Robert Kaita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Kaita has a total of 960 co-authors. Here are the top co-authors by number of shared publications:
- H. W. Kugel
Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543
32 shared publications - Rajesh Maingi
Princeton Plasma Physics Laboratory
31 shared publications - R. Majeski
Princeton University
25 shared publications H. Kugel
24 shared publications- Ronald E. Bell
Princeton Plasma Physics Laboratory, Princeton, NJ, United States of America
24 shared publications D. Stutman
Johns Hopkins University
22 shared publications
Latest Publications
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (2)
Estimates of global recycling coefficients for LTX-β discharges
We report the first observation of global recycling coefficient R near 0.5 in the Lithium Tokamak eXperiment-β (LTX-β), significantly below the minimum R previously reported in other devices. In a series of experiments with varied Li wall conditioning, estimates of the recycling coefficient have been made using a Lyman-α array and DEGAS2 modeling. A progressive reduction in Lyman-α emission with increased lithium and an increase in edge electron temperature are observed. It is also observed that with increasing Li coating thickness, the effective particle confinement time τp* is reduced and approaches TRANSP calculated energy confinement time (τE), with τp* near τE,TRANSP for the lowest recycling coefficients. Edge temperatures approaching core plasma temperatures, first reported in LTX, can now be directly connected to estimates of the recycling coefficient and qualitatively agree with previous UEDGE simulations. The particle flux to the limiting surfaces appears to be significantly reduced in comparison with fluid scrape-off layer (SOL) models, indicating that a large fraction of the SOL ions are mirror trapped. SOL collisionality drops more than an order of magnitude below the banana regime boundary, indicating the importance of kinetic effects. Full-f 1x2v gyrokinetic simulations of SOL field lines with the GKEYLL code indicate that the fraction of ions trapped along field lines increases as collisionality drops, as a result of increased lithium evaporation.
- 1 February 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (2)
Open AccessEstimates of global recycling coefficients for LTX-β discharges
We report the first observation of global recycling coefficient R near 0.5 in the Lithium Tokamak eXperiment-β (LTX-β), significantly below the minimum R previously reported in other devices. In a series of experiments with varied Li wall conditioning, estimates of the recycling coefficient have been made using a Lyman-α array and DEGAS2 modeling. A progressive reduction in Lyman-α emission with increased lithium and an increase in edge electron temperature are observed. It is also observed that with increasing Li coating thickness, the effective particle confinement time τp* is reduced and approaches TRANSP calculated energy confinement time (τE), with τp* near τE,TRANSP for the lowest recycling coefficients. Edge temperatures approaching core plasma temperatures, first reported in LTX, can now be directly connected to estimates of the recycling coefficient and qualitatively agree with previous UEDGE simulations. The particle flux to the limiting surfaces appears to be significantly reduced in comparison with fluid scrape-off layer (SOL) models, indicating that a large fraction of the SOL ions are mirror trapped. SOL collisionality drops more than an order of magnitude below the banana regime boundary, indicating the importance of kinetic effects. Full-f 1x2v gyrokinetic simulations of SOL field lines with the GKEYLL code indicate that the fraction of ions trapped along field lines increases as collisionality drops, as a result of increased lithium evaporation.
- Open Access
- 1 February 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (2) , 026104
A simple vacuum suitcase for enabling plasma facing component characterization in fusion devices
We have demonstrated a vacuum suitcase to transport samples in vacuo to a surface analysis station for characterization of tokamak plasma facing components (PFCs). This technique enables surface analysis at powerful, dedicated stations that are not encumbered by design constraints imposed on them by a tokamak. The vacuum suitcase is an alternative solution to characterizing PFCs using diagnostics that are designed and built around a tokamak. The vacuum suitcase, called the Sample Exposure Probe (SEP), features mobile ultra-high vacuum pumping. Active pumping under high vacuum enables sample transfer between the Lithium Tokamak eXperiment-β (LTX-β) and a high resolution X-ray Photoelectron Spectroscopy (XPS) system that is situated close by. A thermocouple inserted in the back of the sample head measures heat flux from the plasma during exposure, and together with a button heater, allows the sample to match the LTX-β PFCs in high temperature operations. As vacuum conditions are better during transfer and analysis than in the tokamak, less contamination is introduced to the samples. XPS scans on a dedicated analysis station enable peak identification due to higher resolution and signal to noise ratio. A similar probe could be implemented for other fusion devices. The SEP is the first vacuum suitcase implementation for fusion applications that incorporates active pumping.
