar county hospital, Kalmar, Sweden
8 shared publicationsMagnus Ekström
Department of Clinical Sciences in Lund, Respiratory Medicine, Allergology and Palliative Medicine, Lund University, Lund, Sweden
7 shared publicationsDaniel Manna
Department of Clinical Physiology, Department of Research and Development, Region Kronoberg, Växjö Central Hospital, Växjö, Sweden
6 shared publicationsKristofer Hedman
Department of Clinical Physiology in Linköping and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
6 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by Elsevier in JACEP Open
- Vol. 7 (5) , 100473
Improved Detection of Acute Coronary Occlusion Myocardial Infarction by an Artificial Intelligence Electrocardiogram Model in Swedish Emergency Departments
- 14 August 2026
- Published by Elsevier in JACEP Open
- Vol. 7 (5) , 100473
Open AccessImproved Detection of Acute Coronary Occlusion Myocardial Infarction by an Artificial Intelligence Electrocardiogram Model in Swedish Emergency Departments
- Open Access
- 17 June 2026
- Published by Elsevier in JACC: Advances
- Vol. 5 (6) , 102838
Integrating Resistant and Pulsatile Right Ventricular Load Improves Severity Assessment in Heart Failure Patients
- 17 June 2026
- Published by Elsevier in JACC: Advances
- Vol. 5 (6) , 102838
Open AccessIntegrating Resistant and Pulsatile Right Ventricular Load Improves Severity Assessment in Heart Failure Patients
- Open Access
- 1 January 2026
- Published by S. Karger AG in Pulse
- Vol. 14 (1) , 181-191
Blood Pressure Trajectories during Graded Exercise for the Prediction of Future Hypertension
Introduction: An exaggerated increase in systolic blood pressure (SBP) during exercise is associated with future hypertension. While previous studies evaluated peak SBP or two-point slopes, we aimed to identify SBP response patterns from the full SBP time-series during maximal incremental exercise and assess their value for predicting future hypertension diagnosis. Methods: In this cohort study, we analysed SBP recordings from 3,486 normotensive adults (mean age 50.6 years; 45% women) undergoing maximal cycle ergometry. Group-based trajectory modelling (GBTM) extracted sex-specific responses from the full SBP time-series. Associations with incident hypertension were evaluated using multivariable Cox analyses by sex and stratified by prehypertensive status (SBP 130–150 mm Hg or DBP 85–90 mm Hg). Results: In both sexes, GBTM identified three SBP response profiles, reflecting low, mid, and high responders. Over 7.9 years, 171 (8.8%) men and 169 (10.9%) women were diagnosed with hypertension. Incidence was markedly higher in high versus low responders (e.g., in women: 27.8 vs. 2.5 events per 1,000 follow-up years). The increased risk was independent of traditional risk factors, including resting SBP (hazard ratio relative to average risk (HRadj): 1.26 [95% confidence interval: 1.00–1.57] in men, 1.59 [1.22–2.07] in women). The association attenuated with increasing resting SBP in women (pinteraction = 0.003). Notably, high SBP response was independently associated with future hypertension diagnosis in those without prehypertension (e.g., in women, HRadj: 2.17 [1.49–3.17]), but not in those with prehypertension. Reclassification analyses indicated incremental predictive value beyond resting and peak SBP in women without prehypertension. Conclusions: Time-series analysis of exercise SBP revealed distinct response profiles predicting future hypertension diagnosis beyond resting blood pressure. Comprehensive interpretation of exercise SBP may improve risk stratification, particularly in women without prehypertension.
