AMAimee Louise McNamara

Aimee Louise McNamara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aimee Louise McNamara has a total of 138 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bystander Effects in Osteoblasts and Osteoclasts: Comparison Between X- and Proton-Irradiation

    by Noriyuki Okonogi, Yukako S. Otani, Keisuke Otani, Paola Divieti Pajevic, Yunhe Xie, Nicolas Depauw, Harald Paganetti, Jan Schuemann, David T. Miyamoto, Kathryn D. Held, et al.


  • Investigation of hydrogen peroxide yields and oxygen consumption in high dose rate irradiation: a TOPAS-nBio Monte Carlo study

    by Wook-Geun Shin, J Naoki D-Kondo, José Ramos-Méndez, Jay A LaVerne, Bethany Rothwell, Alejandro Bertolet, Aimee McNamara, Bruce Faddegon, Harald Paganetti, Jan Schuemann

    Objective. TOPAS-nBio enables users to simulate dose rate-dependent radiation chemical yields in water radiolysis accounting for inter-track and long-term chemistry for pulsed irradiation. This study aims to extend the TOPAS-nBio chemistry for the special case of continuous high-dose rate scenario, where both intertrack and longer time reactions need to be considered, and to quantitatively validate the extended framework by comparing the results with experimental data. Approach. The inter-track chemistry and escape G-values were first evaluated by the independent reaction time method. The escaping molecules were assumed to have a temporally continuous distribution based on the G-values using the Gillespie algorithm. The simulation results were comprehensively validated by comparing with the experimental data at different dose rates, temporal pulse shapes, and solutions. In addition, the influence of various factors, such as the chemistry model, simulation volume, temperature, pH concentration, and organic carbon contamination, was evaluated. Main results. The validation results showed that the H2O2 concentration and O2 consumption increased with dose rate, and agreed within 3% with experimental data. Computational factors related to the chemistry model and volume size were negligible. pH and temperature had an impact of less than 10% in the experimental range. The presence of organic carbon and resulting reactions doubled H2O2 yields and significantly increased O2 consumption by about an order of magnitude at lower dose rates, while the results are almost unchanged at higher dose rates. Consequently, the dose rate dependence of H2O2 yields and O2 consumption were reversed at a certain organic carbon concentration compared to the pure water results. Significance. The extended TOPAS-nBio chemistry framework enables the reproduction of the dose-rate dependent radiation chemical yields of several experimental studies at different dose rates, temporal pulse shapes, and solutions. This new functionality is necessary to investigate recent high dose rate (FLASH) experimental results.


  • FLASH Modalities Track (Oral Presentations) PROTON FLASH IRRADIATION RESULTS OF DIFFERENT TISSUES

    by Q. Zhang, E. Cascio, L. Gerweck, Q. Yang, P. Huang, A. Mcnamara, K. Nesteruk, A. Bertolet, J. Schuemann

  • Challenges in the quantification approach to a radiation relevant adverse outcome pathway for lung cancer

    by Robert Stainforth, Jan Schuemann, Aimee L. McNamara, Ruth C. Wilkins, Vinita Chauhan

    Purpose: Adverse outcome pathways (AOPs) provide a modular framework for describing sequences of biological key events (KEs) and key event relationships (KERs) across levels of biological organization. Empirical evidence across KERs can support construction of quantified AOPs (qAOPs). Using an example AOP of energy deposition from ionizing radiation onto DNA leading to lung cancer incidence, we investigate the feasibility of quantifying data from KERs supported by all types of stressors. The merits and challenges of this process in the context of AOP construction are discussed. Materials and methods: Empirical evidence across studies of dose-response from four KERs of the AOP were compiled independently for quantification. Three upstream KERs comprised of evidence from various radiation types in line with AOP guidelines. For these three KERs, a focused analysis of data from alpha-particle studies was undertaken to better characterize the process to the adverse outcome (AO) for a radon gas stressor. Numerical information was extracted from tables and graphs to plot and tabulate the response of KEs. To complement areas of the AOP quantification process, Monte Carlo (MC) simulations in TOPAS-nBio were performed to model exposure conditions relevant to the AO for an example bronchial compartment of the lung with secretory cell nuclei targets. Results: Quantification of AOP KERs highlighted the relevance of radiation types under the stressor-agnostic intent of AOP design, motivating a focus on specific types. For a given type, significant differences of KE response indicate meaningful data to derive linkages from the MIE to the AO is lacking and that better response-response focused studies are required. The MC study estimates the linear energy transfer (LET) of alpha-particles emitted by radon-222 and its progeny in the secretory cell nuclei of the example lung compartment to range from 94−5+5 - 192−18+15 keV/µm. Conclusion: Quantifying AOP components provides a means to assemble empirical evidence across different studies. This highlights challenges in the context of studies examining similar endpoints using different radiation types. Data linking KERs to a MIE of ‘deposition of energy’ is shown to be non-compatible with the stressor-agnostic principles of AOP design. Limiting data to that describing response-response relationships between adjacent KERs may better delineate studies relevant to the damage that drives a pathway to the next KE and still support an ‘all hazards’ approach. Such data remains limited and future investigations in the radiation field may consider this approach when designing experiments and reporting their results and outcomes.


