Morteza Zabihi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Morteza Zabihi has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Moncef Gabbouj
Faculty of Information Technology and Communication Sciences, Tampere University, Tampere, Finland
6 shared publications Serkan Kiranyaz
Electrical Engineering Department Qatar University Doha Qatar
5 shared publications- Turker Ince
Faculty of Engineering, German International University, 13507 Berlin, Germany
4 shared publications Emily J. Gilmore
Department of Neurology, Yale Medical School, New Haven, CT, USA
3 shared publicationsAggelos K. Katsaggelos
2 shared publications- Ali Bahrami Rad
Emory University School of Medicine
2 shared publications
Latest Publications
- 30 April 2026
- Published by Elsevier in Clinical Neurophysiology
- Vol. 188, 2111899
Resting-state EEG for continuous prognostic monitoring and prediction of coma recovery after acute brain injury
- 30 April 2026
- Published by Elsevier in Clinical Neurophysiology
- Vol. 188, 2111899
Resting-state EEG for continuous prognostic monitoring and prediction of coma recovery after acute brain injury
- Open Access
- 27 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
A transparent AI assurance and benchmarking framework for EEG seizure detection on TUSZ seeded with a reproducible gradient-boosting ensemble
Reliable evaluation is essential for clinically usable automated electroencephalography (EEG) seizure detection. Although the TUH EEG Seizure Corpus (TUSZ) is the de facto benchmark, studies often use non-canonical splits, mix patients across partitions, or evaluate on seizure-only segments, making results hard to compare. We release an open-source, transparent benchmark for offline binary seizure detection on TUSZ v2.0.3 that strictly follows the official Train/Dev/Eval partition and evaluates in continuous EEG. Each 60-s window (15-s stride) is mapped to expert features and classified by three CatBoost ensembles: a within-window base model and two temporal-context models (full and high-sensitivity). We cast operating-point selection as an alarm-budget decision problem: on the Development set, we jointly choose the score threshold and event post-processing to maximize event sensitivity while enforcing specificity ≥ 0.93 and false alarms ≤ 0.69 per hour, then freeze this decision policy and apply it once to the held-out Eval set. On Eval, we obtain AUROC 0.92 and balanced accuracy 0.83 at the window level and event sensitivity 0.75 at 0.68 false alarms/hour (time-based positive predictive value [PPV] 0.57; recall 0.76). We provide the protocol and results as a reproducible baseline and clinically oriented benchmark for comparing past and future models.
- 27 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessA transparent AI assurance and benchmarking framework for EEG seizure detection on TUSZ seeded with a reproducible gradient-boosting ensemble
Reliable evaluation is essential for clinically usable automated electroencephalography (EEG) seizure detection. Although the TUH EEG Seizure Corpus (TUSZ) is the de facto benchmark, studies often use non-canonical splits, mix patients across partitions, or evaluate on seizure-only segments, making results hard to compare. We release an open-source, transparent benchmark for offline binary seizure detection on TUSZ v2.0.3 that strictly follows the official Train/Dev/Eval partition and evaluates in continuous EEG. Each 60-s window (15-s stride) is mapped to expert features and classified by three CatBoost ensembles: a within-window base model and two temporal-context models (full and high-sensitivity). We cast operating-point selection as an alarm-budget decision problem: on the Development set, we jointly choose the score threshold and event post-processing to maximize event sensitivity while enforcing specificity ≥ 0.93 and false alarms ≤ 0.69 per hour, then freeze this decision policy and apply it once to the held-out Eval set. On Eval, we obtain AUROC 0.92 and balanced accuracy 0.83 at the window level and event sensitivity 0.75 at 0.68 false alarms/hour (time-based positive predictive value [PPV] 0.57; recall 0.76). We provide the protocol and results as a reproducible baseline and clinically oriented benchmark for comparing past and future models.
