Chung-Chieh Fang
Chung-Chieh Fang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Eyad H. Abed
University of Maryland
5 shared publicationsRichard Redl
Redl Consulting, Montevaux 14, CH-1726 Farvagny-le-Petit, Switzerland
3 shared publicationsE.H. Abed
2 shared publicationsB. Balachandran
1 shared publication- Ching-Jan Chen
Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
1 shared publication - Eyad H. Abed
University of Maryland
1 shared publication
Latest Publications
- 18 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (3) , 2723-2729
Switching Frequency Determination of DC–DC Converters With Hysteretic Control
Hysteretic control provides unique advantages in dc–dc converter applications but it is less popular than other types of control because the switching frequency depends on the operating point, the feedback ripple, and the component parasitics. Furthermore, it is difficult to predict the frequency due to the complex interaction of those factors. This paper proposes harmonic balance analysis to systematically determine the switching frequency of the buck and boost-like converters with hysteretic current control, and extends the method to buck converters with hysteretic voltage control. The analysis includes the most important second-order effects (feedback ripple, component parasitics, a second output capacitor, and switching delays). For the less complex cases the switching frequency is expressed in closed form, and for the more complex cases the paper proposes a graphical solution. The predictions are verified by simulations and, for the buck converter with hysteretic current control, by experiments. The derived results are useful for designing a converter with predictable switching frequency, and can also be employed during the design process of a converter with synchronized or stabilized frequency. Given an arbitrary control scheme or circuit variation, the switching frequency can be readily obtained by following the proposed approach.
- 18 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (3) , 2723-2729
Switching Frequency Determination of DC–DC Converters With Hysteretic Control
Hysteretic control provides unique advantages in dc–dc converter applications but it is less popular than other types of control because the switching frequency depends on the operating point, the feedback ripple, and the component parasitics. Furthermore, it is difficult to predict the frequency due to the complex interaction of those factors. This paper proposes harmonic balance analysis to systematically determine the switching frequency of the buck and boost-like converters with hysteretic current control, and extends the method to buck converters with hysteretic voltage control. The analysis includes the most important second-order effects (feedback ripple, component parasitics, a second output capacitor, and switching delays). For the less complex cases the switching frequency is expressed in closed form, and for the more complex cases the paper proposes a graphical solution. The predictions are verified by simulations and, for the buck converter with hysteretic current control, by experiments. The derived results are useful for designing a converter with predictable switching frequency, and can also be employed during the design process of a converter with synchronized or stabilized frequency. Given an arbitrary control scheme or circuit variation, the switching frequency can be readily obtained by following the proposed approach.
- 8 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 31 (2) , 1657-1664
Subharmonic Instability Limits for ${\rm V}^2$ -Controlled Buck Converter With Outer Loop Closed/OpenGeneral closed-form subharmonic oscillation conditions are obtained for V 2 -controlled buck converters. Both constant switching period and constant on-time operations are analyzed with the outer voltage loop closed or open. Once an arbitrary linear feedback is given, the associated closed-form stability condition of the converter is readily obtained. Past research results based on the describing function technique and the Floquet theory become special cases. This paper provides an alternative and easier method to analyze subharmonic instability.
- 8 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 31 (2) , 1657-1664
Subharmonic Instability Limits for ${\rm V}^2$ -Controlled Buck Converter With Outer Loop Closed/OpenGeneral closed-form subharmonic oscillation conditions are obtained for V 2 -controlled buck converters. Both constant switching period and constant on-time operations are analyzed with the outer voltage loop closed or open. Once an arbitrary linear feedback is given, the associated closed-form stability condition of the converter is readily obtained. Past research results based on the describing function technique and the Floquet theory become special cases. This paper provides an alternative and easier method to analyze subharmonic instability.
- 7 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 30 (7) , 4035-4036
Prediction of Subharmonic Oscillation in ${\bf{\rm I}^2}$ Controlled Buck Converters in CCMA recent paper proposed I 2 average-current control with constant switching period (CSP) or constant on-time (COT) operation in continuous conduction mcontinuous conduction modeode (CCM). The small-signal analysis was presented, but only for the COT case. No instability or its condition was reported. In this note, unified subharmonic oscillation conditions are derived for both CSP and COT buck converters. The effects of feedback gain, turn-off delay, and stabilizing ramp slope are considered. The results can be extended to other converters or control schemes.
