Sunil Kumar Mishra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sunil Kumar Mishra has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
Ramesh Chowdhary
Department of Prosthodontics, Sri Siddhartha Dental College and Hospital, Tumkur, India
35 shared publications- Ramesh Chowdhary
Department of Prosthodontics, Rajarajeswari Dental College and Hospital, Bengaluru, Karnataka, India
18 shared publications Puja Hazari
Department of Maxillofacial Prosthodontics and Implantology, Peoples Dental Academy, Bhopal, Madhya Pradesh, India
9 shared publicationsHarsh Mahajan
5 shared publicationsPankaj Mishra
Department of Conservative Dentistry and Endodontics, RKDF Dental College and Research Centre, Bhopal, Madhya Pradesh, India
5 shared publicationsShail Kumari
Department of Orthodontics and Dentofacial Orthopaedics, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India
5 shared publications
Latest Publications
- 6 September 2023
- Published by Springer Nature in Evidence-Based Dentistry
- Vol. 24 (4) , 193
Complete-arch implant-supported fixed dental prostheses fabricated with PEEK and PEKK framework: a systematic review
Purpose To evaluate the performance of complete-arch implant-supported fixed dental prostheses (FDPs) fabricated with polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) framework in clinical cases. Materials and methods This systematic review followed the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses and was registered in the International Prospective Register of Systematic Reviews with the number CRD42023399494. The electronic database PubMed, Cochrane Library and EBSCOhost were assessed for clinical research and reports on complete-arch implant-supported FDPs fabricated with PEEK and PEKK framework. Human studies with a minimum follow-up of 1 year and published in an English language were the only ones included. Results The initial database and hand search provided 564 articles. Finally, 12 articles published between 2018 and 2022 were included in this systematic review. The mean follow-up ranged from 1 year to 6 years. The included studies reported 119 (114 PEEK, 5 PEKK) complete-arch implant-supported FDPs during 1 year follow-up. The cumulative survival rate of prostheses with PEEK as a framework was 97.3%. Prostheses fractures and complications were found with both PEEK and PEKK frameworks. No implant failure reported with both PEEK and PEKK prostheses. Conclusion In short-term follow-up, the complete-arch implant-supported FDPs with PEEK as a framework showed a good survival rate and acceptable health of the supporting tissues. The PEEK framework had shown adhesion issues as the most common prosthetic complication. Limited data were available on PEKK as framework material, so further long-term clinical trials are required.
- 6 September 2023
- Published by Springer Nature in Evidence-Based Dentistry
- Vol. 24 (4) , 193
Complete-arch implant-supported fixed dental prostheses fabricated with PEEK and PEKK framework: a systematic review
Purpose To evaluate the performance of complete-arch implant-supported fixed dental prostheses (FDPs) fabricated with polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) framework in clinical cases. Materials and methods This systematic review followed the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses and was registered in the International Prospective Register of Systematic Reviews with the number CRD42023399494. The electronic database PubMed, Cochrane Library and EBSCOhost were assessed for clinical research and reports on complete-arch implant-supported FDPs fabricated with PEEK and PEKK framework. Human studies with a minimum follow-up of 1 year and published in an English language were the only ones included. Results The initial database and hand search provided 564 articles. Finally, 12 articles published between 2018 and 2022 were included in this systematic review. The mean follow-up ranged from 1 year to 6 years. The included studies reported 119 (114 PEEK, 5 PEKK) complete-arch implant-supported FDPs during 1 year follow-up. The cumulative survival rate of prostheses with PEEK as a framework was 97.3%. Prostheses fractures and complications were found with both PEEK and PEKK frameworks. No implant failure reported with both PEEK and PEKK prostheses. Conclusion In short-term follow-up, the complete-arch implant-supported FDPs with PEEK as a framework showed a good survival rate and acceptable health of the supporting tissues. The PEEK framework had shown adhesion issues as the most common prosthetic complication. Limited data were available on PEKK as framework material, so further long-term clinical trials are required.
