NDNorbert Danz

Norbert Danz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Norbert Danz has a total of 226 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Highly Sensitive Detection of Anti-SARS-CoV-2 Antibodies in Human Serum Using Bloch Surface Wave Biosensor

    by Anastasiia Gaganina, Agostino Occhicone, Daniele Chiappetta, Paola Di Matteo, Norbert Danz, Matteo Allegretti, Peter Munzert, Chiara Mandoj, Francesco Michelotti, Alberto Sinibaldi

    Accurate and sensitive antibody detection remains critical for advanced COVID-19 diagnostics and monitoring SARS-CoV-2 immunity. This study presents a highly sensitive technique for detecting anti-SARS-CoV-2 antibodies in human serum using an integrated photonic sensing platform. The platform utilizes disposable one-dimensional photonic crystal biochips engineered to sustain Bloch Surface Waves. The biochips are integrated into a custom-made optical set-up, which is capable of dual-mode detection: label-free refractometry and label-based fluorescence. Tests on human serum, including negative controls and positive samples from a recovered COVID-19 patient, confirmed the platform’s effective performance. In fluorescence mode, clear discrimination between positive and negative samples was achieved down to a 1:104 serum dilution, with an optimal operating range centered around 1:103 dilution. These results demonstrate the potential of the technique as a highly sensitive and versatile platform for antibody detection, with significant relevance for advanced COVID-19 diagnostics.


  • On-skin, micro-objective enabled camera module for speckle contrast optical spectroscopy/tomography

    by Andres Quiroga, Lorenzo Cortese, Manish Verma, Peter Dannberg, Ilias Tachtsidis, Norbert Danz, Turgut Durduran

    In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 micro-objectives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio (>4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices.


  • Open Access

    Aberration corrected hybrid lens realized by direct bonding of a bi-convex cylindrical lens and a microstructured wafer

    by Pascal Birckigt, Carolin Rothhardt, Gerd Harnisch, Gilbert Leibeling, Robert Leitel, Norbert Danz, Johanna K. Karl, Stefan Risse, Uwe D. Zeitner


  • Open Access

    On-skin, micro-objective enabled camera module for speckle contrast optical spectroscopy/tomography

    by Andres Quiroga, Lorenzo Cortese, Manish Verma, Peter Dannberg, Ilias Tachtsidis, Norbert Danz, Turgut Durduran

    In this paper, we introduce a speckle contrast optical spectroscopy/tomography (SCOS/SCOT) configuration based on an integrated imaging approach exploiting 113 micro-objetives mounted on a commercial CMOS camera that operates without fiber coupling, suitable for direct skin contact measurements and simultaneous multiple source-detector separation acquisitions. This compact system was validated ex vivo on phantoms and in vivo by monitoring the blood flow on the forearm muscle of a healthy human subject. The measurements, performed at multiple source-detector separations and camera exposure times, demonstrate excellent agreement with the theory based on the correlation-diffusion model. In vivo data demonstrate the capability of tracking pulsatile blood flow with a high signal-to-noise ratio ( > 4 harmonics of the cardiac pulse frequency detected) and sensitivity to small changes in muscle blood flow. This micro-objective array-based design overcomes a key challenge towards wearable SCOS/SCOT devices.


  • Direct Competitive Assay for ERBB2 Detection in Breast Cancer Cell Lysates Using 1-D Photonic Crystals-Based Biochips

    by Alberto Sinibaldi, Matteo Allegretti, Norbert Danz, Elena Giordani, Peter Munzert, Agostino Occhicone, Patrizio Giacomini, Francesco Michelotti

    ERBB2 is a member of the tyrosine kinase receptor family, a major cancer driver, and a recognized therapeutic target in many cancers, most importantly breast cancer. Its presence in soluble form in blood correlates with tumor expression and may have implications for diagnostic and therapeutic decisions. Herein, we develop a new approach that makes use of a direct competitive ERBB2 assay and one-dimensional photonic crystal-based biochips. Such biochips permit to operate in a combined label-free/fluorescence mode enabling ERBB2 biosensing in lysates from selected breast cancer cells, either ERBB2-positive (SK-BR 3, BT474), or ERBB2-negative (T47D). Moreover, our biochips allow to collect enhanced fluorescence spectra providing a highly specific ERBB2 detection in the three model cell lines. The main advantage of the assay developed in this work lies in the single-step detection procedure that reduces assay turnaround time to less than 20 minutes. This latter feature confirms the great potential of the technique in the rapid detection of ERBB2 in complex biological media.


  • Open Access

    Enhanced Fluorescence Detection of Interleukin 10 by Means of 1D Photonic Crystals

    by Agostino Occhicone, Paola Del Porto, Norbert Danz, Peter Munzert, Alberto Sinibaldi, Francesco Michelotti

    In the present communication, we report on the exploitation of a Bloch surface wave-enhanced fluorescence scheme for the detection of Interleukin (IL)-10 in a protein-rich buffer mimicking a biological sample. IL-10 is a cytokine known for its potent anti-inflammatory and immunosuppressive effects. It is considered a valuable biomarker for prognostic prediction for both solid tumors and hematological malignancies, and recently, a distinguishing feature of hyperinflammation during severe viral infections. To demonstrate the validity of the technique, we transferred all the reagents and working concentrations used in a gold-standard technique, such as ELISA, to our assay, with a substantial reduction in the execution time and without using any enzymatic amplification during IL-10 recognition. We estimate a limit of detection (LoD) in terms of the concentration of IL-10 in solution of the order of 110 pg/mL (5.8 pM) with a 14% accuracy; in other terms, the presented technique is compatible with the assay range and resolution (1.6 pM) of commercial gold-standard ELISA kits. Moreover, such LoD successfully matches the concentrations reported in literature for IL-10 detection in COVID-19 patients, making the BSW-based sensors a viable solution for rapid and accurate screening of COVID-19-related molecules.


