Shannon B. Hill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shannon B. Hill has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Nadir S. Faradzhev
National Institute of Standards and Technology Gaithersburg MD 20899 USA
3 shared publications - Cedric J. Powell
Associate, Materials Measurement Science Division National Institute of Standards and Technology Gaithersburg Maryland USA
2 shared publications - Charles Tarrio
National Institute of Standards and Technology (United States)
1 shared publication - Ivan Ermanoski
School of Sustainability, Arizona State University, Tempe, AZ, 85287-8204, USA
1 shared publication Manish Chandhok
Intel
1 shared publication- Ming Fang
Tsinghua University
1 shared publication
Latest Publications
- 29 September 2017
- Published by Wiley in Surface and Interface Analysis
- Vol. 49 (12) , 1187-1205
Quantitative analysis of trace levels of surface contamination by X‐ray photoelectron spectroscopy. Part I: Statistical uncertainty near the detection limit
We discuss the problem of quantifying common sources of statistical uncertainties for analyses of trace levels of surface contamination by using X‐ray photoelectron spectroscopy. We examine the propagation of error for peak‐area measurements by using common forms of linear and polynomial background subtraction including the correlation of points used to determine both background and peak areas. This correlation has been neglected in previous analyses, but we show that it contributes significantly to the peak‐area uncertainty near the detection limit. We introduce the concept of relative background subtraction variance (RBSV) that quantifies the uncertainty introduced by the method of background determination relative to the uncertainty of the background area itself. The uncertainties of the peak area and atomic concentration and of the detection limit are expressed using the RBSV, which separates the contributions from the acquisition parameters, the background‐determination method, and the properties of the measured spectrum. These results are then combined to find acquisition strategies that minimize the total measurement time needed to achieve a desired detection limit or atomic‐percentage uncertainty for a particular trace element. Minimization of data‐acquisition time is important for samples that are sensitive to X‐ray dose and also for laboratories that need to optimize throughput.
- 29 September 2017
- Published by Wiley in Surface and Interface Analysis
- Vol. 49 (12) , 1187-1205
Quantitative analysis of trace levels of surface contamination by X‐ray photoelectron spectroscopy. Part I: Statistical uncertainty near the detection limit
We discuss the problem of quantifying common sources of statistical uncertainties for analyses of trace levels of surface contamination by using X‐ray photoelectron spectroscopy. We examine the propagation of error for peak‐area measurements by using common forms of linear and polynomial background subtraction including the correlation of points used to determine both background and peak areas. This correlation has been neglected in previous analyses, but we show that it contributes significantly to the peak‐area uncertainty near the detection limit. We introduce the concept of relative background subtraction variance (RBSV) that quantifies the uncertainty introduced by the method of background determination relative to the uncertainty of the background area itself. The uncertainties of the peak area and atomic concentration and of the detection limit are expressed using the RBSV, which separates the contributions from the acquisition parameters, the background‐determination method, and the properties of the measured spectrum. These results are then combined to find acquisition strategies that minimize the total measurement time needed to achieve a desired detection limit or atomic‐percentage uncertainty for a particular trace element. Minimization of data‐acquisition time is important for samples that are sensitive to X‐ray dose and also for laboratories that need to optimize throughput.
- 28 September 2017
- Published by Wiley in Surface and Interface Analysis
- Vol. 49 (12) , 1214-1224
Quantitative analysis of trace levels of surface contamination by X‐ray photoelectron spectroscopy. Part II: Systematic uncertainties and absolute quantification
We discuss analyses of trace levels of surface contamination using X‐ray photoelectron spectroscopy (XPS). The problem of quantifying common sources of statistical and systematic uncertainties for these measurements is formulated in terms of the needs of extreme ultraviolet lithography, but the results and conclusions are applicable to a broad range of XPS applications. We quantify the systematic uncertainties introduced by particular cases of overlapping peaks on different substrate structures by simulating measured spectra with the National Institute of Standards and Technology Database for the Simulation of Electron Spectra for Surface Analysis (SESSA). One example demonstrates that the relative atomic concentrations of trace elements such as S, P, and halogens on a Ru surface could be dramatically overestimated if the fitting of the overlapping Ru 3d and C 1s peaks excludes the contribution from carbon. We also show how spectra generated by SESSA can be compared with measured spectra to determine absolute amounts of surface impurities on layered samples of the type used for extreme ultraviolet lithography. We provide estimates of the total uncertainty for such measurements by considering the systematic limitations of SESSA and the statistical uncertainties of the measurements. The same procedure can be employed for other multilayered materials. Finally, we describe two approaches for converting XPS detection limits for an elemental impurity in an elemental matrix to the corresponding detection limits for the impurity as a thin film on the surface of the matrix material.