- Open Access
- 16 July 2024
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 6 (7) , e1118
Deriving Automated Device Metadata From Intracranial Pressure Waveforms: A Transforming Research and Clinical Knowledge in Traumatic Brain Injury ICU Physiology Cohort Analysis
IMPORTANCE: Treatment for intracranial pressure (ICP) has been increasingly informed by machine learning (ML)-derived ICP waveform characteristics. There are gaps, however, in understanding how ICP monitor type may bias waveform characteristics used for these predictive tools since differences between external ventricular drain (EVD) and intraparenchymal monitor (IPM)-derived waveforms have not been well accounted for. OBJECTIVES: We sought to develop a proof-of-concept ML model differentiating ICP waveforms originating from an EVD or IPM. DESIGN, SETTING, AND PARTICIPANTS: We examined raw ICP waveform data from the ICU physiology cohort within the prospective Transforming Research and Clinical Knowledge in Traumatic Brain Injury multicenter study. MAIN OUTCOMES AND MEASURES: Nested patient-wise five-fold cross-validation and group analysis with bagged decision trees (BDT) and linear discriminant analysis were used for feature selection and fair evaluation. Nine patients were kept as unseen hold-outs for further evaluation. RESULTS: ICP waveform data totaling 14,110 hours were included from 82 patients (EVD, 47; IPM, 26; both, 9). Mean age, Glasgow Coma Scale (GCS) total, and GCS motor score upon admission, as well as the presence and amount of midline shift, were similar between groups. The model mean area under the receiver operating characteristic curve (AU-ROC) exceeded 0.874 across all folds. In additional rigorous cluster-based subgroup analysis, targeted at testing the resilience of models to cross-validation with smaller subsets constructed to develop models in one confounder set and test them in another subset, AU-ROC exceeded 0.811. In a similar analysis using propensity score-based rather than cluster-based subgroup analysis, the mean AU-ROC exceeded 0.827. Of 842 extracted ICP features, 62 were invariant within every analysis, representing the most accurate and robust differences between ICP monitor types. For the nine patient hold-outs, an AU-ROC of 0.826 was obtained using BDT. CONCLUSIONS AND RELEVANCE: The developed proof-of-concept ML model identified differences in EVD- and IPM-derived ICP signals, which can provide missing contextual data for large-scale retrospective datasets, prevent bias in computational models that ingest ICP data indiscriminately, and control for confounding using our model’s output as a propensity score by to adjust for the monitoring method that was clinically indicated. Furthermore, the invariant features may be leveraged as ICP features for anomaly detection.
- 16 July 2024
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 6 (7) , e1118
Open AccessDeriving Automated Device Metadata From Intracranial Pressure Waveforms: A Transforming Research and Clinical Knowledge in Traumatic Brain Injury ICU Physiology Cohort Analysis
IMPORTANCE: Treatment for intracranial pressure (ICP) has been increasingly informed by machine learning (ML)-derived ICP waveform characteristics. There are gaps, however, in understanding how ICP monitor type may bias waveform characteristics used for these predictive tools since differences between external ventricular drain (EVD) and intraparenchymal monitor (IPM)-derived waveforms have not been well accounted for. OBJECTIVES: We sought to develop a proof-of-concept ML model differentiating ICP waveforms originating from an EVD or IPM. DESIGN, SETTING, AND PARTICIPANTS: We examined raw ICP waveform data from the ICU physiology cohort within the prospective Transforming Research and Clinical Knowledge in Traumatic Brain Injury multicenter study. MAIN OUTCOMES AND MEASURES: Nested patient-wise five-fold cross-validation and group analysis with bagged decision trees (BDT) and linear discriminant analysis were used for feature selection and fair evaluation. Nine patients were kept as unseen hold-outs for further evaluation. RESULTS: ICP waveform data totaling 14,110 hours were included from 82 patients (EVD, 47; IPM, 26; both, 9). Mean age, Glasgow Coma Scale (GCS) total, and GCS motor score upon admission, as well as the presence and amount of midline shift, were similar between groups. The model mean area under the receiver operating characteristic curve (AU-ROC) exceeded 0.874 across all folds. In additional rigorous cluster-based subgroup analysis, targeted at testing the resilience of models to cross-validation with smaller subsets constructed to develop models in one confounder set and test them in another subset, AU-ROC exceeded 0.811. In a similar analysis using propensity score-based rather than cluster-based subgroup analysis, the mean AU-ROC exceeded 0.827. Of 842 extracted ICP features, 62 were invariant within every analysis, representing the most accurate and robust differences between ICP monitor types. For the nine patient hold-outs, an AU-ROC of 0.826 was obtained using BDT. CONCLUSIONS AND RELEVANCE: The developed proof-of-concept ML model identified differences in EVD- and IPM-derived ICP signals, which can provide missing contextual data for large-scale retrospective datasets, prevent bias in computational models that ingest ICP data indiscriminately, and control for confounding using our model’s output as a propensity score by to adjust for the monitoring method that was clinically indicated. Furthermore, the invariant features may be leveraged as ICP features for anomaly detection.