- 1 February 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (2) , 026104
Open AccessA simple vacuum suitcase for enabling plasma facing component characterization in fusion devices
We have demonstrated a vacuum suitcase to transport samples in vacuo to a surface analysis station for characterization of tokamak plasma facing components (PFCs). This technique enables surface analysis at powerful, dedicated stations that are not encumbered by design constraints imposed on them by a tokamak. The vacuum suitcase is an alternative solution to characterizing PFCs using diagnostics that are designed and built around a tokamak. The vacuum suitcase, called the Sample Exposure Probe (SEP), features mobile ultra-high vacuum pumping. Active pumping under high vacuum enables sample transfer between the Lithium Tokamak eXperiment-β (LTX-β) and a high resolution X-ray Photoelectron Spectroscopy (XPS) system that is situated close by. A thermocouple inserted in the back of the sample head measures heat flux from the plasma during exposure, and together with a button heater, allows the sample to match the LTX-β PFCs in high temperature operations. As vacuum conditions are better during transfer and analysis than in the tokamak, less contamination is introduced to the samples. XPS scans on a dedicated analysis station enable peak identification due to higher resolution and signal to noise ratio. A similar probe could be implemented for other fusion devices. The SEP is the first vacuum suitcase implementation for fusion applications that incorporates active pumping.
- 7 October 2019
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 61 (11) , 113001
Fusion applications for lithium: wall conditioning in magnetic confinement devices
The application of lithium to plasma facing components (PFCs) has been widely used to improve plasma performance in magnetic confinement devices. The ability of lithium to retain hydrogen isotopes has been exploited to lower wall recycling. Low recycling leads to high edge plasma temperatures, and decreased temperature gradients reduce the free energy source for microinstabilities that cause transport. A variety of techniques have been developed to introduce lithium into fusion research devices, and its beneficial effects have been observed in their plasmas. The mechanism for the retention of hydrogen isotopes has been elucidated by detailed surface science studies, and ‘first principles’ molecular dynamics simulations. The remaining challenges primarily pertain to long pulse operation. Our knowledge of erosion, transport, and redeposition needs to improve for the mixed material PFCs lithium creates. Flowing liquid lithium systems also must be demonstrated for the replenishable lithium walls that fusion reactors require.
- 7 October 2019
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 61 (11) , 113001
Fusion applications for lithium: wall conditioning in magnetic confinement devices
The application of lithium to plasma facing components (PFCs) has been widely used to improve plasma performance in magnetic confinement devices. The ability of lithium to retain hydrogen isotopes has been exploited to lower wall recycling. Low recycling leads to high edge plasma temperatures, and decreased temperature gradients reduce the free energy source for microinstabilities that cause transport. A variety of techniques have been developed to introduce lithium into fusion research devices, and its beneficial effects have been observed in their plasmas. The mechanism for the retention of hydrogen isotopes has been elucidated by detailed surface science studies, and ‘first principles’ molecular dynamics simulations. The remaining challenges primarily pertain to long pulse operation. Our knowledge of erosion, transport, and redeposition needs to improve for the mixed material PFCs lithium creates. Flowing liquid lithium systems also must be demonstrated for the replenishable lithium walls that fusion reactors require.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10C114
The high-k poloidal scattering system for NSTX-U
An 8-channel, high-k poloidal far-infrared (FIR) scattering system is under development for the National Spherical Torus eXperiment Upgrade (NSTX-U). The 693 GHz poloidal scattering system replaces a 5-channel, 280 GHz high-k toroidal scattering system to study high-k electron density fluctuations on NSTX-U. The FIR probe beam launched from Bay G is aimed toward Bay L, where large aperture optics collect radiation at 8 simultaneous scattering angles ranging from 2° to 15°. The reduced wavelength in the poloidal system results in less refraction, and coupled with a new poloidal scattering geometry, extends measurement of poloidal wavenumbers from the previous limit of 7 cm−1 up to >40 cm−1. Steerable launch optics coupled with receiver optics that can be remotely translated in 5 axes allow the scattering volume to be placed from r/a = 0.1 out to the pedestal region (r/a ∼ 0.99) and allow for both upward and downward scattering to cover different regions of the 2D fluctuation spectrum.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10C114
The high-k poloidal scattering system for NSTX-U
An 8-channel, high-k poloidal far-infrared (FIR) scattering system is under development for the National Spherical Torus eXperiment Upgrade (NSTX-U). The 693 GHz poloidal scattering system replaces a 5-channel, 280 GHz high-k toroidal scattering system to study high-k electron density fluctuations on NSTX-U. The FIR probe beam launched from Bay G is aimed toward Bay L, where large aperture optics collect radiation at 8 simultaneous scattering angles ranging from 2° to 15°. The reduced wavelength in the poloidal system results in less refraction, and coupled with a new poloidal scattering geometry, extends measurement of poloidal wavenumbers from the previous limit of 7 cm−1 up to >40 cm−1. Steerable launch optics coupled with receiver optics that can be remotely translated in 5 axes allow the scattering volume to be placed from r/a = 0.1 out to the pedestal region (r/a ∼ 0.99) and allow for both upward and downward scattering to cover different regions of the 2D fluctuation spectrum.