- 1 January 2026
- Published by S. Karger AG in Pulse
- Vol. 14 (1) , 181-191
Open AccessBlood Pressure Trajectories during Graded Exercise for the Prediction of Future Hypertension
Introduction: An exaggerated increase in systolic blood pressure (SBP) during exercise is associated with future hypertension. While previous studies evaluated peak SBP or two-point slopes, we aimed to identify SBP response patterns from the full SBP time-series during maximal incremental exercise and assess their value for predicting future hypertension diagnosis. Methods: In this cohort study, we analysed SBP recordings from 3,486 normotensive adults (mean age 50.6 years; 45% women) undergoing maximal cycle ergometry. Group-based trajectory modelling (GBTM) extracted sex-specific responses from the full SBP time-series. Associations with incident hypertension were evaluated using multivariable Cox analyses by sex and stratified by prehypertensive status (SBP 130–150 mm Hg or DBP 85–90 mm Hg). Results: In both sexes, GBTM identified three SBP response profiles, reflecting low, mid, and high responders. Over 7.9 years, 171 (8.8%) men and 169 (10.9%) women were diagnosed with hypertension. Incidence was markedly higher in high versus low responders (e.g., in women: 27.8 vs. 2.5 events per 1,000 follow-up years). The increased risk was independent of traditional risk factors, including resting SBP (hazard ratio relative to average risk (HRadj): 1.26 [95% confidence interval: 1.00–1.57] in men, 1.59 [1.22–2.07] in women). The association attenuated with increasing resting SBP in women (pinteraction = 0.003). Notably, high SBP response was independently associated with future hypertension diagnosis in those without prehypertension (e.g., in women, HRadj: 2.17 [1.49–3.17]), but not in those with prehypertension. Reclassification analyses indicated incremental predictive value beyond resting and peak SBP in women without prehypertension. Conclusions: Time-series analysis of exercise SBP revealed distinct response profiles predicting future hypertension diagnosis beyond resting blood pressure. Comprehensive interpretation of exercise SBP may improve risk stratification, particularly in women without prehypertension.
- Open Access
- 13 June 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 3 (2)
Echocardiography can accurately estimate pulmonary artery wedge pressure without left atrial volume information—diagnostic and prognostic performance
Aims: A quantitative estimate of pulmonary artery wedge pressure (PAWP) can be obtained using echocardiography, but including left atrial (LA) volume (ePAWP-LA) in the estimation may be misleading. We aimed to derive and validate a new estimate without LA volume information (ePAWP-NOLA) and compare its performance to the ASE/EACVI algorithms for diastolic dysfunction. Methods and results: ePAWP-NOLA was derived and validated in separate datasets of patients who had undergone right heart catheterization and echocardiography. The prognosis was assessed in the validation cohort and the National Echocardiography Database Australia (NEDA) using Cox regression adjusted for age, sex, and left ventricular ejection fraction (LVEF). In the derivation cohort (60 ± 15 years, 40% males, 31% with LVEF < 50%), ePAWP-NOLA was derived from mitral (E), and pulmonary vein systolic (S) and diastolic (D) Doppler velocities (n = 134, mean difference ± SD vs. PAWP: 0.0 ± 5.5 mmHg). In the validation cohort (n = 116, 51 ± 14 years, 69% males, 89% with LVEF < 50%), PAWP agreed with both ePAWP-NOLA and ePAWP-LA (difference 1.3 ± 6.1, 3.2 ± 6.3 mmHg, respectively). PAWP > 15 mmHg was accurately detected by both ePAWP-NOLA and ePAWP-LA [area under the curve: AUC (95%CI): 0.84 (0.76–0.92), 0.80 (0.72–0.88)]. AUC for the ASE/EACVI algorithm was lower [0.69 (0.61–0.77)]). ePAWP-NOLA and ePAWP-LA correlated with right ventricular afterload and were associated with death or implantation of left ventricular assist device, and with cardiovascular death in NEDA. Conclusion: ePAWP-NOLA has diagnostic and prognostic performance comparable to ePAWP-LA, and improved diagnostic performance compared to the ASE/EACVI diastolic dysfunction algorithm.
