Nangang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nangang Zhang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Kan Liu
School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan, China
8 shared publications - Xing-Zhong Zhao
Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, School of Physics and Technology, Wuhan University, Wuhan, 430072, China
4 shared publications Feng Liu
Wuhan Textile University
3 shared publicationsZhi-Xiao Guo
Wuhan University
3 shared publicationsBoran Cheng
Department of Oncology, Peking University Shenzhen Hospital, Shenzhen, Guangdong, 518036, People's Republic of China
2 shared publicationsFeng Guo
Wuhan University
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 127660-127671
Single-Path Synergistic Active Focusing System for High-Throughput Whole Slide Imaging
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 127660-127671
Open AccessSingle-Path Synergistic Active Focusing System for High-Throughput Whole Slide Imaging
- 8 October 2019
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 23 (11) , 118
Simple and convenient microfluidic flow rate measurement based on microbubble image velocimetry
- 8 October 2019
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 23 (11) , 118
Simple and convenient microfluidic flow rate measurement based on microbubble image velocimetry
- 2 September 2019
- Published by Springer Nature in Biomedical Microdevices
- Vol. 21 (4) , 87
High-performance multiplex microvalves fabrication and using for tumor cells staining on a microfluidic chip
As we all know, microvalve holds great importance for microfluidic manipulation in chip. Herein, a simple method of high-performance multiplex microvalves chip fabrication was reported. In this method, a sandwich structure is established by inserting a polydimethylsiloxane (PDMS) membrane into two glasses, which is cheap and simple without any complex silicon-based device or soft lithography. Taking advantages of both the elasticity of the PDMS and the rigidity of glass, the microvalve chip showed good controls performance and had the ability of multiplex integration. Moreover, aided by a computer design program, this microvalves chip can be performed automatically, showing great potential to develop new highly integrated microfluidic devices. In addition, the fabricated multiplex microvalve chip is further successfully used for staining tumor cells automatically, improving the efficiency of cell identification process and reducing human errors. These results indicate this method opens up new avenues for multiplex microvalves fabrication and its biological application.
- 2 September 2019
- Published by Springer Nature in Biomedical Microdevices
- Vol. 21 (4) , 87
High-performance multiplex microvalves fabrication and using for tumor cells staining on a microfluidic chip
As we all know, microvalve holds great importance for microfluidic manipulation in chip. Herein, a simple method of high-performance multiplex microvalves chip fabrication was reported. In this method, a sandwich structure is established by inserting a polydimethylsiloxane (PDMS) membrane into two glasses, which is cheap and simple without any complex silicon-based device or soft lithography. Taking advantages of both the elasticity of the PDMS and the rigidity of glass, the microvalve chip showed good controls performance and had the ability of multiplex integration. Moreover, aided by a computer design program, this microvalves chip can be performed automatically, showing great potential to develop new highly integrated microfluidic devices. In addition, the fabricated multiplex microvalve chip is further successfully used for staining tumor cells automatically, improving the efficiency of cell identification process and reducing human errors. These results indicate this method opens up new avenues for multiplex microvalves fabrication and its biological application.
- 10 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1536-1541
Highly Efficient Isolation of Circulating Tumor Cells Using a Simple Wedge-Shaped Microfluidic Device
Objective: We have developed a novel simple wedge-shaped microfluidic device for high efficiently isolation of circulating tumor cells (CTCs) from cancer patient blood samples. Methods: We used wet chemical etching and thermal bonding technologies to fabricate the wedge-shaped microdevice and performed optimization assays to obtain optimal capture parameters. Cancer cells spiked samples were used to evaluate the capture performance. Clinic assays were performed to isolate and identify CTCs from whole blood samples of patients with liver, breast, lung and gastric cancer. Results: Outlet height of 5.5 μm and flow rate of 200 μL/min were chosen as the optimal CTC-capture conditions. This method exhibited excellent isolation performance (more than 85% capture efficiency) for four cancer cell lines (HepG2, SKBR3, A549, and BGC823). In clinic assay, the platform identified CTCs 5 in 6 liver (83.3%), 8 in 10 breast (80%), 5 in 8 lung (62.5%), 5 in 9 gastric (55.6%) patients and only 1 in 25 healthy blood samples (4%). Conclusion: Our wedge-shaped microfluidic device had several advantages, including relatively simple fabrication, high capture efficiency, simple sample processing steps and easy observation. Significance: This method had successfully demonstrated the clinic feasibility of CTC isolation and shown a great potential of clinically usefulness in monitoring tumor prognosis and guiding individualized treatment in the future.