- 17 June 2023
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 28 (2) , 459-468
Do antihypertensive medications have an effect on dental implants? A systematic review
Purpose The purpose of this systematic review was to compare the clinical outcomes of dental implants in users of antihypertensive medication with those of nonusers. Methods This systematic review followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and was registered in the International Prospective Register of Systematic Reviews under the number CRD42022319336. The electronic databases Medline (PubMed) and Central Cochrane were searched for relevant scientific literature published in English through May 2022. The focused question was, “Do patients taking antihypertensive medications have a similar impact on the clinical outcome and survival of dental implants compared with nonusers?”. Results A total of 49 articles were found, of which 3 articles were finally selected for a qualitative synthesis. The three studies included 959 patients. In all three studies, the commonly used medication was renin-angiotensin system (RAS) inhibitors. Two studies mentioned implant survival rate, which was 99.4% in antihypertensive medication users and 96.1% in the nonusers. One study found a higher implant stability quotient (ISQ) in patients taking antihypertensive medication (75.7 ± 5.9) compared with patients not taking antihypertensive medication (73.7 ± 8.1). Conclusions The limited available evidence showed that patient taking antihypertensive medications had comparable success rate and implant stability to patients not taking medications. The studies included patients taking different antihypertensive medications, so a drug-specific conclusion regarding the clinical outcome of dental implants is not possible. Further studies are needed, including patients taking certain antihypertensive medications, to determine their effects on dental implants.
- 17 June 2023
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 28 (2) , 459-468
Do antihypertensive medications have an effect on dental implants? A systematic review
Purpose The purpose of this systematic review was to compare the clinical outcomes of dental implants in users of antihypertensive medication with those of nonusers. Methods This systematic review followed the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and was registered in the International Prospective Register of Systematic Reviews under the number CRD42022319336. The electronic databases Medline (PubMed) and Central Cochrane were searched for relevant scientific literature published in English through May 2022. The focused question was, “Do patients taking antihypertensive medications have a similar impact on the clinical outcome and survival of dental implants compared with nonusers?”. Results A total of 49 articles were found, of which 3 articles were finally selected for a qualitative synthesis. The three studies included 959 patients. In all three studies, the commonly used medication was renin-angiotensin system (RAS) inhibitors. Two studies mentioned implant survival rate, which was 99.4% in antihypertensive medication users and 96.1% in the nonusers. One study found a higher implant stability quotient (ISQ) in patients taking antihypertensive medication (75.7 ± 5.9) compared with patients not taking antihypertensive medication (73.7 ± 8.1). Conclusions The limited available evidence showed that patient taking antihypertensive medications had comparable success rate and implant stability to patients not taking medications. The studies included patients taking different antihypertensive medications, so a drug-specific conclusion regarding the clinical outcome of dental implants is not possible. Further studies are needed, including patients taking certain antihypertensive medications, to determine their effects on dental implants.
- Open Access
- 1 April 2023
- Published by Medknow in Journal of Datta Meghe Institute of Medical Sciences University
- Vol. 18 (2) , 239-243
Stress Distribution in Implant-Supported Fixed Dental Prosthesis (Pontic Design) using Two Different Framework Materials: A Finite Element Analysis
Aim and Objectives: The stresses transferred from the implant to the surrounding bone greatly influence the clinical outcome of the implant-supported prosthesis. The role of implant-supported prostheses made from zirconia and polyether ether ketone (PEEK) material in transferring stresses is not much known. The purpose of the finite element analysis study was to evaluate stress distribution in an implant-supported fixed dental prosthesis (FDP) using two different framework materials. Materials and Methods: Two three-dimensional models of implant-supported FDPs were designed using ANSYS software, with implants in right maxillary central incisor and canine regions supporting a three-unit fixed partial denture. Model 1 was made using zirconia as a framework material and model 2 using PEEK as a framework material. A static load of 100 N was applied in two directions, i.e., vertically and obliquely at an angle of 30° along the long axis of the implant. The von Mises stress analysis was done to find stresses generated in implants and the prosthesis, and the maximum and minimum principal stress analyses were used to find the stress generated in the bone. Results: Under both the loading conditions, maximum stress concentration was observed in the connector region of model 1 (zirconia group) compared to model 2 (PEEK group); 6.28 MPa versus 2.17 MPa in vertical loading and 8.85 MPa versus 2.69 MPa in oblique loading, respectively. The stresses generated in bone were nearly similar in both models. Conclusion: The framework material does affect the load-bearing capacity of the prosthesis. Stresses observed with PEEK as framework material were lesser compared to zirconia. Therefore, PEEK can be considered a suitable framework material for implant-supported FDPs.