  • Open Access

    Optical multiplexed bioassays on photonic crystals for breast cancer biomarker detection

    by Tommaso Pileri, Alberto Sinibaldi, Agostino Occhicone, Elena Giordani, Matteo Allegretti, Peter Munzert, Frank Sonntag, Norbert Danz, Patrizio Giacomini, Francesco Michelotti

    An optical biosensor for proteomic breast cancer biomarker detection in complex media is presented. Bloch Surface Waves (BSW) excited onto one dimensional photonic crystal (1DPC) were used to probe the interaction of HER2 with three antibody species and an inert protein (Bovine Serum Albumin - BSA). The optical system combines Label-Free readings to track the bioassay real-time development and Fluorescence emission quantification to evaluate the level of specific interaction between the antigen and the antibodies. The results confirm a distinguishable level of affinity between the antibodies and the analyte according to their specificity even at low antibody surface density (about 1173 pg/mm2).

  • Open Access

    Spectral analysis of organic LED emitters’ orientation in thin layers by resonant emission on dielectric stacks

    by Norbert Danz, Agostino Occhicone, Christof Pflumm, Peter Munzert, Francesco Michelotti, Dirk Michaelis

    Purposely tailored thin film stacks sustaining surface waves have been utilized to create a unique link between emission angle and wavelength of fluorescent dye molecules. The knowledge of the thin film stack’s properties allows us to derive the intrinsically emitted luminescence spectrum as well as to gain information about the orientation of fluorophores from angularly resolved experiments. This corresponds to replacing all the equipment necessary for polarized spectroscopy with a single smart thin film stack, potentially enabling single shot analyses in the future. The experimental results agree well with those from other established techniques, when analyzing the Rubrene derivative in a 2,4,6-tris(biphenyl-3-yl)-1,3,5-triazine (T2T) host used for the fabrication of optimized organic light-emitting diodes. The findings illustrate how resonant layered stacks can be applied to integrated spectroscopic analyses.


  • Bioassay engineering: a combined label-free and fluorescence approach to optimize HER2 detection in complex biological media

    by Alberto Sinibaldi, Andrea Doricchi, Tommaso Pileri, Matteo Allegretti, Norbert Danz, Peter Munzert, Elena Giordani, Patrizio Giacomini, Francesco Michelotti

    We report on the combined label-free/fluorescence use of one-dimensional photonic crystals to optimize cancer biomarker detection in complex biological media. The optimization of the assay working parameters permits us to maximize the final response of the biosensor. The detection approach utilizes a sandwich assay, in which one-dimensional photonic crystals sustaining Bloch surface waves are modified with monoclonal antibodies in order to guarantee high specificity during biological recognition. The multiple outcomes generated by such optimization experiments permitted us to determine the effective capture efficiency and the repeatability of the immobilization process, which was estimated to be close to 5%. By exploiting the resolution of the fluorescence operation mode, we studied non-specific interactions in different blocking agents, different analyte diluting buffers, and diverse concentrations of the detection antibody. As a clinically relevant biomarker, we selected the trans-membrane receptor tyrosine kinase HER2. HER2 regulates a variety of cell proliferation, growth, and differentiation pathways and its over-expression occurs in approximately 20–30% of breast cancer worldwide. As a final application, we transferred all the optimized working parameters to HER2 cancer biomarker assays in a complex biological environment. The label-free and fluorescence results obtained by analyzing MCF-7 (HER2 low positive) and 32D (HER2 negative) cell lysates demonstrate that we can successfully discriminate the two lysates.


  • Towards an ultrathin multi-aperture microscope

    by Stephan Schacke, René Berlich, Bernd Höfer, Peter Dannberg, Ben Zaage, C. Damm, Erik Beckert, Norbert Danz

    Recent biomedical developments towards compact, mobile, decentralized and system-integrated diagnostic platforms require automated and miniaturized microscopy technologies. Reducing system dimensions by downsizing classical single aperture optics limits either the field of view (FOV) or resolution. However, arranging multiple miniaturized objectives in parallel allows overcoming this restraint by decoupling the system’s FOV from the axial system length. Based on this principle, we propose a thin multi-aperture microscope concept to image a large FOV with μm resolution. Due to a total optical system length of only 10 mm, the imaging optics can be integrated into conventional camera housings. The approach’s potential is demonstrated by introducing a first prototype specified by life science requirements. The final system enables for bright field and fluorescence imaging of (1) multiple separated object fields simultaneously (e.g. parallel monitoring in microfluidics applications) or (2) extended continuous object areas via sample scanning. Hence, the micro-objective array approach provides a microscopy solution for biomedical applications with tight space requirements like point-of-care diagnostic devices, cell incubator microscopes and organ/lab-on-chip long term monitoring.