- 10 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (6) , 1536-1541
Highly Efficient Isolation of Circulating Tumor Cells Using a Simple Wedge-Shaped Microfluidic Device
Objective: We have developed a novel simple wedge-shaped microfluidic device for high efficiently isolation of circulating tumor cells (CTCs) from cancer patient blood samples. Methods: We used wet chemical etching and thermal bonding technologies to fabricate the wedge-shaped microdevice and performed optimization assays to obtain optimal capture parameters. Cancer cells spiked samples were used to evaluate the capture performance. Clinic assays were performed to isolate and identify CTCs from whole blood samples of patients with liver, breast, lung and gastric cancer. Results: Outlet height of 5.5 μm and flow rate of 200 μL/min were chosen as the optimal CTC-capture conditions. This method exhibited excellent isolation performance (more than 85% capture efficiency) for four cancer cell lines (HepG2, SKBR3, A549, and BGC823). In clinic assay, the platform identified CTCs 5 in 6 liver (83.3%), 8 in 10 breast (80%), 5 in 8 lung (62.5%), 5 in 9 gastric (55.6%) patients and only 1 in 25 healthy blood samples (4%). Conclusion: Our wedge-shaped microfluidic device had several advantages, including relatively simple fabrication, high capture efficiency, simple sample processing steps and easy observation. Significance: This method had successfully demonstrated the clinic feasibility of CTC isolation and shown a great potential of clinically usefulness in monitoring tumor prognosis and guiding individualized treatment in the future.
- 17 September 2018
- Published by Springer Nature in Biomedical Microdevices
- Vol. 20 (4) , 83
A simple pyramid-shaped microchamber towards highly efficient isolation of circulating tumor cells from breast cancer patients
Isolation and detection of circulating tumor cells (CTCs) has showed a great clinical impact for tumor diagnosis and treatment monitoring. Despite significant progresses of the existing technologies, feasible and cost-effective CTC isolation techniques are more desirable. In this study, a novel method was developed for highly efficient isolation of CTCs from breast cancer patients based on biophysical properties using a pyramid-shaped microchamber. Through optimization tests, the outlet height of 6 μm and the flow rate of 200 μL/min were chosen as the optimal conditions. The capture efficiencies of more than 85% were achieved for cancer cell lines (SKBR3, BGC823, PC3, and H1975) spiked in DMEM and healthy blood samples without clogging issue. In clinic assay, the platform identified CTCs in 13 of 20 breast cancer patients (65%) with an average of 4.25 ± 4.96 CTCs/2 mL, whereas only one cell was recognized as CTC in 1 of 15 healthy blood samples. The statistical analyses results demonstrated that both CTC positive rate and CTC counts were positive correlated with TNM stage (p < 0.001; p = 0.02, respectively). This microfluidic platform successfully demonstrated the clinical feasibility of CTC isolation and would hold great potential of clinical application in predicting and monitoring the prognosis of cancer patients.
- 17 September 2018
- Published by Springer Nature in Biomedical Microdevices
- Vol. 20 (4) , 83
A simple pyramid-shaped microchamber towards highly efficient isolation of circulating tumor cells from breast cancer patients
Isolation and detection of circulating tumor cells (CTCs) has showed a great clinical impact for tumor diagnosis and treatment monitoring. Despite significant progresses of the existing technologies, feasible and cost-effective CTC isolation techniques are more desirable. In this study, a novel method was developed for highly efficient isolation of CTCs from breast cancer patients based on biophysical properties using a pyramid-shaped microchamber. Through optimization tests, the outlet height of 6 μm and the flow rate of 200 μL/min were chosen as the optimal conditions. The capture efficiencies of more than 85% were achieved for cancer cell lines (SKBR3, BGC823, PC3, and H1975) spiked in DMEM and healthy blood samples without clogging issue. In clinic assay, the platform identified CTCs in 13 of 20 breast cancer patients (65%) with an average of 4.25 ± 4.96 CTCs/2 mL, whereas only one cell was recognized as CTC in 1 of 15 healthy blood samples. The statistical analyses results demonstrated that both CTC positive rate and CTC counts were positive correlated with TNM stage (p < 0.001; p = 0.02, respectively). This microfluidic platform successfully demonstrated the clinical feasibility of CTC isolation and would hold great potential of clinical application in predicting and monitoring the prognosis of cancer patients.
- 17 May 2018
- Published by EDP Sciences in Wuhan University Journal of Natural Sciences
- Vol. 23 (3) , 244-250
Generation of Linear and Parabolic Concentration Gradients by Using a Christmas Tree-Shaped Microfluidic Network
This paper describes a simple method of generating concentration gradients with linear and parabolic profiles by using a Christmas tree-shaped microfluidic network. The microfluidic gradient generator consists of two parts: a Christmas tree-shaped network for gradient generation and a broad microchannel for detection. A two-dimensional model was built to analyze the flow field and the mass transfer in the microfluidic network. The simulating results show that a series of linear and parabolic gradient profiles were generated via adjusting relative flow rate ratios of the two source solutions (RL2 ≥0.995 and RP2 ≥0.999), which could match well with the experimental results (RL2 ≥0.987 and RP2 ≥0.996). The proposed method is promising for the generation of linear and parabolic concentration gradient profiles, with the potential in chemical and biological applications such as combinatorial chemistry synthesis, stem cell differentiation or cytotoxicity assays.
