Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maria Filomena Gomes Ferreira Crujo Camões has a total of 137 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility of multifunction calibration of H+-responsive glass electrodes in seawater (IUPAC Technical Report)

    by Daniela Stoica, Bárbara Velasco Anes, Paola Fisicaro, Maria Filomena Camões

    Seawater pH values are of the highest relevance in marine chemistry studies, not only through being acidity indicators but also due to the control provided by H+(aq) over the various simultaneous equilibria occurring in seawater. Although the concept of p H = − l g a H + = − lg ( m H + γ H + / m 0 ) $\mathrm{p}\mathrm{H}=-\mathrm{l}\mathrm{g}{\mathit{a}}_{{\mathrm{H}}^{+}}=-\mathrm{lg}\left({\mathit{m}}_{{\mathrm{H}}^{+}}{\mathit{\gamma }}_{{\mathrm{H}}^{+}}/{\mathit{m}}^{0}\right)$ , where m H + ${m}_{{\text{H}}^{+}}$ is the relative (molality basis) activity, γ H + ${\gamma }_{{\text{H}}^{+}}$ is the molal activity coefficient of the hydrogen ion H+ at molality m H + ${m}_{{\text{H}}^{+}}$ , and m 0 is the standard molality, was introduced in 1910 and reaffirmed on successive occasions by relevant bodies, different conceptual definitions and alternative measurement procedures have been adopted and are in use by some, namely among oceanographers, often leading to confusion. This leads to major difficulties with the use of data, e.g., on what concerns comparison of results in space and time. Primary pH values, the highest quality level in terms of the metrological chain, have been assigned to primary reference pH buffer solutions of low ionic strength, by a primary method based on measurements of the Harned cell potential in association with the Nernst equation, as well as on the adoption of extra-thermodynamic model assumptions for electrolyte solutions. Although equivalent types of recommendations dealing with standards and procedures based on metrological traceability are still lacking for higher ionic strength media, as it is in the case of seawater, reference Tris–Tris·HCl buffer solutions in artificial seawater have been suggested for use in the calibration of pH meter systems. In this work, Tris–Tris·HCl buffer saline solutions of three different molality ratios mTris:mTris.HCl, m/mol kg−1 H2O, have been assigned reference values for free p H = − lg a H + $\mathrm{p}\mathrm{H}=-\mathrm{lg}\,{a}_{{\text{H}}^{+}}$ and total pH T = − lg ( m H + * / m 0 ) ${\mathrm{pH}}^{\mathrm{T}}=-\text{lg}\left({m}_{{\text{H}}^{+}}^{\text{{\ast}}}/{m}^{0}\right)$ , where m 0 = 1 mol kg−1 and m H + * = lim m → m SW [ m ( H + ) + m ( HSO 4 − ) ] ${m}_{{\text{H}}^{+}}^{\text{{\ast}}}=\underset{m\to {m}_{\text{SW}}}{\mathrm{lim}}\left[m\left({\mathrm{H}}^{\mathrm{+}}\right)+m\left({\mathrm{HSO}}_{4}^{\mathbf{-}}\right)\right]$ . Multi-point calibration of pH meters in terms of either pH or pHT is thus possible and supports measurement of their respective values under routine conditions at a high metrological level.


  • Open Access

    Toward Unified pH of Saline Solutions

    by Silvie Lainela, Ivo Leito, Agnes Heering, Gaëlle Capitaine, Bárbara Anes, Filomena Camões, Daniela Stoica

    Fluctuations of pH in coastal systems are generally surveyed through potentiometric pH measurements. A new concept of a unified pH scale was introduced with the great advantage of enabling comparability of absolute values, pHabs, pertaining to any medium. Using water as an anchor solvent, yielding pHabsH2O, enables referencing the pHabs values to the conventional aqueous pH scale. The current work aims at contributing to implement pHabsH2O to saline solutions. To this purpose, differential potentiometric measurements, with a salt bridge of ionic liquid [N2225][NTf2], were carried out aiming at overcoming problems related to residual liquid junction potentials that affect the quality of such measurements. The ability to measure pHabsH2O with acceptable uncertainty was evaluated using Tris-Tris·HCl standard buffer solutions prepared in a background matrix close to the characteristics of estuarine systems (salinity of 20) as well as with NaCl solutions with ionic strength between 0.005 and 0.8 mol kg−1. The present study shows that for high ionic strength solutions, such as seawater, challenges remain when addressing the assessment and quantification of ocean acidification in relation to climate change. Improvements are envisaged from the eventual selection of a more adequate ionic liquid.


  • Open Access

    A unified pH scale for all solvents: part I – intention and reasoning (IUPAC Technical Report)

    by Valentin Radtke, Daniela Stoica, Ivo Leito, Filomena Camões, Ingo Krossing, Bárbara Anes, Matilda Roziková, Lisa Deleebeeck, Sune Veltzé, Teemu Näykki, et al.

    The definition of pH, its measurement and standard buffers, is well developed in aqueous solutions. Its definition in solvents other than water has been elaborated for a couple of solvents and their mixtures with water. However, the definition of a universal pH scale spanning all solvents and phases, not to mention standard procedures of measurement, is still a largely uncharted territory. UnipHied is a European collaboration and has the goal of putting the theoretical concept of an earlier introduced (2010) unified pH abs scale on a metrologically well-founded basis into practice. The pH abs scale enables the comparability of acidity between different phases. This article draws the connection of the concepts of unified acidity and secondary pH measurement.


