Oscar Albis-Donado
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oscar Albis-Donado has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Giovanna Casale-Vargas
Ophthalmologist, Department of Cornea and Uveitis Section, Omesvi Diagnostic Group, Mexico City, Mexico
6 shared publicationsShibal Bhartiya
Department of Glaucoma Services, Fortis Memorial Research Institute, Gurugram, Haryana, India
6 shared publicationsFélix Gil-Carrasco
Department of Glaucoma, Association for the Prevention of Blindness, Coyoacan, Mexico
4 shared publicationsNadia Rios-Acosta
Department of Glaucoma, Instituto Mexicano de Oftalmología IAP, Querétaro City, Querétaro, México
3 shared publicationsRafael Castaneda-Diez
Department of Glaucoma, Association for the Prevention of Blindness, Coyoacan, Mexico
3 shared publicationsRavi Thomas
Department of Glaucoma, Cataract, Clinical Epidemiology Queensland Eye Institute, Melbourne, Australia
3 shared publications
Latest Publications
- 24 November 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
Multidimensional Modeling to Improve Intraocular Pressure Estimation in Glaucoma
Precis: A scalable multidimensional framework integrating environmental, structural, geometric, and dynamic information substantially improved agreement with dynamic contour tonometry compared with traditional corneal thickness-based correction methods. Purpose: To develop and evaluate a multidimensional framework for estimating intraocular pressure (IOP) in glaucoma eyes using dynamic contour tonometry (DCT) as the reference method. Methods: This retrospective analysis included 94 eyes from 47 patients in a model-development cohort (MDC) and 40 eyes from 20 patients in a temporal validation cohort (VC). DCT, Goldmann applanation tonometry (GAT), rebound tonometry (iCare TA01), and keratometry were obtained at 2.49 km. Environmental, structural, geometric, and dynamic components were incorporated. Geometric and dynamic coefficients were optimized in the MDC and applied to the VC. Agreement with DCT was assessed using bias, mean absolute deviation (MAD), Bland–Altman limits of agreement (LoA), and proportional-bias analysis. Results: In the MDC, DCT–GAT bias was 3.05 mm Hg (MAD 3.19; LoA width 7.57). The environmental-structural model reduced bias to −0.70 mm Hg. Adding geometry produced a bias of −0.51 mm Hg and LoA width of 8.06 mm Hg, whereas adding the dynamic component produced a bias of −0.91 mmHg, MAD 1.57, and LoA width 6.89 mm Hg. The integrated model showed a bias of −0.72 mm Hg, MAD 1.51, and LoA width 7.21 mm Hg. In the VC, integrated-model bias was −0.58 mm Hg, MAD 1.39, and LoA width 6.33 mm Hg. Conclusions: Multidimensional modeling improved agreement with DCT, with the dynamic component providing the greatest improvement in precision. Further validation in independent populations and at different altitudes is needed.
- 24 November 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
Multidimensional Modeling to Improve Intraocular Pressure Estimation in Glaucoma
Precis: A scalable multidimensional framework integrating environmental, structural, geometric, and dynamic information substantially improved agreement with dynamic contour tonometry compared with traditional corneal thickness-based correction methods. Purpose: To develop and evaluate a multidimensional framework for estimating intraocular pressure (IOP) in glaucoma eyes using dynamic contour tonometry (DCT) as the reference method. Methods: This retrospective analysis included 94 eyes from 47 patients in a model-development cohort (MDC) and 40 eyes from 20 patients in a temporal validation cohort (VC). DCT, Goldmann applanation tonometry (GAT), rebound tonometry (iCare TA01), and keratometry were obtained at 2.49 km. Environmental, structural, geometric, and dynamic components were incorporated. Geometric and dynamic coefficients were optimized in the MDC and applied to the VC. Agreement with DCT was assessed using bias, mean absolute deviation (MAD), Bland–Altman limits of agreement (LoA), and proportional-bias analysis. Results: In the MDC, DCT–GAT bias was 3.05 mm Hg (MAD 3.19; LoA width 7.57). The environmental-structural model reduced bias to −0.70 mm Hg. Adding geometry produced a bias of −0.51 mm Hg and LoA width of 8.06 mm Hg, whereas adding the dynamic component produced a bias of −0.91 mmHg, MAD 1.57, and LoA width 6.89 mm Hg. The integrated model showed a bias of −0.72 mm Hg, MAD 1.51, and LoA width 7.21 mm Hg. In the VC, integrated-model bias was −0.58 mm Hg, MAD 1.39, and LoA width 6.33 mm Hg. Conclusions: Multidimensional modeling improved agreement with DCT, with the dynamic component providing the greatest improvement in precision. Further validation in independent populations and at different altitudes is needed.
