Jonas Lussi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonas Lussi has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Bradley J. Nelson
Multi-Scale Robotics Lab, ETH Zurich, Zurich, Switzerland
4 shared publications - Quentin Boehler
Medical Robotics Lab ETH Zurich Zurich Switzerland
3 shared publications - Andrew J. Petruska
Colorado School of Mines, Golden, CO, USA
2 shared publications Bradley J Nelson
Multi-Scale Robotics Lab ETH Zürich Tannenstrasse 3 Zürich 8092 Switzerland
1 shared publicationBradley J. Nelson
Multi-Scale Robotics Lab, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland
1 shared publicationCarmela De Marco
Institute of Robotics and Intelligent Systems ETH Zurich Zurich CH‐8092 Switzerland
1 shared publication
Latest Publications
- Open Access
- 16 May 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (4) , 101842
In vitro renal artery stenting using a steerable guide wire navigated by a mobile electromagnetic field
- 16 May 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (4) , 101842
Open AccessIn vitro renal artery stenting using a steerable guide wire navigated by a mobile electromagnetic field
- Open Access
- 14 March 2024
- Published by Wiley in Advanced Science
- Vol. 11 (19) , e2400980
Autonomous Magnetic Navigation in Endoscopic Image Mosaics
Endoscopes navigate within the human body to observe anatomical structures with minimal invasiveness. A major shortcoming of their use is their narrow field‐of‐view during navigation in large, hollow anatomical regions. Mosaics of endoscopic images can provide surgeons with a map of the tool's environment. This would facilitate procedures, improve their efficiency, and potentially generate better patient outcomes. The emergence of magnetically steered endoscopes opens the way to safer procedures and creates an opportunity to provide robotic assistance both in the generation of the mosaic map and in navigation within this map. This paper proposes methods to autonomously navigate magnetic endoscopes to 1) generate endoscopic image mosaics and 2) use these mosaics as user interfaces to navigate throughout the explored area. These are the first strategies, which allow autonomous magnetic navigation in large, hollow organs during minimally invasive surgeries. The feasibility of these methods is demonstrated experimentally both in vitro and ex vivo in the context of the treatment of twin‐to‐twin transfusion syndrome. This minimally invasive procedure is performed in utero and necessitates coagulating shared vessels of twin fetuses on the placenta. A mosaic of the vasculature in combination with autonomous navigation has the potential to significantly facilitate this challenging surgery.
- 14 March 2024
- Published by Wiley in Advanced Science
- Vol. 11 (19) , e2400980
Open AccessAutonomous Magnetic Navigation in Endoscopic Image Mosaics
Endoscopes navigate within the human body to observe anatomical structures with minimal invasiveness. A major shortcoming of their use is their narrow field‐of‐view during navigation in large, hollow anatomical regions. Mosaics of endoscopic images can provide surgeons with a map of the tool's environment. This would facilitate procedures, improve their efficiency, and potentially generate better patient outcomes. The emergence of magnetically steered endoscopes opens the way to safer procedures and creates an opportunity to provide robotic assistance both in the generation of the mosaic map and in navigation within this map. This paper proposes methods to autonomously navigate magnetic endoscopes to 1) generate endoscopic image mosaics and 2) use these mosaics as user interfaces to navigate throughout the explored area. These are the first strategies, which allow autonomous magnetic navigation in large, hollow organs during minimally invasive surgeries. The feasibility of these methods is demonstrated experimentally both in vitro and ex vivo in the context of the treatment of twin‐to‐twin transfusion syndrome. This minimally invasive procedure is performed in utero and necessitates coagulating shared vessels of twin fetuses on the placenta. A mosaic of the vasculature in combination with autonomous navigation has the potential to significantly facilitate this challenging surgery.
- Top Cited Papers
- 14 February 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 9 (87) , eadh0298
Dexterous helical magnetic robot for improved endovascular access
Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician’s skill and the device’s ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device’s surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig.
- 14 February 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 9 (87) , eadh0298
Top Cited PapersDexterous helical magnetic robot for improved endovascular access
Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician’s skill and the device’s ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device’s surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig.