- 26 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10D118
The charge exchange recombination spectroscopy diagnostic on the upgraded Lithium Tokamak eXperiment (LTX-β)
The Lithium Tokamak eXperiment has undergone an upgrade to LTX-β, a major part of which is the addition of neutral beam injection (NBI). NBI has allowed for a new charge exchange recombination spectroscopy (CHERS) system to be installed in order to measure impurity concentrations, ion temperature, and toroidal velocity. Previously on LTX measuring these parameters relied on passive spectroscopy and inversion techniques and had large uncertainty. The CHERS system has 52 total views, split into four groups of 13, half facing toward the beam and half symmetrically facing away from the beam, so the background non-beam related emission can be simultaneously subtracted. Both sets of views sample a major radius of 27-59 cm, with resolution through the beam of 1.5-2.5 cm. LTX-β is expected to have its magnetic axis near 35 cm, with minor radii of 18-23 cm. Three separate spectrometers will be used for the diagnostic, giving the system great flexibility to simultaneously measure emission from multiple impurity lines. The viewing optics are f/1.8, allowing all of the spectrometers to be fully illuminated. Design and calibration of the system as well as the advantages of various configurations of the spectrometers will be highlighted.
- 26 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10D118
The charge exchange recombination spectroscopy diagnostic on the upgraded Lithium Tokamak eXperiment (LTX-β)
The Lithium Tokamak eXperiment has undergone an upgrade to LTX-β, a major part of which is the addition of neutral beam injection (NBI). NBI has allowed for a new charge exchange recombination spectroscopy (CHERS) system to be installed in order to measure impurity concentrations, ion temperature, and toroidal velocity. Previously on LTX measuring these parameters relied on passive spectroscopy and inversion techniques and had large uncertainty. The CHERS system has 52 total views, split into four groups of 13, half facing toward the beam and half symmetrically facing away from the beam, so the background non-beam related emission can be simultaneously subtracted. Both sets of views sample a major radius of 27-59 cm, with resolution through the beam of 1.5-2.5 cm. LTX-β is expected to have its magnetic axis near 35 cm, with minor radii of 18-23 cm. Three separate spectrometers will be used for the diagnostic, giving the system great flexibility to simultaneously measure emission from multiple impurity lines. The viewing optics are f/1.8, allowing all of the spectrometers to be fully illuminated. Design and calibration of the system as well as the advantages of various configurations of the spectrometers will be highlighted.
- 14 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10H114
Millimeter-wave interferometry and far-forward scattering for density fluctuation measurements on LTX-β
The λ ≈ 1 mm (f = 288 GHz) interferometer for the Lithium Tokamak Experiment-β (LTX-β) will use a chirped-frequency source and a centerstack-mounted retro-reflector mirror to provide electron line density measurements along a single radial chord at the midplane. The interferometer is unique in the use of a single source (narrow-band chirped-frequency interferometry) and a single beam splitter for separating and recombining the probe and reference beams. The current work provides a documentation of the interferometry hardware and evaluates the capabilities of the system as a far-forward collective scattering diagnostic. As such, the current optical setup is estimated to have a detection range of 0.4 ≲ k⊥ ≲ 1.7 cm−1, while an improved layout will extend the upper k⊥ limit to ∼3 cm−1. Measurements with the diagnostic on LTX are presented, showing interferometry results and scattered signal data. These diagnostics are expected to provide routine measurements on LTX-β for high frequency coherent density oscillations (e.g., Alfvénic modes during neutral beam injection) as well as for broadband turbulence.