- Open Access
Resting-State Electroencephalography for Continuous, Passive Prediction of Coma Recovery After Acute Brain Injury
Accurately predicting emergence from disorders of consciousness (DoC) after acute brain injury can profoundly influence mortality, acute management, and rehabilitation planning. While recent advances in functional neuroimaging and stimulus-based EEG offer the potential to enrich shared decision-making, their procedural sophistication and expense limit widespread availability or repeated performance. We investigated continuous EEG (cEEG) within a passive, “resting-state” framework to provide continuously updated predictions of DoC recovery at 24-, 48-, and 72-hour prediction horizons. To develop robust, continuous prediction models from a large population of patients with acute brain injury (ABI), we leveraged a recently described pragmatic approach transforming Glasgow Coma Scale assessment sub-score combinations into frequently assessed DoC diagnoses: coma, vegetative state, minimally conscious state with or without language, and post-injury confusional or recovered states. We retrospectively identified consecutive patients undergoing cEEG following acute traumatic brain injury (TBI), subarachnoid hemorrhage (SAH), or intracerebral hemorrhage (ICH). Models continuously predicting DoC diagnosis for multiple prediction horizons were evaluated utilizing recent clinical assessments with or without cEEG information, which comprised a comprehensive EEG feature set of 288 time, frequency, and time-frequency characteristics computed from consecutive 5-minute EEG epochs, with 6 additional features capturing each EEG feature’s temporal dynamics. Features were fed into a predictive model developed with cross-validation; the ordinal DoC diagnosis was discriminated using an ensemble of XGBoost binary classifiers. For 201 ABI patients (46 TBI, 140 SAH, 15 ICH patients comprising 27,280 cEEG-hours with concomitant clinical assessments), cEEG-augmented models accurately predicted the future DoC diagnosis at 24 hours (one-vs-rest AU-ROC, 92.4%; weighted-F1 84.1%), 48 hours (one-vs-rest AU-ROC=88%, weighted-F1=80%) and 72 hours (one-vs-rest AU-ROC=86.3%, weighted-F1=76.6%). Models were robust to utilizing different ordinal cut-points for the DoC prediction target and evaluating additional models derived from specific sub-populations using a confound-isolating cross-validation framework. The most robust features across evaluation configurations included Petrosian fractal dimension, relative power of high to low (gamma-beta to delta-alpha) EEG frequency spectra, energy within the 12-35 Hz frequency band in the short-time Fourier transform domain, and wavelet entropy. The cEEG-augmented model exceeded the performance of models using preceding clinical assessments, continuously predicting future DoC diagnosis with one-vs-rest AU-ROC in the range of 84.3-92.4% while utilizing approaches to limit overfitting. The proposed continuous, resting-state cEEG prediction method represents a promising tool to predict DoC emergence in ABI patients. Enabling these methods prospectively would represent a new paradigm of continuous prognostic monitoring for predicting coma recovery and assessing treatment response.