- 1 April 2023
- Published by Medknow in Journal of Datta Meghe Institute of Medical Sciences University
- Vol. 18 (2) , 239-243
Open AccessStress Distribution in Implant-Supported Fixed Dental Prosthesis (Pontic Design) using Two Different Framework Materials: A Finite Element Analysis
Aim and Objectives: The stresses transferred from the implant to the surrounding bone greatly influence the clinical outcome of the implant-supported prosthesis. The role of implant-supported prostheses made from zirconia and polyether ether ketone (PEEK) material in transferring stresses is not much known. The purpose of the finite element analysis study was to evaluate stress distribution in an implant-supported fixed dental prosthesis (FDP) using two different framework materials. Materials and Methods: Two three-dimensional models of implant-supported FDPs were designed using ANSYS software, with implants in right maxillary central incisor and canine regions supporting a three-unit fixed partial denture. Model 1 was made using zirconia as a framework material and model 2 using PEEK as a framework material. A static load of 100 N was applied in two directions, i.e., vertically and obliquely at an angle of 30° along the long axis of the implant. The von Mises stress analysis was done to find stresses generated in implants and the prosthesis, and the maximum and minimum principal stress analyses were used to find the stress generated in the bone. Results: Under both the loading conditions, maximum stress concentration was observed in the connector region of model 1 (zirconia group) compared to model 2 (PEEK group); 6.28 MPa versus 2.17 MPa in vertical loading and 8.85 MPa versus 2.69 MPa in oblique loading, respectively. The stresses generated in bone were nearly similar in both models. Conclusion: The framework material does affect the load-bearing capacity of the prosthesis. Stresses observed with PEEK as framework material were lesser compared to zirconia. Therefore, PEEK can be considered a suitable framework material for implant-supported FDPs.
- 1 January 2023
- Published by MRE Press
- Vol. 36 (1) , 91-+
Marginal Gap and Internal Fit of Fixed Dental Prostheses Fabricated Using Intraoral vs Extraoral Scanning: A Systematic Review and Meta-analysis
Purpose: To compare the marginal gap and internal fit of fixed dental prostheses (FDPs) fabricated using intraoral vs extraoral scanning methods. Materials and Methods: MEDLINE/PubMed and the Cochrane database were searched. The focused PICO question was: For the fabrication of FDPs, does an intraoral scanning technique result in a different marginal gap than an extraoral scanning technique? The secondary outcome assessed was internal fit. Studies were selected based on the inclusion criteria, and a meta-analysis was performed. Results: A total of 14 studies (10 in vitro and 4 in vivo) were included in the meta-analysis. Marginal gap in single crowns was evaluated in 5 studies, copings for single crowns in 5 studies, three-unit FDPs in 3 studies, and both single-crown and three-unit FDPs in 1 study. Significantly lower marginal gap was found with intraoral scanning compared to impression scanning (P < .001) and cast scanning (P < .001), and for impression scanning compared to cast scanning (P = .037). Internal fit was superior with intraoral scanning compared to impression scanning, and this difference was significant (P < .001). No significant differences were found in internal fit with cast scanning compared to intraoral or impression scanning. The mean marginal gap/internal fit was 188.3 pm/146.2 pm with intraoral scanning, 116.29 pm/168.2 pm with impression scanning, and 195.1 pm/229.1 pm with cast scanning. Conclusion: Marginal gap was lower with intraoral scanning than with impression scanning and cast scanning. Impression scanning showed less marginal gap than cast scanning. Internal fit with intraoral scanning was superior to impression scanning, but when compared to cast scanning, no difference was found. Int J Prosthodont 2023;36:91-103. doi: 10.11607/ijp.7634
