Mohammad Babakmehr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Babakmehr has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Farnaz Harirchi
Electrical and Computer Engineering, Clemson University College of Engineering and Sciences, Clemson, SC, USA
4 shared publications - Ahmed Al-Durra
Department of Electrical Engineering, Advanced Power and Energy Center, Khalifa University, Abu Dhabi, UAE
3 shared publications Marcelo Godoy Simoes
Electrical Engineering and Computer Science, Colorado School of Mines, Golden, Colorado United States 80401
2 shared publications- Marcelo Godoy Simoes
School of Technology and Innovations, Electrical Engineering, University of Vaasa, Vaasa, Finland
2 shared publications - Payman Dehghanian
George Washington University
2 shared publications - S. M. Muyeen
Qatar University
2 shared publications
Latest Publications
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (2) , 1403-1412
Robust Model Predictive Control of DC-DC Floating Interleaved Boost Converter With Multiple Uncertainties
DC-DC Floating Interleaved Boost Converter (FIBC) is recently introduced for converting low-level voltage generated by a renewable energy source to high-level voltage required for AC inverters. Although a desired voltage is expected at the output, designing a proper voltage gain for FIBC is challenging due to different types of uncertainties. For instance, the voltage generated by the energy source and, therefore, the input voltage of FIBC may change by a variety of parameters including external load. Furthermore, parametric uncertainty and measurement noise are other sources which can affect the control procedure. As a result, voltage gain for a fixed switching duty cycle may be uncertain. It demands a robust approach to guarantee the control performance under uncertainties without the need for individually tuning controller for each single converter. In this work, a robust model predictive control is employed to regulate the output voltage at the desired level despite the existing uncertainties. Controller parameters are fixed for any FIBC within the uncertainty range and further tuning is not required for individual converters. In addition, unlike the conventional controllers, the suggested controller is able to handle input-output constraints. Performance of the suggested controller is investigated through simulations carried out in MATLAB and the superiority of the proposed approach is verified over non-robust model predictive framework.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (2) , 1403-1412
Robust Model Predictive Control of DC-DC Floating Interleaved Boost Converter With Multiple Uncertainties
DC-DC Floating Interleaved Boost Converter (FIBC) is recently introduced for converting low-level voltage generated by a renewable energy source to high-level voltage required for AC inverters. Although a desired voltage is expected at the output, designing a proper voltage gain for FIBC is challenging due to different types of uncertainties. For instance, the voltage generated by the energy source and, therefore, the input voltage of FIBC may change by a variety of parameters including external load. Furthermore, parametric uncertainty and measurement noise are other sources which can affect the control procedure. As a result, voltage gain for a fixed switching duty cycle may be uncertain. It demands a robust approach to guarantee the control performance under uncertainties without the need for individually tuning controller for each single converter. In this work, a robust model predictive control is employed to regulate the output voltage at the desired level despite the existing uncertainties. Controller parameters are fixed for any FIBC within the uncertainty range and further tuning is not required for individual converters. In addition, unlike the conventional controllers, the suggested controller is able to handle input-output constraints. Performance of the suggested controller is investigated through simulations carried out in MATLAB and the superiority of the proposed approach is verified over non-robust model predictive framework.
- 11 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5282-5293
Artificial Intelligence-Based Cyber–Physical Events Classification for Islanding Detection in Power Inverters
Along with the rapid integration of distributed generation units (DGU) into the power grids is the rise in unconventional and unpredictable patterns of the undesirable cyber-physical intrusions and faults; this drastically increases the risk of islanding possibilities and threatens the sustainability of the energy delivery infrastructure. Classification of cyber-physical events and developing solutions to mitigate their impacts before rising to an islanding situation is a critical monitoring task in DGUs. Passive islanding detection has been widely applied to studying the behavior of voltage signals at the point of common coupling, which is a sophisticated challenge due to cross-similarity among fault (event) patterns and their fast dynamics. In this paper, a novel quadratic Time-frequency decomposition, namely HSS-Transform, is applied over an alternative complex representation of 3-phase signal defined by the synchronous reference frame transformation. We further exploit the principles of Informative Sparse representation-based Classification (TISC) to develop a comprehensive artificial intelligence framework for fast and reliable classification of DGU islanding and non-islanding events with the focus on practical limitations and requirements of a smart power electronics inviter as the desirable observational site. Different from the state-of-the-art techniques, TISC does not need any training procedure, while due to its linear mathematical formulation acts inherently fast with low computational burden on the inverter processing unit. Moreover, the simultaneous 3-phase feature extraction strategy ensures preservation of the between-phase information.