- 7 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 30 (7) , 4035-4036
Prediction of Subharmonic Oscillation in ${\bf{\rm I}^2}$ Controlled Buck Converters in CCMA recent paper proposed I 2 average-current control with constant switching period (CSP) or constant on-time (COT) operation in continuous conduction mcontinuous conduction modeode (CCM). The small-signal analysis was presented, but only for the COT case. No instability or its condition was reported. In this note, unified subharmonic oscillation conditions are derived for both CSP and COT buck converters. The effects of feedback gain, turn-off delay, and stabilizing ramp slope are considered. The results can be extended to other converters or control schemes.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 29 (4) , 2135-2142
Subharmonic Stability Limits for the Buck Converter With Ripple-Based Constant On-Time Control and Feedback Filter
A general closed-form subharmonic stability condition is derived for the buck converter with ripple-based constant on-time control and a feedback filter. The turn-on delay is included in the analysis. Three types of filters are considered: low-pass filter (LPF), phase-boost filter (PBF), and inductor current feedback (ICF) which changes the feedback loop frequency response like a filter. With the LPF, the stability region is reduced. With the PBF or ICF, the stability region is enlarged. Stability conditions are determined both for the case of a single output capacitor and for the case of two parallel-connected output capacitors having widely different time constants. The past research results related to the feedback filters become special cases. All theoretical predictions are verified by experiments.
- 1 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 29 (4) , 2135-2142
Subharmonic Stability Limits for the Buck Converter With Ripple-Based Constant On-Time Control and Feedback Filter
A general closed-form subharmonic stability condition is derived for the buck converter with ripple-based constant on-time control and a feedback filter. The turn-on delay is included in the analysis. Three types of filters are considered: low-pass filter (LPF), phase-boost filter (PBF), and inductor current feedback (ICF) which changes the feedback loop frequency response like a filter. With the LPF, the stability region is reduced. With the PBF or ICF, the stability region is enlarged. Stability conditions are determined both for the case of a single output capacitor and for the case of two parallel-connected output capacitors having widely different time constants. The past research results related to the feedback filters become special cases. All theoretical predictions are verified by experiments.
- Open Access
- 20 March 2014
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 43 (8) , 995-1014
Unified subharmonic oscillation conditions for peak or average current mode control
Summary: This paper is an extension of the author's recent research in which only buck converters were analyzed. Similar analysis can be equally applied to other types of converters. In this paper, a unified model is proposed for buck, boost, and buck–boost converters under peak or average current mode control to predict the occurrence of subharmonic oscillation. Based on the unified model, the associated stability conditions are derived in closed forms. The same stability condition can be applied to buck, boost, and buck–boost converters. Based on the closed‐form conditions, the effects of various converter parameters including the compensator poles and zeros on the stability can be clearly seen, and these parameters can be consolidated into a few ones. High‐order compensators such as type‐II and PI compensators are considered. Some new plots are also proposed for design purpose to avoid the instability. The instability is found to be associated with large crossover frequency. A conservative stability condition, agreed with the past research, is derived. The effect of the voltage loop ripple on the instability is also analyzed. Copyright © 2014 John Wiley & Sons, Ltd.
- 20 March 2014
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 43 (8) , 995-1014
Open AccessUnified subharmonic oscillation conditions for peak or average current mode control
Summary: This paper is an extension of the author's recent research in which only buck converters were analyzed. Similar analysis can be equally applied to other types of converters. In this paper, a unified model is proposed for buck, boost, and buck–boost converters under peak or average current mode control to predict the occurrence of subharmonic oscillation. Based on the unified model, the associated stability conditions are derived in closed forms. The same stability condition can be applied to buck, boost, and buck–boost converters. Based on the closed‐form conditions, the effects of various converter parameters including the compensator poles and zeros on the stability can be clearly seen, and these parameters can be consolidated into a few ones. High‐order compensators such as type‐II and PI compensators are considered. Some new plots are also proposed for design purpose to avoid the instability. The instability is found to be associated with large crossover frequency. A conservative stability condition, agreed with the past research, is derived. The effect of the voltage loop ripple on the instability is also analyzed. Copyright © 2014 John Wiley & Sons, Ltd.
- 18 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 30 (2) , 1085-1092
Subharmonic Instability Limits for the Peak-Current-Controlled Buck Converter With Closed Voltage Feedback Loop
This paper presents the derivation and experimental verification of the closed-form subharmonic instability condition of the constant-frequency peak-current-controlled buck converter with closed voltage feedback loop. The well-known open-voltage-loop instability condition becomes a special case. The instability limits in the converter parameter space are readily obtained from the result. It is found that closing the voltage feedback loop tends to degrade the stability margin. One can clearly see the effects of all converter parameters (such as the pole, zero, and gain of the voltage-loop compensator, the equivalent series resistance of the output capacitor, the presence of a second output capacitor, and the switch turn-off delay) on the instability.