- 1 January 2023
- Published by MRE Press
- Vol. 36 (1) , 91-+
Marginal Gap and Internal Fit of Fixed Dental Prostheses Fabricated Using Intraoral vs Extraoral Scanning: A Systematic Review and Meta-analysis
Purpose: To compare the marginal gap and internal fit of fixed dental prostheses (FDPs) fabricated using intraoral vs extraoral scanning methods. Materials and Methods: MEDLINE/PubMed and the Cochrane database were searched. The focused PICO question was: For the fabrication of FDPs, does an intraoral scanning technique result in a different marginal gap than an extraoral scanning technique? The secondary outcome assessed was internal fit. Studies were selected based on the inclusion criteria, and a meta-analysis was performed. Results: A total of 14 studies (10 in vitro and 4 in vivo) were included in the meta-analysis. Marginal gap in single crowns was evaluated in 5 studies, copings for single crowns in 5 studies, three-unit FDPs in 3 studies, and both single-crown and three-unit FDPs in 1 study. Significantly lower marginal gap was found with intraoral scanning compared to impression scanning (P < .001) and cast scanning (P < .001), and for impression scanning compared to cast scanning (P = .037). Internal fit was superior with intraoral scanning compared to impression scanning, and this difference was significant (P < .001). No significant differences were found in internal fit with cast scanning compared to intraoral or impression scanning. The mean marginal gap/internal fit was 188.3 pm/146.2 pm with intraoral scanning, 116.29 pm/168.2 pm with impression scanning, and 195.1 pm/229.1 pm with cast scanning. Conclusion: Marginal gap was lower with intraoral scanning than with impression scanning and cast scanning. Impression scanning showed less marginal gap than cast scanning. Internal fit with intraoral scanning was superior to impression scanning, but when compared to cast scanning, no difference was found. Int J Prosthodont 2023;36:91-103. doi: 10.11607/ijp.7634
- Open Access
- 29 August 2022
- Published by Istanbul University in İstanbul Tıp Fakültesi Dergisi
- Vol. 57 (1) , 22-27
A comparative study to evaluate the heat generated during osteotomy with conventional drill, trephine and alveolar expander
Excessively produced heat could lead to clinical failure of osseointegration. This study was done to compare the heat generated during osteotomy with the conventional drill, trephine, and alveolar expander . This in vitro study was performed on ten bovine femoral bones. In each femoral bone, three osteotomy sites were prepared at a distance of 1.5cm using the conventional drill, trephine, and alveolar expander. During osteotomy, the site was irrigated with a copius amount of normal saline. Osteotomy sites of 3.6 mm in diameter and 11.5 mm in length were prepared using the conventional drill and bone trephines. The alveolar expander used for preparing the osteotomy site was 3.5mm, the nearest dimensions available. The temperature rise was measured using a thermocouple thermometer. Repeated measures ANOVA and Fisher’s least significant difference pairwise comparison test was done for statistical analysis. Repeated measures ANOVA revealed a significant difference in the heat generation with the conventional drill, trephine, and alveolar expander (p<0.001). The mean heat generated was maximum with the trephine (28.26±0.246 0C) followed by the conventional drill (27.27±0.297 0C) and least with alveolar expander (25.64±0.142 0C). Pairwise comparison showed a significant difference in heat generated during osteotomy with conventional drill compared to trephine (P=0.023), conventional drill compared to alveolar expander (P=0.014), and trephine compared to alveolar expander (P<0.001). The heat generated with trephine was maximum compared to the alveolar expander and conventional drills. If in case trephine is to be used, both internal and external irrigation must be used. Less heat generation during osteotomy by alveolar expander seems very promising and advantageous for better osseointegration.
