MEMichael Esser

Michael Esser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Esser has a total of 103 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Coronal shear fractures of the distal humerus in children and adolescents: proposal for a modified classification

    by Justus Lieber, Michael Esser, Francisco F Fernandez, Peter P Schmittenbecher, Dorien Schneidmueller, Peter Strohm, Martin M Kaiser, Ralf Kraus

    Purpose: Coronal shear fractures (CSF) of the capitulum and trochlea humeri are rare injuries during growth age. No systematic, prospective analysis of the classification, procedure, and outcome has yet been found in the literature. Materials and methods: Based on the results of a multicentre study of CSF in growing patients, we propose a redesign of the AO Paediatric Comprehensive Classification of Long-Bone Fractures (PCCF) for children and adolescents. We also assessed inter-rater agreement consistency with the modified classification and calculated the intra-class correlation coefficient (ICC) and its 95% confident interval (CI). Results: A detailed classification has been proposed that refers to the location of the fragment, the extent to which the trochlea is involved, and the distinction between single and multiple fracture injuries. This modified AO classification distinguishes between five types of injury (13-E/3.1I – 13-E/3.1IV and 13-E/3.2), replacing the current code 13r-E/8.1. Inter-rater reliability using this modified classification was moderate (ICC 0.452 (95% CI 0,284; 0,661). This is more accurate than all previous classifications tested for CSF. Conclusion: A revised classification of coronal shear fractures of the distal humerus in children and adolescents is required. Our proposed classification considers the various types of this injury and their implications for treatment. Cross-sectional imaging is necessary for any classification to be applied successfully, since plain radiographs do not provide sufficiently precise information.

  • Open Access

    Conservative management of 900 pediatric distal radius fractures using the schede cast: a multicenter study

    by Simon Scherer, Jurek Schultz, Till Rausch, Benjamin Schoof, Laura Altmeier, Josephine Hertel, Meltem Sahin, Michael Esser, Boy Bohn, Guido Fitze, et al.

    Background: Distal forearm fractures are among the most common pediatric injuries and are typically managed with cast immobilization. Volar-flexion ulnar-deviation splints (Schede casts) have been proposed to reduce displacement and prevent secondary dislocation. However, data on efficacy and safety in children remain limited. This study aimed to evaluate the clinical outcomes of Schede cast immobilization across four pediatric trauma centres over a 16-year period. Methods: We conducted a retrospective analysis of patients under 18 years with distal forearm fractures treated with Schede casts. Demographic data, fracture characteristics, initial and post-cast displacement, incidence of secondary dislocation, and complications were recorded and analyzed. Results: A total of 900 patients (mean age 9.47 years) were included. The most common mechanism of injury was sports-related trauma, and transverse metaphyseal fractures predominated. Mean initial displacement was 17.7° (± 9.4°), reduced to 5.9° (± 5.5°) after cast application and 6.9° (± 5.4°) at consolidation after a mean of 35 (± 16) days. Secondary dislocations were effectively prevented at flexion angles > 50° ( p < 0.001). Complications were rare: tingling paresthesia occurred in 22 patients (2.4%), and prolonged movement restriction in 8 patients (0.9%). All adverse events resolved within days to weeks without long-term sequelae. Conclusion: Schede cast immobilization is a simple, safe, and effective method for retaining distal radius fractures in children. It reliably prevents secondary dislocation while maintaining low complication rates, supporting its continued use in pediatric trauma care.

  • Open Access

    Fluoroscopically guided jejunal tube placement via percutaneous gastrostomy in children: technical success, safety, and procedural parameters

    by Michael Esser, Jakob Spogis, Johannes Hilberath, Jürgen F. Schäfer, Ilias Tsiflikas

    Background: Fluoroscopically guided jejunal tube placement via percutaneous endoscopic gastrostomy (PEG-J) provides minimally invasive post-pyloric access in children. Limited data exist regarding routine application and procedural risks. Objective: To evaluate the safety and technical success of PEG-J in pediatric patients, performed without general anesthesia or sedation. Materials and methods: All pediatric cases of fluoroscopically guided PEG-J procedures performed between 2011 and 2025 were included. Fluoroscopic images were reviewed to determine the final position of the tube tip. Technical success, complications, anatomical variants, and tube patency were assessed. Fluoroscopy time and dose area product (DAP) were documented. Results: A total of 126 PEG-J procedures in 60 children (36 males) were analyzed. The technical success rate was 85% (107/126) with final tube tip placement in the jejunum in 88 cases (82%) and in the duodenum in 19 cases (18%). Nineteen procedures (15%) were unsuccessful, including six with documented anatomical causes (steep vertical duodenal entry, n =2; malrotation, hiatus hernia, hooked stomach in superior mesenteric artery syndrome, steep take-off of the jejunum with kinking of the tube at the ligament of Treitz, n =1 each) and 13 without documented reasons. The median fluoroscopy time was 5 min 24 s (range, 2 s–37 min), at a frame rate of 0.5 frames per second. The median DAP was 6.1 cGy·cm 2 (range, 0.08–343 cGy·cm 2 ). Conclusion: Fluoroscopically guided PEG-J placement is a safe and effective procedure in pediatric patients, with high technical success and low radiation exposure. Graphical


