MCMaria Vittoria Caruso

Maria Vittoria Caruso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maria Vittoria Caruso has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of IABP-Induced Abdominal Occlusions on Aortic Hemodynamics: A Patient-Specific Computational Evaluation

    by Maria Vittoria Caruso, Attilio Renzulli, Gionata Fragomeni

    Intraaortic balloon pump (IABP) is used as temporary mechanical assistance in case of cardiovascular diseases, even if different hemodynamic problems and, thus, clinical complications may happen, such as the decrease of visceral perfusion. A computational fluid dynamic (CFD) study was carried out to investigate the effects of different IABP-induced abdominal occlusions on patient-specific aortic flow. Two possible sizes (25 and 34 cm3) and two locations (2 and 3 cm) of the balloon were compared, modeling four abdominal occlusions and numerically reproducing IAB inflation/deflation behavior. The results highlighted that the perfusion in renal, mesenteric, and iliac arteries decreases when the abdominal occlusion increases with balloon inflation. The study illustrates also how the balloon size affects the flow in aorta vessels in both locations, and that the positioning is of little relevance for the 34 cm3balloon, whereas it influences the aortic flow very much in case of 25 cm3IAB. This analysis demonstrates how the IAB-induced occlusion may vary the abdominal circulation; therefore, the correct size and positioning are emphasized for patient’s outcome.


  • A Computational Study of Perfusion During the ExtraCorporeal Membrane Oxygenation (ECMO)

    by Maria Vittoria Caruso, Vera Gramigna, Attilio Renzulli, Gionata Fragomeni

    The extracorporeal membrane oxygenation (ECMO) is a common procedure of extracorporeal circulation (ECC) used in case of cardiopulmonary diseases. The major clinical complications are related to hemodynamic changes and to the mechanical shear stress. The aim of this study is to evaluate the effects of the modality of perfusion during ECMO, comparing the hemodynamic behavior generated by constant flow (normal modality) with the one obtained by pulsed perfusion induced by the intra-aortic balloon pump (IABP). To carry out the study, the computational fluid dynamic (CFD) approach was chosen, realizing a multi-scale model. The numerical results have highlighted that the IABP-induced pulsed perfusion increases both flow and pressure in the supraaortic vessels, even if the balloon makes the wall shear stress (WSS) pattern and the hemolysis index worse.

  • Open Access

    Support Tool for Anchoring System Optimization of Titanium Craniofacial Prostheses

    by Claudio Ciancio, Maria Vittoria Caruso, Gionata Fragomeni, Giuseppina Ambrogio

    MATEC Web of Conferences, open access proceedings in Materials science, Engineering and Chemistry

  • Computational analysis of aortic hemodynamics during total and partial extracorporeal membrane oxygenation and intra-aortic balloon pump support

    by Maria Vittoria Caruso, Vera Gramigna, Attilio Renzulli, Gionata Fragomeni

    Purpose: The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. Methods: The pulsatility was obtained by means of the intra-aortic balloon pump (IABP), and two different cases were investigated, considering a cardiac output (CO) of 5 L/ min: Case A - total assistance - the whole flow delivered through the ECMO arterial cannula; Case B - partial assistance - flow delivered half through the cannula and half through the aorta. Computational fluid dynamic (CFD) analysis was carried out using the multiscale approach to couple the 3D aorta model with the lumped parameter model (resistance boundary condition). Results: In case A pulsatility followed the balloon radius change, while in case B it was mostly influenced by the cardiac one. Furthermore, during total assistance, a blood stagnation occurred in the ascending aorta; in the case of partial assistance, the flow was orderly when the IABP was on and was chaotic when the balloon was off. Moreover, the mean arterial pressure (MAP) was higher in case B. The wall shear stress was worse in ascending aorta in case A. Conclusions: Partial support is hemodynamically advisable.


  • Influence of Aortic Outflow Cannula Orientation on Epiaortic Flow Pattern During Pulsed Cardiopulmonary Bypass

    by Maria Vittoria Caruso, Vera Gramigna, Giuseppe F. Serraino, Attilio Renzulli, Gionata Fragomeni


  • Computational analysis of stenosis geometry effects on right coronary hemodynamics

    by Maria Vittoria Caruso, Salvatore De Rosa, Ciro Indolfi, Gionata Fragomeni

    Coronary artery disease (CAD) is one of the most frequent causes of death in western countries. It is characterized by the presence of coronary artery stenosis that can be flow-limiting or susceptible to rupture, triggering intracoronary thrombosis and -consequently- an acute myocardial infarction. For these reasons, hemodynamic alterations associated to the presence of coronary stenosis are of large relevance. Aim of this study was to numerically investigate the effect of stenosis geometry on hemodynamics, comparing three different shapes with an equivalent stenotic lumen. A right coronary artery (RCA) was reconstructed from the angiogram of a patient. Flow pattern analyses were performed using the computational fluid dynamic (CFD) approach, showing that the worst stenosis geometry is the elliptical one, characterized by areas with stasis, multidirectional velocity and high wall shear stress (WSS). On the other hand, the least dangerous stenosis is the parabolic one. However, the strongest predictor of pressure drop is not geometry but the minimal lumen area. In conclusion, while the minimal lumen area is associated to the trans-stenotic pressure drop, stenosis geometry has a significant impact on translesional flow pattern and WSS.


