Ari Kauppinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ari Kauppinen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Jarkko Ketolainen
School of Pharmacy, University of Eastern Finland, Yliopistonranta 1 C, 70211 Kuopio, Finland
4 shared publicationsKristiina Järvinen
School of Pharmacy, Promis Centre, Faculty of Health Sciences, University of Eastern Finland, P.O. Box 1627, Kuopio FI-70211, Finland
4 shared publicationsMaunu Toiviainen
Optical Measurement Technologies, VTT Technical Research Centre of Finland, Kuopio, FI 70211, Finland
3 shared publicationsMikko Juuti
Optical Measurement Technologies, VTT Technical Research Centre of Finland, Kuopio, FI 70211, Finland
3 shared publicationsJanne Paaso
Optical Measurement Technologies, VTT Technical Research Centre of Finland, P.O. Box 1100, Oulu FI-90571, Finland
2 shared publicationsOssi Korhonen
School of Pharmacy, Faculty of Health Sciences, University of Eastern Finland, Kuopio, Finland
2 shared publications
Latest Publications
- 1 October 2019
- Published by Elsevier in Powder Technology
- Vol. 355, 67-71
Dead mass in continuous blending
- 1 October 2019
- Published by Elsevier in Powder Technology
- Vol. 355, 67-71
Dead mass in continuous blending
- Open Access
- 1 February 2018
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 123, 50-58
Efficient production of solid dispersions by spray drying solutions of high solid content using a 3-fluid nozzle
- 1 February 2018
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 123, 50-58
Open AccessEfficient production of solid dispersions by spray drying solutions of high solid content using a 3-fluid nozzle
- 1 September 2014
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 103 (9) , 2839-2846
Near‐Infrared Imaging for High‐Throughput Screening of Moisture Induced Changes in Freeze‐Dried Formulations
- 1 September 2014
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 103 (9) , 2839-2846
Near‐Infrared Imaging for High‐Throughput Screening of Moisture Induced Changes in Freeze‐Dried Formulations
- 1 July 2014
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 95, 229-237
Validation of a multipoint near-infrared spectroscopy method for in-line moisture content analysis during freeze-drying
- 1 July 2014
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 95, 229-237
Validation of a multipoint near-infrared spectroscopy method for in-line moisture content analysis during freeze-drying
- 10 November 2013
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 66 (3) , 367-377
Effect of storage on the dissolution rate of a fast-dissolving perphenazine/β-cyclodextrin complex
Objective: In general, the chemical and physical stability of amorphous cyclodextrin complexes and how storage affects their dissolution rate have not been widely reported. The aim of this study was to evaluate the solid-state stability of a fast-dissolving perphenazine/β-cyclodextrin (β-CD) complex, which has been found to be well absorbed after sublingual administration to rabbits. In addition, the dissolution rate of plain β-CD in crystalline and amorphous forms was determined. Methods: The amorphous perphenazine/β-CD complex powders were prepared by spray-drying and freeze-drying, and their stability was examined after storage at 40°C, 75% relative humidity (RH) or at room temperature, 60% RH for up to 82 days. Key findings: Perphenazine was found to be chemically stable in all samples. The dissolution rate of perphenazine remained practically unchanged at both storage conditions, although partial crystallization was observed in both spray-dried and freeze-dried samples at 40°C, 75% RH. Interestingly, it was also observed that the dissolution rates of crystalline and amorphous β-CD were similar. Conclusion: The results suggest that CD complexation may represent a suitable alternative for preparing intraorally dissolving formulations because the fast dissolution rate of the drug was maintained even though changes in the crystal structure were observed during storage.
- 10 November 2013
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 66 (3) , 367-377
Effect of storage on the dissolution rate of a fast-dissolving perphenazine/β-cyclodextrin complex
Objective: In general, the chemical and physical stability of amorphous cyclodextrin complexes and how storage affects their dissolution rate have not been widely reported. The aim of this study was to evaluate the solid-state stability of a fast-dissolving perphenazine/β-cyclodextrin (β-CD) complex, which has been found to be well absorbed after sublingual administration to rabbits. In addition, the dissolution rate of plain β-CD in crystalline and amorphous forms was determined. Methods: The amorphous perphenazine/β-CD complex powders were prepared by spray-drying and freeze-drying, and their stability was examined after storage at 40°C, 75% relative humidity (RH) or at room temperature, 60% RH for up to 82 days. Key findings: Perphenazine was found to be chemically stable in all samples. The dissolution rate of perphenazine remained practically unchanged at both storage conditions, although partial crystallization was observed in both spray-dried and freeze-dried samples at 40°C, 75% RH. Interestingly, it was also observed that the dissolution rates of crystalline and amorphous β-CD were similar. Conclusion: The results suggest that CD complexation may represent a suitable alternative for preparing intraorally dissolving formulations because the fast dissolution rate of the drug was maintained even though changes in the crystal structure were observed during storage.