- 11 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5282-5293
Artificial Intelligence-Based Cyber–Physical Events Classification for Islanding Detection in Power Inverters
Along with the rapid integration of distributed generation units (DGU) into the power grids is the rise in unconventional and unpredictable patterns of the undesirable cyber-physical intrusions and faults; this drastically increases the risk of islanding possibilities and threatens the sustainability of the energy delivery infrastructure. Classification of cyber-physical events and developing solutions to mitigate their impacts before rising to an islanding situation is a critical monitoring task in DGUs. Passive islanding detection has been widely applied to studying the behavior of voltage signals at the point of common coupling, which is a sophisticated challenge due to cross-similarity among fault (event) patterns and their fast dynamics. In this paper, a novel quadratic Time-frequency decomposition, namely HSS-Transform, is applied over an alternative complex representation of 3-phase signal defined by the synchronous reference frame transformation. We further exploit the principles of Informative Sparse representation-based Classification (TISC) to develop a comprehensive artificial intelligence framework for fast and reliable classification of DGU islanding and non-islanding events with the focus on practical limitations and requirements of a smart power electronics inviter as the desirable observational site. Different from the state-of-the-art techniques, TISC does not need any training procedure, while due to its linear mathematical formulation acts inherently fast with low computational burden on the inverter processing unit. Moreover, the simultaneous 3-phase feature extraction strategy ensures preservation of the between-phase information.
- 14 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 16 (2) , 909-921
Compressive Informative Sparse Representation-Based Power Quality Events Classification
Power quality (PQ) events are referred to any abnormal deviation from the standard sinusoidal behavior of power signals within a power system. PQ events are usually studied by tracking the behavior of voltage signals over observation points of the system. IEEE standards have defined standard categories for PQ events based on their time behavior. Each class of these events may have different level of importance from different contributors perspective (utilities, system operators or costumers). Due to increasing the usage of sensitive technological loads such as transportation, banking systems and databases on one hand in addition to the uncertainty injected to the system from aggregation of renewables on the other hand, the fast and reliable PQ events classification is an important monitoring task in the future smart grid. In this paper, combining the theory of sparse recovery with a new high dimensional convex hull approximation framework we have developed a fast, reliable and adaptive PQ events classification methodology named Compressive-Informative Sparse Representation-based PQ events classifier. Unlike usual classification approaches, the proposed classifier does not need any training procedure while due to its linear mathematical formulation acts inherently fast. Moreover, it can be easily adapted to recognize the challenging combined PQ events in addition to any permanent change in the behavior of PQ patterns.
- 14 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 16 (2) , 909-921
Compressive Informative Sparse Representation-Based Power Quality Events Classification
Power quality (PQ) events are referred to any abnormal deviation from the standard sinusoidal behavior of power signals within a power system. PQ events are usually studied by tracking the behavior of voltage signals over observation points of the system. IEEE standards have defined standard categories for PQ events based on their time behavior. Each class of these events may have different level of importance from different contributors perspective (utilities, system operators or costumers). Due to increasing the usage of sensitive technological loads such as transportation, banking systems and databases on one hand in addition to the uncertainty injected to the system from aggregation of renewables on the other hand, the fast and reliable PQ events classification is an important monitoring task in the future smart grid. In this paper, combining the theory of sparse recovery with a new high dimensional convex hull approximation framework we have developed a fast, reliable and adaptive PQ events classification methodology named Compressive-Informative Sparse Representation-based PQ events classifier. Unlike usual classification approaches, the proposed classifier does not need any training procedure while due to its linear mathematical formulation acts inherently fast. Moreover, it can be easily adapted to recognize the challenging combined PQ events in addition to any permanent change in the behavior of PQ patterns.
- 5 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (5) , 4462-4473
Compressive System Identification for Multiple Line Outage Detection in Smart Grids
Real-time power line outage detection (POD) and localization is an important monitoring task for the modern smart grid. Reliable monitoring of power lines status plays a critical role in the system-wide blackout prevention. In this paper, the main aim is to address the multiple POD problems by exploiting the compressive system identification-a time-efficient approach in a complex network analysis. A typical power network is considered as a single graph, and the mathematical formulation of the POD problem is initialized using the dc power-flow model and graph theory concepts. Next, a sparse representation-based formulation for this problem (POD-SRP) is reported and further improved and generalized in case of multiple large-scale outages. Practical and technical challenges associated with this sparse recovery problem are partially addressed by developing new SRP solvers. Furthermore, a new sparse-based mathematical formulation for POD is introduced and termed as “Binary-POD-SRP,” which specifically deals with two particular issues, namely, the high coherence and the signal dynamic outrange. Finally, the identification performance of the proposed framework is evaluated by a variety of case studies, which are modeled using IEEE standard test-beds. We specifically discuss how the inherent challenges within large-scale multiple-outages can be solved by applying these new techniques and formulations.