- 13 June 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 3 (2)
Open AccessEchocardiography can accurately estimate pulmonary artery wedge pressure without left atrial volume information—diagnostic and prognostic performance
Aims: A quantitative estimate of pulmonary artery wedge pressure (PAWP) can be obtained using echocardiography, but including left atrial (LA) volume (ePAWP-LA) in the estimation may be misleading. We aimed to derive and validate a new estimate without LA volume information (ePAWP-NOLA) and compare its performance to the ASE/EACVI algorithms for diastolic dysfunction. Methods and results: ePAWP-NOLA was derived and validated in separate datasets of patients who had undergone right heart catheterization and echocardiography. The prognosis was assessed in the validation cohort and the National Echocardiography Database Australia (NEDA) using Cox regression adjusted for age, sex, and left ventricular ejection fraction (LVEF). In the derivation cohort (60 ± 15 years, 40% males, 31% with LVEF < 50%), ePAWP-NOLA was derived from mitral (E), and pulmonary vein systolic (S) and diastolic (D) Doppler velocities (n = 134, mean difference ± SD vs. PAWP: 0.0 ± 5.5 mmHg). In the validation cohort (n = 116, 51 ± 14 years, 69% males, 89% with LVEF < 50%), PAWP agreed with both ePAWP-NOLA and ePAWP-LA (difference 1.3 ± 6.1, 3.2 ± 6.3 mmHg, respectively). PAWP > 15 mmHg was accurately detected by both ePAWP-NOLA and ePAWP-LA [area under the curve: AUC (95%CI): 0.84 (0.76–0.92), 0.80 (0.72–0.88)]. AUC for the ASE/EACVI algorithm was lower [0.69 (0.61–0.77)]). ePAWP-NOLA and ePAWP-LA correlated with right ventricular afterload and were associated with death or implantation of left ventricular assist device, and with cardiovascular death in NEDA. Conclusion: ePAWP-NOLA has diagnostic and prognostic performance comparable to ePAWP-LA, and improved diagnostic performance compared to the ASE/EACVI diastolic dysfunction algorithm.
- Open Access
- 9 May 2025
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 41 (7) , 1297-1308
Mitral annular plane systolic excursion to left atrial volume ratio – a strainless relation with left ventricular filling pressures
Left atrial reservoir strain (LASr) offers diagnostic and prognostic value in patients with heart failure. However, LASr may be technically challenging and is not available to all clinical echocardiographers. Since LASr is a consequence of left atrial (LA) stretch during apical descent of the mitral annulus, we hypothesized that a ratio between mitral annular plane systolic excursion (MAPSE) and LA volume (LAV) may offer similar diagnostic value as LASr. We aimed to investigate the relationship between MAPSE/LAV and LASr and evaluate the diagnostic performance of MAPSE/LAV to identify patients with elevated LV filling pressure. MAPSE/LAV and LA strain measures were obtained in patients referred for echocardiography due to aortic stenosis, and in patients who had undergone clinically indicated right heart catheterization (RHC) with simultaneous echocardiography. In 93 patients with moderate aortic stenosis, MAPSE/LAV was moderately correlated with LASr (r = 0.57) but was lower in patients with elevated compared to normal LV filling pressure by echocardiography (0.11 vs. 0.16 mm/mL, p < 0.001). In 72 patients who had undergone RHC and simultaneous echocardiography, MAPSE/LAV and LASr correlated weakly with pulmonary artery wedge pressure (PAWP) (r=-0.44 and r = 0.37). MAPSE/LAV was lower in patients with elevated (> 15 mmHg) vs. normal PAWP (0.14 mm/mL vs. 0.27 mm/mL). Accuracy for detection of elevated PAWP was similar for MAPSE/LAV (area under the curve MAPSE/LAV: 0.75 [0.58–0.92] and LASr: 0.75 [0.57–0.90]). Despite a moderate correlation with LASr, MAPSE/LAV provided similar diagnostic value as LASr in predicting elevated LV filling pressures as determined by echocardiography and RHC. Graphical Abstract
- 9 May 2025
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 41 (7) , 1297-1308
Open AccessMitral annular plane systolic excursion to left atrial volume ratio – a strainless relation with left ventricular filling pressures
Left atrial reservoir strain (LASr) offers diagnostic and prognostic value in patients with heart failure. However, LASr may be technically challenging and is not available to all clinical echocardiographers. Since LASr is a consequence of left atrial (LA) stretch during apical descent of the mitral annulus, we hypothesized that a ratio between mitral annular plane systolic excursion (MAPSE) and LA volume (LAV) may offer similar diagnostic value as LASr. We aimed to investigate the relationship between MAPSE/LAV and LASr and evaluate the diagnostic performance of MAPSE/LAV to identify patients with elevated LV filling pressure. MAPSE/LAV and LA strain measures were obtained in patients referred for echocardiography due to aortic stenosis, and in patients who had undergone clinically indicated right heart catheterization (RHC) with simultaneous echocardiography. In 93 patients with moderate aortic stenosis, MAPSE/LAV was moderately correlated with LASr (r = 0.57) but was lower in patients with elevated compared to normal LV filling pressure by echocardiography (0.11 vs. 0.16 mm/mL, p < 0.001). In 72 patients who had undergone RHC and simultaneous echocardiography, MAPSE/LAV and LASr correlated weakly with pulmonary artery wedge pressure (PAWP) (r=-0.44 and r = 0.37). MAPSE/LAV was lower in patients with elevated (> 15 mmHg) vs. normal PAWP (0.14 mm/mL vs. 0.27 mm/mL). Accuracy for detection of elevated PAWP was similar for MAPSE/LAV (area under the curve MAPSE/LAV: 0.75 [0.58–0.92] and LASr: 0.75 [0.57–0.90]). Despite a moderate correlation with LASr, MAPSE/LAV provided similar diagnostic value as LASr in predicting elevated LV filling pressures as determined by echocardiography and RHC. Graphical Abstract