- 14 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10H114
Millimeter-wave interferometry and far-forward scattering for density fluctuation measurements on LTX-β
The λ ≈ 1 mm (f = 288 GHz) interferometer for the Lithium Tokamak Experiment-β (LTX-β) will use a chirped-frequency source and a centerstack-mounted retro-reflector mirror to provide electron line density measurements along a single radial chord at the midplane. The interferometer is unique in the use of a single source (narrow-band chirped-frequency interferometry) and a single beam splitter for separating and recombining the probe and reference beams. The current work provides a documentation of the interferometry hardware and evaluates the capabilities of the system as a far-forward collective scattering diagnostic. As such, the current optical setup is estimated to have a detection range of 0.4 ≲ k⊥ ≲ 1.7 cm−1, while an improved layout will extend the upper k⊥ limit to ∼3 cm−1. Measurements with the diagnostic on LTX are presented, showing interferometry results and scattered signal data. These diagnostics are expected to provide routine measurements on LTX-β for high frequency coherent density oscillations (e.g., Alfvénic modes during neutral beam injection) as well as for broadband turbulence.
- 12 July 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10J104
Magnetic perturbation diagnostics in the high-temperature lithiated environment of LTX-β
Magnetic perturbation measurements will be invaluable for characterizing Lithium Tokamak Experiment Beta (LTX-β) plasmas due to the time-evolving 3D nature of the magnetic fields generated by eddy currents in the vessel and copper shell segments, as well as enhanced MHD instability drive due to newly introduced neutral beam heating. The LTX-β upgrade includes two new arrays of Mirnov coils: a shell eddy sensor array of two-axis coils distributed over the back surface of one shell segment and a toroidal array of poloidal field coils at the low-field side midplane gap. Evaporative lithium wall-coating and the high temperatures required for liquid lithium wall operation both complicate the implementation of in-vessel diagnostics. While the shell array is protected from lithium exposure, the shell segment to which it is mounted will at times exceed 300 °C. The toroidal array, however, will experience direct line-of-sight exposure to the lithium evaporator as well as close proximity to the hot shell and may also be subject to poorly confined beam-driven fast ions. We describe how the two new Mirnov coil arrays meet these environmental challenges and enhance the LTX-β diagnostic suite.
- 12 July 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10J104
Magnetic perturbation diagnostics in the high-temperature lithiated environment of LTX-β
Magnetic perturbation measurements will be invaluable for characterizing Lithium Tokamak Experiment Beta (LTX-β) plasmas due to the time-evolving 3D nature of the magnetic fields generated by eddy currents in the vessel and copper shell segments, as well as enhanced MHD instability drive due to newly introduced neutral beam heating. The LTX-β upgrade includes two new arrays of Mirnov coils: a shell eddy sensor array of two-axis coils distributed over the back surface of one shell segment and a toroidal array of poloidal field coils at the low-field side midplane gap. Evaporative lithium wall-coating and the high temperatures required for liquid lithium wall operation both complicate the implementation of in-vessel diagnostics. While the shell array is protected from lithium exposure, the shell segment to which it is mounted will at times exceed 300 °C. The toroidal array, however, will experience direct line-of-sight exposure to the lithium evaporator as well as close proximity to the hot shell and may also be subject to poorly confined beam-driven fast ions. We describe how the two new Mirnov coil arrays meet these environmental challenges and enhance the LTX-β diagnostic suite.