- 5 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (5) , 4462-4473
Compressive System Identification for Multiple Line Outage Detection in Smart Grids
Real-time power line outage detection (POD) and localization is an important monitoring task for the modern smart grid. Reliable monitoring of power lines status plays a critical role in the system-wide blackout prevention. In this paper, the main aim is to address the multiple POD problems by exploiting the compressive system identification-a time-efficient approach in a complex network analysis. A typical power network is considered as a single graph, and the mathematical formulation of the POD problem is initialized using the dc power-flow model and graph theory concepts. Next, a sparse representation-based formulation for this problem (POD-SRP) is reported and further improved and generalized in case of multiple large-scale outages. Practical and technical challenges associated with this sparse recovery problem are partially addressed by developing new SRP solvers. Furthermore, a new sparse-based mathematical formulation for POD is introduced and termed as “Binary-POD-SRP,” which specifically deals with two particular issues, namely, the high coherence and the signal dynamic outrange. Finally, the identification performance of the proposed framework is evaluated by a variety of case studies, which are modeled using IEEE standard test-beds. We specifically discuss how the inherent challenges within large-scale multiple-outages can be solved by applying these new techniques and formulations.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Multi-functional double mode inverter for power quality enhancement in smart-grid applications
This paper introduces a new multi-functional double mode inverter (MFDMI) scheme, which is able to operate under a variety of operational conditions for aggregation of PV-based renewable energy resources. Detecting islanded situation within a new and fast approach, regulating the voltage in the islanded mode, smooth transition between islanded and grid-tied (GT) modes, injecting both active and reactive powers to the grid in addition to compensating the harmonics from nonlinear loads are beyond the most notable functionalities of the proposed framework. Technically, we exploit a combinational control scheme formed by instantaneous power theory, vector-control and a proportional integral resonant (PIR) controller to address the required functionalities. To deal with the low output power issue, photovoltaic (PV) cells are aggregated through a high gain DC-DC floating interleaved boost converter (FIBC). Moreover, a battery back-up module with bidirectional DC-DC floating interleaved buck-boost converter (FIBBC) is used to improve the system reliability and dispatch ability. The effectiveness of the proposed framework has been first verified within a comprehensive PSIM simulation results and then has been examined under realistic situations using the real-time simulator OPAL-RT with DSP modules (hardware in the loop) for a broad range of conditions and within different practical scenarios.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Multi-functional double mode inverter for power quality enhancement in smart-grid applications
This paper introduces a new multi-functional double mode inverter (MFDMI) scheme, which is able to operate under a variety of operational conditions for aggregation of PV-based renewable energy resources. Detecting islanded situation within a new and fast approach, regulating the voltage in the islanded mode, smooth transition between islanded and grid-tied (GT) modes, injecting both active and reactive powers to the grid in addition to compensating the harmonics from nonlinear loads are beyond the most notable functionalities of the proposed framework. Technically, we exploit a combinational control scheme formed by instantaneous power theory, vector-control and a proportional integral resonant (PIR) controller to address the required functionalities. To deal with the low output power issue, photovoltaic (PV) cells are aggregated through a high gain DC-DC floating interleaved boost converter (FIBC). Moreover, a battery back-up module with bidirectional DC-DC floating interleaved buck-boost converter (FIBBC) is used to improve the system reliability and dispatch ability. The effectiveness of the proposed framework has been first verified within a comprehensive PSIM simulation results and then has been examined under realistic situations using the real-time simulator OPAL-RT with DSP modules (hardware in the loop) for a broad range of conditions and within different practical scenarios.
- Open Access
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (5) , 4375-4384
Smart-Grid Topology Identification Using Sparse Recovery
Smart grid (SG) technology reshapes the traditional power grid into a dynamical network with a layer of information that flows along the energy system. Recorded data from a variety of parameters in SGs can improve the analysis of different supervisory problems, but an important issue is their cost and power efficiency in data analysis procedures. This paper develops an efficient solution for power network topology identification and monitoring activities in SG. The basic idea combines optimization-based sparse-recovery techniques with a graph theory foundation. The power network (PN) is modeled as a large interconnected graph, which can be evaluated with the dc power-flow model. It has been shown that topology identification for such a system can mathematically be reformulated as a sparse-recovery problem (SRP), and the corresponding SRP can efficiently be solved using SRP solvers. In this study, we especially exploit the concentration of nonzero elements in the corresponding sparse vectors around the main diagonal in the nodal admittance or structure matrix of the PN to improve the results. The network models have been generated with the MATPOWER toolbox, and MATLAB-based simulation results have indicated the promising performance of the proposed method for real-time topology identification (TI) in SGs.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (5) , 4375-4384
Open AccessSmart-Grid Topology Identification Using Sparse Recovery
Smart grid (SG) technology reshapes the traditional power grid into a dynamical network with a layer of information that flows along the energy system. Recorded data from a variety of parameters in SGs can improve the analysis of different supervisory problems, but an important issue is their cost and power efficiency in data analysis procedures. This paper develops an efficient solution for power network topology identification and monitoring activities in SG. The basic idea combines optimization-based sparse-recovery techniques with a graph theory foundation. The power network (PN) is modeled as a large interconnected graph, which can be evaluated with the dc power-flow model. It has been shown that topology identification for such a system can mathematically be reformulated as a sparse-recovery problem (SRP), and the corresponding SRP can efficiently be solved using SRP solvers. In this study, we especially exploit the concentration of nonzero elements in the corresponding sparse vectors around the main diagonal in the nodal admittance or structure matrix of the PN to improve the results. The network models have been generated with the MATPOWER toolbox, and MATLAB-based simulation results have indicated the promising performance of the proposed method for real-time topology identification (TI) in SGs.