Open AccessResting-State Electroencephalography for Continuous, Passive Prediction of Coma Recovery After Acute Brain Injury
Accurately predicting emergence from disorders of consciousness (DoC) after acute brain injury can profoundly influence mortality, acute management, and rehabilitation planning. While recent advances in functional neuroimaging and stimulus-based EEG offer the potential to enrich shared decision-making, their procedural sophistication and expense limit widespread availability or repeated performance. We investigated continuous EEG (cEEG) within a passive, “resting-state” framework to provide continuously updated predictions of DoC recovery at 24-, 48-, and 72-hour prediction horizons. To develop robust, continuous prediction models from a large population of patients with acute brain injury (ABI), we leveraged a recently described pragmatic approach transforming Glasgow Coma Scale assessment sub-score combinations into frequently assessed DoC diagnoses: coma, vegetative state, minimally conscious state with or without language, and post-injury confusional or recovered states. We retrospectively identified consecutive patients undergoing cEEG following acute traumatic brain injury (TBI), subarachnoid hemorrhage (SAH), or intracerebral hemorrhage (ICH). Models continuously predicting DoC diagnosis for multiple prediction horizons were evaluated utilizing recent clinical assessments with or without cEEG information, which comprised a comprehensive EEG feature set of 288 time, frequency, and time-frequency characteristics computed from consecutive 5-minute EEG epochs, with 6 additional features capturing each EEG feature’s temporal dynamics. Features were fed into a predictive model developed with cross-validation; the ordinal DoC diagnosis was discriminated using an ensemble of XGBoost binary classifiers. For 201 ABI patients (46 TBI, 140 SAH, 15 ICH patients comprising 27,280 cEEG-hours with concomitant clinical assessments), cEEG-augmented models accurately predicted the future DoC diagnosis at 24 hours (one-vs-rest AU-ROC, 92.4%; weighted-F1 84.1%), 48 hours (one-vs-rest AU-ROC=88%, weighted-F1=80%) and 72 hours (one-vs-rest AU-ROC=86.3%, weighted-F1=76.6%). Models were robust to utilizing different ordinal cut-points for the DoC prediction target and evaluating additional models derived from specific sub-populations using a confound-isolating cross-validation framework. The most robust features across evaluation configurations included Petrosian fractal dimension, relative power of high to low (gamma-beta to delta-alpha) EEG frequency spectra, energy within the 12-35 Hz frequency band in the short-time Fourier transform domain, and wavelet entropy. The cEEG-augmented model exceeded the performance of models using preceding clinical assessments, continuously predicting future DoC diagnosis with one-vs-rest AU-ROC in the range of 84.3-92.4% while utilizing approaches to limit overfitting. The proposed continuous, resting-state cEEG prediction method represents a promising tool to predict DoC emergence in ABI patients. Enabling these methods prospectively would represent a new paradigm of continuous prognostic monitoring for predicting coma recovery and assessing treatment response.
- Open Access
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 210301-210317
Left Ventricular Wall Motion Estimation by Active Polynomials for Acute Myocardial Infarction Detection
Echocardiogram (echo) is the earliest and the primary tool for identifying regional wall motion abnormalities (RWMA) in order to diagnose myocardial infarction (MI) or commonly known as heart attack. This paper proposes a novel approach, Active Polynomial, which can accurately and robustly estimate the global motion of the Left Ventricular (LV) wall from any echo in a robust and accurate way. The proposed algorithm quantifies the true wall motion occurring in LV wall segments so as to assist cardiologists diagnose early signs of an acute MI. It further enables medical experts to gain an enhanced visualization capability of echo images through color-coded segments along with their “maximum motion displacement“ plots helping them to better assess wall motion and LV Ejection-Fraction (LVEF). The outputs of the method can further help echo-technicians to assess and improve the quality of the echocardiogram recording. A major contribution of this study is the first public echo database collection composed by physicians at the Hamad Medical Corporation Hospital in Qatar. The so-called HMC-QU database will serve as the benchmark for the forthcoming relevant studies. The results over HMC-QU dataset show that the proposed approach can achieve 87.94% accuracy, 92.86% sensitivity and 87.64% precision in MI detection even though the echo quality is quite poor and the temporal resolution is low.