- 29 August 2022
- Published by Istanbul University in İstanbul Tıp Fakültesi Dergisi
- Vol. 57 (1) , 22-27
Open AccessA comparative study to evaluate the heat generated during osteotomy with conventional drill, trephine and alveolar expander
Excessively produced heat could lead to clinical failure of osseointegration. This study was done to compare the heat generated during osteotomy with the conventional drill, trephine, and alveolar expander . This in vitro study was performed on ten bovine femoral bones. In each femoral bone, three osteotomy sites were prepared at a distance of 1.5cm using the conventional drill, trephine, and alveolar expander. During osteotomy, the site was irrigated with a copius amount of normal saline. Osteotomy sites of 3.6 mm in diameter and 11.5 mm in length were prepared using the conventional drill and bone trephines. The alveolar expander used for preparing the osteotomy site was 3.5mm, the nearest dimensions available. The temperature rise was measured using a thermocouple thermometer. Repeated measures ANOVA and Fisher’s least significant difference pairwise comparison test was done for statistical analysis. Repeated measures ANOVA revealed a significant difference in the heat generation with the conventional drill, trephine, and alveolar expander (p<0.001). The mean heat generated was maximum with the trephine (28.26±0.246 0C) followed by the conventional drill (27.27±0.297 0C) and least with alveolar expander (25.64±0.142 0C). Pairwise comparison showed a significant difference in heat generated during osteotomy with conventional drill compared to trephine (P=0.023), conventional drill compared to alveolar expander (P=0.014), and trephine compared to alveolar expander (P<0.001). The heat generated with trephine was maximum compared to the alveolar expander and conventional drills. If in case trephine is to be used, both internal and external irrigation must be used. Less heat generation during osteotomy by alveolar expander seems very promising and advantageous for better osseointegration.
- Open Access
- 5 May 2022
- Published by Istanbul University in İstanbul Tıp Fakültesi Dergisi
- Vol. 56 (2) , 61-66
The effects of reinforcement with nanoparticles of polyetheretherketone, zirconium oxide and its mixture on flexural strength of PMMA resin
Polymethylmethacrylate denture bases are prone to fracture, so reinforcement of dentures with nanoparticles is required to overcome these challenges. This invitro study was done to assess the effect of reinforcement with nanoparticles of polyetheretherketone (PEEK), zirconium oxide (ZrO2) and its mixture on flexural strength of polymethylmeythacrylate resin. A total of 60 acrylic resin specimens measuring 65 mm × 10 mm × 2.5 mm were fabricated. The specimens were divided in to fifteen specimens in each group [control group (C), 3wt% PEEK group (P), 3wt% zirconia group (Z), and hybrid reinforcement of 1.5wt% PEEK and 1.5wt% ZrO2 group (P-Z)]. The flexural strength of the specimens was evaluated using a three-point bending test on a universal testing machine. The statistical analysis was done using one-way analysis of variance (ANOVA), and the intergroup comparison was done using Tukey’s post hoc analysis. The mean flexural strength was maximum in group P-Z (98.73MPa) followed by group P (86.22 MPa) and group Z (84.48 MPa). The mean flexural strength was least in the control group (74.86MPa). One-way ANOVA revealed a highly significant (P<0.01) difference among the groups. Pairwise comparison among groups showed a significant difference (P<0.05) among all the groups except in between groups P and Z where no significant difference was found (P=0.406). Hybrid reinforced PEEK and zirconia could be used as an effective reinforcement material for denture base resin. The hybrid PEEK and zirconia reinforced resin can be an alternative treatment option in patients with heavy occlusal forces and for patients who have previous experience of multiple denture fractures.
- 5 May 2022
- Published by Istanbul University in İstanbul Tıp Fakültesi Dergisi
- Vol. 56 (2) , 61-66
Open AccessThe effects of reinforcement with nanoparticles of polyetheretherketone, zirconium oxide and its mixture on flexural strength of PMMA resin
Polymethylmethacrylate denture bases are prone to fracture, so reinforcement of dentures with nanoparticles is required to overcome these challenges. This invitro study was done to assess the effect of reinforcement with nanoparticles of polyetheretherketone (PEEK), zirconium oxide (ZrO2) and its mixture on flexural strength of polymethylmeythacrylate resin. A total of 60 acrylic resin specimens measuring 65 mm × 10 mm × 2.5 mm were fabricated. The specimens were divided in to fifteen specimens in each group [control group (C), 3wt% PEEK group (P), 3wt% zirconia group (Z), and hybrid reinforcement of 1.5wt% PEEK and 1.5wt% ZrO2 group (P-Z)]. The flexural strength of the specimens was evaluated using a three-point bending test on a universal testing machine. The statistical analysis was done using one-way analysis of variance (ANOVA), and the intergroup comparison was done using Tukey’s post hoc analysis. The mean flexural strength was maximum in group P-Z (98.73MPa) followed by group P (86.22 MPa) and group Z (84.48 MPa). The mean flexural strength was least in the control group (74.86MPa). One-way ANOVA revealed a highly significant (P<0.01) difference among the groups. Pairwise comparison among groups showed a significant difference (P<0.05) among all the groups except in between groups P and Z where no significant difference was found (P=0.406). Hybrid reinforced PEEK and zirconia could be used as an effective reinforcement material for denture base resin. The hybrid PEEK and zirconia reinforced resin can be an alternative treatment option in patients with heavy occlusal forces and for patients who have previous experience of multiple denture fractures.
