JTJohanna Tapias-Rivera

Johanna Tapias-Rivera

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Johanna Tapias-Rivera has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of sea surface temperature in El Niño regions on dengue dynamics in Colombia: Evidence from causal machine learning

    by Juan David Gutiérrez, Johanna Tapias-Rivera, Martha Liliana Hijuelos-Cárdenas, Ludivia Esther Montaño-Villalba

    Dengue fever is among the most rapidly expanding vector-borne diseases globally, with Colombia ranking among the most affected countries in the Americas. Although previous research has linked climate variability and El Niño–Southern Oscillation (ENSO) episodes to dengue dynamics, the direct causal effect of sea surface temperature (SST) in El Niño regions remains insufficiently explored. We conducted a retrospective ecological analysis using monthly laboratory-confirmed dengue cases from 1,044 Colombian municipalities (2013–2023), combined with atmospheric, oceanic, and socioeconomic data. We emulated an experimental design to estimate the effect of SST in El Niño regions 1–2, 3, 3–4, and 4 on excess dengue cases. Confounder adjustment was guided by a Directed Acyclic Graph (DAG), and causal effects were estimated using Double Machine Learning (DML) with XGBoost learners. We estimated the Average Treatment Effect (ATE) and the Conditional Average Treatment Effect (CATE) conditioned on altitude. Robustness was evaluated with refutation tests introducing random confounders, subset replacement, and placebo exposures. A total of 455,329 confirmed dengue cases were reported during the study period, peaking in 2023. The strongest association was observed for El Niño region 3, where a standard deviation increase in SST (1.24 °C) raised the probability of excess dengue cases by 6.9 percentage points (ATE = 0.069, 95% CI = 0.056 – 0.083). El Niño regions 3–4 and 4 showed slightly weaker ATE yet significant effects (6.4% and 6.2%), while El Niño region 1–2 had the lowest effect (4.6%). The CATE analysis revealed that the effects of El Niño regions 1–2 and 3 were stronger at higher altitudes; meanwhile, for El Niño regions 3–4 and 4, the effects showed a slightly negative trend, suggesting a heterogeneous effect of El Niño regions on dengue incidence in Colombia based on altitude. Robustness checks indicated the presence of residual bias, particularly when applying the subset replacement test. These findings highlight the importance of integrating oceanic monitoring into early warning systems of the disease and tailoring vector-control strategies to local ecological contexts.

  • Open Access

    Climatic, socioeconomic, and migratory factors on the epidemiological dynamics of cutaneous leishmaniasis in Colombia, 2007–2021

    by Johanna Tapias Rivera, Ruth Martínez-Vega, Wendy Lorena Quintero-García, Dayana Sofía Torres-Martínez, Angela Liliana Monroy-Díaz, Lusayda Sánchez-Corrales, Juan David Gutiérrez-Torres

    The World Health Organization considers cutaneous leishmaniasis (CL) to be one of the most important neglected tropical diseases (NTDs). The application of geostatistical models, in conjunction with sociodemographic and environmental factors, enables the understanding of disease epidemiology and facilitates the implementation of targeted measures and effective case management. This research aimed to evaluate the association between climatic, sociodemographic, and socioeconomic factors with the monthly CL incidence rate at the municipality level in Colombia from 2007 to 2021. An ecological study was conducted, including laboratory-confirmed notifications of CL reported in municipalities located below 1,700 meters above sea level through the National Public Health Surveillance System. Climate data were sourced from NASA, and sociodemographic and socioeconomic variables were obtained from the National Planning Department. Hierarchical spatio-temporal regression models within a Bayesian framework were used to analyze the monthly CL. A total of 121,828 cases of CL were analyzed, with an annual median of 7,605 cases. Standardized incidence rates (SIR) ranged from 0 to 16,072 per 100,000 population (median: 105.7; IQR: 46.7-419). Eight of the 11 studied factors were associated with the monthly cases of CL: rainfall, urban dimension, and Venezuelan migration were associated with a decrease in CL cases, while qualitative housing deficit, internal migration, the multidimensional poverty index, the index of unmet basic needs, and forest coverage were associated with an increase in CL cases. CL incidence in Colombia fluctuated during the study period, with high spatial heterogeneity linked to climatic, sociodemographic. and socioeconomic factors. These findings highlight the necessity for customized territorial approaches to the prevention and control of CL, emphasizing the importance of considering municipal characteristics and aligning strategies with the Colombian Strategic Plan for CL.


