ARAnkit Raj

Ankit Raj

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ankit Raj has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accurate Determination of Absolute Raman Cross Sections of Carbon Dioxide Using H2 as a Reference

    by Ankit Raj, Henryk A. Witek, Hiro-O Hamaguchi

    The accurate determination of Raman cross sections is challenging for multiple reasons, the major one being the incomplete intensity calibration of experimental setups. In this work, the absolute Raman cross sections of CO2, a molecule important in environmental science and chemical engineering, are determined to high accuracy. To achieve this, we utilized a Raman instrument calibrated for precise intensity measurements using the rotational bands of H2. Supported by rigorous quantum mechanical data on H2 and a careful analysis of uncertainties introduced by various experimental factors, we reduced the uncertainty in the determined cross sections for the Fermi doublet of CO2 to 6% (3σ), with the primary sources of experimental uncertainty stemming from the detectors’ digitization error and thermal fluctuations. This report marks the most precise determination of Raman cross-section values to date, paving the way for improved quantitative Raman analysis of a wide range of samples and the retrieval of experimental transition polarizabilities for benchmarking ab initio methods.

  • Open Access

    Ligand-Unsupported Assembly of a Linear Penta-Tin Chain via Metal–Metal Donor–Acceptor Interactions

    by Yi-Chen Lin, Kuheli Das, Ankit Raj, Li-Ching Shen, You-Song Cheng, Ting-Shen Kuo, Han-Jung Li, Hirotsugu Hiramatsu, Sung-Fu Hung, Hsueh-Ju Liu

    Herein, we report a metal-metal interaction-driven strategy for constructing extended tin chains without relying on preorganized ligand frameworks. By combining a nucleophilic Sn(I) distannyne supported by a sterically undemanding dipyridylpyrrolate ligand with a neutral yet highly Lewis-acidic Sn(II) synthon, stepwise chain growth from di- to tri- and ultimately to a linear penta-tin complex was achieved. Multinuclear NMR, UV-vis, Raman, and X-ray absorption spectroscopies, together with elemental analysis, establish the structures and mixed-valence nature of the tri- and penta-tin complexes. Complementary density functional theory (DFT) calculations support these assignments by identifying the centrally located Sn(II) motif as the thermodynamically preferred arrangement and rationalizing the observed spectroscopic trends.


  • Open Access

    Posthandling Spectral Information Enhancement for Single Cell Raman Molecular Mapping Analysis

    by Ankit Raj, Nungnit Wattanavichean, Makoto Kawamukai, Tatsuyuki Yamamoto, Hiro-O Hamaguchi

    Biochemical analysis of living systems such as single cells benefits greatly from the label-free and low-invasive molecular mapping with Raman microspectroscopy. Sets of Raman spectra at different spatial points are analyzed to generate Raman molecular maps corresponding to specific chemical species. However, human error and subjective data analysis can be technical issues that limit interpretation and its validity. Here, we present an objective data analysis scheme for postprocessing large data sets of Raman spectra for molecular mapping of living cells. The process comprises three steps: (i) Denoising the spectral data set using low-rank approximation; (ii) obtaining an objective background from data points outside the target cell; (iii) subtracting the thus obtained background using Hypothetical Addition Multivariate Analysis with Numerical Differentiation (HAMAND) via an automatically determined coefficient. Through the present analysis, minor Raman peaks, as indiscernible as they are, can be identified and precisely mapped. We demonstrate a quantitative discussion of cellular components after extracting contributions only from a single target cell from a Raman mapping image where multiple cells or parts of other cells are present. This work opens an improved analysis workflow for accurate spectroscopic analysis of living cells with the advantage of identifying minor Raman peaks unambiguously.


  • Open Access

    Quantification of titanium dioxide (TiO2) anatase and rutile polymorphs in binary mixtures by Raman spectroscopy: an interlaboratory comparison

    by Alessio Sacco, Luisa Mandrile, Li-Lin Tay, Nobuyasu Itoh, Ankit Raj, Alberto Moure, Adolfo Del Campo, Jose F Fernandez, Keith R Paton, Sebastian Wood, et al.