  • Perspectives on the model-based approach to proton therapy trials: A retrospective study of a lung cancer randomized trial

    by Aimee L. McNamara, David C. Hall, Nadya Shusharina, Amy Liu, Xiong Wei, Ali Ajdari, Radhe Mohan, Zhongxing Liao, Harald Paganetti


  • Modelling variable proton relative biological effectiveness for treatment planning

    by Aimee McNamara, Henning Willers, Harald Paganetti

    Dose in proton radiotherapy is generally prescribed by scaling the physical proton dose by a constant value of 1.1. Relative biological effectiveness (RBE) is defined as the ratio of doses required by two radiation modalities to cause the same level of biological effect. The adoption of an RBE of 1.1. assumes that the biological efficacy of protons is similar to photons, allowing decades of clinical dose prescriptions from photon treatments and protocols to be utilized in proton therapy. There is, however, emerging experimental evidence that indicates that proton RBE varies based on technical, tissue and patient factors. The notion that a single scaling factor may be used to equate the effects of photons and protons across all biological endpoints and doses is too simplistic and raises concern for treatment planning decisions. Here, we review the models that have been developed to better predict RBE variations in tissue based on experimental data as well as using a mechanistic approach.


  • Radio-enhancement by gold nanoparticles and their impact on water radiolysis for x-ray, proton and carbon-ion beams

    by Benedikt Rudek, Aimee McNamara, Jose Ramos-Méndez, Hilary Byrne, Zdenka Kuncic, Jan Schuemann

    Gold nanoparticle (GNP) radio-enhancement is a promising technique to increase the dose deposition in a tumor while sparing neighboring healthy tissue. Previous experimental studies showed effects on cell survival and tumor control for keV x-rays but surprisingly also for MV-photons, proton and carbon-ion beams. In a systematic study, we use the Monte Carlo simulation tool TOPAS-nBio to model the GNP radio-enhancement within a cell as a function of GNP concentration, size and clustering for a wide range of energies for photons, protons and, for the first time, carbon-ions. Moreover, we include water radiolysis, which has been recognized as a major pathway of GNP mediated radio-enhancement. At a GNP concentration of 0.5% and a GNP diameter of 10 nm, the dose enhancement ratio was highest for 50 keV x-rays (1.36) and decreased in the orthovoltage (1.04 at 250 keV) and megavoltage range (1.01 at 1 MeV). The dose enhancement linearly increased with GNP concentration and decreased with GNP size and degree of clustering for all radiation modalities. While the highest physical dose enhancement at 5% concentrations was only 1.003 for 10 MeV protons and 1.004 for 100 MeV carbon-ions, we find the number of hydroxyl ( ) altered by 23% and 3% after 1 s at low, clinically-relevant concentrations. For the same concentration and proton-impact, the G-value is most sensitive to the nanoparticle size with 46 times more radical interactions at GNPs for 2 nm than for 50 nm GNP diameter within 1 s. Nanoparticle clustering was found to decrease the number of interactions at GNPs, e.g. for a cluster of 25 GNPs by a factor of 3.4. The changes in G-value correlate to the average distance between the chemical species and the GNPs. While the radiochemistry of GNP-loaded water has yet to be fully understood, this work offers a first relative quantification of radiolysis products for a broad parameter-set.


  • The microdosimetric extension in TOPAS: development and comparison with published data

    by Hongyu Zhu, Yizheng Chen, Wonmo Sung, Aimee Louise McNamara, Linh T Tran, Lucas N Burigo, Anatoly B Rosenfeld, Junli Li, Bruce Faddegon, Jan Schuemann, et al.