  • Open Access

    Symmetric Potentiometric Cells for the Measurement of Unified pH Values

    by Agnes Heering, Daniela Stoica, Filomena Camões, Bárbara Anes, Dániel Nagy, Zsófia Nagyné Szilágyi, Raquel Quendera, Luís Ribeiro, Frank Bastkowski, Rasmus Born, et al.

    A unified pH scale of absolute values (pHabs scale) enables the comparison of acidities in different solvents. To date, very few different experimental setups have been used for the measurement of values on this scale. The article describes the design and performance of the different symmetric cells used for unified pH measurement by several institutions. Well-established and reliable standard aqueous buffer solutions are the first step of method validation necessary to achieve a robust metrological level for more complex media. The pH of aqueous standard buffers was measured by differential potentiometry, where the potential between two glass electrodes is measured directly. All the tested electrochemical cells prove to be suitable for unified pH measurements. This validation highlights that the method is, to a large extent, independent of the used equipment, including the cell geometry. The inherent symmetry of the cell design helps to reduce the experimental workload and improve the accuracy of obtained results.


  • Open Access

    Measurement of Total Reactive Phosphorus in Natural Water by Molecular Spectrophotometry (SMEWW 4500-P D)

    by Ricardo Bettencourt da Silva, Maria da Ascensão Rebelo da Silva Trancoso, Paula Alexandra Lourenço Teixeira, Cristina Maria Roque Ramiro de Oliveira, Alice Isabel de Jesus Mosca, Florbela Aura Do Sacramento Dias, Maria Filomena Gomes Ferreira Crujo Camões

  • Measurement of Ph. Definition, Standards, and Procedures

    by R. P. Buck, S. Rondinini, F. G. K. Baucke, C. M. A. Brett, M. F. Camões, M. J. T. Milton, T. Mussini, R. Naumann, K. W. Pratt, P. Spitzer, et al.

    The definition of a “primary method of measurement”1 has permitted a full consideration of the definition of primary standards for pH, determined by a primary method (cell without transference, Harned cell), of the definition of secondary standards by secondary methods, and of the question whether pH, as a conventional quantity, can be incorporated within the internationally accepted system of measurement, the International System of Units (SI, Système International d’Unités). This approach has enabled resolution of the previous compromise IUPAC 1985 Recommendations2. Furthermore, incorporation of the uncertainties for the primary method, and for all subsequent measurements, permits the uncertainties for all procedures to be linked to the primary standards by an unbroken chain of comparisons. Thus, a rational choice can be made by the analyst of the appropriate procedure to achieve the target uncertainty of sample pH. Accordingly, this document explains IUPAC recommended definitions, procedures, and terminology relating to pH measurements in dilute aqueous solutions in the temperature range 5–50 °C. Details are given of the primary and secondary methods for measuring pH and the rationale for the assignment of pH values with appropriate uncertainties to selected primary and secondary substances.


  • Open Access

    Traceability of pH to the Mole

    by Maria Filomena Camões, Bárbara Anes

    Free acidity of aqueous solutions was initially defined in 1909 by Søren Peter Lauritz Sørensen as pH = −lgcH+ (c/mol·dm−3 or m/mol·kg−1 of the free hydrogen ions in solution, H+) soon (1910) was changed to pH = paH+ = −lgaH+, integrating the new concepts of activity, ai and activity coefficient γi, for the ionic species i under concern, H+ in this case; it is ai = −lg(miγi). Since individual ions do not exist alone in solution, primary pH values cannot be assigned solely by experimental measurements, requiring extra thermodynamic model assumptions for the activity coefficient, γH+, which has put pH in a unique situation of not being fully traceable to the International System of Units (SI). Also the concept of activity is often not felt to be as perceptible as that of concentration which may present difficulties, namely with the interpretation of data. pH measurements on unknown samples rely on calibration of the measuring setup with adequate reference pH buffers. In this work, the assignment of pH values to buffers closely matching the samples, e.g., seawater, is revisited. An approach is presented to assess the quantity pmH+ = −lgmH+ profiting from the fact that, contrary to single ion activity coefficients, mean activity coefficients, can be assessed based on experimentally assessed quantities alone, γExp ±, thus ensuring traceability to the mole, the SI base unit for amount of substance. Compatibility between γExp ± and mean activity coefficient calculated by means of Pitzer model equations, γPtz ±, validates the model for its intended use.


  • A summer school where master students learn the skills needed to work in an accredited analytical laboratory

    by Philip D. P. Taylor, Danuta Barałkiewicz, Ricardo Bettencourt da Silva, Darinka Brodnjak Vončina, Ewa Bulska, Maria Filomena Camoes, Ryszard Dobrowolski, Marc Elskens, Ivo Leito, Nineta H. Majcen, et al.


  • Surface Changes at Platinized Platinum Based Hydrogen Gas Electrodes Following Use in Highly Saline Aqueous Solutions

    by M. F. Camões, B. Anes, C. S. Oliveira, M. E. Melo Jorge

    Platinized platinum based hydrogen gas electrodes, Pt(Pt)|H2(g)|H+(aq), and silver‐silver chloride electrodes, Ag|AgCl|Cl− (aq), make up the Harned cell, without transfer, working in the potentiometric mode at Cl− concentrations and ionic strengths, I, below 0.1 mol kg−1, for assigning primary pH values to reference pH buffer solutions. This work reports on experiments performed at higher I and Cl− solutions up to 0.7 mol kg−1, aiming at addressing seawater conditions with results of equally high quality. In the course of measurements, the occasional occurrence of highly unstable potentials denoted electrode malfunction; Pt metal surfaces observed by SEM/EDS and XRD exhibit strong Ag and Cl peaks corresponding to the presence of AgCl crystals deposited at both surfaces.