- Open Access
- 13 October 2022
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (11)
Magnetically Guided Laser Surgery for the Treatment of Twin‐to‐Twin Transfusion Syndrome
Twin‐to‐twin transfusion syndrome (TTTS) is a severe disorder that often leads to the death of monochorionic twin fetuses, if left untreated. Current prenatal interventions to treat the condition involve the use of rigid fetoscopes for targeted laser coagulation of the vascular anastomoses. These tools are limited in their area of operation, making treatment challenging, especially in cases with anterior placentation. Herein, a robotic platform to perform this task using remote magnetic navigation is proposed. In contrast to rigid tools, the presented custom magnetic fetoscope is highly flexible, dexterous, and has considerable advantages, including safety and precision. A visual servoing algorithm that allows the surgeon to navigate in the uterus with submillimeter precision is introduced. The system has been validated on ex vivo human placentas in a setting that mimics the real intraoperative conditions.
- 13 October 2022
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (11)
Open AccessMagnetically Guided Laser Surgery for the Treatment of Twin‐to‐Twin Transfusion Syndrome
Twin‐to‐twin transfusion syndrome (TTTS) is a severe disorder that often leads to the death of monochorionic twin fetuses, if left untreated. Current prenatal interventions to treat the condition involve the use of rigid fetoscopes for targeted laser coagulation of the vascular anastomoses. These tools are limited in their area of operation, making treatment challenging, especially in cases with anterior placentation. Herein, a robotic platform to perform this task using remote magnetic navigation is proposed. In contrast to rigid tools, the presented custom magnetic fetoscope is highly flexible, dexterous, and has considerable advantages, including safety and precision. A visual servoing algorithm that allows the surgeon to navigate in the uterus with submillimeter precision is introduced. The system has been validated on ex vivo human placentas in a setting that mimics the real intraoperative conditions.
- Open Access
- 17 July 2021
- Published by Wiley in Advanced Science
- Vol. 8 (18) , 2101290
A Submillimeter Continuous Variable Stiffness Catheter for Compliance Control
Minimally invasive robotic surgery often requires functional tools that can change their compliance to adapt to the environment and surgical needs. This paper proposes a submillimeter continuous variable stiffness catheter equipped with a phase‐change alloy that has a high stiffness variation in its different states, allowing for rapid compliance control. Variable stiffness is achieved through a variable phase boundary in the alloy due to a controlled radial temperature gradient. This catheter can be safely navigated in its soft state and rigidified to the required stiffness during operation to apply a desired force at the tip. The maximal contact force that the catheter applies to tissue can be continuously modified by a factor of 400 (≈20 mN–8 N). The catheter is equipped with a magnet and a micro‐gripper to perform a fully robotic ophthalmic minimally invasive surgery on an eye phantom by means of an electromagnetic navigation system.
- 17 July 2021
- Published by Wiley in Advanced Science
- Vol. 8 (18) , 2101290
Open AccessA Submillimeter Continuous Variable Stiffness Catheter for Compliance Control
Minimally invasive robotic surgery often requires functional tools that can change their compliance to adapt to the environment and surgical needs. This paper proposes a submillimeter continuous variable stiffness catheter equipped with a phase‐change alloy that has a high stiffness variation in its different states, allowing for rapid compliance control. Variable stiffness is achieved through a variable phase boundary in the alloy due to a controlled radial temperature gradient. This catheter can be safely navigated in its soft state and rigidified to the required stiffness during operation to apply a desired force at the tip. The maximal contact force that the catheter applies to tissue can be continuously modified by a factor of 400 (≈20 mN–8 N). The catheter is equipped with a magnet and a micro‐gripper to perform a fully robotic ophthalmic minimally invasive surgery on an eye phantom by means of an electromagnetic navigation system.
- 8 February 2018
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 03 (01)
A Robotic Diathermy System for Automated Capsulotomy
- 8 February 2018
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 03 (01)
A Robotic Diathermy System for Automated Capsulotomy
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 347-354
Perforation forces of the intact porcine anterior lens capsule
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 347-354
Perforation forces of the intact porcine anterior lens capsule