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 210301-210317
Open AccessLeft Ventricular Wall Motion Estimation by Active Polynomials for Acute Myocardial Infarction Detection
Echocardiogram (echo) is the earliest and the primary tool for identifying regional wall motion abnormalities (RWMA) in order to diagnose myocardial infarction (MI) or commonly known as heart attack. This paper proposes a novel approach, Active Polynomial, which can accurately and robustly estimate the global motion of the Left Ventricular (LV) wall from any echo in a robust and accurate way. The proposed algorithm quantifies the true wall motion occurring in LV wall segments so as to assist cardiologists diagnose early signs of an acute MI. It further enables medical experts to gain an enhanced visualization capability of echo images through color-coded segments along with their “maximum motion displacement“ plots helping them to better assess wall motion and LV Ejection-Fraction (LVEF). The outputs of the method can further help echo-technicians to assess and improve the quality of the echocardiogram recording. A major contribution of this study is the first public echo database collection composed by physicians at the Hamad Medical Corporation Hospital in Qatar. The so-called HMC-QU database will serve as the benchmark for the forthcoming relevant studies. The results over HMC-QU dataset show that the proposed approach can achieve 87.94% accuracy, 92.86% sensitivity and 87.64% precision in MI detection even though the echo quality is quite poor and the temporal resolution is low.
- 27 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (2) , 543-555
Patient-Specific Seizure Detection Using Nonlinear Dynamics and Nullclines
Nonlinear dynamics has recently been extensively used to study epilepsy due to the complex nature of the neuronal systems. This study presents a novel method that characterizes the dynamic behavior of pediatric seizure events and introduces a systematic approach to locate the nullclines on the phase space when the governing differential equations are unknown. Nullclines represent the locus of points in the solution space where the components of the velocity vectors are zero. A simulation study over 5 benchmark nonlinear systems with well-known differential equations in 3D exhibits the characterization efficiency and accuracy of the proposed approach that is solely based on the reconstructed solution trajectory. Due to their unique characteristics in the nonlinear dynamics of epilepsy, discriminative features can be extracted based on the nullclines concept. Using a limited training data (only 25% of each EEG record) in order to mimic the real-world clinical practice, the proposed approach achieves 91.15% average sensitivity and 95.16% average specificity over the benchmark CHB-MIT dataset. Together with an elegant computational efficiency, the proposed approach can, therefore, be an automatic and reliable solution for patient-specific seizure detection in long EEG recordings.
- 27 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (2) , 543-555
Patient-Specific Seizure Detection Using Nonlinear Dynamics and Nullclines
Nonlinear dynamics has recently been extensively used to study epilepsy due to the complex nature of the neuronal systems. This study presents a novel method that characterizes the dynamic behavior of pediatric seizure events and introduces a systematic approach to locate the nullclines on the phase space when the governing differential equations are unknown. Nullclines represent the locus of points in the solution space where the components of the velocity vectors are zero. A simulation study over 5 benchmark nonlinear systems with well-known differential equations in 3D exhibits the characterization efficiency and accuracy of the proposed approach that is solely based on the reconstructed solution trajectory. Due to their unique characteristics in the nonlinear dynamics of epilepsy, discriminative features can be extracted based on the nullclines concept. Using a limited training data (only 25% of each EEG record) in order to mimic the real-world clinical practice, the proposed approach achieves 91.15% average sensitivity and 95.16% average specificity over the benchmark CHB-MIT dataset. Together with an elegant computational efficiency, the proposed approach can, therefore, be an automatic and reliable solution for patient-specific seizure detection in long EEG recordings.
- Open Access
1D Convolutional Neural Network Models for Sleep Arousal Detection
Sleep arousals transition the depth of sleep to a more superficial stage. The occurrence of such events is often considered as a protective mechanism to alert the body of harmful stimuli. Thus, accurate sleep arousal detection can lead to an enhanced understanding of the underlying causes and influencing the assessment of sleep quality. Previous studies and guidelines have suggested that sleep arousals are linked mainly to abrupt frequency shifts in EEG signals, but the proposed rules are shown to be insufficient for a comprehensive characterization of arousals. This study investigates the application of five recent convolutional neural networks (CNNs) for sleep arousal detection and performs comparative evaluations to determine the best model for this task. The investigated state-of-the-art CNN models have originally been designed for image or speech processing. A detailed set of evaluations is performed on the benchmark dataset provided by PhysioNet/Computing in Cardiology Challenge 2018, and the results show that the best 1D CNN model has achieved an average of 0.31 and 0.84 for the area under the precision-recall and area under the ROC curves, respectively.
