Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marko Jankovec has a total of 149 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Degradation of Crystalline Si‐Based Solar Modules With Varying Material Combinations—Part I: Encapsulant Degradation

    by Robert Heidrich, Oscar Lacroix‐Andrivet, Nikola Babić, Lasse Baldauf, Julia Rendon, Marko Jankovec, Marko Topič, Camille Bainier, Anton Mordvinkin, Hervé Vezin, et al.

    This work is the first part of three studies dealing with the degradation of crystalline Si‐based solar modules depending on the chosen material combination, whereby the focus of this work is on encapsulant degradation. Within the paper, solar modules based on ethylene‐vinyl acetate (EVA) copolymer encapsulant and polyolefin elastomer (POE) encapsulant with different rear side encapsulations were artificially aged with UV irradiation (76.6 W/m 2 between 280 and 380 nm) in combination with 60% relative humidity at 85°C. In situ moisture measurements and simulations of oxygen diffusion were used to show how stressors are distributed in the module. Additive and polymer degradation was analyzed by the Fourier transform infrared spectroscopy (FTIR), Orbitrap mass spectrometry, and electron paramagnetic resonance (EPR). This approach made it possible to determine the degradation of the encapsulants in a spatially resolved manner depending on the presence of stressors and the consumption of additives. The findings reveal that degradation is heavily influenced by the microclimate within the module, which itself is affected by the material combinations used. It is shown that oxygen has a major influence on the degradation of POE, as it is essential for the formation of hydroperoxides. Furthermore, it becomes clear that EVA does not necessarily have to be inferior to the novel POE encapsulants if it is combined with the right rear side encapsulation.

  • Open Access

    Active Snubber Solution for an Interleaved Flyback Converter

    by Boštjan Glažar, Marko Jankovec

    This paper presents an energy-recovering active snubber in which the energy captured by the snubber capacitor is transferred back to the converter’s input using an auxiliary inverting switching stage. The snubber operates independently of the main power stage and can therefore be applied to a wide range of isolated converter topologies without modifying their primary control or structure. The proposed snubber achieves an energy-recovery efficiency of approximately 80%, thereby reducing snubber-related losses by the same proportion. As a representative implementation, the concept was experimentally validated in a 550 W dual-phase interleaved DC–DC flyback converter, where it improves the overall converter efficiency by 1.6 percentage points and reduces total losses by 18% compared with a dissipative snubber solution. The proposed snubber supports a wide input-voltage range and is well suited for multiphase converters, as most of its components can be shared between phases.

  • Open Access

    Improving IV Curve Measurement Accuracy of High-Efficiency PV Modules Using Extrapolation Based on a Dual Load Capacitor Scanning Method

    by Jonas Aleksander Oražem, Marko Topič, Marko Jankovec

    With continuous progress in photovoltaic (PV) technology, the conversion efficiency of commercial PV modules is steadily increasing well above 20 %, even exceeding 24 %. Such high-efficiency (HE) PV modules typically exhibit long free-carrier lifetimes, resulting in high diffusion capacitances. For routine field testing, technicians rely on fast, affordable and portable IV curve scanners, which typically employ the load capacitor scanning method. When applied to HE PV modules with high internal capacitance, this method frequently leads to IV curve distortion, resulting in a significant underestimation of the measured maximum power point (MPP). In this paper, we propose a novel extrapolation technique that corrects the distortion of the measured IV curve through two consecutive IV scans using two different load capacitors. The extrapolation algorithm uses a dynamic electrical model of the whole system, including the PV module and the measurement setup, to compensate for the effect of the PV module’s capacitance on the acquired IV curve shape. It extracts two free parameters related to series resistance and the lifetime of the minority carriers that give the best match between the two extrapolated IV curves. We validated the method on four different state-of-the-art HE PV modules (HIT, TOPCon, IBC, and PERC), reliably reducing the MPP error from the initial up to 4 % to less than 1 %.


  • Open Access

    Experimental Investigation of Interconnection Topologies for Vehicle-Integrated PV Array

    by Kamran S. Awan, Mohammed A. Elgendy, Žiga Miklič, Arslan Ali, Marko Jankovec

    Photovoltaic (PV) systems are increasingly popular because of decreasing prices and increasing efficiencies, enabling applications such as vehicle integrated photovoltaics (VIPVs) and building integrated photovoltaics (BIPVs). The performance of VIPVs is strongly affected by dynamic partial shading conditions due to vehicle movement in urban environments surrounded by buildings and trees. It is therefore important to develop technical solutions to optimize the performance of VIPVs by finding optimal electrical connections among cells to mitigate the shading effects and increase the power output. Building on previously published simulation analyses of Series-Parallel (SP), Total-Cross-Tied (TCT), Bridge Link (BL) and Honeycomb (HC) interconnection topologies, this paper presents a mathematical model and experimental comparative analysis using a PV array of 30 solar cells. The experiments are conducted using a flasher Spire Sun Simulator 5100 SLP emulating uniform solar irradiance under STC in addition to seven different partial shading scenarios. Experimental results show that the TCT interconnection outperforms the other interconnection schemes, delivering up to 21%, 8%, and 14% higher power output than SP, BL, and HC, respectively, under different shading scenarios. These results agree well with the simulation outcomes.