    Microdosimetric energy depositions have been suggested as a key variable for the modeling of the relative biological effectiveness (RBE) in proton and ion radiation therapy. However, microdosimetry has been underutilized in radiation therapy. Recent advances in detector technology allow the design of new mico- and nano-dosimeters. At the same time Monte Carlo (MC) simulations have become more widely used in radiation therapy. In order to address the growing interest in the field, a microdosimetric extension was developed in TOPAS. The extension provides users with the functionality to simulate microdosimetric spectra as well as the contribution of secondary particles to the spectra, calculate microdosimetric parameters, and determine RBE with a biological weighting function approach or with the microdosimetric kinetic (MK) model. Simulations were conducted with the extension and the results were compared with published experimental data and other simulation results for three types of microdosimeters, a spherical tissue equivalent proportional counter (TEPC), a cylindrical TEPC and a solid state microdosimeter. The corresponding microdosimetric spectra obtained with TOPAS from the plateau region to the distal tail of the Bragg curve generally show good agreement with the published data.


  • Geometrical structures for radiation biology research as implemented in the TOPAS-nBio toolkit

    by Aimee L McNamara, José Ramos-Méndez, Joseph Perl, Kathryn Held, Naoki Dominguez, Eduardo Moreno, Nicholas T Henthorn, Karen J Kirkby, Sylvain Meylan, Carmen Villagrasa, et al.

    Computational simulations, such as Monte Carlo track structure simulations, offer a powerful tool for quantitatively investigating radiation interactions within cells. The modelling of the spatial distribution of energy deposition events as well as diffusion of chemical free radical species, within realistic biological geometries, can help provide a comprehensive understanding of the effects of radiation on cells. Track structure simulations, however, generally require advanced computing skills to implement. The TOPAS-nBio toolkit, an extension to TOPAS (TOol for PArticle Simulation), aims to provide users with a comprehensive framework for radiobiology simulations, without the need for advanced computing skills. This includes providing users with an extensive library of advanced, realistic, biological geometries ranging from the micrometer scale (e.g. cells and organelles) down to the nanometer scale (e.g. DNA molecules and proteins). Here we present the geometries available in TOPAS-nBio.


  • Monte Carlo simulation of chemistry following radiolysis with TOPAS-nBio

    by J Ramos-Méndez, J Perl, J Schuemann, A McNamara, H Paganetti, B Faddegon

    Simulation of water radiolysis and the subsequent chemistry provides important information on the effect of ionizing radiation on biological material. The Geant4 Monte Carlo toolkit has added chemical processes via the Geant4-DNA project. The TOPAS tool simplifies the modeling of complex radiotherapy applications with Geant4 without requiring advanced computational skills, extending the pool of users. Thus, a new extension to TOPAS, TOPAS-nBio, is under development to facilitate the configuration of track-structure simulations as well as water radiolysis simulations with Geant4-DNA for radiobiological studies. In this work, radiolysis simulations were implemented in TOPAS-nBio. Users may now easily add chemical species and their reactions, and set parameters including branching ratios, dissociation schemes, diffusion coefficients, and reaction rates. In addition, parameters for the chemical stage were re-evaluated and updated from those used by default in Geant4-DNA to improve the accuracy of chemical yields. Simulation results of time-dependent and LET-dependent primary yields G x (chemical species per 100 eV deposited) produced at neutral pH and 25 °C by short track-segments of charged particles were compared to published measurements. The LET range was 0.05–230 keV µ m −1 . The calculated G x values for electrons satisfied the material balance equation within 0.3%, similar for protons albeit with long calculation time. A smaller geometry was used to speed up proton and alpha simulations, with an acceptable difference in the balance equation of 1.3%. Available experimental data of time-dependent G-values for agreed with simulated results within 7% ± 8% over the entire time range; for over the full time range within 3% ± 4%; for H 2 O 2 from 49% ± 7% at earliest stages and 3% ± 12% at saturation. For the LET-dependent G x , the mean ratios to the experimental data were 1.11 ± 0.98, 1.21 ± 1.11, 1.05 ± 0.52, 1.23 ± 0.59 and 1.49 ± 0.63 (1 standard deviation) for , , H 2 , H 2 O 2 and , respectively. In conclusion, radiolysis and subsequent chemistry with Geant4-DNA has been successfully incorporated in TOPAS-nBio. Results are in reasonable agreement with published measured and simulated data.