- 17 May 2018
- Published by EDP Sciences in Wuhan University Journal of Natural Sciences
- Vol. 23 (3) , 244-250
Generation of Linear and Parabolic Concentration Gradients by Using a Christmas Tree-Shaped Microfluidic Network
This paper describes a simple method of generating concentration gradients with linear and parabolic profiles by using a Christmas tree-shaped microfluidic network. The microfluidic gradient generator consists of two parts: a Christmas tree-shaped network for gradient generation and a broad microchannel for detection. A two-dimensional model was built to analyze the flow field and the mass transfer in the microfluidic network. The simulating results show that a series of linear and parabolic gradient profiles were generated via adjusting relative flow rate ratios of the two source solutions (RL2 ≥0.995 and RP2 ≥0.999), which could match well with the experimental results (RL2 ≥0.987 and RP2 ≥0.996). The proposed method is promising for the generation of linear and parabolic concentration gradient profiles, with the potential in chemical and biological applications such as combinatorial chemistry synthesis, stem cell differentiation or cytotoxicity assays.
- 25 October 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (4) , 93
Highly efficient isolation and release of circulating tumor cells based on size-dependent filtration and degradable ZnO nanorods substrate in a wedge-shaped microfluidic chip
Circulating tumor cells (CTCs) have been regarded as the major cause of metastasis, holding significant insights for tumor diagnosis and treatment. Although many efforts have been made to develop methods for CTC isolation and release in microfluidic system, it remains significant challenges to realize highly efficient isolation and gentle release of CTCs for further cellular and bio-molecular analyses. In this study, we demonstrate a novel method for CTC isolation and release using a simple wedge-shaped microfluidic chip embedding degradable znic oxide nanorods (ZnNRs) substrate. By integrating size-dependent filtration with degradable nanostructured substrate, the capture efficiencies over 87.5% were achieved for SKBR3, PC3, HepG2 and A549 cancer cells spiked in healthy blood sample with the flow rate of 100 μL min−1. By dissolving ZnNRs substrate with an extremely low concentration of phosphoric acid (12.5 mM), up to 85.6% of the captured SKBR3 cells were released after reverse injection with flow rate of 100 μL min−1 for 15 min, which exhibited around 73.6% cell viability within 1 h after release to around 93.9% after re-cultured for 3 days. It is conceivable that our microfluidic device has great potentials in carrying on cell-based biomedical studies and guiding individualized treatment in the future.
- 25 October 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (4) , 93
Highly efficient isolation and release of circulating tumor cells based on size-dependent filtration and degradable ZnO nanorods substrate in a wedge-shaped microfluidic chip
Circulating tumor cells (CTCs) have been regarded as the major cause of metastasis, holding significant insights for tumor diagnosis and treatment. Although many efforts have been made to develop methods for CTC isolation and release in microfluidic system, it remains significant challenges to realize highly efficient isolation and gentle release of CTCs for further cellular and bio-molecular analyses. In this study, we demonstrate a novel method for CTC isolation and release using a simple wedge-shaped microfluidic chip embedding degradable znic oxide nanorods (ZnNRs) substrate. By integrating size-dependent filtration with degradable nanostructured substrate, the capture efficiencies over 87.5% were achieved for SKBR3, PC3, HepG2 and A549 cancer cells spiked in healthy blood sample with the flow rate of 100 μL min−1. By dissolving ZnNRs substrate with an extremely low concentration of phosphoric acid (12.5 mM), up to 85.6% of the captured SKBR3 cells were released after reverse injection with flow rate of 100 μL min−1 for 15 min, which exhibited around 73.6% cell viability within 1 h after release to around 93.9% after re-cultured for 3 days. It is conceivable that our microfluidic device has great potentials in carrying on cell-based biomedical studies and guiding individualized treatment in the future.
- 19 June 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (4) , 617-626
Biocompatible TiO2 nanoparticle-based cell immunoassay for circulating tumor cells capture and identification from cancer patients
- 19 June 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (4) , 617-626
Biocompatible TiO2 nanoparticle-based cell immunoassay for circulating tumor cells capture and identification from cancer patients
- 20 July 2010
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 10 (2) , 453-458
A novel method for generation of amphiphilic PDMS particles by selective modification
- 20 July 2010
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 10 (2) , 453-458
A novel method for generation of amphiphilic PDMS particles by selective modification
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 782-785
Manipulation of Droplets in Micro-Channel Through Magnetic Field
Research on encapsulation has much future potential in pharmacology and biochemistry. In this paper, we present an approach to manipulate the movement of sodium alginate beads in micro-channel. Electric field is an effective method to control the movement of droplets, but its current, if there is any, may cause extra heat and the fabrication of on chip electrode is also expensive. However, by mixing nano ferroferric oxide in sodium alginate we can achieve magnetic micro beads, and they will cause no heat and current when exposing to a magnetic field.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 782-785
Manipulation of Droplets in Micro-Channel Through Magnetic Field
Research on encapsulation has much future potential in pharmacology and biochemistry. In this paper, we present an approach to manipulate the movement of sodium alginate beads in micro-channel. Electric field is an effective method to control the movement of droplets, but its current, if there is any, may cause extra heat and the fabrication of on chip electrode is also expensive. However, by mixing nano ferroferric oxide in sodium alginate we can achieve magnetic micro beads, and they will cause no heat and current when exposing to a magnetic field.