RSRafik Shalaby

Rafik Shalaby

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rafik Shalaby has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Needlescopic cholecystectomy using 14-gauge assisting instruments: a technical modification for the pediatric age

    by Rafik Shalaby, Ashraf Hamed, Abdelmoneim Shams, Ahmad Khairi, Adham Elsaied, Amen Abokifa, Abdelwahab Elokby, Mohamed Ahmed Negm

  • Congenital webbed penis: Surgical outcomes of a simplified technique

    by Mohamed Negm, Salah Nagla, Rafik Shalaby, Nezar Abo Halawa


  • Needlescopic Disconnection and Peritoneal Closure for Pediatric Inguinal Hernia Repair: A Novel Technique

    by Rafik Shalaby, Mohamed Negm, Mohamed El-Sawaf, Adham Elsaied, Sherif Shehata, Ashraf Hamed, Sameh Shehata, Ahmed B. Radwan

    Background: There are many laparoscopic techniques for pediatric congenital inguinal hernia repair. Needlescopic surgery was introduced recently in pediatric patients aiming at getting excellent cosmetic outcomes. Purpose: The aim of this study was to describe a novel technique for needlescopic inguinal hernia repair in children. Patients and Methods: Needlescopic division of the hernial sac was carried out on 369 children in 6 pediatric tertiary centers during the period from August 2016 to May 2019. All hernias were repaired by a novel needlescopic procedure that replicates all the steps of the open herniotomy. Results: A total of 369 patients with 410 hernias were included in this study. They were 232 (62.9%) males and 137 (37.1%) females, with a mean age of 3.58±1.26 (range=2 to 8 y) and mean internal inguinal ring diameter was 13.65±3.85 mm (range=8 to 20 mm). The mean operative time was 23.36±4.67 minutes for bilateral and 14.28±2.98 minutes for unilateral cases. All cases were completed without conversion to conventional laparoscopy. All cases were followed up for a mean of 19.6±3.2 months. None of our patients developed recurrence or testicular atrophy and the scars were nearly invisible 3 months postoperatively. Conclusions: Needlescopic pediatric inguinal hernia repair using disconnection of the hernia sac at internal inguinal ring with purse-string suture closure of peritoneum is feasible and safe with no recurrence and with outstanding cosmetic results.


  • Needlescopic inversion and snaring for inguinal hernia repair in girls using 1.6-mm instruments

    by Rafik Shalaby, Mohamed Elsawaf, Yousef Mohamad, Mohamad Daboos, Al-Sayed Othman, Muhammad Abdelhafez, Refaat Ibrahim, Mohamed Ahmed Negm


  • Needlescopic Appendectomy in Children and Adolescents Using 14-Gauge Needles: A New Era

    by Rafik Shalaby, Mohamed I. Elsawaf, Soliman Mohamad, Ashraf Hamed, Mohamad Mahfouz

    Purpose: We are presenting a very minimally invasive technique for laparoscopic appendectomy (needlescopic appendectomy [NAP]) in children and adolescents using suture grasper device, epidural needle, and homemade isolated long diathermy probe without any conventional laparoscopic instruments. Patients and Methods: NAP was attempted in 48 patients with uncomplicated acute appendicitis at Al-Azhar, Tanta University Hospitals and other allied hospitals during the period from May 2017 to November 2018. The study included patients with acute appendicitis and patients scheduled for interval appendectomy. Exclusion criteria were patients with concealed appendix, patients with appendicular abscess or appendicular mass, patients with acute appendicitis complicated with generalized peritonitis, and patients unfit for laparoscopy. The appendix was brought outside through the umbilical port and the operation was completed extracorporeally. In cases of appendicitis with tethered cecum, the whole procedure was completed intracorporeally. Results: Forty-eight patients with acute uncomplicated appendicitis were treated by NAP. They were 36 males and 12 females with a mean age of 9 ± 3.7 years (range = 4–15 years). Two cases with concealed appendix and one case with appendicular mass were diagnosed during initial laparoscopy and excluded from the study. Thirty-two cases (71.11%) were completed intracorporeally and 13 cases (28.89%) were completed by extracorporeal NAP. The mean operative time was 33.29 ± 3.95 minutes (range = 27–40 minutes) for intracorporeal NAP and 20.9 ± 7.01 minutes (range = 14–40 minutes) for extracorporeal NAP. Degrees of cosmetic satisfaction of the patients and parents were excellent in 93.33% ( N = 42/45 patients), and very good in 6.67% ( N = 3/45 patients) of patients. Conclusion: NAP using needles only is a new technique that is very minimally invasive, very cheap, safe, reproducible, and easy to be done with outstanding cosmetic results.