- Open Access
Study protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease
Background: It is now possible to acquire a fully diagnostic standard 12-lead electrocardiography (ECG) using a smartwatch, a smartphone app, and no additional hardware. This study aims to evaluate the predictive performance of advanced ECG (A-ECG) analysis applied to a smartwatch 12-lead ECG (SWECG) acquired using an Apple Watch in identifying cardiovascular risks among asymptomatic adults performing consumer self-screening in the general population. Methods and Design: The Heart Watch Study is a prospective, Australia-wide observational cohort study. The study will recruit 30,000 participants aged 20-79 years without prior known cardiovascular disease. Participants will enrol and consent electronically, and download a dedicated study iPhone app that enables a directed 12-lead SWECG acquisition using an Apple Watch. The recordings will undergo both conventional and A-ECG analysis. Follow-up will be performed through linkage with administrative health datasets in Australia, including hospital visits and mortality. The primary combined endpoint is all-cause mortality, hospitalization for cardiovascular causes, and incident cardiovascular disease (arrythmia, ischemic heart disease, heart failure) as predicted by existing A-ECG analyses. Conclusion: This study evaluates the feasibility of performing a fully diagnostic standard 12-lead SWECG using only a smartwatch and a smartphone application, and addresses the prognostic value of A-ECG machine-learning based analysis in consumer self-screening in a large, diverse and apparently healthy population.
Open AccessStudy protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease
Background: It is now possible to acquire a fully diagnostic standard 12-lead electrocardiography (ECG) using a smartwatch, a smartphone app, and no additional hardware. This study aims to evaluate the predictive performance of advanced ECG (A-ECG) analysis applied to a smartwatch 12-lead ECG (SWECG) acquired using an Apple Watch in identifying cardiovascular risks among asymptomatic adults performing consumer self-screening in the general population. Methods and Design: The Heart Watch Study is a prospective, Australia-wide observational cohort study. The study will recruit 30,000 participants aged 20-79 years without prior known cardiovascular disease. Participants will enrol and consent electronically, and download a dedicated study iPhone app that enables a directed 12-lead SWECG acquisition using an Apple Watch. The recordings will undergo both conventional and A-ECG analysis. Follow-up will be performed through linkage with administrative health datasets in Australia, including hospital visits and mortality. The primary combined endpoint is all-cause mortality, hospitalization for cardiovascular causes, and incident cardiovascular disease (arrythmia, ischemic heart disease, heart failure) as predicted by existing A-ECG analyses. Conclusion: This study evaluates the feasibility of performing a fully diagnostic standard 12-lead SWECG using only a smartwatch and a smartphone application, and addresses the prognostic value of A-ECG machine-learning based analysis in consumer self-screening in a large, diverse and apparently healthy population.
- Open Access
Echocardiography can accurately estimate pulmonary artery wedge pressure without left atrial volume information – diagnostic and prognostic performance
Background A quantitative estimate of pulmonary artery wedge pressures (PAWP) can be obtained using echocardiography, but including left atrial (LA) volume (ePAWP-LA) in the estimation may be misleading. We aimed to derive and validate a new estimate without LA volume information (ePAWP-NOLA) and compare its performance to the ASE/EACVI algorithms for diastolic dysfunction. Methods ePAWP-NOLA was derived and validated in separate datasets of patients who had undergone right heart catheterization and echocardiography. Prognosis was assessed in the validation cohort and the National Echocardiography Database Australia (NEDA) using Cox regression adjusted for age, sex and left ventricular ejection fraction (LVEF). Results In the derivation cohort (60±15 years, 40% males, 31% with LVEFConclusions ePAWP-NOLA has diagnostic and prognostic performance comparable to ePAWP-LA, and improved diagnostic performance compared to the ASE/EACVI diastolic dysfunction algorithm.