  • Prospective evaluation of recommendations for nasal insertion depths in neonatal intubation: a prospective quality assurance study

    by Christian A Maiwald, Nina Ott, Frank Fideler, Anna C Jock, Michael Esser, Bianca Haase, Axel R Franz, Christian F Poets, Laila Springer

    Objective Recommendations on nasal intubation depths in term or preterm newborns are scarce, although this is the preferred route in some countries. Postmenstrual age (PMA) and weight-based recommendations were recently published by our group. Design A prospective quality assurance study Setting Single-centre study (University Children’s Hospital Tübingen) Patients All nasally intubated term and preterm infants between August 2021 and August 2023 Interventions Physicians were free to choose the method of orientation for the insertion depth (our recommendations vs other’s (eg, endotracheal tube (ETT) tip markers)). Subsequently, chest X-rays were performed. Correct ETT placement was defined as the tip visible between thoracic vertebrae 1–3. X-ray investigators were blinded to the method of orientation. Main outcome measures Main outcome was the rate of correct ETT placements using our previous recommendation compared with other orientations. Secondary, a subgroup analysis for infants Results 114 intubations/infants were analysed (39 weight-based; 26 PMA-based; 49 others). Median PMA (IQR) was 30 0/7 weeks (26 6/7–35 0/7), weight 1310 g (793–2300). Correct ETT placement was in 74% following our recommendations versus 55% in others (p=0.046). No difference was seen between PMA-based and weight-based recommendations (77 vs 69%; p=0.57). 48 infants Conclusions Our previously published recommendations for nasal intubation depths are applicable in routine care leading to a more accurate ETT placement than with other orientations.


  • Open Access

    Semiautomatic three-dimensional ultrasound renal volume segmentation in pediatric hydronephrosis: interrater agreement and correlation to conventional hydronephrosis grading

    by Michael Esser, Ilias Tsiflikas, James R. Jago, Laurence Rouet, Alexander Stebner, Jürgen F. Schäfer

    Background: Two-dimensional (D) assessment of renal volume underestimates the actual value and shows high interobserver variability. Limited data exist on innovative 3-D ultrasound (US) technique for the evaluation of pediatric hydronephrosis. Objective: To assess the interrater agreement of kidney volume segmentation by 3-D US with a matrix array transducer in children with hydronephrosis and to compare the 3-D metrics to conventional hydronephrosis grading. Materials and methods: We prospectively acquired 48 renal volumes in 45 patients with hydronephrosis by freehand 3-D US (6–1 MHz volumetric sector array, electronic rotation; median age, 4 years; 1 month to 16 years). Semi-automated kidney segmentation was performed by two independent readers providing volumes for total kidney (renal capsule), dilated collective system, renal parenchyma (renal capsule-collective system) and hydronephrosis index (renal parenchyma/capsule). Interrater agreement was evaluated with Bland–Altman plots, intraclass correlation coefficient (ICC) and Dice similarity coefficients. The maximum calibre of renal pelvis was measured and hydronephroses were morphologically classified grade 1–4. Results: Interrater agreement for renal capsule, collective system, hydronephrosis index, and renal parenchyma was good to excellent with ICC of 0.94, 0.87, 0.83 and 0.92 respectively (P < 0.001 each). Median Dice was 0.90 (capsule), 0.77 (collective system) and 0.88 (parenchyma). There was a positive correlation between conventional hydronephrosis grading and ultrasonic hydronephrosis index and between renal pelvis diameter and collective system volume (P < 0.001 both). Conclusion: Semiautomatic 3-D US volumetric analysis has a high degree of interrater agreement and enables reliable assessment of renal parenchymal volume in hydronephrosis. Volumes of the collective system and hydronephrosis index correlate with the extent of hydronephrosis. Trial registration: Trial registration number, DRKS00022772; date of registration, 07/31/2020. Graphical


  • Open Access

    Dose-Optimized Image Acquisition Parameters for Neonatal Chest Radiography: A Phantom Study Comparing Computed Radiography and Wireless Digital Radiography Needle Detectors

    by Kevin Rama, Michael Esser, Jakob Spogis, Friedrich Wanninger, Bernd Hoberg, Jürgen Frank Schäfer