- Open Access
- 1 December 2021
- Published by Jaypee Brothers Medical Publishing in International Journal of Prosthodontics and Restorative Dentistry
- Vol. 11 (4) , 157
Current Evidence on the Efficacy of Denture Adhesives in Complete Denture Wearers
- 1 December 2021
- Published by Jaypee Brothers Medical Publishing in International Journal of Prosthodontics and Restorative Dentistry
- Vol. 11 (4) , 157
Open AccessCurrent Evidence on the Efficacy of Denture Adhesives in Complete Denture Wearers
- Open Access
- 30 September 2021
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 58 (3) , 359-367
Comparative analysis of stress distribution around CFR‑PEEK implants and titanium implants with different prosthetic crowns: A finite element analysis
Polyetheretherketone (PEEK) is a new material that was introduced for the fabrication of implants and their superstructure along with other available materials. It is not yet known whether the carbon fiber-reinforced polyetheretherketone (CFR‑PEEK) material can be used as an implant and its superstructure in place of titanium (Ti). The study evaluated stress distribution around CFR‑PEEK implants and Ti implants with 5 different prosthetic crowns. A three-dimensional (3D) model of a bone block was created to represent the right maxillary premolar area with a bone-level implant system with 100% osseointegration, using the Ansys Workbench software, v. 15.0. In total, 10 3D finite element analysis (FEA) models were created. The models were divided into 2 groups according to the type of implant: the CFR‑PEEK group (n = 5); and the Ti group (n = 5). Each group was subdivided to imitate 5 different restorative crown materials (PEEK, zirconia, porcelain fused to metal (PFM), metal, and acrylic resin). Each implant model was loaded vertically (200 N) and obliquely (100 N). Stress distribution in the implants, the abutments, the cement layers, and the crowns was evaluated using the von Mises stress analysis. Maximum and minimum principal stress analyses were used to determine the stress generated in the bone. The CFR‑PEEK implants bore more stress in vertical and oblique loading as compared to the Ti implants. The stress generated in the bone with the CFR‑PEEK implants was similar to that generated with the Ti implants under vertical loading. Under oblique loading, less stress was transferred to the bone with the CFR‑PEEK implants as compared to the Ti implants, showing better adaptation of the CFR‑PEEK implants to lateral stress. In this FEA study, the amount of stress generated within the bone in the case of the CFR‑PEEK implants with different restorative crowns was smaller in comparison with the Ti implants in oblique loading. This could help reduce lateral stress on implants as well as crestal bone loss.