  • Needlescopic Appendectomy in Children and Adolescents Using 14G Needles: A New Era

    by Rafik Shalaby, Mohamed I. Elsawaf, Soliman Mohamad, Ashraf Hamed, Mohmed Mahfouz

    Purpose: We are presenting a new very minimally invasive technique for laparoscopic appendectomy (needlescopic appendectomy [NAP]) in children and adolescents using suture grasper device, epidural needle, and homemade isolated long diathermy probe without any conventional laparoscopic instruments. Patients and Methods: NAP was attempted in 48 patients with uncomplicated acute appendicitis at Al-Azhar, Tanta University Hospitals and other allied hospitals during the period from May 2017 to November 2018. The study included patients with acute appendicitis and patients scheduled for interval appendectomy. Exclusion criteria were patients with concealed appendix, patients with appendicular abscess or appendicular mass, patients with acute appendicitis complicated with generalized peritonitis, and patients unfit for laparoscopy. The appendix was brought outside through the umbilical port and the operation was completed extracorporeally. In cases of appendicitis with tethered cecum, the whole procedure was completed intracorporeally. Results: Forty-eight patients with acute uncomplicated appendicitis were treated by NAP. They were 36 males and 12 females with a mean age 9 ± 3.7 years (range = 4–15 years). Two cases with concealed appendix and one case with appendicular mass were diagnosed during initial laparoscopy and excluded from the study. Thirty-two cases (71.11%) were completed intracorporeally and 13 cases (28.89%) were completed by extracorporeal NAP. Mean operative time was 33.29 ± 3.95 minutes (range = 27–40 minutes) for intracorporeal NAP and 20.9 ± 7.01 minutes (range = 14–40 minutes) for extracorporeal NAP. Degrees of cosmetic satisfaction of the patients and parents were excellent in 93.33% (N = 42/45 patients), and very good in 6.67% (N = 3/45 patients) of patients. Conclusion: NAP using needles only is a new technique that is very minimally invasive, very cheap, safe, reproducible, and easy to be done with outstanding cosmetic results.

  • Novel application of the sewing machine principle; a new simplified intracorporeal suturing technique for pediatric inguinal hernia

    by Rafik Shalaby, Mohamad Abdalrazek, Ashraf Hamed, Sayed Elhady, Refaat Ibrahim, Mohamad Shahin, Ahmad Helal, Adham Elsaied, Soliman Mohamad, Mohamad Mahfouz, et al.


  • Needlescopic assisted internal ring suturing; a novel application of low-cost home-made instruments for pediatric inguinal hernia repair

    by R. Shalaby, A. Elsaied, Sh. Shehata, A. Hamed, O. Alsamahy, Y. Ashour, I. Elsayaad, M. Shahin

    Congenital inguinal hernia (CIH) is a commonly performed surgical procedure in infants and children. Single port laparoscopic hernia repair using percutaneous internal inguinal ring (IIR) suturing procedure is a widely employed technique for indirect inguinal hernia repair in children. The majority of extracorporeal techniques use extracorporeal knotting and burying the knot subcutaneously. This may result in many drawbacks. The aim of this multicenter study is to introduce a new technique for pediatric inguinal hernia repair using only needles without any laparoscopic instruments.


  • One trocar needlescopic assisted inguinal hernia repair in children: a novel technique

    by Rafik Shalaby, Ibrahim Elsayaad, Omar Alsamahy, Refaat Ibrahem, Adham El-Saied, Maged Ismail, Abdelmoniem Shamseldin, Sameh Shehata, Mohamad Magid


  • Fifteen Years Experience with Laparoscopic Inguinal Hernia Repair in Infants and Children

    by Rafik Shalaby, Mohamed Abd Alrazek, Adham Elsaied, Ahmad Helal, Mohamad Mahfouz, Maged Ismail, Abdelmoniem Shams, Mohamad Magid

    Background: Laparoscopic inguinal hernia repair (LIHR) is gaining popularity with more studies validating its feasibility, safety, and efficacy. The aim of this work is to review our experience with LIHR in infants and children during the past 15 years, and present and evaluate our innovations of laparoscopic techniques. Patients and Methods: A retrospective study of 1284 patients with congenital inguinal hernia (CIH) subjected to different techniques of LIHR from October 2000 to October 2015. The main outcome measurements included the following: operative time, hospital stay, hernia recurrence, hydrocele formation, testicular atrophy, iatrogenic ascent of the testis, and cosmetic results. Inclusion Criteria: All patients with CIH who were managed by LIHR during the period of study. They were bilateral cases, recurrent hernias, unilateral hernia in obese child, unilateral hernia with associated infantile umbilical hernia, and unilateral hernia with questionable contralateral side. Results: A total of 1284 patients with CIH were corrected with different laparoscopic procedures. They were 918 males and 366 females. The age range was variable from 6 to 78 months (mean 28.32 ± 24.46 months). All cases were completed laparoscopically without major intraoperative complications. Contralateral hernial defects were found in 294 patients (22.90%), a direct inguinal hernia (IH) was discovered in 15 patients (1.17%), and a femoral hernia was discovered in 3 patients (0.23%). Recurrence occurred in 9 boys (0.98%) who were among the early cases; however, in later group, no recurrence had been detected. Hydrocele occurred in 19 cases (males) (2.07%), without detection of testicular atrophy or iatrogenic ascent of the testis. Conclusion: Our results lead us to believe that LIHR by expert hands is safe and effective. It enables the surgeon to discover and repair contralateral hernia and all forms of IHs. One should be able to tailor a suitable technique for each case according to the resources and expertise.