- 28 January 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (4) , 2377-2384
In-Line Multipoint Near-Infrared Spectroscopy for Moisture Content Quantification during Freeze-Drying
During the past decade, near-infrared (NIR) spectroscopy has been applied for in-line moisture content quantification during a freeze-drying process. However, NIR has been used as a single-vial technique and thus is not representative of the entire batch. This has been considered as one of the main barriers for NIR spectroscopy becoming widely used in process analytical technology (PAT) for freeze-drying. Clearly it would be essential to monitor samples that reliably represent the whole batch. The present study evaluated multipoint NIR spectroscopy for in-line moisture content quantification during a freeze-drying process. Aqueous sucrose solutions were used as model formulations. NIR data was calibrated to predict the moisture content using partial least-squares (PLS) regression with Karl Fischer titration being used as a reference method. PLS calibrations resulted in root-mean-square error of prediction (RMSEP) values lower than 0.13%. Three noncontact, diffuse reflectance NIR probe heads were positioned on the freeze-dryer shelf to measure the moisture content in a noninvasive manner, through the side of the glass vials. The results showed that the detection of unequal sublimation rates within a freeze-dryer shelf was possible with the multipoint NIR system in use. Furthermore, in-line moisture content quantification was reliable especially toward the end of the process. These findings indicate that the use of multipoint NIR spectroscopy can achieve representative quantification of moisture content and hence a drying end point determination to a desired residual moisture level.
- 28 January 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (4) , 2377-2384
In-Line Multipoint Near-Infrared Spectroscopy for Moisture Content Quantification during Freeze-Drying
During the past decade, near-infrared (NIR) spectroscopy has been applied for in-line moisture content quantification during a freeze-drying process. However, NIR has been used as a single-vial technique and thus is not representative of the entire batch. This has been considered as one of the main barriers for NIR spectroscopy becoming widely used in process analytical technology (PAT) for freeze-drying. Clearly it would be essential to monitor samples that reliably represent the whole batch. The present study evaluated multipoint NIR spectroscopy for in-line moisture content quantification during a freeze-drying process. Aqueous sucrose solutions were used as model formulations. NIR data was calibrated to predict the moisture content using partial least-squares (PLS) regression with Karl Fischer titration being used as a reference method. PLS calibrations resulted in root-mean-square error of prediction (RMSEP) values lower than 0.13%. Three noncontact, diffuse reflectance NIR probe heads were positioned on the freeze-dryer shelf to measure the moisture content in a noninvasive manner, through the side of the glass vials. The results showed that the detection of unequal sublimation rates within a freeze-dryer shelf was possible with the multipoint NIR system in use. Furthermore, in-line moisture content quantification was reliable especially toward the end of the process. These findings indicate that the use of multipoint NIR spectroscopy can achieve representative quantification of moisture content and hence a drying end point determination to a desired residual moisture level.
- 15 January 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (4) , 2109-2116
Microscale Freeze-Drying with Raman Spectroscopy as a Tool for Process Development
Until recently, the freeze-drying process and formulation development have suffered from a lack of microscale analytical tools. Using such an analytical tool should decrease the required sample volume and also shorten the duration of the experiment compared to a laboratory scale setup. This study evaluated the applicability of Raman spectroscopy for in-line monitoring of a microscale freeze-drying process. The effect of cooling rate and annealing step on the solid-state formation of mannitol was studied. Raman spectra were subjected to principal component analysis to gain a qualitative understanding of the process behavior. In addition, mannitol solid-state form ratios were semiquantitatively analyzed during the process with a classical least-squares regression. A standard cooling rate of 1 °C/min with or without an annealing step at −10 °C resulted in a mixture of α, β, δ, and amorphous forms of mannitol. However, a standard cooling rate induced the formation of mannitol hemihydrate, and a secondary drying temperature of +60 °C was required to transform the hemihydrate form to the more stable anhydrous polymorphs. A fast cooling rate of 10 °C/min mainly produced δ and amorphous forms of mannitol, regardless of annealing. These results are consistent with those from larger scale equipment. In-line monitoring the solid-state form of a sample is feasible with a Raman spectrometer coupled microscale freeze-drying stage. These results demonstrate the utility of a rapid, in-line, low sample volume method for the semiquantitative analysis of the process and formulation development of freeze-dried products on the microscale.
- 15 January 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (4) , 2109-2116
Microscale Freeze-Drying with Raman Spectroscopy as a Tool for Process Development
Until recently, the freeze-drying process and formulation development have suffered from a lack of microscale analytical tools. Using such an analytical tool should decrease the required sample volume and also shorten the duration of the experiment compared to a laboratory scale setup. This study evaluated the applicability of Raman spectroscopy for in-line monitoring of a microscale freeze-drying process. The effect of cooling rate and annealing step on the solid-state formation of mannitol was studied. Raman spectra were subjected to principal component analysis to gain a qualitative understanding of the process behavior. In addition, mannitol solid-state form ratios were semiquantitatively analyzed during the process with a classical least-squares regression. A standard cooling rate of 1 °C/min with or without an annealing step at −10 °C resulted in a mixture of α, β, δ, and amorphous forms of mannitol. However, a standard cooling rate induced the formation of mannitol hemihydrate, and a secondary drying temperature of +60 °C was required to transform the hemihydrate form to the more stable anhydrous polymorphs. A fast cooling rate of 10 °C/min mainly produced δ and amorphous forms of mannitol, regardless of annealing. These results are consistent with those from larger scale equipment. In-line monitoring the solid-state form of a sample is feasible with a Raman spectrometer coupled microscale freeze-drying stage. These results demonstrate the utility of a rapid, in-line, low sample volume method for the semiquantitative analysis of the process and formulation development of freeze-dried products on the microscale.