- 18 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 30 (2) , 1085-1092
Subharmonic Instability Limits for the Peak-Current-Controlled Buck Converter With Closed Voltage Feedback Loop
This paper presents the derivation and experimental verification of the closed-form subharmonic instability condition of the constant-frequency peak-current-controlled buck converter with closed voltage feedback loop. The well-known open-voltage-loop instability condition becomes a special case. The instability limits in the converter parameter space are readily obtained from the result. It is found that closing the voltage feedback loop tends to degrade the stability margin. One can clearly see the effects of all converter parameters (such as the pole, zero, and gain of the voltage-loop compensator, the equivalent series resistance of the output capacitor, the presence of a second output capacitor, and the switch turn-off delay) on the instability.
- 25 February 2014
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 77 (1-2) , 185-208
Instability conditions for a class of switched linear systems with switching delays based on sampled-data analysis: applications to DC–DC converters
- 25 February 2014
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 77 (1-2) , 185-208
Instability conditions for a class of switched linear systems with switching delays based on sampled-data analysis: applications to DC–DC converters
- Open Access
Unified Subharmonic Oscillation Conditions for Peak or Average Current Mode Control
This paper is an extension of the author's recent research in which only buck converters were analyzed. Similar analysis can be equally applied to other types of converters. In this paper, a unified model is proposed for buck, boost, and buck-boost converters under peak or average current mode control to predict the occurrence of subharmonic oscillation. Based on the unified model, the associated stability conditions are derived in closed forms. The same stability condition can be applied to buck, boost, and buck-boost converters. Based on the closed-form conditions, the effects of various converter parameters including the compensator poles and zeros on the stability can be clearly seen, and these parameters can be consolidated into a few ones. High-order compensators such as type-II and PI compensators are considered. Some new plots are also proposed for design purpose to avoid the instability. The instability is found to be associated with large crossover frequency. A conservative stability condition, agreed with the past research, is derived. The effect of the voltage loop ripple on the instability is also analyzed.
Open AccessUnified Subharmonic Oscillation Conditions for Peak or Average Current Mode Control
This paper is an extension of the author's recent research in which only buck converters were analyzed. Similar analysis can be equally applied to other types of converters. In this paper, a unified model is proposed for buck, boost, and buck-boost converters under peak or average current mode control to predict the occurrence of subharmonic oscillation. Based on the unified model, the associated stability conditions are derived in closed forms. The same stability condition can be applied to buck, boost, and buck-boost converters. Based on the closed-form conditions, the effects of various converter parameters including the compensator poles and zeros on the stability can be clearly seen, and these parameters can be consolidated into a few ones. High-order compensators such as type-II and PI compensators are considered. Some new plots are also proposed for design purpose to avoid the instability. The instability is found to be associated with large crossover frequency. A conservative stability condition, agreed with the past research, is derived. The effect of the voltage loop ripple on the instability is also analyzed.
- 12 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 61 (3) , 922-929
Asymmetric Instability Conditions for Peak and Valley Current Programmed Converters at Light Loading
Three types of bifurcations (instabilities) in the DC-DC converter under valley current mode control (VCMC) are analyzed, which is an extension of a recent paper on the peak current mode control (PCMC). The three bifurcations are border-collision, period-doubling, and saddle-node bifurcations. The corresponding critical (instability) conditions are derived. The derived conditions divide the parameter space into different operating modes. Contrary to the general belief that the critical conditions for VCMC and PCMC are symmetric with respect to the duty cycle D=1/2, most critical conditions are actually asymmetric. The dynamics symmetry is converter, bifurcation, loading, and parameter dependent, verified by bifurcation diagrams and time-domain simulations. The VCMC boost converter has rich dynamics and it is extensively analyzed.
- 12 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 61 (3) , 922-929
Asymmetric Instability Conditions for Peak and Valley Current Programmed Converters at Light Loading
Three types of bifurcations (instabilities) in the DC-DC converter under valley current mode control (VCMC) are analyzed, which is an extension of a recent paper on the peak current mode control (PCMC). The three bifurcations are border-collision, period-doubling, and saddle-node bifurcations. The corresponding critical (instability) conditions are derived. The derived conditions divide the parameter space into different operating modes. Contrary to the general belief that the critical conditions for VCMC and PCMC are symmetric with respect to the duty cycle D=1/2, most critical conditions are actually asymmetric. The dynamics symmetry is converter, bifurcation, loading, and parameter dependent, verified by bifurcation diagrams and time-domain simulations. The VCMC boost converter has rich dynamics and it is extensively analyzed.
- 1 December 2013
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 350 (10) , 3293-3312
Using Nyquist or Nyquist-like plot to predict three typical instabilities in DC–DC converters
- 1 December 2013
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 350 (10) , 3293-3312
Using Nyquist or Nyquist-like plot to predict three typical instabilities in DC–DC converters