- Open Access
- 15 December 2023
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (Suppl 3) , S398-S403
The influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: An ecological meta-analysis
Purpose: A meta-analysis found that including atmospheric pressure as altitude in generalized linear models reveals higher differences between Goldmann tonometry and Pascal dynamic contour tonometry at higher altitudes, with the difference increasing in thinner corneas. To examine the difference in intraocular pressure (IOP) measurements by using Goldman applanation tonometry (GAT) and dynamic contour tonometer (DCT) tonometry in published literature and determine the influence of central corneal thickness (CCT), age, and altitude on that difference. Methods: Articles that compare GAT and DCT were selected for an extensive literature review, and the location and altitude of the research centers were found online. CCT and age were analyzed as covariates, when available. Results: A total of 157 studies including 24,211 eyes of 20,214 patients were included in the study. The results showed that the difference between DCT and GAT was higher at higher altitudes above sea level and increased with thinner corneas. However, the results were different in eyes with corneal transplants, where altitude and CCT had less influence, and in those post-refractive surgery where age was found to influence the difference. Theoretical correction formulas using altitude, CCT, and age were derived from this meta-analysis, but their accuracy and usefulness in clinical practice need validation. Conclusion: The findings suggest that there is a higher risk of underestimating IOP when the Goldmann tonometer is used at a higher altitude, particularly in eyes with glaucoma, thinner corneas, or corneal refractive surgery. Further research is needed to validate the accuracy of the correction formulas derived from this meta-analysis in clinical practice.
- 15 December 2023
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (Suppl 3) , S398-S403
Open AccessThe influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: An ecological meta-analysis
Purpose: A meta-analysis found that including atmospheric pressure as altitude in generalized linear models reveals higher differences between Goldmann tonometry and Pascal dynamic contour tonometry at higher altitudes, with the difference increasing in thinner corneas. To examine the difference in intraocular pressure (IOP) measurements by using Goldman applanation tonometry (GAT) and dynamic contour tonometer (DCT) tonometry in published literature and determine the influence of central corneal thickness (CCT), age, and altitude on that difference. Methods: Articles that compare GAT and DCT were selected for an extensive literature review, and the location and altitude of the research centers were found online. CCT and age were analyzed as covariates, when available. Results: A total of 157 studies including 24,211 eyes of 20,214 patients were included in the study. The results showed that the difference between DCT and GAT was higher at higher altitudes above sea level and increased with thinner corneas. However, the results were different in eyes with corneal transplants, where altitude and CCT had less influence, and in those post-refractive surgery where age was found to influence the difference. Theoretical correction formulas using altitude, CCT, and age were derived from this meta-analysis, but their accuracy and usefulness in clinical practice need validation. Conclusion: The findings suggest that there is a higher risk of underestimating IOP when the Goldmann tonometer is used at a higher altitude, particularly in eyes with glaucoma, thinner corneas, or corneal refractive surgery. Further research is needed to validate the accuracy of the correction formulas derived from this meta-analysis in clinical practice.
- 23 September 2023
- Published by Elsevier in Archivos de la Sociedad Española de Oftalmología (English Edition)
- Vol. 98 (11) , 640-645
Results of a modified ab-external trabeculectomy surgical technique in patients with open angle glaucoma
- 23 September 2023
- Published by Elsevier in Archivos de la Sociedad Española de Oftalmología (English Edition)
- Vol. 98 (11) , 640-645
Results of a modified ab-external trabeculectomy surgical technique in patients with open angle glaucoma
- Open Access
- 13 May 2023
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 17 (1) , 37-39
New Gonioscopy Technique for Finding Schwalbe\'s Line: The Ortiz Maneuver
A new technique for performing gonioscopy that facilitates finding Schwalbe´s line, and lowers the amount of time and light that enters through the pupil is presented. The technique is an alternative to the classic corneal wedge technique and is feasible in the horizontal quadrants without further adjustments to the slit lamp, in contrast to the tilting usually needed for these quadrants. Clinical photos and online videos are presented. Albis-Donado O, Ortiz-Arismendi GE, Bhartiya S. New Gonioscopy Technique for Finding Schwalbe's Line: The Ortiz Maneuver. J Curr Glaucoma Pract 2023;17(1):37-39.
