KSKoji Sakai

Koji Sakai

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Koji Sakai has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Self-folding graphene scaffolds with integrated electronics for cardiac tissue engineering

    by Alonso Ingar Romero, Koji Sakai, Toichiro Goto, George Al Boustani, Ryuya Kida, Defne Tüzün, Yuta Tanimura, Ann-Caroline Heiler, Joe Alexander, Andreas R. Bausch, et al.

    This multifunctional graphene platform enables 3D tissue assembly and electrophysiological recording of diverse cardiac models. Electrical stimulation allows modulation of network activity and supports longitudinal studies of cardiac function.

  • Open Access

    In Vitro Reconstruction of Axonal Heat Sensing with a Photothermal Nerve‐on‐a‐Chip

    by Koji Sakai, Yujiro Tanaka, Riku Takahashi, Toichiro Goto, Yosuke Mizuno, Taiki Otomo, Aya Tanaka

    Axons are the initial sites of thermal signal detection and transduction, but their localized response to heat remains poorly characterized. Here, we present a photothermal nerve‐on‐a‐chip platform that reconstructs in vitro the key elements of axonal thermosensation. By integrating graphene‐based photothermal heaters with microelectrode arrays inside axon‐guiding microchannels, the platform enables localized, millisecond‐scale thermal stimulation and simultaneous extracellular recording of action potentials. Using this platform, we uncovered rapid and reproducible heat‐evoked responses in rat dorsal root ganglion neurons, including thermoreceptor‐mediated rapid desensitization. With its ability to distinguish stimulus‐locked and inter‐pulse activity, we also observed distinct thermal‐response profiles in human iPSC‐derived sensory neurons, characterized by delayed heat responsiveness. Our platform enables high‐resolution analysis of axonal temperature coding and is a scalable tool for exploring peripheral thermosensation in development and disease.

  • An Accuracy-Improved Image Registration Method With High-Contrast Markers for Acoustic Impedance Microscopy

    by Tomomi Murai, Yujiro Tanaka, Koji Sakai, Takuro Tajima

    Acoustic impedance microscopy non-invasively measures three-dimensional cross-sectional images of cell stiffness. It can be used to perform real-time evaluations of cells by revealing the quantitative relationship between a cell’s stiffness and its physiology in various cell samples including two-dimensional cell sheets and three-dimensional structures. Image-based registration is a standard approach to investigate this relationship between acoustic microscopic images and optical microscopic images. However, the contrast in acoustic impedance images of cell sheets is too low for ordinary image-based registration to be applied with sufficient accuracy. Here, we propose a landmark-based image registration method that uses high-contrast registration markers visible in both acoustic impedance microscopy and optical (fluorescence and phase contrast) microscopy. By fabricating markers with a contrast 12-times higher than that of the surrounding cell sheet in acoustic microscopy, we have achieved image registration with a sub-5 μm position accuracy, which enables fundamental cell structures, i.e. nucleus and cytoskeleton, to be distinguished in acoustic impedance images. We also demonstrated its ability to precisely align multimodal images for cell- sheet analysis.

  • Open Access

    UV Laser‐Induced Carbon Microelectrode Arrays for Neuronal Recordings

    by Fulvia Del Duca, Koji Sakai, Beatrice De Chiara, Toichiro Goto, Defne Tüzün, Lukas Hiendlmeier, George Al Boustani, Hu Peng, Tetsuhiko F. Teshima, Simon N. Jacob, et al.

    Bioelectronic devices for in vitro and in vivo studies benefit from polymeric materials as substrates and insulations due to their flexible nature. Laser‐induced carbon formation has emerged as a rapid and versatile technique to fabricate conductive carbon‐based structures from insulating polymer films. Here, the development of electrodes fabricated via ultraviolet (UV) laser‐induced carbonization of chlorinated poly‐p‐xylylene (parylene‐C) insulation areas is reported. The parylene‐derived carbon is directly fabricated over the thin metallization layer, thus opening the desired electrode areas in a one‐step process. The optimal laser parameters for electrode performance are investigated, and the stability of the electrodes is tested under 10 000 voltage‐controlled stimulation pulses. In vitro tests of primary neuronal cultures confirm the biocompatibility of the proposed interfaces and reveal the good conformability of the neurons over the rough carbon structures. The performance of the sensor arrays is shown in electrophysiological recordings of neuronal cultures, together with a proof‐of‐principle stimulation, confirming the stability of the recordings over at least 4 weeks in culture. The proposed laser‐induced carbon electrodes from polymer coating are suitable as a rapid and precise fabrication protocol for carbon‐based sensors, applicable to bioelectronics and neuroelectronics devices.


  • Open Access

    Self-folding graphene cuff electrodes for peripheral nerve stimulation

    by Toichiro Goto, Koji Sakai, Yosuke Mizuno, Masumi Yamaguchi, Tetsuhiko F. Teshima

    Peripheral nerve stimulation using implantable electrodes has gained significant attention as a potential treatment for drug-resistant neurological disorders. Developing deformable thin-film electrode devices is essential to minimize damage when interfacing with fine nerve fibers. Here, we demonstrate a self-folding graphene-based thin-film electrode for peripheral nerve stimulation. The self-folding films were patterned with holes and slits to control the folding direction, enabling the thin film to wrap around nerve fibers while allowing current application through the slits. Approximately 80% of the films were confirmed to fold in the intended direction in accordance with the hole formations. Furthermore, the introduction of slits reduced the impedance between the graphene and the electrolyte. When applied to the sciatic nerve of a rat, the electrodes induced leg movement upon electrical pulse stimulation at 1 Hz, indicating successful excitation of motor neurons and subsequent muscle contraction. This electrode design will enhance the versatility of nerve stimulation by targeting finer nerve fibers, thereby contributing to advancements in neural stimulation therapies.