- 28 September 2017
- Published by Wiley in Surface and Interface Analysis
- Vol. 49 (12) , 1214-1224
Quantitative analysis of trace levels of surface contamination by X‐ray photoelectron spectroscopy. Part II: Systematic uncertainties and absolute quantification
We discuss analyses of trace levels of surface contamination using X‐ray photoelectron spectroscopy (XPS). The problem of quantifying common sources of statistical and systematic uncertainties for these measurements is formulated in terms of the needs of extreme ultraviolet lithography, but the results and conclusions are applicable to a broad range of XPS applications. We quantify the systematic uncertainties introduced by particular cases of overlapping peaks on different substrate structures by simulating measured spectra with the National Institute of Standards and Technology Database for the Simulation of Electron Spectra for Surface Analysis (SESSA). One example demonstrates that the relative atomic concentrations of trace elements such as S, P, and halogens on a Ru surface could be dramatically overestimated if the fitting of the overlapping Ru 3d and C 1s peaks excludes the contribution from carbon. We also show how spectra generated by SESSA can be compared with measured spectra to determine absolute amounts of surface impurities on layered samples of the type used for extreme ultraviolet lithography. We provide estimates of the total uncertainty for such measurements by considering the systematic limitations of SESSA and the statistical uncertainties of the measurements. The same procedure can be employed for other multilayered materials. Finally, we describe two approaches for converting XPS detection limits for an elemental impurity in an elemental matrix to the corresponding detection limits for the impurity as a thin film on the surface of the matrix material.
- 1 October 2016
- Published by Elsevier in Surface Science
- Vol. 652, 200-205
EUV-induced oxidation of carbon on TiO2
- 1 October 2016
- Published by Elsevier in Surface Science
- Vol. 652, 200-205
EUV-induced oxidation of carbon on TiO2
- Open Access
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6517, 65170G-65170G-12
Critical parameters influencing the EUV-induced damage of Ru-capped multilayer mirrors
Endurance testing of Ru-capped multilayer mirrors (MLMs) at the NIST synchrotron facility has revealed that the damage resulting from EUV irradiation in a water-dominated environment is nonlinear and may be influenced by competing oxidation and carbon-deposition processes. Concurrent results from two different environmental chambers reveal non-intuitive relationships between reflectivity loss and the admitted water-vapor partial pressure, the ambient background-gas composition, the presence or absence of hot filaments in the chamber, the EUV intensity and the irradiation dose. We discuss possible mechanisms and propose further experiments to test them. Determining the MLM lifetime from accelerated tests is a very difficult task. It is crucial that any lifetime testing procedure involves duplicate exposures for consistency, and, if possible, testing in multiple facilities.
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6517, 65170G-65170G-12
Open AccessCritical parameters influencing the EUV-induced damage of Ru-capped multilayer mirrors
Endurance testing of Ru-capped multilayer mirrors (MLMs) at the NIST synchrotron facility has revealed that the damage resulting from EUV irradiation in a water-dominated environment is nonlinear and may be influenced by competing oxidation and carbon-deposition processes. Concurrent results from two different environmental chambers reveal non-intuitive relationships between reflectivity loss and the admitted water-vapor partial pressure, the ambient background-gas composition, the presence or absence of hot filaments in the chamber, the EUV intensity and the irradiation dose. We discuss possible mechanisms and propose further experiments to test them. Determining the MLM lifetime from accelerated tests is a very difficult task. It is crucial that any lifetime testing procedure involves duplicate exposures for consistency, and, if possible, testing in multiple facilities.