    To determine dose-optimized image acquisition parameters for good image quality (IQ) in neonatal chest radiography with a computed radiography (CR) CsBr needle detector vs. a wireless digital radiography (DR) CsI detector using different doses and filters. Physical resolution of the two detectors in unprocessed imaging of a contrast-detail phantom was automatically evaluated. Post-processed chest radiographic imaging of a neonatal phantom was used for Visual Grading Analysis (VGA) by three radiology raters. Different kVp, mAs, and filter settings were used. The VGA score (VGAS) and dose area product (DAP) were used to determine image acquisition parameters and dose levels for good image quality. Pixel data from segments corresponding to visual grading characteristics (VGC) was used to calculate signal-to-noise ratio, contrast-to-noise ratio (CNR), and signal profile curves. These results were compared to the raters’ “ground truth” by Spearman’s correlation. The CR detector had the highest resolution in unprocessed imaging, although this was dependent on a tube voltage of 66 kVp (P < 0.001), and more so than the DR detector. The VGAS showed no significant difference between the CR needle and the DR CsI detectors at the same DAP, or when using standard pediatric filtering of 3.5 mm Al + 0.1 mm Cu (P > 0.05). A lung dose level of 0.017 mSv was needed for good IQ (effective dose (E): 0.010 mSv). This was achievable with different acquisition parameters. Out of 24 segments, only the CNR of bone-to-soft-tissue had a good Spearman’s correlation (ρ > 0.50) to raters’ VGAS (P < 0.0001), mostly due to problems with image registration. The CR needle and DR CsI detectors have comparable IQ in neonatal chest radiography. In this study, an E of approximately 0.010 mSv was needed for good IQ.


  • Open Access

    Application of low-dose FDG-PET/MRI for quantification of lung changes in pediatric patients with cystic fibrosis: a new inflammatory index

    by Ricarda Schwarz, Jürgen Frank Schäfer, Philipp Utz, Ute Graepler-Mainka, Helmut Dittmann, Mareen Sarah Kraus, Michael Esser

    Background: Clinical severity and progression of lung disease in cystic fibrosis (CF) are significantly influenced by the degree of lung inflammation. Non-invasive quantitative diagnostic tools are desirable to differentiate structural and inflammatory lung changes in order to help prevent chronic airway disease. This might also be helpful for the evaluation of longitudinal effects of novel therapeutics. Therefore, the present study assesses the quantification of inflammatory lung changes using positron emission tomography/magnetic resonance imaging (PET/MRI) of the lung in children and adolescents with CF and evaluates the possible impact of PET/MRI on individualized therapy management. Methods: This monocentric, retrospective cohort study included 19 PET/MRI of the lung performed between 2014 and 2021 in 11 patients (16±4.5 years, 8–22 years; 7 females). PET acquisition was performed at least 20 minutes after i.v. application of a weight-adjusted dose of fluor-18-fluorodeoxyglucose (18F-FDG) of 1 MBq/kgBW (mean effective dose, 1.3±0.4 mSv). Lesions of increased uptake were quantified based on standardized uptake values (SUV) and compared to background activity, liver and blood pool. Pulmonary changes were assessed using the established magnetic resonance imaging-CF (MR-CF) score and correlated to inflammatory lesions. Results were correlated to changes in therapy (initiation, modification or discontinuation of therapy after baseline-PET/MRI) based on the electronic medical records. Results: Uptake was highly increased in 5 cases, moderate in 4 cases, low in 7 cases, no uptake in 3 cases. Most MR-CF score points were assigned to peribronchitis (23%) and air trapping (23%). Metabolically increased lesions were mainly interpreted as consolidations (59%; PConclusions: In selected cases, pulmonary FDG-PET/MRI can help guide therapeutic decision-making and provide complementary information on CF-related lung changes to conventional MRI at a low radiation exposure.


  • Open Access

    Pancreatico-pleural fistula mimicking a recurrent congenital diaphragmatic hernia: A case report

    by Maximilian Holweg, Justus Lieber, Alfred Königsrainer, Steffen Hartleif, Michael Esser, Jörg Fuchs

  • Open Access

    Local MRI before and after Tumor Resection in Neuroblastoma: Impact of Residual Disease on Event Free Survival

    by Jürgen F. Schäfer, Sebastian Gassenmaier, Steven Warmann, Cristian Urla, Leonie Frauenfeld, Tim Flaadt, Maryanna Chaika, Michael Esser, Ilias Tsiflikas, Beate Timmermann, et al.

    (1) Background: The study aimed to investigate the influence of MRI-defined residual disease on local tumor control after resection of neuroblastic tumors in patients without routine adjuvant radiotherapy. (2) Methods: Patients, who underwent tumor resection between 2009 and 2019 and received a pre- and postoperative MRI, were included in this retrospective single-center study. Measurement of residual disease (RD) was performed using standardized criteria. Primary endpoint was the local or combined (local and metastatic) event free survival (EFS). (3) Results: Forty-one patients (20 female) with median age of 39 months were analyzed. Risk group analysis showed eleven low-, eight intermediate-, and twenty-two high-risk patients (LR, IR, HR). RD was found in 16 cases by MRI. A local or combined relapse or progression was found in nine patients of whom eight patients had RD (p = 0.0004). From the six patients with local or combined relapse in the HR group, five had RD (p = 0.005). Only one of 25 patients without RD had a local event. Mean EFS (month) was significantly higher if MRI showed no residual tumor (81 ± 5 vs. 43 ± 9; p = 0.0014) for the total cohort and the HR subgroup (62 ± 7 vs. 31 ± 11; p = 0.016). (4) Conclusions: In our series, evidence of residual tumor, detectable by MRI, was associated with insufficient local control, resulting in relapses or local progression in 50% of patients. Only one of the patients without residual tumor had a local relapse.