JLJonas Lussi

Jonas Lussi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonas Lussi has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vitro renal artery stenting using a steerable guide wire navigated by a mobile electromagnetic field

    by Christian Zielasek, Jonas Lussi, Silvia Viviani, Vladimir Makaloski, Drosos Kotelis, Silvan Jungi


  • Open Access

    Autonomous Magnetic Navigation in Endoscopic Image Mosaics

    by Michelle Mattille, Quentin Boehler, Jonas Lussi, Nicole Ochsenbein, Ueli Moehrlen, Bradley J. Nelson

    Endoscopes navigate within the human body to observe anatomical structures with minimal invasiveness. A major shortcoming of their use is their narrow field‐of‐view during navigation in large, hollow anatomical regions. Mosaics of endoscopic images can provide surgeons with a map of the tool's environment. This would facilitate procedures, improve their efficiency, and potentially generate better patient outcomes. The emergence of magnetically steered endoscopes opens the way to safer procedures and creates an opportunity to provide robotic assistance both in the generation of the mosaic map and in navigation within this map. This paper proposes methods to autonomously navigate magnetic endoscopes to 1) generate endoscopic image mosaics and 2) use these mosaics as user interfaces to navigate throughout the explored area. These are the first strategies, which allow autonomous magnetic navigation in large, hollow organs during minimally invasive surgeries. The feasibility of these methods is demonstrated experimentally both in vitro and ex vivo in the context of the treatment of twin‐to‐twin transfusion syndrome. This minimally invasive procedure is performed in utero and necessitates coagulating shared vessels of twin fetuses on the placenta. A mosaic of the vasculature in combination with autonomous navigation has the potential to significantly facilitate this challenging surgery.


  • Top Cited Papers

    Dexterous helical magnetic robot for improved endovascular access

    by R. Dreyfus, Q. Boehler, S. Lyttle, P. Gruber, J. Lussi, C. Chautems, S. Gervasoni, J. Berberat, D. Seibold, N. Ochsenbein-Kölble, et al.

    Treating vascular diseases in the brain requires access to the affected region inside the body. This is usually accomplished through a minimally invasive technique that involves the use of long, thin devices, such as wires and tubes, that are manually maneuvered by a clinician within the bloodstream. By pushing, pulling, and twisting, these devices are navigated through the tortuous pathways of the blood vessels. The outcome of the procedure heavily relies on the clinician’s skill and the device’s ability to navigate to the affected target region in the bloodstream, which is often inhibited by tortuous blood vessels. Sharp turns require high flexibility, but this flexibility inhibits translation of proximal insertion to distal tip advancement. We present a highly dexterous, magnetically steered continuum robot that overcomes pushability limitations through rotation. A helical protrusion on the device’s surface engages with the vessel wall and translates rotation to forward motion at every point of contact. An articulating magnetic tip allows for active steerability, enabling navigation from the aortic arch to millimeter-sized arteries of the brain. The effectiveness of the magnetic continuum robot has been demonstrated through successful navigation in models of the human vasculature and in blood vessels of a live pig.


  • Open Access

    Magnetically Guided Laser Surgery for the Treatment of Twin‐to‐Twin Transfusion Syndrome

    by Jonas Lussi, Simone Gervasoni, Michelle Mattille, Roland Dreyfus, Quentin Boehler, Michael Reinehr, Nicole Ochsenbein, Bradley J Nelson, Ueli Moehrlen

    Twin‐to‐twin transfusion syndrome (TTTS) is a severe disorder that often leads to the death of monochorionic twin fetuses, if left untreated. Current prenatal interventions to treat the condition involve the use of rigid fetoscopes for targeted laser coagulation of the vascular anastomoses. These tools are limited in their area of operation, making treatment challenging, especially in cases with anterior placentation. Herein, a robotic platform to perform this task using remote magnetic navigation is proposed. In contrast to rigid tools, the presented custom magnetic fetoscope is highly flexible, dexterous, and has considerable advantages, including safety and precision. A visual servoing algorithm that allows the surgeon to navigate in the uterus with submillimeter precision is introduced. The system has been validated on ex vivo human placentas in a setting that mimics the real intraoperative conditions.


  • Open Access

    A Submillimeter Continuous Variable Stiffness Catheter for Compliance Control

    by Jonas Lussi, Michael Mattmann, Semih Sevim, Fabian Grigis, Carmela De Marco, Christophe Chautems, Salvador Pané, Josep Puigmartí‐Luis, Quentin Boehler, Bradley J. Nelson

    Minimally invasive robotic surgery often requires functional tools that can change their compliance to adapt to the environment and surgical needs. This paper proposes a submillimeter continuous variable stiffness catheter equipped with a phase‐change alloy that has a high stiffness variation in its different states, allowing for rapid compliance control. Variable stiffness is achieved through a variable phase boundary in the alloy due to a controlled radial temperature gradient. This catheter can be safely navigated in its soft state and rigidified to the required stiffness during operation to apply a desired force at the tip. The maximal contact force that the catheter applies to tissue can be continuously modified by a factor of 400 (≈20 mN–8 N). The catheter is equipped with a magnet and a micro‐gripper to perform a fully robotic ophthalmic minimally invasive surgery on an eye phantom by means of an electromagnetic navigation system.


  • A Robotic Diathermy System for Automated Capsulotomy

    by Franziska Ullrich, Jonas Lussi, Vasileios Chatzopoulos, Stephan Michels, Andrew J. Petruska, Bradley J. Nelson


  • Perforation forces of the intact porcine anterior lens capsule

    by Franziska Ullrich, Jonas Lussi, Dimitrios Felekis, Stephan Michels, Andrew J. Petruska, Bradley J. Nelson