  • Open Access

    Tailoring nanoscale interfaces for perovskite–perovskite–silicon triple-junction solar cells

    by Jianghui Zheng, Guoliang Wang, Leiping Duan, Weiyuan Duan, Yang Jiang, Phoebe Pearce, Yijun Gao, Arafat Mahmud, Chwenhaw Liao, Tik Lun Leung, et al.

    Triple‐junction solar cells theoretically outperform their double-junction and single‐junction counterparts in power conversion efficiency, yet practical perovskite–perovskite–silicon devices have fallen short of both theoretical limits and commercial targets. To address surface defects in the top perovskite junction, we introduce a piperazine-1,4-diium chloride treatment, which replaces less stable lithium fluoride. For interfacing the top and middle perovskite junctions, we optimize the size of gold nanoparticles deposited on atomic layer-deposited tin oxide for best ohmic contacting with minimal optical losses. Applying these strategies, our champion 1-cm 2 triple‐junction cell achieved a third party-verified reverse‐scan power conversion efficiency of 27.06% with an open circuit voltage of 3.16 V. Scaling up to 16 cm 2 , the device produced a certified steady‐state power conversion efficiency of 23.3%. Device longevity also improved by eliminating methylammonium and incorporating rubidium into the perovskite bulk alongside the piperazine-1,4-diium chloride surface layer. An encapsulated 1-cm 2 cell retained 95% of its initial efficiency after 407 h at maximum power point and passed the IEC 61215 thermal cycling test. These results represent advancements towards efficient and stable perovskite–perovskite–silicon triple-junction solar cells.


  • Open Access

    Ultra-Low-Power Indoor Light Harvesting and Solar Cell Characterization System

    by Darjo Uršič, Matija Pirc, Marko Jošt, Marko Topič, Marko Jankovec

    In this study, we present a development of a solar-powered Internet-of-Things (IoT) device, that incorporates both light energy harvesting and solar cell monitoring, which we demonstrate by long term monitoring of a single perovskite solar cell in office-like indoor environment. Using off-the-shelf components we engineered a compact, self-sufficient IoT device, with a remarkable 75% efficient energy harvesting (EH) method, at input currents in a range of microamperes. The IoT device acquires environmental data (irradiance, temperature, humidity) and solar cell electrical parameters including its IV curve, which it sends over a Bluetooth low energy (BLE) connection to a nearby access point. A single lab-scale perovskite solar cell was used to evaluate the device in a real-world office setting, over a period of one year. Our findings demonstrate that employing a perovskite solar cell with a 1 cm 2 active area and a 1 F supercapacitor as a charge storage, meets the energy demands for the continuous operation of the developed IoT device at low irradiance conditions. Additionally, irradiance sensor data in combination with the full IV curve measurements of the solar cell are used to monitor the available energy and appropriately react to the environment and solar cell changes, while maintaining an extremely low average power consumption of 6 uW. At the same time, the acquired data provide a valuable information about the solar cell’s electrical behaviour, which makes the developed system an easy to use and versatile long-term monitoring device.


  • Open Access

    Monitoring solar irradiance and PV module performance in mobile applications

    by Marko Jankovec, Kristijan Brecl, Matevž Bokalič, Matija Pirc, Marko Topič


  • Open Access

    From Sunrise to Sunset: Unraveling Metastability in Perovskite Solar Cells by Coupled Outdoor Testing and Energy Yield Modelling

    by Marko Remec, Špela Tomšič, Mark Khenkin, Quiterie Emery, Jinzhao Li, Florian Scheler, Boštjan Glažar, Marko Jankovec, Marko Jošt, Eva Unger, et al.

    Perovskite‐based solar cells exhibit peculiar outdoor performance which is not yet fully understood. The results of outdoor tests may contain hidden, but valuable information that cannot be fully extracted from measurements alone. One such phenomenon is the effect of nighttime degradation and the subsequent light‐soaking recovery, which can take from a few hours in the morning up to the entire day. In this work, long‐term outdoor monitoring is combined with energy yield modeling to qualitatively and quantitatively investigate the effect of light‐soaking recovery in both single junction and tandem perovskite‐based devices. Following the novel methodology presented in this study, it is observed that the light‐soaking effect depends not only on the daily irradiation but also on the device temperature, and it can be described using a simple empirical formalism. Incorporating this dependency into the energy yield model results in an excellent agreement between the simulated and the measured outdoor data, which allows to perform long‐term prediction studies. The model estimates that the light‐soaking metastability effect decreases the attainable annual energy yield by up to ≈5% for the studied single junction devices, and for tandems by up to ≈3%, depending on the geographical location, and even more for non‐optimal device orientation.