    This article presents an interlaboratory comparison (ILC) on Raman spectroscopy as a technique for relative quantification of the two most common polymorphs of titanium dioxide (TiO2)—anatase and rutile—in binary mixtures. Some standard methods are currently employed internationally for the determination of TiO2 content in samples (ISO 591-1, ASTM D3720-90), but require extensive sample preparation, do not distinguish between the two polymorphs or are accurate only for small fractions of either polymorph. Raman spectroscopy is a well-suited characterization technique for measuring and differentiating TiO2 in a fast, non-invasive way, while requiring no particular reagent or sample preparation. Eleven international participants conducted the study under the framework of Versailles Project on Advanced Materials and Standards. The collected data was analyzed by means of partial least squares regression after spectral preprocessing. The resulting models all show discrepancies of lower than 2% from the nominal values in the quantitative analysis over the concentration range of 5%–95% mixture fractions, with many datasets showing substantial improvement margins on this figure. The results of this ILC provide validation of Raman spectroscopy as a reliable method for quantification of TiO2 phases.


  • Missing Piece in Colloidal Stability─Morphological Factor of Hydrophobic Nanoparticles

    by Chin-Yi Chen, Meng-Ju Hsieh, Ankit Raj, Wei-Cheng Peng, Hiro-O Hamaguchi, Wei-Tsung Chuang, Xiaosong Wang, Chien-Lung Wang

    Hydrophobic nanoparticles (NPs) in water were considered unstable because they lack the repulsive electrostatic interaction and steric effect to prevent aggregation. In this study, porous hydrophobic NPs of two star-shaped giant molecules, POSS-(R)8, were found to be stable in water and able to retain their kinetic stability in a wide range of temperatures, pH values, and ionic strengths. Unlike the solid hydrophobic NPs that aggregate even with the negative zeta potential (ζ) induced by surface-structured hydrogen-bonded (SHB) water, the porous morphology of POSS-(R)8 NPs reduces the entropically driven hydrophobic effect to prevent aggregation. With the porous morphology, the hydrophobic NPs are stable without the hydrophilic or charged surface functional groups and demonstrate good encapsulation capability. The morphological factor of colloids is thus one of the missing pieces in the theory of colloidal stability that extends our understanding of colloidal science.


  • Raman spectra and structure of hydrogen‐bonded water oligomers in tetrahydrofuran–H2O binary solutions

    by Ankit Raj, Yu‐Jou Chen, Chien‐Lung Wang, Hiro‐O Hamaguchi

    Raman spectra of hydrogen‐bonded water oligomers have been resolved from concentration‐dependent Raman spectra of tetrahydrofuran (THF)–water binary solutions with the use of multivariate curve resolution with alternating least‐squares (MCR‐ALS) analysis, assisted by hypothetical addition multivariate analysis with numerical differentiation (HAMAND) procedure. A total of 38 Raman spectra acquired in the broad spectral range of 700–3810 cm−1 were analyzed in a multistep procedure to explain the spectral variations in terms of four components: pure THF, Spectra A, Spectra B, and Spectra C. A four‐component MCR‐ALS analysis was performed with initial guesses by HAMAND analysis to refine the spectral components and determine their concentration dependence. Of the MCR‐ALS resolved three spectra, A was identified as THF(H2O), B as THF(H2O)2 with two hydrogens attached to THF, and C as THF(H2O)n having two or more linearly hydrogen‐bonded oligomers of water (n = 2–4). Observed spectral changes of the OH stretch vibrations of water and those of the C–C/C–O stretches of THF were well reproduced by quantum chemical calculations. Formation of hydrogen‐bonded water oligomers in THF–water complexes has thus been revealed. The present study provides a new insight into the basics of hydrogen bonding formation in aqueous systems. It also provides experimental methodology for extracting concentration‐dependent minor spectral components contained in complex condensed‐phase Raman spectra.