Open Access1D Convolutional Neural Network Models for Sleep Arousal Detection
Sleep arousals transition the depth of sleep to a more superficial stage. The occurrence of such events is often considered as a protective mechanism to alert the body of harmful stimuli. Thus, accurate sleep arousal detection can lead to an enhanced understanding of the underlying causes and influencing the assessment of sleep quality. Previous studies and guidelines have suggested that sleep arousals are linked mainly to abrupt frequency shifts in EEG signals, but the proposed rules are shown to be insufficient for a comprehensive characterization of arousals. This study investigates the application of five recent convolutional neural networks (CNNs) for sleep arousal detection and performs comparative evaluations to determine the best model for this task. The investigated state-of-the-art CNN models have originally been designed for image or speech processing. A detailed set of evaluations is performed on the benchmark dataset provided by PhysioNet/Computing in Cardiology Challenge 2018, and the results show that the best 1D CNN model has achieved an average of 0.31 and 0.84 for the area under the precision-recall and area under the ROC curves, respectively.
- 13 June 2017
- Published by Springer Nature
- p. 551-554
Learned vs. Hand-Designed Features for ECG Beat Classification: A Comprehensive Study
- 13 June 2017
- Published by Springer Nature
- p. 551-554
Learned vs. Hand-Designed Features for ECG Beat Classification: A Comprehensive Study
- 18 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 24 (3) , 386-398
Analysis of High-Dimensional Phase Space via Poincaré Section for Patient-Specific Seizure Detection
In this paper, the performance of the phase space representation in interpreting the underlying dynamics of epileptic seizures is investigated and a novel patient-specific seizure detection approach is proposed based on the dynamics of EEG signals. To accomplish this, the trajectories of seizure and nonseizure segments are reconstructed in a high dimensional space using time-delay embedding method. Afterwards, Principal Component Analysis (PCA) was used in order to reduce the dimension of the reconstructed phase spaces. The geometry of the trajectories in the lower dimensions is then characterized using Poincaré section and seven features were extracted from the obtained intersection sequence. Once the features are formed, they are fed into a two-layer classification scheme, comprising the Linear Discriminant Analysis (LDA) and Naive Bayesian classifiers. The performance of the proposed method is then evaluated over the CHB-MIT benchmark database and the proposed approach achieved 88.27% sensitivity and 93.21% specificity on average with 25% training data. Finally, we perform comparative performance evaluations against the state-of-the-art methods in this domain which demonstrate the superiority of the proposed method.
- 18 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 24 (3) , 386-398
Analysis of High-Dimensional Phase Space via Poincaré Section for Patient-Specific Seizure Detection
In this paper, the performance of the phase space representation in interpreting the underlying dynamics of epileptic seizures is investigated and a novel patient-specific seizure detection approach is proposed based on the dynamics of EEG signals. To accomplish this, the trajectories of seizure and nonseizure segments are reconstructed in a high dimensional space using time-delay embedding method. Afterwards, Principal Component Analysis (PCA) was used in order to reduce the dimension of the reconstructed phase spaces. The geometry of the trajectories in the lower dimensions is then characterized using Poincaré section and seven features were extracted from the obtained intersection sequence. Once the features are formed, they are fed into a two-layer classification scheme, comprising the Linear Discriminant Analysis (LDA) and Naive Bayesian classifiers. The performance of the proposed method is then evaluated over the CHB-MIT benchmark database and the proposed approach achieved 88.27% sensitivity and 93.21% specificity on average with 25% training data. Finally, we perform comparative performance evaluations against the state-of-the-art methods in this domain which demonstrate the superiority of the proposed method.