Takashi Uchida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takashi Uchida has a total of 358 co-authors. Here are the top co-authors by number of shared publications:
A. Kitagawa
National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan
15 shared publicationsM. Muramatsu
National Institute of Radiological Sciences (NIRS), Chiba 263-8555, Japan
15 shared publicationsY. Kato
Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871, Japan
14 shared publicationsY. Yoshida
Faculty of Science and Engineering, Toyo University, Kawagoe 350-8585, Japan
14 shared publicationsS. Biri
Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen, Hungary
12 shared publicationsYoshikazu Yoshida
Graduate School of Interdisciplinary New Science, Toyo University, 2100, Kujirai, Kawagoe-shi, Saitama 350-8585, Japan
10 shared publications
Latest Publications
- Open Access
Chemical synthesis and cytotoxicity of neo-glycolipids; rare sugar-glycerol-lipid compounds
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 090017
On the formation mechanism of modified fullerenes in the two-chamber configuration of the bio-nano ECRIS
Recently, we reported a fullerene modification using neutral-neutral or neutral-ion collision reactions in the two-chamber configuration of the Bio-Nano electron cyclotron resonance ion source (ECRIS). In our methodology, modified fullerenes can be synthesized in vapor-phase in an ECR plasma, or on a surface of a plasma chamber, and can be characterized by on-line mass spectrometric analysis of the ECRIS beam, or by off-line analyses (e.g. time-of-flight mass spectrometry, liquid chromatography mass spectrometry, etc.). So far, we have successfully synthesized a modified C70 with iron (Fe) and chlorine (Cl) atoms using two individual plasmas; Fe-Cl plasma and C70 plasma. In a subsequent experiment, shown in this study, we investigated the ion/electron density distributions in the plasma chamber by using electrostatic probe method. We correlated these results with the off-line synthesized material investigations and also with plasma electron simulations in order to collect more information on the mechanism of the synthesis process.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 090017
On the formation mechanism of modified fullerenes in the two-chamber configuration of the bio-nano ECRIS
Recently, we reported a fullerene modification using neutral-neutral or neutral-ion collision reactions in the two-chamber configuration of the Bio-Nano electron cyclotron resonance ion source (ECRIS). In our methodology, modified fullerenes can be synthesized in vapor-phase in an ECR plasma, or on a surface of a plasma chamber, and can be characterized by on-line mass spectrometric analysis of the ECRIS beam, or by off-line analyses (e.g. time-of-flight mass spectrometry, liquid chromatography mass spectrometry, etc.). So far, we have successfully synthesized a modified C70 with iron (Fe) and chlorine (Cl) atoms using two individual plasmas; Fe-Cl plasma and C70 plasma. In a subsequent experiment, shown in this study, we investigated the ion/electron density distributions in the plasma chamber by using electrostatic probe method. We correlated these results with the off-line synthesized material investigations and also with plasma electron simulations in order to collect more information on the mechanism of the synthesis process.
- 12 February 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 13 (6) , 876-881
Characteristics of thin‐film spiral antenna‐coupled Bi microbolometer fabricated on Si3N4/SiO2 membrane
A thin‐film spiral antenna‐coupled Bi microbolometer was fabricated on a Si3N4/SiO2 membrane. The membrane was realized by wet etching from the back of an Si substrate using a 26 wt% KOH solution. The antenna was designed in accordance with the current band theory so that it covers the frequency range of 140–220 GHz. The experimental patterns for antennas located on the membrane and on the membrane backed by a copper plate reflector were in good agreement with theoretical patterns for the antenna located in air. Furthermore, a wide band characteristic of the antenna ranging from 140 to 220 GHz was obtained. The responsivity of the Bi microbolometer on the membrane estimated from the DC sensitivity under the irradiation of 220 GHz electromagnetic wave was 110 V/W. This value is about one order of magnitude higher than that of a Bi bolometer fabricated on a dielectric substrate. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 12 February 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 13 (6) , 876-881
Characteristics of thin‐film spiral antenna‐coupled Bi microbolometer fabricated on Si3N4/SiO2 membrane
A thin‐film spiral antenna‐coupled Bi microbolometer was fabricated on a Si3N4/SiO2 membrane. The membrane was realized by wet etching from the back of an Si substrate using a 26 wt% KOH solution. The antenna was designed in accordance with the current band theory so that it covers the frequency range of 140–220 GHz. The experimental patterns for antennas located on the membrane and on the membrane backed by a copper plate reflector were in good agreement with theoretical patterns for the antenna located in air. Furthermore, a wide band characteristic of the antenna ranging from 140 to 220 GHz was obtained. The responsivity of the Bi microbolometer on the membrane estimated from the DC sensitivity under the irradiation of 220 GHz electromagnetic wave was 110 V/W. This value is about one order of magnitude higher than that of a Bi bolometer fabricated on a dielectric substrate. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- Open Access
- 1 January 2016
- Published by Nihon University School of Dentistry at Matsudo Research Institute of Oral Science in International Journal of Oral-Medical Sciences
- Vol. 14 (4) , 91-95
A Case of Classical Trigeminal Neuralgia Associated with Bilateral Agenesis of the Internal Carotid Arteries
- 1 January 2016
- Published by Nihon University School of Dentistry at Matsudo Research Institute of Oral Science in International Journal of Oral-Medical Sciences
- Vol. 14 (4) , 91-95
Open AccessA Case of Classical Trigeminal Neuralgia Associated with Bilateral Agenesis of the Internal Carotid Arteries
- 8 December 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02C110
Development of a compact ECR ion source for various ion production
There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.
- 8 December 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02C110
Development of a compact ECR ion source for various ion production
There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.
- 16 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02A730
First results of the 2.45 GHz Oshima electron cyclotron resonance ion source
A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.
- 16 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02A730
First results of the 2.45 GHz Oshima electron cyclotron resonance ion source
A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.
- Open Access
- 13 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02C107
Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)
With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.
- 13 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02C107
Open AccessRecent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)
With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.
- 3 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02A723
Producing multicharged fullerene ion beam extracted from the second stage of tandem-type ECRIS
We have been constructing the tandem-type electron cyclotron resonance ion source (ECRIS). Two ion sources of the tandem-type ECRIS are possible to generate plasma individually, and they also confined individual ion species by each different plasma parameter. Hence, it is considered to be suitable for new materials production. As the first step, we try to produce and extract multicharged C60 ions by supplying pure C60 vapor in the second stage plasma because our main target is producing the endohedral fullerenes. We developed a new evaporator to supply fullerene vapor, and we succeeded in observation about multicharged C60 ion beam in tandem-type ECRIS for the first time.
- 3 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02A723
Producing multicharged fullerene ion beam extracted from the second stage of tandem-type ECRIS
We have been constructing the tandem-type electron cyclotron resonance ion source (ECRIS). Two ion sources of the tandem-type ECRIS are possible to generate plasma individually, and they also confined individual ion species by each different plasma parameter. Hence, it is considered to be suitable for new materials production. As the first step, we try to produce and extract multicharged C60 ions by supplying pure C60 vapor in the second stage plasma because our main target is producing the endohedral fullerenes. We developed a new evaporator to supply fullerene vapor, and we succeeded in observation about multicharged C60 ion beam in tandem-type ECRIS for the first time.
- 30 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02A720
Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification
We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.
- 30 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02A720
Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification
We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.