  • Open Access

    Small-artery-mimicking multi-layered 3D co-culture in a self-folding porous graphene-based film

    by Koji Sakai, Shigenori Miura, Tetsuhiko F. Teshima, Toichiro Goto, Shoji Takeuchi, Masumi Yamaguchi

    In vitro vessel-mimicking models have been spotlighted as a powerful tool for investigating cellular behaviours in vascular development and diseases. However, it is still challenging to create micro-scale tubular tissues while mimicking the structural features of small arteries. Here, we propose a 3D culture model of small vascular tissue using a self-folding graphene-based porous film. Vascular endothelial cells were encapsulated within the self-folding film to create a cellular construct with a controlled curvature radius ranging from 10 to 100 μm, which is comparable to the size of a human arteriole. Additionally, vascular endothelial cells and smooth muscle cells were separately co-cultured on the inner and outer surfaces of the folded film, respectively. The porous wall worked as a permeable barrier between them, affecting the cell–cell communications like the extracellular layer in the artery wall. Thus, the culture model recapitulates the structural features of a small artery and will help us better understand intercellular communications at the artery wall in physiological and pathological conditions.


  • Open Access

    Self‐Folding Graphene‐Based Interface for Brain‐Like Modular 3D Tissue

    by Koji Sakai, Tetsuhiko F. Teshima, Toichiro Goto, Hiroshi Nakashima, Masumi Yamaguchi

    Electrophysiology of 3D neuronal cultures is of rapidly growing importance for revealing cellular communications associated with neurodevelopment and neurological diseases in their brain‐like 3D environment. Despite that the brain also exhibits an inherent modular architecture that is essential for cortical processing, it remains challenging to interface a modular network consisting of multiple 3D neuronal tissues. Here, a self‐folding graphene‐based electrode array is proposed that enables to reconstruct modular 3D neuronal tissue and investigate firing dynamics among moduli. A graphene‐sandwiched parylene‐C film self‐folds into a cylindrical structure within which living cells can be encapsulated. Culture of encapsulated cells inside the folded graphene enables to spontaneously construct 3D cell aggregates and ensure firm contact between the graphene surface and encapsulated cells. As the inner graphene surface can be utilized as an electrode, the reliable cell–electrode contact allows for long‐term electrical recording from multiple 3D aggregates. Additionally, the modular network consisting of multiple 3D aggregates exhibits richer firing patterns than a conventional homogenous 2D network, which demonstrates that the approach enables measurements of firing dynamics in complex 3D neuronal networks. The deformable graphene electrode will be a powerful platform for investigating complex cellular communications in brain‐like 3D cultures.


  • Open Access

    Magnetometry of neurons using a superconducting qubit

    by Hiraku Toida, Koji Sakai, Tetsuhiko F. Teshima, Masahiro Hori, Kosuke Kakuyanagi, Imran Mahboob, Yukinori Ono, Shiro Saito

    Iron plays important physiological and pathological roles in the human body. However, microscopic analysis including redox status by a conventional electron spin resonance (ESR) spectrometer is difficult due to limited spatial resolution and sensitivity. Here we demonstrate magnetometry of cultured neurons on a polymeric film using a superconducting flux qubit that works as a sensitive magnetometer in a microscale area towards realizing ESR spectroscopy. By changing temperature (12.5–200 mK) and a magnetic field (2.5–12.5 mT), we observe a clear magnetization signal from the neurons that is well above the control magnetometry of the polymeric film itself. From ESR spectrum measured at 10 K, the magnetization signal is identified to originate from electron spins of iron ions in neurons. This technique to detect a bio-spin system can be extended to achieve ESR spectroscopy at the single-cell level, which will give the spectroscopic fingerprint of cells.


  • Open Access

    Three-dimensional self-folding assembly of multi-layer graphene at the interface with a polymeric film

    by Toichiro Goto, Tetsuhiko F. Teshima, Koji Sakai, Masumi Yamaguchi

    Three-dimensional (3D) architectures of graphene are of great interest for applications in flexible electronics, supercapacitors, and biointerfaces. Here, we demonstrate that multi-layer graphene (MLG), like single-layer graphene (SLG), can self-fold to form 3D architectures at the interface with a polymeric film. Bilayers composed of graphene and polymeric film tightly adhere to each other and possess a sloped internal strain, which leads to spontaneous rolling to predetermined 3D microscale architectures. The curvature radii of self-folding films can be controlled by changing the thicknesses of the polymeric film and the stacking order. In contrast to single-layer graphene, multi-layer graphene shows no strain in most of the outer graphene layers and linear ohmic current characteristics after self-folding. Throughout the self-folding process, the conductance of MLG decreases but remains higher than that of SLG. This versatile way of forming a 3D multi-layer graphene structure is potentially applicable for fabrication of practical carbon devices without the changes in their conductive properties.