- 13 May 2023
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 17 (1) , 37-39
Open AccessNew Gonioscopy Technique for Finding Schwalbe\'s Line: The Ortiz Maneuver
A new technique for performing gonioscopy that facilitates finding Schwalbe´s line, and lowers the amount of time and light that enters through the pupil is presented. The technique is an alternative to the classic corneal wedge technique and is feasible in the horizontal quadrants without further adjustments to the slit lamp, in contrast to the tilting usually needed for these quadrants. Clinical photos and online videos are presented. Albis-Donado O, Ortiz-Arismendi GE, Bhartiya S. New Gonioscopy Technique for Finding Schwalbe's Line: The Ortiz Maneuver. J Curr Glaucoma Pract 2023;17(1):37-39.
- 30 June 2020
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 29 (9) , 756-760
Effects of Acute Atmospheric Pressure Changes on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Normal Individuals: A Pilot Study
Précis: Intraocular pressure measurement differences with Goldmann applanation tonometry and Dynamic contour tonometry are affected by atmospheric pressure inside a hyperbaric chamber. Purpose: To compare intraocular pressure measurements obtained with Goldmann applanation tonometry (GAT) and Dynamic contour tonometry (DCT) in 22 normal individuals at different atmospheric pressures simulated in a hyperbaric chamber. Methods: The intraocular pressure of both eyes of 22 healthy volunteers was measured using GAT and DCT at four different atmospheric pressure levels. Starting at one Queretaro atmospheric pressure (QATM) the IOP was measured with GAT and DCT. The atmospheric pressure was then increased to 1.1 QATM (equivalent to 1032 m above sea level), 1.2 QATM (equivalent to 315 m above sea level) and 1.25 QATM (equivalent to sea level), starting 5 minutes after reaching each level. The limits of agreement between various measurements with each tonometer were calculated using the Bland Altman plots. Results: The first 4 subjects were used to measure feasibility, consistency, variability and the time needed for IOP to return to baseline after each atmospheric pressure increase. For the entire 44 eyes mean GAT IOP at 1 QATM was 12.23▒mmHg (range 8-20▒mmHg, SD 2.84) and mean DCT was 16.36 (range 12.1-25.3, SD 2.84), a mean 4.14▒mmHg difference (range −0.1-7.5▒mmHg, SD 1.62, PPPP<0.001). Generalized estimating equations for performing linear regression multivariable analysis using atmospheric pressure, expressed as altitude, and age as covariates, shows that the difference between GAT and DCT increases by 1▒mmHg per 673▒m of increase of altitude above sea level. Age was not a significant predictor. Conclusions: Acute changes in atmospheric pressure induce changes in IOP measurements for both GAT and DCT, and in different directions. Despite the limitation of sample size, it may be postulated that the difference of IOP measurements between the two tonometers increases with lower atmospheric pressures.
- 30 June 2020
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 29 (9) , 756-760
Effects of Acute Atmospheric Pressure Changes on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Normal Individuals: A Pilot Study
Précis: Intraocular pressure measurement differences with Goldmann applanation tonometry and Dynamic contour tonometry are affected by atmospheric pressure inside a hyperbaric chamber. Purpose: To compare intraocular pressure measurements obtained with Goldmann applanation tonometry (GAT) and Dynamic contour tonometry (DCT) in 22 normal individuals at different atmospheric pressures simulated in a hyperbaric chamber. Methods: The intraocular pressure of both eyes of 22 healthy volunteers was measured using GAT and DCT at four different atmospheric pressure levels. Starting at one Queretaro atmospheric pressure (QATM) the IOP was measured with GAT and DCT. The atmospheric pressure was then increased to 1.1 QATM (equivalent to 1032 m above sea level), 1.2 QATM (equivalent to 315 m above sea level) and 1.25 QATM (equivalent to sea level), starting 5 minutes after reaching each level. The limits of agreement between various measurements with each tonometer were calculated using the Bland Altman plots. Results: The first 4 subjects were used to measure feasibility, consistency, variability and the time needed for IOP to return to baseline after each atmospheric pressure increase. For the entire 44 eyes mean GAT IOP at 1 QATM was 12.23▒mmHg (range 8-20▒mmHg, SD 2.84) and mean DCT was 16.36 (range 12.1-25.3, SD 2.84), a mean 4.14▒mmHg difference (range −0.1-7.5▒mmHg, SD 1.62, PPPP<0.001). Generalized estimating equations for performing linear regression multivariable analysis using atmospheric pressure, expressed as altitude, and age as covariates, shows that the difference between GAT and DCT increases by 1▒mmHg per 673▒m of increase of altitude above sea level. Age was not a significant predictor. Conclusions: Acute changes in atmospheric pressure induce changes in IOP measurements for both GAT and DCT, and in different directions. Despite the limitation of sample size, it may be postulated that the difference of IOP measurements between the two tonometers increases with lower atmospheric pressures.