Open AccessEchocardiography can accurately estimate pulmonary artery wedge pressure without left atrial volume information – diagnostic and prognostic performance
Background A quantitative estimate of pulmonary artery wedge pressures (PAWP) can be obtained using echocardiography, but including left atrial (LA) volume (ePAWP-LA) in the estimation may be misleading. We aimed to derive and validate a new estimate without LA volume information (ePAWP-NOLA) and compare its performance to the ASE/EACVI algorithms for diastolic dysfunction. Methods ePAWP-NOLA was derived and validated in separate datasets of patients who had undergone right heart catheterization and echocardiography. Prognosis was assessed in the validation cohort and the National Echocardiography Database Australia (NEDA) using Cox regression adjusted for age, sex and left ventricular ejection fraction (LVEF). Results In the derivation cohort (60±15 years, 40% males, 31% with LVEFConclusions ePAWP-NOLA has diagnostic and prognostic performance comparable to ePAWP-LA, and improved diagnostic performance compared to the ASE/EACVI diastolic dysfunction algorithm.
- Open Access
- 18 December 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (12) , e0302111
Abnormally high exertional breathlessness predicts mortality in people referred for incremental cycle exercise testing
Background: Exertional breathlessness is a key symptom in cardiorespiratory disease and can be quantified using incremental exercise testing, but its prognostic significance is unknown. We evaluated the ability of abnormally high breathlessness intensity during incremental cycle exercise testing to predict all-cause, respiratory, and cardiac mortality. Study design and methods: Longitudinal cohort study of adults referred for exercise testing followed prospectively for mortality assessed using the Swedish National Causes of Death Registry. Abnormally high exertional breathlessness was defined as a breathlessness intensity response (Borg 0–10 scale) > the upper limit of normal using published reference equations. Mortality was analyzed using multivariable Cox regression, unadjusted and adjusted for age, sex, and body mass index. A further mortality analysis was also done adjusted for select common comorbidities in addition to age, sex and body mass index. Results: Of the 13,506 people included (46% female, age 59±15 years), 2,867 (21%) had abnormally high breathlessness during exercise testing. Over a median follow up of 8.0 years, 1,687 (12%) people died. No participant was lost to follow-up. Compared to those within normal predicted ranges, people with abnormally high exertional breathlessness had higher mortality from all causes (adjusted hazard ratio [aHR] 2.3, [95% confidence interval] 2.1–2.6), respiratory causes (aHR 5.2 [3.4–8.0]) and cardiac causes (aHR 3.0 [2.5–3.6]). Even among people with normal exercise capacity (defined as peak Watt ≥75% of predicted exercise capacity, n = 10,284) those with abnormally high exertional breathlessness were at greater risk of all-cause mortality than people with exertional breathlessness within the normal predicted range (aHR 1.5 [1.2–1.8]). Conclusion: Among people referred for exercise testing, abnormally high exertional breathlessness, quantified using healthy reference values, independently predicted all-cause, respiratory and cardiac mortality.