  • A computational fluid dynamics comparison between different outflow graft anastomosis locations of Left Ventricular Assist Device (LVAD) in a patient‐specific aortic model

    by Maria Vittoria Caruso, Vera Gramigna, Michele Rossi, Giuseppe Filiberto Serraino, Attilio Renzulli, Gionata Fragomeni

    Summary: Left ventricular assist devices (LVADs) are mechanical supports used in case of heart failure. Little is known as the height of the anastomosis in aorta might influence the hemodynamic. The aim of the study was to evaluate the fluid dynamic behavior due to the outflow graft placement of a continuous flow LVAD in ascending aorta and to identify the insertion site with the best hemodynamic profile.Computational fluid dynamic studies were carried out to analyze 4 different anastomosis locations in a patient‐specific aorta 3D model coupled with a lumped parameters model: 1 cm (case 1), 2 cm (case 2), 3 cm (case 3) and 4 cm (case 4) above the ST junction.In cases 1 and 2, epiaortic vessels presented a steady flow, while in cases 3 and 4 the flow was whirling. Moreover, maximum velocity occurred before: brachiocephalic trunk (case 1), brachiocephalic and left carotid arteries (case 2), left carotid and left subclavian artery (case 3) and left subclavian vessel and upper wall of aortic arch (case 4). Maximum time averaged wall shear stress (TAWSS) was located in: the ascending aorta (cases 1 and 2), the inferior curvature of the arch (case 3); at the origin of epiaortic vessels (case 4). Furthermore, a flow recirculation (cases 1 and 2), a blood stagnation and chaotic flow (cases 3 and 4) occurred above the aortic valve.The results suggested that the placement of the outflow graft at 2 cm above the ST junction gave the most favorable hemodynamic profile. Copyright © 2015 John Wiley & Sons, Ltd.


  • A numerical analysis of the aortic blood flow pattern during pulsed cardiopulmonary bypass

    by V. Gramigna, M.V. Caruso, M. Rossi, G.F. Serraino, A. Renzulli, G. Fragomeni

    In the modern era, stroke remains a main cause of morbidity after cardiac surgery despite continuing improvements in the cardiopulmonary bypass (CPB) techniques. The aim of the current work was to numerically investigate the blood flow in aorta and epiaortic vessels during standard and pulsed CPB, obtained with the intra-aortic balloon pump (IABP). A multi-scale model, realized coupling a 3D computational fluid dynamics study with a 0D model, was developed and validated with in vivo data. The presence of IABP improved the flow pattern directed towards the epiaortic vessels with a mean flow increase of 6.3% and reduced flow vorticity.


  • Open Access

    Automated Sensing System for Monitoring of Road Surface Quality by Mobile Devices

    by Astarita Vittorio, Vaiana Rosolino, Iuele Teresa, Caruso Maria Vittoria, P. Giofrè Vincenzo, De Masi Francesco


  • Open Access

    Driving Behavior and Traffic Safety: An Acceleration-Based Safety Evaluation Procedure for Smartphones

    by Rosolino Vaiana, Teresa Iuele, Vittorio Astarita, Maria Vittoria Caruso, Antonio Tassitani, Claudio Zaffino, Vincenzo Pasquale Giofrè

    Traffic safety and energy efficiency of vehicles are strictly related to driver’s behavior. The scientific literature has investigated on some specific dynamic parameters that, among the others, can be used as a measure of unsafe or aggressive driving style such as longitudinal and lateral acceleration of vehicle. Moreover, the use of modern mobile devices (smartphones and tablets), and their internal sensors (GPS receivers, three-axes accelerometers), allows road users to receive real time information and feedback that can be useful to increase awareness of drivers and promote safety. This paper focuses on the development of a prototype mobile application that can evaluate the grade of safety that drivers are keeping on the road by measuring of accelerations (longitudinal and lateral) and warning for users when it can be convenient to correct their driving style. The aggressiveness is evaluated by plotting vehicle’s acceleration on a g-g diagram specially studied and designed, where horizontal and lateral acceleration is displayed inside areas of “Good Driving Style”. Several experimental tests were carried out with different drivers and cars in order to estimate the system accuracy and the usability of the application. This work is part of the wider research project M2M, Mobile to Mobility: Information and communication technology systems for road traffic safety (PON National Operational Program for Research and Competitiveness 2007-2013) which is based on the use of mobile sensor computing systems for giving real-time information in order to reduce risks and to make the transportation system more safe and comfortable.