- 30 August 2017
- Published by IOP Publishing in Nuclear Fusion
- Vol. 57 (11) , 116056
Liquid lithium loop system to solve challenging technology issues for fusion power plant
- 30 August 2017
- Published by IOP Publishing in Nuclear Fusion
- Vol. 57 (11) , 116056
Liquid lithium loop system to solve challenging technology issues for fusion power plant
- 1 May 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (5) , 053502
A frequency-modulated continuous-wave reflectometer for the Lithium Tokamak Experiment
The frequency-modulated continuous-wave reflectometer on LTX (Lithium Tokamak Experiment) and the data analysis methods used for determining electron density profiles are described. The diagnostic uses a frequency range of 13.1–33.5 GHz, for covering a density range of 0.21– cm−3 (in O-mode polarization) with a time resolution down to 8 μs. The design of the diagnostic incorporates the concept of an “optimized” source frequency sweep, which minimizes the large variation in the intermediate frequency signal due to a long dispersive transmission line. The quality of the raw data is dictated by the tuning characteristics of the microwave sources, as well as the group delay ripple in the transmission lines, which can generate higher-order nonlinearities in the frequency sweep. Both effects are evaluated for our diagnostic and best practices are presented for minimizing “artifacts” generated in the signals. The quality of the reconstructed profiles is also improved using two additional data analysis methods. First, the reflectometer data are processed as a radar image, where clutter due to echoes from the wall and backscattering from density fluctuations can be easily identified and removed. Second, a weighed least-squares lamination algorithm POLAN (POLynomial ANalysis) is used to reconstruct the electron density profile. Examples of density profiles in LTX are presented, along with comparisons to measurements from the Thomson scattering and the λ = 1 mm interferometer diagnostics.- 1 May 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (5) , 053502
A frequency-modulated continuous-wave reflectometer for the Lithium Tokamak Experiment
The frequency-modulated continuous-wave reflectometer on LTX (Lithium Tokamak Experiment) and the data analysis methods used for determining electron density profiles are described. The diagnostic uses a frequency range of 13.1–33.5 GHz, for covering a density range of 0.21– cm−3 (in O-mode polarization) with a time resolution down to 8 μs. The design of the diagnostic incorporates the concept of an “optimized” source frequency sweep, which minimizes the large variation in the intermediate frequency signal due to a long dispersive transmission line. The quality of the raw data is dictated by the tuning characteristics of the microwave sources, as well as the group delay ripple in the transmission lines, which can generate higher-order nonlinearities in the frequency sweep. Both effects are evaluated for our diagnostic and best practices are presented for minimizing “artifacts” generated in the signals. The quality of the reconstructed profiles is also improved using two additional data analysis methods. First, the reflectometer data are processed as a radar image, where clutter due to echoes from the wall and backscattering from density fluctuations can be easily identified and removed. Second, a weighed least-squares lamination algorithm POLAN (POLynomial ANalysis) is used to reconstruct the electron density profile. Examples of density profiles in LTX are presented, along with comparisons to measurements from the Thomson scattering and the λ = 1 mm interferometer diagnostics.- 20 March 2017
- Published by AIP Publishing in Physics of Plasmas
- Vol. 24 (5) , 056110
Compatibility of lithium plasma-facing surfaces with high edge temperatures in the Lithium Tokamak Experiment
High edge electron temperatures (200 eV or greater) have been measured at the wall-limited plasma boundary in the Lithium Tokamak Experiment (LTX). Flat electron temperature profiles are a long-predicted consequence of low recycling boundary conditions. Plasma density in the outer scrape-off layer is very low, 2–3 × 1017 m−3, consistent with a low recycling metallic lithium boundary. Despite the high edge temperature, the core impurity content is low. Zeff is estimated to be ∼1.2, with a very modest contribution (<0.1) from lithium. Experiments are transient. Gas puffing is used to increase the plasma density. After gas injection stops, the discharge density is allowed to drop, and the edge is pumped by the low recycling lithium wall. An upgrade to LTX–LTX-β, which includes a 35A, 20 kV neutral beam injector (on loan to LTX from Tri-Alpha Energy) to provide core fueling to maintain constant density, as well as auxiliary heating, is underway. LTX-β is briefly described.
- 20 March 2017
- Published by AIP Publishing in Physics of Plasmas
- Vol. 24 (5) , 056110
Compatibility of lithium plasma-facing surfaces with high edge temperatures in the Lithium Tokamak Experiment
High edge electron temperatures (200 eV or greater) have been measured at the wall-limited plasma boundary in the Lithium Tokamak Experiment (LTX). Flat electron temperature profiles are a long-predicted consequence of low recycling boundary conditions. Plasma density in the outer scrape-off layer is very low, 2–3 × 1017 m−3, consistent with a low recycling metallic lithium boundary. Despite the high edge temperature, the core impurity content is low. Zeff is estimated to be ∼1.2, with a very modest contribution (<0.1) from lithium. Experiments are transient. Gas puffing is used to increase the plasma density. After gas injection stops, the discharge density is allowed to drop, and the edge is pumped by the low recycling lithium wall. An upgrade to LTX–LTX-β, which includes a 35A, 20 kV neutral beam injector (on loan to LTX from Tri-Alpha Energy) to provide core fueling to maintain constant density, as well as auxiliary heating, is underway. LTX-β is briefly described.