- 18 December 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (12) , e0302111
Open AccessAbnormally high exertional breathlessness predicts mortality in people referred for incremental cycle exercise testing
Background: Exertional breathlessness is a key symptom in cardiorespiratory disease and can be quantified using incremental exercise testing, but its prognostic significance is unknown. We evaluated the ability of abnormally high breathlessness intensity during incremental cycle exercise testing to predict all-cause, respiratory, and cardiac mortality. Study design and methods: Longitudinal cohort study of adults referred for exercise testing followed prospectively for mortality assessed using the Swedish National Causes of Death Registry. Abnormally high exertional breathlessness was defined as a breathlessness intensity response (Borg 0–10 scale) > the upper limit of normal using published reference equations. Mortality was analyzed using multivariable Cox regression, unadjusted and adjusted for age, sex, and body mass index. A further mortality analysis was also done adjusted for select common comorbidities in addition to age, sex and body mass index. Results: Of the 13,506 people included (46% female, age 59±15 years), 2,867 (21%) had abnormally high breathlessness during exercise testing. Over a median follow up of 8.0 years, 1,687 (12%) people died. No participant was lost to follow-up. Compared to those within normal predicted ranges, people with abnormally high exertional breathlessness had higher mortality from all causes (adjusted hazard ratio [aHR] 2.3, [95% confidence interval] 2.1–2.6), respiratory causes (aHR 5.2 [3.4–8.0]) and cardiac causes (aHR 3.0 [2.5–3.6]). Even among people with normal exercise capacity (defined as peak Watt ≥75% of predicted exercise capacity, n = 10,284) those with abnormally high exertional breathlessness were at greater risk of all-cause mortality than people with exertional breathlessness within the normal predicted range (aHR 1.5 [1.2–1.8]). Conclusion: Among people referred for exercise testing, abnormally high exertional breathlessness, quantified using healthy reference values, independently predicted all-cause, respiratory and cardiac mortality.
- Open Access
- 14 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (24) , 7629
Utility of Simultaneous Left Atrial Strain–Volume Relationship During Passive Leg Lift to Identify Elevated Left Ventricular Filling Pressure—A Proof-of-Concept Study
Background: The assessment of left ventricular (LV) filling pressure in heart failure (HF) poses a diagnostic challenge, as HF patients may have normal LV filling pressures at rest but often display elevated LV filling pressures during exercise. Rapid preload increase during passive leg lift (PLL) may unmask HF in such challenging scenarios. We explored the dynamic interplay between simultaneous left atrial (LA) function and volume using LA strain/volume loops during rest and PLL and compared its diagnostic performance with conventional echocardiographic surrogates to detect elevated LV filling pressure. Methods: We retrospectively reviewed 35 patients with clinical HF who underwent simultaneous echocardiography and right heart catheterization before and immediately after PLL. Patients with atrial fibrillation (n = 4) were excluded. Twenty age-matched, healthy controls were added as controls. LA reservoir strain (LASr) was analyzed using speckle-tracking echocardiography. LA strain–volume loops were generated, including the best-fit linear regression line employing simultaneous LASr and LA volume. Results: LA strain–volume slope was lower for HF patients when compared with controls (0.71 vs. 1.22%/mL, p < 0.001). During PLL, the LA strain–volume slope displayed a moderately strong negative correlation with invasive pulmonary arterial wedge pressure (PAWP) (r = −0.71, p < 0.001). At a 0.74%/mL cut-off, the LA strain–volume slope displayed 88% sensitivity and 86% specificity to identify elevated PAWP (AUC 0.89 [0.76–1.00]). In comparison, LASr demonstrated strong but numerically lower diagnostic performance (AUC 0.82 [0.67–0.98]), and mitral E/e’ showed poor performance (AUC 0.57 [0.32–0.82]). Conclusions: In this proof-of-concept study, LA strain–volume characteristics provide incremental diagnostic value over conventional echocardiographic measures in the identification of elevated LV filling pressure.
- 14 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (24) , 7629
Open AccessUtility of Simultaneous Left Atrial Strain–Volume Relationship During Passive Leg Lift to Identify Elevated Left Ventricular Filling Pressure—A Proof-of-Concept Study
Background: The assessment of left ventricular (LV) filling pressure in heart failure (HF) poses a diagnostic challenge, as HF patients may have normal LV filling pressures at rest but often display elevated LV filling pressures during exercise. Rapid preload increase during passive leg lift (PLL) may unmask HF in such challenging scenarios. We explored the dynamic interplay between simultaneous left atrial (LA) function and volume using LA strain/volume loops during rest and PLL and compared its diagnostic performance with conventional echocardiographic surrogates to detect elevated LV filling pressure. Methods: We retrospectively reviewed 35 patients with clinical HF who underwent simultaneous echocardiography and right heart catheterization before and immediately after PLL. Patients with atrial fibrillation (n = 4) were excluded. Twenty age-matched, healthy controls were added as controls. LA reservoir strain (LASr) was analyzed using speckle-tracking echocardiography. LA strain–volume loops were generated, including the best-fit linear regression line employing simultaneous LASr and LA volume. Results: LA strain–volume slope was lower for HF patients when compared with controls (0.71 vs. 1.22%/mL, p < 0.001). During PLL, the LA strain–volume slope displayed a moderately strong negative correlation with invasive pulmonary arterial wedge pressure (PAWP) (r = −0.71, p < 0.001). At a 0.74%/mL cut-off, the LA strain–volume slope displayed 88% sensitivity and 86% specificity to identify elevated PAWP (AUC 0.89 [0.76–1.00]). In comparison, LASr demonstrated strong but numerically lower diagnostic performance (AUC 0.82 [0.67–0.98]), and mitral E/e’ showed poor performance (AUC 0.57 [0.32–0.82]). Conclusions: In this proof-of-concept study, LA strain–volume characteristics provide incremental diagnostic value over conventional echocardiographic measures in the identification of elevated LV filling pressure.