  • Open Access

    Pooled lagged effect of runoff on leptospirosis cases in Colombia

    by Juan David Gutiérrez, Johanna Tapias-Rivera


  • Open Access

    Microclimate factors related to dengue virus burden clusters in two endemic towns of Mexico

    by Johanna Tapias-Rivera, Ruth Aralí Martínez-Vega, Susana Román-Pérez, Rene Santos-Luna, Irma Yvonne Amaya-Larios, Fredi Alexander Diaz-Quijano, José Ramos-Castañeda

    In dengue-endemic areas, transmission control is limited by the difficulty of achieving sufficient coverage and sustainability of interventions. To maximize the effectiveness of interventions, areas with higher transmission could be identified and prioritized. The aim was to identify burden clusters of Dengue virus (DENV) infection and evaluate their association with microclimatic factors in two endemic towns from southern Mexico. Information from a prospective population cohort study (2·5 years of follow-up) was used, microclimatic variables were calculated from satellite information, and a cross-sectional design was conducted to evaluate the relationship between the outcome and microclimatic variables in the five surveys. Spatial clustering was observed in specific geographic areas at different periods. Both, land surface temperature (aPR 0·945; IC95% 0·895–0·996) and soil humidity (aPR 3·018; IC95% 1·013–8·994), were independently associated with DENV burden clusters. These findings can help health authorities design focused dengue surveillance and control activities in dengue endemic areas.


  • Open Access

    Evaluación de las características microbiológicas y fisicoquímicas del agua sometida a procesos de esterilización en autoclaves a vapor

    by Johanna Tapias-Rivera, Christian Chacin-Zambrano, Oscar Guarín-Villamizar, Juan Carlos Uribe-Caputi

    El presente trabajo describe las características fisicoquímicas y microbiológicas del agua antes y después de ser sometidas a un proceso de esterilización en un autoclave a vapor con carga de instrumental y paquetes de vestuario quirúrgico, con el fin de establecer el potencial para el posterior sin causar ningún efecto en la validez de la carga por ciclo. Las mediciones fueron descritas por separado, antes del primer proceso de esterilización, durante la etapa de descarga y de la entrada del agua que fue utilizada para dicho proceso. Para el desarrollo del proceso, se realizaron tres tomas de muestras con agua de osmosis y 5 correspondientes al agua directamente de grifo; posterior a cada toma de muestra se tomaron en cuenta los parámetros de esterilización, resoluciones ambientales y microbiológicas. Los resultados obtenidos mostraron significancia en los diferentes puntos de toma de muestras que llevaron a concluir alteraciones en el agua de osmosis en los diferentes puntos de muestra (entrada, chaqueta y descarga) del autoclave en lo relacionado a las características fisicoquímicas del agua obtenida de los puntos analizados del autoclave. Adicionalmente se observó presencia de coliformes totales y fecales, aerobios mesófilos que indicaron que el agua no es apta para recirculación dentro del autoclave.Palabras clave: Agua, autoclave, esterilización, vapor. Abstract The present study sought to describe the physico-chemical and microbiological characteristics of the water before and after being subjected to UN sterilization process steam autoclave load packages instrumental and surgical clothes, in order to establish its potential usefulness f back without causing any effect on the validity of the charging cycle. Were the measurements described Separately, Before the sterilization process, during the discharge stage and the entry of water that was used for this process. Development Process Three samplings were carried out with osmosis water and 5 for tap water Directly From; after each sample took into account the parameters of sterilization, Environmental Resolutions and microbiological obtained significant results in the different points of Sampling leading one Conclude Disturbances osmosis water at different points Sample (input, jacket Download and) the autoclave in relation to the physico-chemical characteristics of water obtained from the Points analyzed the autoclave, likewise presence of total and fecal coliforms was observed aerobic mesophilic bacteria which indicated that water is not suitable for recirculation within the autoclave.Keywords: Water, autoclave, sterilization steam. Resumo O presente trabalho descreve as características físico-químicas e microbiológicas da água antes e depois de ser submetido a um processo de esterilização em uma autoclave de vapor carregada com instrumentos e embalagens de vestuário cirúrgico, a fim de estabelecer o potencial para o posterior sem causar qualquer efeito sobre a validade da carga por ciclo. As medidas foram descritas separadamente, antes do primeiro processo de esterilização, durante a descarga e a fase de entrada da água que foi utilizada para o referido processo. Para o desenvolvimento do processo, foram colhidas três amostras com água de osmose e 5 correspondentes à água diretamente da torneira; Após cada amostragem, foram considerados os parâmetros de esterilização, as resoluções ambientais e microbiológicas. Os resultados obtidos mostraram diferenças significativas nos pontos de amostragem que levaram à conclusão de alterações na água de osmose nos diferentes pontos de amostra (entrada, revestimento e descarga) da autoclave em relação às características físicoquímicas da água obtida das amostras. pontos da autoclave. Além disso, observou-se a presença de coliformes totais e fecais, mesófilos aeróbicos que indicaram que a água não é adequada para a recirculação dentro da autoclave.Palavras-chave: Água, autoclave, esterilização, vapor.