  • Testing the limitations of harmonic approximation in the determination of Raman intensities

    by Ankit Raj, Yen-Bang Chao, Henryk A. Witek

    Raman intensities in molecular spectra are usually computed within double harmonic approximation. This procedure relies on treating a vibrating molecule as a collection of harmonic oscillators and on the assumption that polarisability tensor invariants display linear variations around the molecular equilibrium geometry. This methodology, originally formulated by Placzek, constitutes the theoretical foundation for computing Raman intensities in standard quantum chemistry packages. However, the two assumptions underlying double harmonic approximation have not been sufficiently tested. In this work, we employed exact anharmonic ro-vibrational wave functions and distance-dependent polarisability invariants together with their harmonic approximants to investigate the discrepancies in Raman intensities of the fundamental transitions in 12 diatomic molecules, caused by double harmonic approximation. We found that: (i) the errors in total Raman intensities were between −8.2% and +9.5%, (ii) the largest discrepancy was observed for F2, where the polarisability invariants could not be adequately modelled by their linear approximants, and (iii) quantum chemical methods fail to predict reliable polarisability invariants at non-equilibrium molecular geometries; the associated errors in Raman intensities are huge and completely overshadow the shortcomings of double harmonic approximation. We communicate here an urgent need for developing accurate methods capable of computing reliable polarisabilities also at distorted geometries. GRAPHICAL ABSTRACT


  • Accurate intensity calibration of multichannel spectrometers using Raman intensity ratios

    by Ankit Raj, Chihiro Kato, Henryk A. Witek, Hiro‐O Hamaguchi

    We present a general multistep procedure for the determination of wavelength/wavenumber‐dependent sensitivity of Raman spectrometers equipped with multichannel detectors. In this approach, we start with photons‐per‐wavenumber conversion (C0) followed by a correction (C1) for the channel‐to‐channel variation in the sensitivity. The final correction (C2) is determined from a set of observed intensity ratios for standard Raman bands of selected molecules, compared with the analogous reference set of their accurate theoretical counterparts. The developed approach is employed here for calibrating our Raman spectrometer in the high‐wavenumber region using the vibration–rotation Raman bands of H2, HD, and D2. Theoretical intensity ratios for these bands were computed using accurate ro–vibrational matrix elements of polarizability invariants. The presented scheme allowed us to significantly improve the accuracy of the relative Raman intensities for measured samples. The accuracy was examined by determining the Boltzmann temperatures from the Raman intensities and comparing them with the corresponding thermocouple measurements. The uncertainty of such a Raman thermometer was found to be within 5%, confirming the validity and robustness of the proposed intensity calibration scheme. The presented intensity correction goes beyond the scope of common calibration schemes, traditionally limited to emission standards like tungsten lamps. While the first two steps of our calibration process (C0 and C1) are fairly typical, the additional correction (C2) derived from Raman spectral intensities seems to constitute an important novel step towards the standardization of Raman spectroscopy.


  • Evaluating stability of a Raman spectrometer for long‐time experiments

    by Ankit Raj, Henryk A. Witek, Hiro‐O Hamaguchi

    Raman spectroscopic measurements spanning several hours to days are increasingly common and important. The stability of a Raman spectrometer becomes crucial when comparing spectra recorded at different occasions in such time‐intensive experiments. In this work, series of Raman spectra of benzene and emission spectra of neon were acquired using a standard Raman spectrometer operating in a typical air‐conditioned laboratory, with synchronized measurements of ambient parameters (pressure, temperature, humidity, etc.) subject to continuous unsystematic environmental drifts. The time‐dependent fluctuations of positions and intensities of selected bands in the series of spectra recorded over tens of hours displayed variations of up to ±0.3 cm−1 in the band positions and up to 2% in the associated Raman intensities, with experiments over longer time periods prone to more pronounced fluctuations. After accounting for change in the laser power fluctuations, the intensity variations were reduced to about 1%. Both the variations in the band positions and intensities showed practically no correlation with either of the ambient parameters or the refractive index of air. Tiny drifts in the laser wavenumber (on the order of 0.01 cm−1), attributed to the change in the refractive index of the laser cavity associated with the variations in the ambient pressure, were too small to account for the observed fluctuations in the band positions.