- 30 September 2021
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 58 (3) , 359-367
Open AccessComparative analysis of stress distribution around CFR‑PEEK implants and titanium implants with different prosthetic crowns: A finite element analysis
Polyetheretherketone (PEEK) is a new material that was introduced for the fabrication of implants and their superstructure along with other available materials. It is not yet known whether the carbon fiber-reinforced polyetheretherketone (CFR‑PEEK) material can be used as an implant and its superstructure in place of titanium (Ti). The study evaluated stress distribution around CFR‑PEEK implants and Ti implants with 5 different prosthetic crowns. A three-dimensional (3D) model of a bone block was created to represent the right maxillary premolar area with a bone-level implant system with 100% osseointegration, using the Ansys Workbench software, v. 15.0. In total, 10 3D finite element analysis (FEA) models were created. The models were divided into 2 groups according to the type of implant: the CFR‑PEEK group (n = 5); and the Ti group (n = 5). Each group was subdivided to imitate 5 different restorative crown materials (PEEK, zirconia, porcelain fused to metal (PFM), metal, and acrylic resin). Each implant model was loaded vertically (200 N) and obliquely (100 N). Stress distribution in the implants, the abutments, the cement layers, and the crowns was evaluated using the von Mises stress analysis. Maximum and minimum principal stress analyses were used to determine the stress generated in the bone. The CFR‑PEEK implants bore more stress in vertical and oblique loading as compared to the Ti implants. The stress generated in the bone with the CFR‑PEEK implants was similar to that generated with the Ti implants under vertical loading. Under oblique loading, less stress was transferred to the bone with the CFR‑PEEK implants as compared to the Ti implants, showing better adaptation of the CFR‑PEEK implants to lateral stress. In this FEA study, the amount of stress generated within the bone in the case of the CFR‑PEEK implants with different restorative crowns was smaller in comparison with the Ti implants in oblique loading. This could help reduce lateral stress on implants as well as crestal bone loss.
- 29 October 2020
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 25 (2) , 159-174
Identification of anterior loop in different populations to avoid nerve injury during surgical procedures—a systematic review and meta-analysis
Exact recognition of the anterior loop is very important to avert any injury to the neurovascular bundle during surgical procedures. The purpose of this review was to evaluate the prevalence and length of the anterior loop in different populations. A comprehensive search of Medline/Pubmed and Cochrane database was done. The focused question was the presence of anterior loop (including loop length) of the inferior alveolar nerve in mental foramen region in CBCT images of the various subjects. Articles related to the presence of anterior loop (including loop length) were only included. Initial literature search resulted in 3024 papers, after removing duplicate articles, 2821 articles were left. Two thousand seven hundred eighty-four articles were further excluded by the reviewers after screening the abstracts which resulted in 37 studies. Hand searching resulted in 2 additional papers. Seven full-text articles were excluded for not fulfilling the inclusion criteria. Finally, 32 articles were included in the review. Two thousand five hundred three subjects with anterior loop were found, which approximates 38% with 48.4% bilateral, 27.8% right side, and 23.8% left side. The loop distribution in males and females was also found to be different. There was highly significant (P < 0.001; I2 = 98.81%) heterogeneity found in the included studies. Variations were found in the prevalence, length, gender, and side distribution of anterior loop in various populations. This systematic review highly recommends not relying on any average values and the clinician should compulsorily make use of imaging modalities available in each and every case, wherever surgical procedure is to be performed near mental foramen region.
- 29 October 2020
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 25 (2) , 159-174
Identification of anterior loop in different populations to avoid nerve injury during surgical procedures—a systematic review and meta-analysis
Exact recognition of the anterior loop is very important to avert any injury to the neurovascular bundle during surgical procedures. The purpose of this review was to evaluate the prevalence and length of the anterior loop in different populations. A comprehensive search of Medline/Pubmed and Cochrane database was done. The focused question was the presence of anterior loop (including loop length) of the inferior alveolar nerve in mental foramen region in CBCT images of the various subjects. Articles related to the presence of anterior loop (including loop length) were only included. Initial literature search resulted in 3024 papers, after removing duplicate articles, 2821 articles were left. Two thousand seven hundred eighty-four articles were further excluded by the reviewers after screening the abstracts which resulted in 37 studies. Hand searching resulted in 2 additional papers. Seven full-text articles were excluded for not fulfilling the inclusion criteria. Finally, 32 articles were included in the review. Two thousand five hundred three subjects with anterior loop were found, which approximates 38% with 48.4% bilateral, 27.8% right side, and 23.8% left side. The loop distribution in males and females was also found to be different. There was highly significant (P < 0.001; I2 = 98.81%) heterogeneity found in the included studies. Variations were found in the prevalence, length, gender, and side distribution of anterior loop in various populations. This systematic review highly recommends not relying on any average values and the clinician should compulsorily make use of imaging modalities available in each and every case, wherever surgical procedure is to be performed near mental foramen region.