- 30 September 2018
- Published by Springer Nature
- p. 37-47
Pediatric Examination Under Anesthesia
- Open Access
- 1 April 2018
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 12 (1) , 40-44
Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude
To ascertain differences in intraocular pressure (IOP) measurement and their repeatability between dynamic contour tonometry (DCT) and Goldmann/Perkins applanation tonometry (GAT) at two different atmospheric pressures. Forty-one eyes of 41 healthy consenting subjects were enrolled for this observational, cross-sectional study. Pachymetry and IOP measurements with DCT and GAT for both eyes of each subject at Acapulco (0 m from sea level) and at Mexico City (2,234 m from sea level) were done by the same observer. The IOP was compared between tonometers at each of the altitudes, and also for repeatability of each tonometer at different altitudes. Pearson’s correlation coefficient and Bland-Altman plots were used to assess reliability of measurements and their differences at the two altitudes. The mean age of patients was 41.7 (28-66 years); 22 were females. Mean IOP with DCT was 16.1 ± 2.2 mm Hg at sea level and 15.9 ± 2.1 mm Hg at 2,234 m above sea level, not a significant difference. Mean GAT IOP at the two altitudes was 13.1 ± 1.8 and 11.5 ± 1.7 mm Hg respectively, a statistically sig -nificant difference. In contrast, central corneal thickness (CCT) was not significantly changed (548.3 to 549.4 μm, p = 0.496). Repeatability of single-observer measurements with GAT remains clinically acceptable, but not at different altitudes. The DCT seems to more consistently measure a similar IOP at different altitudes in the same subjects. The two tonometers may not be used interchangeably in the serial follow-up of patients at any of the altitudes. How to cite this article: Albis-Donado O, Bhartiya S, Gil-Reyes M, Casale-Vargas G, Arreguin-Rebollar N, Kahook MY. Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude. J Curr Glaucoma Pract 2018;12(1):40-44.
- 1 April 2018
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 12 (1) , 40-44
Open AccessCitius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude
To ascertain differences in intraocular pressure (IOP) measurement and their repeatability between dynamic contour tonometry (DCT) and Goldmann/Perkins applanation tonometry (GAT) at two different atmospheric pressures. Forty-one eyes of 41 healthy consenting subjects were enrolled for this observational, cross-sectional study. Pachymetry and IOP measurements with DCT and GAT for both eyes of each subject at Acapulco (0 m from sea level) and at Mexico City (2,234 m from sea level) were done by the same observer. The IOP was compared between tonometers at each of the altitudes, and also for repeatability of each tonometer at different altitudes. Pearson’s correlation coefficient and Bland-Altman plots were used to assess reliability of measurements and their differences at the two altitudes. The mean age of patients was 41.7 (28-66 years); 22 were females. Mean IOP with DCT was 16.1 ± 2.2 mm Hg at sea level and 15.9 ± 2.1 mm Hg at 2,234 m above sea level, not a significant difference. Mean GAT IOP at the two altitudes was 13.1 ± 1.8 and 11.5 ± 1.7 mm Hg respectively, a statistically sig -nificant difference. In contrast, central corneal thickness (CCT) was not significantly changed (548.3 to 549.4 μm, p = 0.496). Repeatability of single-observer measurements with GAT remains clinically acceptable, but not at different altitudes. The DCT seems to more consistently measure a similar IOP at different altitudes in the same subjects. The two tonometers may not be used interchangeably in the serial follow-up of patients at any of the altitudes. How to cite this article: Albis-Donado O, Bhartiya S, Gil-Reyes M, Casale-Vargas G, Arreguin-Rebollar N, Kahook MY. Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude. J Curr Glaucoma Pract 2018;12(1):40-44.
- 1 January 2017
- Published by Jaypee Brothers Medical Publishing
- p. 41
Trabeculectomy versus Tube
- 1 January 2017
- Published by Jaypee Brothers Medical Publishing
- p. 68
Tube Complications