- Open Access
- 9 October 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (1) , 45-54
Advanced electrocardiography heart age: a prognostic, explainable machine learning approach applicable to sinus and non-sinus rhythms
An explainable advanced electrocardiography (A-ECG) Heart Age gap is the difference between A-ECG Heart Age and chronological age. This gap is an estimate of accelerated cardiovascular ageing expressed in years of healthy human aging, and can intuitively communicate cardiovascular risk to the general population. However, existing A-ECG Heart Age requires sinus rhythm. To develop and prognostically validate a revised, explainable A-ECG Heart Age applicable to both sinus and non-sinus rhythms. An A-ECG Heart Age excluding P-wave measures was derived from the 10-second 12-lead ECG in a derivation cohort using multivariable regression machine learning with Bayesian 5-minute 12-lead A-ECG Heart Age as reference. The Heart Age was externally validated in a separate cohort of patients referred for cardiovascular magnetic resonance imaging by describing its association with heart failure hospitalization or death using Cox regression, and its association with comorbidities. In the derivation cohort (n=2771), A-ECG Heart Age agreed with the 5-min Heart Age (R2=0.91, bias 0.0±6.7 years), and increased with increasing co-morbidity. In the validation cohort (n=731, mean age 54±15 years, 43% female, n=139 events over 5.7 [4.8–6.7] years follow-up), increased A-ECG Heart Age gap (≥10 years) associated with events (hazard ratio [95% confidence interval] 2.04 [1.38–3.00], C-statistic 0.58 [0.54–0.62], and the presence of hypertension, diabetes mellitus, hypercholesterolemia, and heart failure (p≤0.009 for all). An explainable A-ECG Heart Age gap applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival.
- 9 October 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (1) , 45-54
Open AccessAdvanced electrocardiography heart age: a prognostic, explainable machine learning approach applicable to sinus and non-sinus rhythms
An explainable advanced electrocardiography (A-ECG) Heart Age gap is the difference between A-ECG Heart Age and chronological age. This gap is an estimate of accelerated cardiovascular ageing expressed in years of healthy human aging, and can intuitively communicate cardiovascular risk to the general population. However, existing A-ECG Heart Age requires sinus rhythm. To develop and prognostically validate a revised, explainable A-ECG Heart Age applicable to both sinus and non-sinus rhythms. An A-ECG Heart Age excluding P-wave measures was derived from the 10-second 12-lead ECG in a derivation cohort using multivariable regression machine learning with Bayesian 5-minute 12-lead A-ECG Heart Age as reference. The Heart Age was externally validated in a separate cohort of patients referred for cardiovascular magnetic resonance imaging by describing its association with heart failure hospitalization or death using Cox regression, and its association with comorbidities. In the derivation cohort (n=2771), A-ECG Heart Age agreed with the 5-min Heart Age (R2=0.91, bias 0.0±6.7 years), and increased with increasing co-morbidity. In the validation cohort (n=731, mean age 54±15 years, 43% female, n=139 events over 5.7 [4.8–6.7] years follow-up), increased A-ECG Heart Age gap (≥10 years) associated with events (hazard ratio [95% confidence interval] 2.04 [1.38–3.00], C-statistic 0.58 [0.54–0.62], and the presence of hypertension, diabetes mellitus, hypercholesterolemia, and heart failure (p≤0.009 for all). An explainable A-ECG Heart Age gap applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival.