Di Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Di Xiao has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Janardhan Vignarajan
The Australian e-Health Research Centre, Health & Biosecurity Flagship, CSIRO
6 shared publicationsMei-Ling Tay-Kearney
The Royal Perth Hospital
3 shared publicationsBaixiang Xiao
Zhongshan Ophthalmic Center, Sun Yat-sen University , Guangzhou, China
2 shared publicationsNathan Congdon
Zhongshan Ophthalmic Center, Sun Yat-sen University , Guangzhou, China
2 shared publications- Olivier Salvado
School of Electrical Engineering and Robotics, Queensland University of Technology
2 shared publications - Pierrick Bourgeat
CSIRO Health and Biosecurity, Australian E‐Health Research Centre, Brisbane, QLD Australia
2 shared publications
Latest Publications
- Open Access
- 15 September 2019
- Published by Academy of Medicine, Singapore in Annals of the Academy of Medicine, Singapore
- Vol. 48 (9) , 282-289
Reliability of Graders and Comparison with an Automated Algorithm for Vertical Cup-Disc Ratio Grading in Fundus Photographs
Introduction: We aimed to investigate the intergrader and intragrader reliability of human graders and an automated algorithm for vertical cup-disc ratio (CDR) grading in colour fundus photographs. Materials and Methods: Two-hundred fundus photographs were selected from a database of 3000 photographs of patients screened at a tertiary ophthalmology referral centre. The graders included glaucoma specialists (n = 3), general ophthalmologists (n = 2), optometrists (n = 2), family physicians (n = 2) and a novel automated algorithm (AA). In total, 2 rounds of CDR grading were held for each grader on 2 different dates, with the photographs presented in random order. The CDR values were graded as 0.1-1.0 or ungradable. The grading results of the 2 senior glaucoma specialists were used as the reference benchmarks for comparison. Results: The intraclass correlation coefficient values ranged from 0.37-0.74 and 0.47-0.97 for intergrader and intragrader reliability, respectively. There was no significant correlation between the human graders’ level of reliability and their years of experience in grading CDR (P = 0.91). The area under the curve (AUC) value of the AA was 0.847 (comparable to AUC value of 0.876 for the glaucoma specialist). Bland Altman plots demonstrated that the AA’s performance was at least comparable to a glaucoma specialist. Conclusion: The results suggest that AA is comparable to and may have more consistent performance than human graders in CDR grading of fundus photographs. This may have potential application as a screening tool to help detect asymptomatic glaucoma-suspect patients in the community. Key words: Eyes, Glaucoma, Intraocular pressure
- 15 September 2019
- Published by Academy of Medicine, Singapore in Annals of the Academy of Medicine, Singapore
- Vol. 48 (9) , 282-289
Open AccessReliability of Graders and Comparison with an Automated Algorithm for Vertical Cup-Disc Ratio Grading in Fundus Photographs
Introduction: We aimed to investigate the intergrader and intragrader reliability of human graders and an automated algorithm for vertical cup-disc ratio (CDR) grading in colour fundus photographs. Materials and Methods: Two-hundred fundus photographs were selected from a database of 3000 photographs of patients screened at a tertiary ophthalmology referral centre. The graders included glaucoma specialists (n = 3), general ophthalmologists (n = 2), optometrists (n = 2), family physicians (n = 2) and a novel automated algorithm (AA). In total, 2 rounds of CDR grading were held for each grader on 2 different dates, with the photographs presented in random order. The CDR values were graded as 0.1-1.0 or ungradable. The grading results of the 2 senior glaucoma specialists were used as the reference benchmarks for comparison. Results: The intraclass correlation coefficient values ranged from 0.37-0.74 and 0.47-0.97 for intergrader and intragrader reliability, respectively. There was no significant correlation between the human graders’ level of reliability and their years of experience in grading CDR (P = 0.91). The area under the curve (AUC) value of the AA was 0.847 (comparable to AUC value of 0.876 for the glaucoma specialist). Bland Altman plots demonstrated that the AA’s performance was at least comparable to a glaucoma specialist. Conclusion: The results suggest that AA is comparable to and may have more consistent performance than human graders in CDR grading of fundus photographs. This may have potential application as a screening tool to help detect asymptomatic glaucoma-suspect patients in the community. Key words: Eyes, Glaucoma, Intraocular pressure
- 3 July 2019
- Published by Taylor & Francis in Ophthalmic Epidemiology
- Vol. 26 (6) , 400-407
Effect of Pupil Dilation with Tropicamide on Retinal Vascular Caliber
Purpose: The retinal blood vessels reflect changes in the brain’s micro-circulation and these changes have been shown to correlate with the incidence of diseases such as stroke, heart disease and Alzheimer’s disease. Studies investigating the retinal vasculature routinely use pupil dilation with tropicamide to optimize image acquisition and quality. The aim of this study was to investigate the effects of tropicamide on retinal vascular parameters using retinal photography. Methods: The study was performed on 41 healthy young subjects of both sexes, using tropicamide to dilate only the right pupil, leaving the left as a control. Results: Pupil dilation with tropicamide resulted in reduced retinal vessel width measures based on standardized approaches, particularly reduced arteriolar caliber (p < .0005). However, closer investigation of the images revealed reduced fundus image magnification in the post-tropicamide images, based on reduced optic nerve head diameter (p < .0005) and longitudinal analysis with image registration and affine transformation (p < .0001). No change in vessel width parameters was observed after adjustment for image magnification. Conclusion: These results suggest that tropicamide does not change the width of the retinal vessels, however width parameters as measured by standard approaches may be reduced due to image magnification changes resulting from cycloplegia. In this study, improved optic nerve head segmentation for image scale conversion removed the magnification error. With this correction, the tropicamide intervention had no effect on vessel width parameters in young healthy people and could be utilized in future without affecting the results of retinal vascular analysis.
- 3 July 2019
- Published by Taylor & Francis in Ophthalmic Epidemiology
- Vol. 26 (6) , 400-407
Effect of Pupil Dilation with Tropicamide on Retinal Vascular Caliber
Purpose: The retinal blood vessels reflect changes in the brain’s micro-circulation and these changes have been shown to correlate with the incidence of diseases such as stroke, heart disease and Alzheimer’s disease. Studies investigating the retinal vasculature routinely use pupil dilation with tropicamide to optimize image acquisition and quality. The aim of this study was to investigate the effects of tropicamide on retinal vascular parameters using retinal photography. Methods: The study was performed on 41 healthy young subjects of both sexes, using tropicamide to dilate only the right pupil, leaving the left as a control. Results: Pupil dilation with tropicamide resulted in reduced retinal vessel width measures based on standardized approaches, particularly reduced arteriolar caliber (p < .0005). However, closer investigation of the images revealed reduced fundus image magnification in the post-tropicamide images, based on reduced optic nerve head diameter (p < .0005) and longitudinal analysis with image registration and affine transformation (p < .0001). No change in vessel width parameters was observed after adjustment for image magnification. Conclusion: These results suggest that tropicamide does not change the width of the retinal vessels, however width parameters as measured by standard approaches may be reduced due to image magnification changes resulting from cycloplegia. In this study, improved optic nerve head segmentation for image scale conversion removed the magnification error. With this correction, the tropicamide intervention had no effect on vessel width parameters in young healthy people and could be utilized in future without affecting the results of retinal vascular analysis.
- 29 January 2019
- Published by Springer Nature in Machine Vision and Applications
- Vol. 30 (3) , 423-446
Major automatic diabetic retinopathy screening systems and related core algorithms: a review
- 29 January 2019
- Published by Springer Nature in Machine Vision and Applications
- Vol. 30 (3) , 423-446
Major automatic diabetic retinopathy screening systems and related core algorithms: a review
- 1 December 2017
- Published by SAGE Publications in Telemedicine and e-Health
- Vol. 23 (12) , 964-975
Content Design and System Implementation of a Teleophthalmology System for Eye Disease Diagnosis and Treatment and Its Preliminary Practice in Guangdong, China
Background: We have developed a new telemedicine system for comprehensive eye examination, diabetic retinopathy (DR) screening, and eye disease diagnosis and treatment. The novel points of the system include a tablet application for facilitating doctor's examination and diagnosis process, a comprehensive eye examination component, and integrated treatment planning and recording. Methods: The system provided a new service model through one ophthalmological center linking with multiple remote and rural hospitals for eye care in Guangdong province, China. Results: The early stage of the project study also undertook the responsibility of educations for remote-area doctors and image graders for DR grading and glaucoma grading and research on the effectiveness of short message service (SMS) reminder for patient revisit. Some other research, such as the comparison of the accuracy of graders' DR grading with the gold standard, and doctor's tentative diagnosis with final diagnosis and related statistical information, has been implemented in the system. In the preliminary practice, we summarized the outcomes related to presenting system performance and made an initial analysis. Conclusion: From the practice, the project has shown the telemedicine system and associated contents have satisfied our initial goal and demonstrated their effectiveness and efficiency.
- 1 December 2017
- Published by SAGE Publications in Telemedicine and e-Health
- Vol. 23 (12) , 964-975
Content Design and System Implementation of a Teleophthalmology System for Eye Disease Diagnosis and Treatment and Its Preliminary Practice in Guangdong, China
Background: We have developed a new telemedicine system for comprehensive eye examination, diabetic retinopathy (DR) screening, and eye disease diagnosis and treatment. The novel points of the system include a tablet application for facilitating doctor's examination and diagnosis process, a comprehensive eye examination component, and integrated treatment planning and recording. Methods: The system provided a new service model through one ophthalmological center linking with multiple remote and rural hospitals for eye care in Guangdong province, China. Results: The early stage of the project study also undertook the responsibility of educations for remote-area doctors and image graders for DR grading and glaucoma grading and research on the effectiveness of short message service (SMS) reminder for patient revisit. Some other research, such as the comparison of the accuracy of graders' DR grading with the gold standard, and doctor's tentative diagnosis with final diagnosis and related statistical information, has been implemented in the system. In the preliminary practice, we summarized the outcomes related to presenting system performance and made an initial analysis. Conclusion: From the practice, the project has shown the telemedicine system and associated contents have satisfied our initial goal and demonstrated their effectiveness and efficiency.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2017 (1557170X) , 660-663
Retinal hemorrhage detection by rule-based and machine learning approach
Robust detection of hemorrhages (HMs) in color fundus image is important in an automatic diabetic retinopathy grading system. Detection of the hemorrhages that are close to or connected with retinal blood vessels was found to be challenge. However, most methods didn't put research on it, even some of them mentioned this issue. In this paper, we proposed a novel hemorrhage detection method based on rule-based and machine learning methods. We focused on the improvement of detection of the hemorrhages that are close to or connected with retinal blood vessels, besides detecting the independent hemorrhage regions. A preliminary test for detecting HM presence was conducted on the images from two databases. We achieved sensitivity and specificity of 93.3% and 88% as well as 91.9% and 85.6% on the two datasets.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2017 (1557170X) , 660-663
Retinal hemorrhage detection by rule-based and machine learning approach
Robust detection of hemorrhages (HMs) in color fundus image is important in an automatic diabetic retinopathy grading system. Detection of the hemorrhages that are close to or connected with retinal blood vessels was found to be challenge. However, most methods didn't put research on it, even some of them mentioned this issue. In this paper, we proposed a novel hemorrhage detection method based on rule-based and machine learning methods. We focused on the improvement of detection of the hemorrhages that are close to or connected with retinal blood vessels, besides detecting the independent hemorrhage regions. A preliminary test for detecting HM presence was conducted on the images from two databases. We achieved sensitivity and specificity of 93.3% and 88% as well as 91.9% and 85.6% on the two datasets.
- 1 January 2015
- Vol. 214, 167-73
Development and Practice of Store-and-Forward Telehealth Systems in Ophthalmology Dental and Emergency.
Store-and-forward (S&F) telehealth system has been becoming an increasing application in remote medical consultations. In this paper, we will introduce three novel S&F telehealth systems we developed for ophthalmological, dental and emergency applications. We will explain the general system architecture of the S&F systems. Then we will focus on the specific features and components in each system implemented for meeting their respective clinical requirements. In the final section we will present further implementation details and practices and provide discussions.
- 1 January 2015
- Vol. 214, 167-73
Development and Practice of Store-and-Forward Telehealth Systems in Ophthalmology Dental and Emergency.
Store-and-forward (S&F) telehealth system has been becoming an increasing application in remote medical consultations. In this paper, we will introduce three novel S&F telehealth systems we developed for ophthalmological, dental and emergency applications. We will explain the general system architecture of the S&F systems. Then we will focus on the specific features and components in each system implemented for meeting their respective clinical requirements. In the final section we will present further implementation details and practices and provide discussions.
- Open Access
- 1 January 2015
- Published by IOS Press
- p. 167-173
Development and Practice of Store-and-Forward Telehealth Systems in Ophthalmology Dental and Emergency
Store-and-forward (S&F) telehealth system has been becoming an increasing application in remote medical consultations. In this paper, we will introduce three novel S&F telehealth systems we developed for ophthalmological, dental and emergency applications. We will explain the general system architecture of the S&F systems. Then we will focus on the specific features and components in each system implemented for meeting their respective clinical requirements. In the final section we will present further implementation details and practices and provide discussions.
- 1 January 2015
- Published by IOS Press
- p. 167-173
Open AccessDevelopment and Practice of Store-and-Forward Telehealth Systems in Ophthalmology Dental and Emergency
Store-and-forward (S&F) telehealth system has been becoming an increasing application in remote medical consultations. In this paper, we will introduce three novel S&F telehealth systems we developed for ophthalmological, dental and emergency applications. We will explain the general system architecture of the S&F systems. Then we will focus on the specific features and components in each system implemented for meeting their respective clinical requirements. In the final section we will present further implementation details and practices and provide discussions.
- Open Access
- 1 January 2012
- Published by Scitechnol Biosoft Pvt. Ltd. in Australasian Medical Journal
- Vol. 05 (09)
RETINAL IMAGE REGISTRATION AND COMPARISON FOR CLINICAL DECISION SUPPORTDi Xiao
- 1 January 2012
- Published by Scitechnol Biosoft Pvt. Ltd. in Australasian Medical Journal
- Vol. 05 (09)
Open AccessRETINAL IMAGE REGISTRATION AND COMPARISON FOR CLINICAL DECISION SUPPORTDi Xiao
- 1 June 2010
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 34 (4) , 321-332
An improved 3D shape context based non-rigid registration method and its application to small animal skeletons registration
- 1 June 2010
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 34 (4) , 321-332
An improved 3D shape context based non-rigid registration method and its application to small animal skeletons registration